| 1 | M&L mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 2 | S&F of Plates (plain or chequered) channels, Square cut or notched (ordinary and counter sunk) forming holes, without any attachment including riveted, bolted, or welded attachment and welding should be used mig welding not arc welding all other specified for roof trusses and steel column complete all as specified and directed. |
| 3 | Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work complete all as specified and directed. |
| 4 | S&F of Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged, and jagged or lewised, exc 15 cm but n exc 30cm long and dia of neck in between 12mm to 25mm complete all as specified and directed. |
| 5 | S&F of Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged, and jagged or lewised, exc 30cm long and dia of neck in between 12mm to 25mm complete all as specified and directed. |
| 6 | S&F mild steel screw nut and bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm but n exc 10cm long and dia of neck 11 to 20mm complete all as specified and directed. |
| 7 | S&F mild steel Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts complete all as specified and directed. |
| 8 | S&F for 1mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed by Engineer in charge complete all as specified and directed. |
| 9 | S&F pre-painted galvalume aluminium zinc coating Gl based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 10 | M&L for preparing the steel surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed. |
| 11 | M&L Plain cement concrete Type C-1 (1:2:4) using 20mm graded stone aggregate as in copings, benchings water troughs and like including weathering, slightly rounded of chamfered angles and throating, with necessary form work complete all as specified and directed. |
| 12 | Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc, not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/ disintegrated rocks complete all as specified and directed. |
| 13 | M & L for PCC 1:4:8 Type D2 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 14 | M&L RCC M-30 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc.; basement slabs, underreamed piles and mass concrete complete all as specified and directed. |
| 15 | M&L RCC M-30 (using 20mm graded stone aggregate) as in columns, etc, complete all as specified and directed. |
| 16 | M&L RCC M-30 (using 20mm graded stone aggregate) as in lintel beam, roof beam etc complete all as specified and directed. |
| 17 | M&L RCC M-30 (using 20mm graded stone aggregate) as in chajjas etc complete all as specified and directed. |
| 18 | Use & waste formwork to sides of concrete foundation footing, bases of column and plinth beam and similar work etc, complete all as specified and directed. |
| 19 | Use & waste formwork to sides of columns, square, sqm rectangular etc complete all as specified and directed. |
| 20 | Use & waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc. also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and directed. |
| 21 | Use & waste Formwork to chullah hoods, chajjas, troughs and similar items including edge complete all as specified and directed. |
| 22 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | M&L for mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 24 | M&L for mild steel TMT bars 8mm dia as in stirrups spacer and binder, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 25 | M&L for brick work with old size fly ash bricks bricks staright or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 26 | M&L 15mm thick rendering on brick /concrete work surfaces in CM 1:4 finished fair and even without using extra cement using WPC as per manufactuere instructions mplete all as specified and directed.Note : WPC shall be measured and paid separately. |
| 27 | M&L 10mm thick redering on brick work surfaces in CM 1:6 finished fair and even without using extra cement complete all as specified and directed |
| 28 | M&L for Preparation of newly plastered surfaces of walls & applying three coats coats of white wash complete all as specified and directed. |
| 29 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed. |
| 30 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in rock complete all as specified and directed. |
| 31 | Removing excavated rock exc. 500m and upto total distance 1.5Km and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed. |
| 32 | S&F Steel rolling shutters 1.25mm thickness, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull gear operated type with bevel gear box and crank handle including complete ball bearing complete all as specified and directed. |
| 33 | Providing & Fixing false ceiling with Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross \"T\" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main \"T\" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using Gl soffit cleats fixed to existing RCC lintel with dash fasteners, Gl adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm các along main T, bottom exposed width of 15mm of all T-sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm complete at all as specified and directed. |
| 34 | M&L for aluminium partition using aluminium sections fitted with 5mm thick tinted glass in upper portion from 3\" height as required as per site and 12 mm thick prelaminated particle board both side of standard quality of approved make, any type upto 3\" height as required as per site from bottom using glazing clips including jointing cleat for fixing glazing clips, rubber packing anodised aluminium beading etc aluminium tower bolt, floor stoper and locking arrangement by providing latch lock of standard quality of approved make complete all as specified and directed. |
| 35 | S&F aluminium door shutters with frame of aluminium section including necessary joining cleats, glazing clips, rubber neoprene packing, brass handle and brass tower bolts of size 150mm x 02 Nos in each door, hinges, anodised aluminium snap beading screws, hydraulically regulated double action floor door spring made up of 1.25mm thick aluminium alloy sheet foundation box for each shutter, etc and incl fitted with 5mm thick tinned glass in glazed shutter with brass mortice lock 100mm 2 levers, vertical type complete all as specified and directed. |
| 36 | M&L for aluminium powder coated sliding window, ventilator three track including aluminium powder coated decorated grill sliding shutter 5mm thick tinted float glasses, necessary aluminium beadings fittings and other panels to prevent air from out side complete all as specified and directed and as per Chief Engineer Drg No CEBZ/TD/15/2011. |
| 37 | M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed cablein and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed inwalls/roof/ ceiling with suitable size of sunk type pressed steel modular terminal box andmodular white cover plate with frame for suitable module as per site requirements for mounting of modular switches, sockets, fan regulator etc and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth of the following complete all as specified and directed. |
| 38 | One light point controlled by one, one way switch. |
| 39 | One Ceiling fan & wall fan controlled by one, one way switch. |
| 40 | One three pin 5 Amp socket on same board with other switches. |
| 41 | One three pin 5 Amp socket on independent board. |
| 42 | All as per item No 37.00 above but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 1.5 Sqmmstranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth complete all as specified and directed. |
| 43 | S&F of modular switch 1 way 6/10Amp , 1 module complete all as specified and directed. |
| 44 | S&F of modular switch 1 way 16Amp, 1 module complete all as specified and directed. |
| 45 | S&F of modular socket 6Amp, 2/3 pin combined2 module complete all as specified and directed. |
| 46 | S&F of mdoular socket 6Amp/16 Amp, 2/3 pin combined 2 module complete all as specified and directed. |
| 47 | S&F modular ceiling fan regulator suitable for BLDC Fan, 230 volt AC, 2 module complete all as specified and directed. |
| 48 | S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all as specified and directed. |
| 49 | Supply & fixing ceiling fan 1200 mm sweep (BLDC) , 230 Volts,AC , 50 Hz, copper winded motor, BE star rated white colour complete with motor, blade set of three nos , down rod, canopy, shackle assy,Remote including and conecting with three core PVCinsulated, PVC round sheathed flexible wire with mulitstranded copper conductor provide by the contractor from ceiling rose to connector of ceiling fan and writing of MES No with black enamel paint complete all as specified and directed. |
| 50 | Supply & fix wall mounted fan 600 mm sweep, metal body suitable for 230 Volts, Single phase 50 Hz AC supply including connecting with three core flexibale copper cable complete all as specified and directed. |
| 51 | M & L for submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 sqmm multi stranded copper conductor cable drawn through and incl 25 mm dia PVC non metallic rigid concealed conduits and the conduits accessories incl one run of green colour earth continuity conductor with 6 sqmm multi stranded copper conductor cable complete all as specified and directed. |
| 52 | Supply and fixing LED flood light 120/150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 53 | S&F of MCB distribution board TPN 4 way, 415 volts, double door, with 200 Amps rated bus bar, neutral bar with shrouds, earth bar,IP-43 , made outof sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCBs as incomer andoutgoing including blanking plate complete all as specified and directed. |
| 54 | S&F of MCB distribution board single pole & neutral with 200 Amps rated bus bar,double door IP-43 DB\"s , made outof sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB\"s including blanking platecomplete all as specified and directed. |
| 55 | S & F of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, \"C\" curve complete all as specified and directed. |
| 56 | S & F of MCB SP, 240 volt, 63 Amp capacity, 10 KA, \"C\" curve complete all as specified and directed. |
| 57 | S & F of MCB SPN, 240 volt,63 Amp capacity, 10 KA, \"C\" curve complete all as specified and directed. |
| 58 | S&F of MCB TPN, 415 volt, 100 Amp capacity,10 KA, \"C\" curvecomplete all as specified and directed. |
| 59 | M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 complete all as specified and directed. |
| 60 | Supply and fixing LED lights fitting 1 x 16/18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 61 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed. |
| 62 | Supply and fixingtubes light grade GI tubing 40 mm dia withall fitting laid in trenches, fixed on pole/on wall for cable protection complete all as specified and directed. |
| 63 | Cutting of existing road/hard standing for crossing of LT cable and pipe for laying of LT cable / pipe including necessary excavation and earth work including repairing the same as per existing road/hard standing by providing PCC as per existing surface complete all as specified and directed. |
| 64 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 65 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed. |
| 66 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 67 | Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly complete all as specified and directed. |
| 68 | M & L for laying of bricks locally available sub class \"B\" bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed. |
| 69 | Total in Figures |
| 70 | Quoted Amount in Words |