| 1 | Earth work in foundation excavation up to 1.5m, ramming bottom, dressing sides, back filling and disposal of surplus soil with in a lead of 50m. |
| 2 | Cement concrete in foundation and plinth with stone ballast size 40mm including curing and compaction etc in 1:4:8 mix |
| 3 | Brick work in foundation and plinth using bricks of Ist class in CM 1:6 |
| 4 | Reinforced cement concrete work including curing compaction, finishing with rendering in cement sand mortar 1:3 and making good and joints excluding cost of centring, shuttering and reinforcement in 1:1.5:3 (1cement: 1.5course sand: 3-graded stone aggregate 20mm nominal size) Columan etc. |
| 5 | Reinforced cement concrete work including curing compaction, finishing with rendering in cement sand mortar 1:3 and making good and joints excluding cost of centring, shuttering and reinforcement in 1:1.5:3 (1cement: 1.5course sand: 3-graded stone aggregate 20mm nominal size) Columan etc |
| 6 | Add extra for Brick work in super structure using bricks of Ist class in CM 1:6 |
| 7 | Reinforced cement concrete work including curing compaction, finishing with rendering in cement sand mortar 1:3 and making good and joints excluding cost of centring, shuttering and reinforcement in 1:1.5:3 (1cement: 1.5course sand: 3-graded stone aggregate 20mm nominal size) |
| 8 | Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) in foundation and super structure up to 4.5m height above plinth level hot rolled deformed (IS: 1139) cold twisted (IS: 1786) bars.Grade - 415 |
| 9 | Centring and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of from work |
| 10 | P & L Cement concrete on roof |
| 11 | S & F Mosaic tiles on roof |
| 12 | Ceiling plaster in CM 1:4 -12mm thick |
| 13 | 20mm thick plaster on new work including curing and racking of joints in CM 1:6 |
| 14 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete (PWD BSR-2022 - Less-10%) |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work ( Two or more coat including base coat of water proofing cement paint) -(PWD BSR -2022 Less-10%) |
| 16 | Wall painting with plastic emulsion paint of required shade including all scaffolding. New work ( Two or more coat including base coat of water proofing cement paint) -(PWD BSR-2022 Les-10%) |
| 17 | S & F Stone chowkhat for door |
| 18 | S & F Flush door shutters |
| 19 | Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and |
| 20 | S & F wire mesh on Section window |
| 21 | S & F Iron bars on Section window |
| 22 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T- iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outerdimension). ( PWD BSR -2022. Less-10%) |
| 23 | Enamel painting on door |
| 24 | Earth work in filling with ordinary soil |
| 25 | Carriage of earth-lead Five KM |
| 26 | Cement concrete in floor with stone ballast size 40mm including curing and compaction etc in 1:6:12 mix |
| 27 | S & F Polished Kota stone flooring |
| 28 | S & F Vitrified tile flooring |
| 29 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. (PWD BSR-2022 Less- 10%) |
| 30 | S & F Glaze tiles on walls |
| 31 | Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (PWD BSR - 2022. Less - 10%) Grade 304 |
| 32 | Earth work in foundation excavation up to 1.5m, ramming bottom, dressing sides, back filling and disposal of surplus soil with in a lead of 50m.Hard soil |
| 33 | 1.5 to 4.50m depth |
| 34 | S & F RCC ring - 0.90cm dai |
| 35 | Providing and fixing of reinforced Ferro-Cement drain covers designed for \"AA\" class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. (RUDPI BSR - 2023. Less-10%) Standard Size 1000x800mm (100mm thick) for span 451 to 700mm |
| 36 | Earth work in foundation excavation up to 1.5m, ramming bottom, dressing sides, back filling and disposal of surplus soil with in a lead of 50m. |
| 37 | Brick work in foundation and plinth using bricks of class designation-75 in CM 1:6 |
| 38 | 20mm thick plaster on new work including curing and racking of joints in CM 1:6 |
| 39 | Earth work in foundation excavation up to 1.5m, ramming bottom, dressing sides, back filling and disposal of surplus soil with in a lead of 50m. |
| 40 | P & L SWP pipe - 110mm dai |
| 41 | Wiring for fan/light point in PVC conduct pipe as per specification |
| 42 | Wiring for Power/light point in PVC conduct pipe as per specification |
| 43 | Wiring for circuit/submain as per specification- 2x1.5Sqmm |
| 44 | S & F Ceiling fan |
| 45 | S & F Exoust fan |
| 46 | Compression testing machine 2000kn digital operated channel type model with calibration certificate. Small |
| 47 | Compression testing machine 2000kn digital operated channel type model with calibration certificate. Big |
| 48 | Air condition - 1.50 Tonne |
| 49 | Air condition - 2.00 Tonne |
| 50 | S & F PVC water storage tank |
| 51 | S & F Bib cock |
| 52 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mmC.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : (PWD BSR-2022 Less-10%)Size 630 mm x 500 mm dia for counter top |
| 53 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) (PWD BSR -2022. Less-10%)25 mm nominal size |
| 54 | S & F Full way valve-20mm |
| 55 | P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. ( PWDBSR -2022. Less-10%) |
| 56 | Flat Back (large) or half stall size |
| 57 | P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the walland floor ( PWD BSR -2022. Less-10%) |
| 58 | P & F Automatic Flushing Cistern of first quality (IS : 774 mark) of approved make fitting, siphon with copper tube, C.I. brackets complete including cutting and making good the wall. WVC (as per IS : 2556) 10 litres. ( PWD BSR -2022. Less- |
| 59 | Rain water pipe - 110mm |
| 60 | Yojna board |
| 61 | Contingency charges Please Enable Macros to View BoQ information |