| Sl. No. | Item Description |
| 1 | BOQ Dated24 Dec 2025 |
| 2 | GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XIV are prepriced by MES under Ser No. 1 to 14. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 3 | Lumpsum price worked out by the contractor for “Miscellaneous buildings/Structures\" as listed in Schedule ‘A’ Part - I. |
| 4 | Lumpsum price worked out by the contractor for “Site Clearance\" as listed in Schedule ‘A’ Part - II. |
| 5 | Lumpsum price worked out by the contractor for \"Road/Path/Culvert\" as listed in Schedule ‘A’ Part - III. |
| 6 | Lumpsum price worked out by the contractor for \"Area Drainage\" as listed in Schedule ‘A’ Part - IV. |
| 7 | Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – V. |
| 8 | Lumpsum price worked out by the contractor for “Compound wall / Fencing & Gate” as listed in Schedule ‘A’ Part – VI. |
| 9 | Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – VII |
| 10 | Lumpsum price worked out by the contractor for “External Electric Supply/DG Set” as listed in Schedule ‘A’ Part –VIII |
| 11 | Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part – IX |
| 12 | Lumpsum price worked out by the contractor for “Aviation Obstruction Light” as listed in Schedule ‘A’ Part –X |
| 13 | Lumpsum price worked out by the contractor for “Lift” as listed in Schedule ‘A’ Part – XI |
| 14 | Lumpsum price worked out by the contractor for “AMI & E/M items” as listed in Schedule ‘A’ Part – XII |
| 15 | Lumpsum price worked out by the contractor for “Fire Fighting” as listed in Schedule ‘A’ Part –XIII |
| 16 | Lumpsum price worked out by the contractor for “Demolition of existing buildings” as listed in Schedule ‘A’ Part – XIV |
| 17 | Sch \"A\" Part - XV : BUILDINGS OR WORKSDESIGN & CONSTRUCTION OF SEVEN STOREY (S+6)MARRIED ACCOMMODATION BUILDING WITH PARKING AND RCC OHT OF 25000 LITRE CAPACITY FOR SQN LDR TO GP CPT & FLT LT INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. |
| 18 | DESIGN & CONSTRUCTION OF EIGHT STOREY (S+7)MARRIED ACCOMMODATION BUILDING WITH PARKING AND RCC OHT OF 25000 LITRE CAPACITY FOR SGT/CPL INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. |
| 19 | DESIGN & CONSTRUCTION OF THREE STOREY (S+2)MARRIED ACCOMMODATION BUILDING WITH PARKING FOR SGT/CPL INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. |
| 20 | DESIGN & CONSTRUCTION OF SUB STATION BUILDING INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. |
| 21 | DESIGN & CONSTRUCTION OF PUMP HOUSE BUILDING INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. |
| 22 | DESIGN & CONSTRUCTION OF UNDER GROUND SUMP OF CAPACITY 100000 LITRES INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. |
| 23 | DESIGN & CONSTRUCTION OF STATIC WATER TANK OF CAPACITY 50000 LITRES INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. |
| 24 | SCHEDULE \"A\" Part- XVI (FITTINGS AND FIXTURES & MISC ITEMS) |
| 25 | ROADSupply and fix 800mm dia of convex Mirror made of PC material provided with suitable stainless steel pipe post of 75mm dia as per site requirement. It is meant for road turning, intersections, curves, T-junctions, Hospital, parking lots etc. it is also deal for surveillance. it should have clear & define mirror image having 130 degree of viewing angle. it is unbreakable & stronger than the glass and fixed on ground by PCC 1:2:4 as directed by Eng-in-Charge. |
| 26 | COMPOUND WALL & GATESupply and fix PVC coated (PVC Coat as per ASTM F668 class 2a nominal 0.5mm and min 0.4mm) Chain link fencing of mesh 75x75mm including line wires of dia 2.50mm with tensile strength & mass of zinc coating min 350Mpa as per IS 280, to any type of standards, rails, straining bolts, etc including provision of binding wires, complete all as specified and as directed. |
| 27 | EXTERNAL WATER SUPPLYSupply and fix flange/screw type Foot Valve Cast iron 80 mm bore including rubber insertion packing materials, nuts, bolts and washer including taking down unserviceable foot valve including disconnect and reconnect the suction pipe line in any situation complete all as specified and asdirected. |
| 28 | Supply and install centrifugal electric driven pump set 5 HP pump setwith suction/delivery of size 80/65 or 50/40 mm, three phase 440 volts 50 Hz KDI-GMI series three phase squirrel gauge induction motor in common base frame and coupled with pump complete including following parameters (a) Model No KDI -550 ++ GMI MS SS (b) Capacity 5 HP, three phase 415 volts, 50 Hz (c) Head range 36 to 52 mtr(e) Discharge capacity 3 to 6 Ltrs per minute, foundation nut bolts washers etccomplete all as specified and asdirected. |
| 29 | Material and labourfor construction of brick masonary valve of size 105 x 105 x 110 cm (internal) with brick work of sub class B old bricks built in cement mortar 1:4 and 10mm thick rendering on internal and exposed external surfaces of brick work in CM 1:4 be 15mm below GL and mixed with water proofing compound @2% by wt of cement with and incl 40x40x6mm angle iron and 3.15mm thick MS sheet cover with locking arrangement and 1 No 50mm size lock incl painting steel surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed. |
| 30 | Supply, Installing, testing and commissioning, CPRI approved indoor type cubical type LT feeder pillar box suitable for 415V, 3 Phase, 4 wire, 50 Hz, AC supply system fabricated from CRCA steel quality \"A\"totally enclosed, dust, weather & vermin proof, front & back openable, double door system lockable / openable by keys from both sides having pattern fancy locks stainless steel in opening handle with louvers & air vent gasket for natural flow of air, the bottom of the outer shell contains a detachable plate having provision for entry of adequate size with glands, 2.0 mm thick for outer shell and 2/1.6 mm thick for inner shell having TPN aluminium busbars of rating 1.5 times that of incoming MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom C type base channel of MS section not less than 100 mm, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 nos earth stud, solid bus bar connections from main bus bar to switchgears with required size and control wiring with minimum 1.5 Sqmm FRLS insulated copper conductor wire, cable alleys, cable gland plates for Indicating lamp LED type, CT, selector switch, MCB SP/SPNmultifunction digital energy meter. |
| 31 | The energy meter havingto measure voltage, current, PF KWH, KVAH, KVARH, general construction confirming to IS : 8623 / 93 and mounted on suitable PCC foundation with followiing detailed specifications & controls including connecting of all incoming and outgoing cable with cable glande :- (Make - CPRI approved/certified manufacture)(a) The size of panel isnot less than 1.00 x1.50 x0.45 Mtr indoor type having accomdoate 01 (one) Nos Incoming MCCB four pole (63 to 100) amps 36 KA , MCB outgoings TPN/four pole 6-32amps \"C\" curve 4 Nos, MCB SPN 16 amps \"C\" curve 1 Nos, DOL starter 5 HP capacity 4 Nos all as directed.Note : (i) The cost of PCC foundation included in quated rate.(ii)Each MCCB\"s having seperate enclosures, marking with feeder name(iii) The minimum height of PCC is 30 CM andratio of PCC 1:3:6 (iv) Earth work excavation, returing filling, removel for panel erection and cabling connection included in quated rate. |
| 32 | M & L for earthing complete with GIearth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI earth lead 25x4 mm by means of bolts, nuts, check nuts/bracing and washers all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and funnel with wire mesh and GI watering pipe 20mm dia, Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, with flush type handle with 16mm dia round bars and 40 mm dia GI pipe upto 7.5m for protection and connected to earthing test point all as specified or indicated including testing on completion. Note:- (i)GI earth strip upto 7.5m shall be included in the quoted rate(ii) PCC chamber shall be provided 50cm away from the plinth of building.(iii) Soils only using for returning filling of earth pits if additional soils reqd provided by the contractor without any extra cost.(iv) Earth pit chambers installed after compacting the earth pits by using pouring of water etc. |
| 33 | EXTERNAL ELECTRIC SUPPLYReturning and filling of trenches in two parts (i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. |
| 34 | Supply and fixCable junction box IP66 halogen free and weather proof for out door installation made of thermoplastic material of size 195 mm x135 mm x 90 mm, suitable for upto 16 sqmm cable entry & cable out opening , fitted with 01 Nos MCB , SP 6 to 32 amps for street light complete internally pre-wired fitted with terminals, connectors etc and including necessary fixing arrangement such as nuts, bolts, washers, MS clamps made of 20x5 mm and painting etc including making connection complete including taking down old unserviceable boxes all as directed. |
| 35 | All as per Item No 31 abovehere - in - before of size 295 mm x 195 x 100 mm complete. |
| 36 | Supply and fix street light timer panel outdoor type IP 54 protection internal wiring with FRLS cable of suitable capacity, inbuilt short circuit protection Supply, CPRI approved outdoor type suitable for 415V, 3 Phase, 4 wire, 50 Hz, AC supply system fabricated from CRCA sheettotally enclosed, dust, weather & vermin proof, front openable, single door system lockable / openable by keys fancy locksair vent gasket for natural flow of air, the bottom of the shell contains a detachable plate having provision for entry of adequate size with glands, 3.0 mm thick for outer shell confirming to IS/IEC 61439/60529 suitable to mounting on walls/floor with necessary clamp with nut bolt washer etcincluding connecting up all incoming and outgoing cable withcable gland with following accessories for three phase max load 12 KW, contactor 65 Amps TP. MCB 63 Amps TPN 2 Nos, digital/analog 24 hrs time switch, on/off , phase indication lights all as directed |
| 37 | Supply and fixGI bracketof size40 mm dia 1.20 Mtr long GI pipe light grade bent to shape including necessary fixing arrangement such as nuts, bolts, washers, MS clamps made of 20x5 mm and making connection etc complete all as specified and as directed. |
| 38 | Supply, Installing, testing and commissioning, CPRI approved indoor type cubical type LT feeder pillar box suitable for 415V, 3 Phase, 4 wire, 50 Hz, AC supply system fabricated from CRCA steel quality \"A\"totally enclosed, dust, weather & vermin proof, front & back openable, double door system lockable / openable by keys from both sides having pattern fancy locks stainless steel in opening handle with louvers & air vent gasket for natural flow of air, the bottom of the outer shell contains a detachable plate having provision for entry of adequate size with glands, 2.0 mm thick for outer shell and 2/1.6 mm thick for inner shell having TPN aluminium busbars of rating 1.5 times that of incoming MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom C type base channel of MS section not less than 100 mm, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 nos earth stud, solid bus bar connections from main bus bar to switchgears with required size and control wiring with minimum 1.5 Sqmm FRLS insulated copper conductor wire, cable alleys, cable gland plates for Indicating lamp LED type, CT, selector switch, MCB SP/SPNmultifunction digital energy meter. The energy meter havingto measure voltage, current, PF KWH, KVAH, KVARH, general construction confirming to IS : 8623 / 93 and mounted on suitable PCC foundation with following detailed specifications & controls including connecting of all incoming and outgoing cable with cable gland :- (Make - CPRI approved/certified manufacture) |
| 39 | (a) The size of panel isnot less than 1.20 x1.80 x0.45 Mtr indoor type having accomdoate 01 (one) Nos Incoming MCCB four pole 200 amps 35/36 KA , MCCB outgoings 4 pole160 amps 36 KA1 Nos, 4 pole 63 100 amps 25 KA 2 Nos, Change over switch 4 pole 160 amps 1 No, MCB TPN/four pole 32 amps \"C\" curve 4 Nos, MCB SPN 16 amps \"C\" curve 3 Nos, all as directed(Cpl/Sgt accn) |
| 40 | All as per item No 35 above The size of panel isnot less than 1.50 x1.80 x0.45 Mtr indoor type having accommodate 01 (one) Nos Incoming MCCB four pole 300/320 amps 35/36 KA , MCCB outgoings 4 pole160 amps 36 KA1 Nos, 4 pole 63 100 amps 25 KA 2 Nos, Change over switch 4 pole 200 amps 1 No, MCB TPN/four pole 32 amps \"C\" curve 4 Nos, MCB SPN 16 amps \"C\" curve 3 Nos, all as directed(Sqn ldraccn) Note For Sl No 22 to 28: (i) The cost of PCC foundation included in quoted rate.(ii)Each MCCB\"s having separate enclosures, marking with feeder name(iii) The minimum height of PCC is 30 CM andratio of PCC 1:3:6 (iv) Earth work excavation, returning filling, removal for panel erection and cabling connection included in quoted rate (v) The bus bar arrangement made suitable to DG/Mains supply for water/fire fighting pumps, lift & common area lightings |
| 41 | All as per item No 35 above The size of metering panel isnot less than 1.20 x5.80 x0.45 Mtr indoor type having accommodate 01 (one) Nos Incoming MCCB four pole 160 amps 35/36 KA , MCB SPN 32 amps \"C\" curve 33 Nos and energy meter 33 Nos all as directed. Note: For Panels : (i) The cost of PCC foundation included in quoted rate.(ii)Each MCCB\"s having separate enclosures, marking with feeder name(iii) The minimum height of PCC is 30 CM andratio of PCC 1:3:6 (iv) Earth work excavation, returning filling, removal for panel erection and cabling connection included in quoted rate (v) The separate enclosure for each energy meter with MCB including provide the reading glass on meter housing ( Sgt/Cpl accn) (vi) Energy meters paid and measured separately |
| 42 | All as per item No 35 above The size of metering panel isnot less than 1.50 x 3.0 x0.45 Mtr indoor type having accommodate 01 (one) Nos Incoming MCCB four pole 160 amps 35/36 KA, MCB TPN/four pole 32 amps \"C\" curve 10 Nos for energy meter all as directed ( Sqn Ldr accn) |
| 43 | All as per item No 35 above the size of panel isnot less than 1.20 x1.50 x0.45 Mtr outdoor type 3.15 mm thick sheet thickness having accommodate 01 (one) Nos Incoming MCCB four pole 350 amps 35/36 KA , MCCB outgoings 4 pole 200 amps 36 KA2 Nos, 4 pole 63 100 amps 25 KA 2 Nos, MCB TPN/four pole 32 amps \"C\" curve 2 Nos, MCB SPN 16 amps \"C\" curve 2 Nos, all as directed(Cpl/Sgt accn upgradation) |
| 44 | All as per item No 35 above the size of panel isnot less than 1.20 x1.80 x0.90 Mtr outdoor type 3.15 mm thick sheet thickness having accommodate 01 (one) Nos Incoming ACB 4 pole 630 amps fixed type 50 KA , MCCB outgoings 4 pole 200 amps 36 KA2 Nos, 4 pole 63 100 amps 25 KA 2 Nos,4 pole 400 amps 35 KA 1 Nos,MCB TPN/four pole 32 amps \"C\" curve 2 Nos, MCB SPN 16 amps \"C\" curve 2 Nos, all as directed(Offrs accnupgradation) |
| 45 | All as per item No 35above the size of panel isnot less than 1.20 x1.20 x0.45 Mtr outdoor type 3.15 mm thick sheet thickness having accommodate 01 (one) Nos Incoming MCCB four pole 100 amps 35/36 KA , MCCB outgoings4 pole 63 100 amps 25 KA 2 Nos, MCB TPN/four pole 32 amps \"C\" curve 4 Nos, MCB SPN 16 amps \"C\" curve 2 Nos, all as directed(Offrs accn DG old panel) |
| 46 | Supply and installation of silent diesel engine driven generating set 415 volts 3 phase 4 wire, of capacity 40 KVA DG Set engine as per IS 10001/10002 and alternator as per IS 13364 completecontrol panel with necessary meters and floor mounted including acoustic enclosure sound proof canopy to ensure pollution free complying with all latest CPCB norms as per ISO 3046 for pollution and noise complete of capacity 40KVA with AMF panel complete with the following:- (Make of DG set :- Kirloskar(KOEL) Cummins /Greaves /Caterpillar.) Note - The quoted rated deemed to be included for foundation as per OEM recommendation load testing of DG set withnecessary fuel and artificial load banks with out any extra cost |
| 47 | (a) Diesel Engine :- Diesel engine 3R 1190ETA 4G1 of 56 HP capacity multi cylinder inline, 4 stroke cycle, heavy duty water cooled radiator with installed filled coolant DFC 50 cooling for system at a speed of 1500 RPM rating for continuous duty and comprising of the following:-(i) Well designed air handling system with (a) Dry type, replaceable paper element air cleaner with restriction indicator(b) Air to air after cooling (c) Optimized turbocharger for increased altitude capabilities (ii) Optimized fuel consumption with (a) Inline fuel pump with mechanical governor (b) Spin on fuel filter (iii) Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperatures (iv) Full flow spin on lube oil filter (v) First fill of lube oil and coolant (vi) Electrical starter motor with soft start engagement feature (vii) Battery charging alternator (viii) 1 X 12 V DC battery 120/150 AH (ix) Suitable coupling and guard (x) Fly wheel with starter ring (xi) Fuel and lubricant oil filter (xii) Water pump and lub oil pump (xiii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 120/150 AH, 12 volts as per manufacture requirement including self starter connection cable. (xv) Hospital grade Silencer suitably optimized to meet stringent noise emission standards laid down byCPCB(b) Engine/alternator instrument panel shall be comprise with the following:-(i) Engine Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.and Aluminum bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’, Instrument fuses duly wired and ferruled ,MCCB of suitable rating with overload and short circuit protections. (ii) The control panel consists of the following parts(a) Microprocessor based generator set monitoring and control system. This control includes an include operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics. (i)LED backlit LCD display with tactile feel soft-switches and generator set status LED lamps (ii) Remote start-stop, Auto,Manual,Test operation features (iii) Engine Metering: Oil pressure, Engine temperature, Starting battery voltage, Engine running hours no of starts, warming up period etc (iv) AC Alternator Metering: L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency . (v) Engine Protection: Low lube oil pressure, High/Low coolant temperature, Battery Over/Under Volts, Fail to Crank / Start, Sensor failure, cranking lockout, Low fuel level. (vi) AC Alternator Protection: Over/Under Voltage, Over/Under Frequency, (vii) Data Logging: Engine Hours, total (viii) Emergency stop push button on control panel and canopy (ix)12 Volt DC operation (x)Sleep mode (xv) Safety alarm against high water temperature and lub oil pressure |
| 48 | (c) Alternator :- Alternator self existed, self regulated, Brushless type, Screen protected, Revolving field, alternator conforming to IS1336432 KW/ 40 KVA at the speed of 1500 RPM at 415 volt, 50 Hz, 3 phase, 4 wire system, phase sequence UVWPF 0.8with advance electronic voltage regulator at the variation of 1% class H insulation and IP23 enclosure directly coupled with engine (d) Common Base frame :-Common fabricated base frame for engine and alternator made from structure channel of I section or angle iron etc duly installed on the suitable leak proof PCC foundation (1:2:4) type B-1 including adequate number of suitable anti vibration pads all as per the recommendation of the manufacture Note PCC measured and paid separately(e) Fuel tank: DG set should have built in fuel tank made out from 2mm thick MS sheet and fuel guage of adequate capacity running for 12 hrs.(f)AMF Panel :- Supply, installation, commissioning and testing of AMF control panel 12 Volts DC system complete with internal wiring and floor mountedtotally enclosed made of CRCA sheet metal of 2 mm thick suitable thickness of angle iron frame workfor DG set incorporating the following:- |
| 49 | (a)One No AC volt meter 0-500 Voltswith selector switch. (b)One No AC Amp meter of suitable size with selector switch and current transformer of CTS 250 Amps. (c) LedSignal lamp indicators for indications ie running, load on DG,Load on - 01 Set. (d) MCCB FP of 160/200 Amps 32 KA for overload and earth fault protection - 02 Nos. (e)Four pole contactor 200 Amps with NO & NC function relays - 02 Nos (f) Battery charging indicator lamp - 01 Nos. (g)Instrument fuses with suitable range fuses - 01 Set. (h)Under voltage relay 3 phase 4 wire 415 volts - 01 No. (j) Digital electronic timerfor AMF operation - 01 No. (k) By Pass arrangement with rotary type by pass switch AC 4 pole 100 Amps rating to isolate AMF panel. (l) Engine starting/stoprelay unit (AMF Relay unit) (m) boost cum floot battery charger 12 volts - 01 No. (n) Annuncialator for fault indication (LOP/HWT). (o) DC voltmeter and Amp meter (p) Auto/manual selector switch. (q) Control supply should be provided by 2 single pole MCB with adequate size of cable from engine to AMF panel(r) any other suitable accessories for efficient working of AMF panel as per manufacturer instructions. |
| 50 | Shifting of DG set 62.5 KVA from existing location into Offrs Md accn area including disconnect/reconnect the all electrical cables with necessary size of lugs/gland and shifting the DG set with crane, support sillings without any damage of existing DG set, reinstall at new location including necessary transportation/T&P items required at siteall as directed |
| 51 | AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure IP 65 ENCLOSURE 50 HZ 100 to 270 volts single phase complete all as specified and as directed. |
| 52 | LIFTM & L for earthing complete with GIearth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI earth lead 4mm by means of bolts, nuts, check nuts/bracing and washers all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and funnel with wire mesh and GI watering pipe 20 mm dia, Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40 mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, with flush type handle with 16mm dia round bars and 15 mm dia GI pipe upto 7.5m for protection and connected to earthing test point all as specified or indicated including testing on completion. Note:- (i)GI earth strip upto 7.5m shall be included in the quoted rate(ii) PCC chamber shall be provided 50cm away from the plinth of building.(iii) Soils only using for returning filling of earth pits if additional soils reqd provided by the contractor without any extra cost.(iv) Earth pit chambers installed after compacting the earth pits by using pouring of water etc. |
| 53 | AMI & MISC E/M ITEMSSupply, design, installation testing, commissioning, integrate and maintain the Advanced Metering Infrastructure (AMI) comprising of following :- (a)Supply, installation, testing, commissioning of Smart Meters AC single phase, two wire, 240 volts, 50 HZ, 10 to 60 Amps suitable to work in existing AMI system(not more than 33% of a particular make to ensure interchangeability at a later date as per BIS 16444 with communication technology including GPRD/RF/Hybrid(RF+GPRS)/ Any other advanced technology as per CEA/TRAI regulations, prepayment/post payment features. (b) Supply/ Planning/ Setup/Tuning or RF communication infrastructure including Network Management (NMS) & Head End System (HES) for the project area.Suitable to work with existing AMI software and associated equipments system. (c) Integration/interface suitable to existing AMI system with application system lie metering/ billing/ collection.e proposed solution to upload and process meter data from the existing systems. (d) Tuning of communication system including cellular network (If required) to meet the performance requirement. (e) Business Intelligence, Analytics and Reporting. (f)Any sundry items like connecting wires, nuts, bolts, washers, screws etc are to be required to fit the meter are deemed to be included in the quoted rate. |
| 54 | All as specified in item No 46 above but three phase four wire 415 volts, 50 Hz of capacity 10 to 60 Amps |
| 55 | TELEPHONE /TV CONDUITSupply and fix modulartelephone socket RJ 11 one module all as directed |
| 56 | Supply and fix modularTV coaxial socketone module all as directed |
| 57 | DEMOLITION/DISMANTLINGE/M PORTIONTaking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof etc complete all as specified and as directed. |
| 58 | Taking down exhaust fan, any size and typesealing cable end, dismantling blades from fan and keeping in safe custodyand deposit to AGE E/M store yard complete all as specified and as directed. |
| 59 | Disconnecting electric connection and taking down main switch/SPN DB/TPN DBof any size and keep in safe custody for taking credit complete all as directed |
| 60 | Disconnecting electric/water connection from geyser and taking down into this position any capacity and deposit to AGE E/M store yard complete all as directed |
| 61 | Taking down Electric Meter any type from its position with disconnect the electric cable any size and depositing to AGE E/MStore Yard all as directed |
| 62 | Taking down Service connection/LT UG cable of size 2 core 10 sq mm, 4 core 25 sqmm and50 sqmm cable from building and removing from site complete and keep in safe custody for taking as a credit all as directed |
| 63 | Taking down Gate valve 50/40/25/20 mm dia complete in any position all as directed |
| 64 | ELECTRIC CHIMNEYSupply and install test and commissioning of auto clean kitchen chimney with baffle filter, auto clean alarm, touch and gesture control, I clean technology for notification of cleaning, builtLED light on hood(Hood primus plus energy BK90 )of size 90 cm and 1500 Cum per hour range with necessary ducting upto the wall ofkitchen suitable to exhaust the smoke in kitchen premises suitable for modular kitchen all as directed.Make : - Faber, Elica, Kaff, Glen |
| 65 | OUTSOURCING OF SERVICES FOR OPERATION OF LIFTSMaintenance and Operation of Two Nos Passenger lift i.e 08 Passengers Capacity 544 Kg and 13 passengers Capacity 1000 Kg installed at S+6 storey married accommodation building during the first year of defects liability period by employing one number lift operator for each shift on all days including Sundays and holidays in three shifts of 8 hours each i.e 0600 Hrs to 1400 Hrs and 1400 Hrs to 2200 Hrs & 2200 Hrs to 0600 Hrs all as specified and as directed by Engineer-in-Charge. Note: (i) The operator should be known the lift operation, rescue procedure, safety precaution etc. |
| 66 | Maintenance and Operation of Two nos passenger lift i.e 08 Passengers Capacity 544 Kg and 13 passenger Capacity 1000 Kg installed at S+7 storey married accommodation building during the first year of defects liability period by employing one number lift operator for each shift on all days including Sundays and holidays in three shifts of 8 Hrs each i.e 0600 Hrs to 1400 Hrs and 1400 Hrs to 2200 Hrs & 2200 hrs to 0600 Hrs all as specified and as directed by Engineer-in-Charge. Note: (i) The operator should be known the lift operation, rescue procedure, safety precaution etc. |
| 67 | All as per serial item No 58 but for second year during Defects liability Period |
| 68 | All as per serial item No 59 but for second year during Defects liability Period |
| 69 | COMPREHENSIVE MAINTENANCE OF LIFTS AND OUTSOURCING OF SERVICES FOR OPERATION OF LIFTSAll as per serial item No 58 but for first year after Defects liability Period |
| 70 | All as per serial item No 59 but for first year after Defects liability Period |
| 71 | All as per serial item No 58 but for second year after Defects liability Period |
| 72 | All as per serial item No 59 but for second year after Defects liability Period |
| 73 | All as per serial item No 58 but for third year after Defects liability Period |
| 74 | All as per serial item No 59 but for third year after Defects liability Period |
| 75 | Note:- (a) The instructions for daily/weekly/monthly routine maintenance of plant and machinery will be given by Engineer in charge as per standard norms. (b) The rate quoted shall be inclusive of the cost of consumable items like cotton waste, cleaning cloth, grease, nuts/bolts/washers, log sheet, Stationary etc and tools/safety helmet, shoe, two set of uniform for Lift operator as per standard. (c) The operator shall maintain the installations neat and tidy all as directed. (d) The contractor should ensure all provision as laid down by State/Central Govt. labour commissions Employees provident fund, ESI and in contract labour Act 1970 such as payment of minimum fair wages, working conditions etc are complied. (e) The contractor shall make payment to the tradesmen employee directly (online) to the employees saving bank account linked with Aadhaar No. the minimum wages prescribed by state Govt or Central Govt whichever is more shall be paid & monthly payment shall be submitted duly signed by contractor to AGE (I) for verification (e) The employees are entitled for EPF as per the laid down percentage shall be provided by the contractor (f) Reserves staff required to be employed during leave/off the staff employed (h) EPF & ESI for the tradesmen employed shall be made by the contractor (j) The duties/performance of tradesmen shall be checked and ensure by the contractor time to time and contractor shall be responsible for efficient functioning services. (k) The contractor shall be responsible for safe custody of departmental equipments (l) The unit rate quoted is deemed included for all provisions as mentioned above. |
| 76 | Comprehensive maintenance of 544 Kg capacity 8 passenger lift 01 No of any serving for S+6 floors building during first year after Defects liability Period, examing, adjusting, lubricating and repairs as required complete all as directed by Engineer-in-Charge. Note 1: Quoted rate shall be deemed to be included for all spares except specifically catered separately in BOQ items herein contract of the lift shall be carried out directly by the manufacturer or through the approved working party of the manufacture (as per MOU) and maintenance to be carried out as per manufacture schedule.(a) Systematically examine and adjust the following components (b) Machine, Worm Gear, Thrust Bearing, drive Sheave, Drive Sheave Bearing, Brake contact, Lining and Components. (c) Motor, Motor Generator, Motor Windings, Rotating Elements, Commutator, Brushes, Brush Holders, Bearings, Coils, Resistance for operating and Motor Circuits , magnet Frames and other mechanical parts. (d) Controller, Selector , leveling Devices , Cams, relays, Solid state Components e.g. PCBs, Transducers, resistors, Condensers, Power Amplifiers, Transformers, Contacts, Leads, Dashpots, Timing Device, Steel Selector Tapes and Mechanical and Electrical Driving Equipment. (e)Governor Sheave, Shaft Assembly, Bearing, Contacts and Governor Jaws. (f) Car and Hall mechanical Buttons, Car and Hall Position Indicators, Hall Lanterns, car Direction Indicators and All other car and Landing signal Fixtures. |
| 77 | (g) Deflector or Secondary Sheave, Bearings, car and Counterweight Guide Rails and Buffers, Top and Bottom Limit Switches, Governor tension Sheave Assembly, Compensating Sheave assembly, Car, Counterweight and Counterweight Guide shoes including Roller or Gibs. (h) Interlocks on Hoist way Door Hangers, Guide, Automatic Power Operated Door Operator, car Door Hanger, Car Door Contact, safety Shoe, Load Weighting Equipment, car Frame, car Safety Mechanism and Platform. (j) Furnish Lubricants compounded to manufacturer’s stringent specifications. (k) Examine periodically all safety devices and governors and make all customary safety tests. (l) The AMC contract starts from after the DLP of contract (m) All breakdown complaints attend within two hour of receiving the notice/massage, failure to attend the same within time will resulting a penalty of Rs.1000/hour delay (n) The routine maintenance report submitted to Engr-in-Charge |
| 78 | All as per Item No 69 here-in-before but capacity of Lift 1000 kg 13 Passenger during first year after Defects liability Period |
| 79 | All as per Item No 69 here-in-before but capacity of lift 544 Kg 8 Passenger for S+7 floors building during first year after Defects liability Period |
| 80 | All as per Item No 69 here-in-before but capacity of Lift 1000 Kg 13 Passenger for S+7 floors building during first year after Defects liability Period |
| 81 | All as per Item No 69 here-in-before but capacity of List 544 kg 8 Passenger during second year after Defects liability Period |
| 82 | All as per Item No 69 here-in-before but capacity of Lift 1000 kg 13 Passenger during second year after Defects liability Period |
| 83 | All as per Item No 69 here-in-before but capacity of lift 544 Kg 8 Passenger for S+7 floors building during second year after Defects liability Period |
| 84 | All as per Item No 69 here-in-before but capacity of Lift 1000 Kg 13 Passenger for S+7 floors building during second year after Defects liability Period |
| 85 | All as per Item No 69 here-in-before but capacity of List 544 kg 8 Passenger during third year after Defects liability Period |
| 86 | All as per Item No 69 here-in-before but capacity of Lift 1000 kg 13 Passenger during third year after Defects liability Period |
| 87 | All as per Item No 69 here-in-before but capacity of lift 544 Kg 8 Passenger for S+7 floors building during third year after Defects liability Period |
| 88 | All as per Item No 69 here-in-before but capacity of Lift 1000 Kg 13 Passenger for S+7 floors building during third year after Defects liability Period |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |