| 1 | SCHEDULE \"A\" Part - I (BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:- |
| 2 | SCHEDULE \"A\" PART- II (SITE CLEARANCE ANDDEVELOPMENT) Details of prepriced Schedule is given in tender documents |
| 3 | SCHEDULE \"A\" PART- III( INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 4 | SCHEDULE \"A\" PART-IV ( INTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents. |
| 5 | SCHEDULE \"A\" PART- V (ROADS/PATH/CULVERT)Details of prepriced Schedule is given in tender documents. |
| 6 | SCHEDULE \"A\" PART- VI (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents |
| 7 | SCHEDULE \"A\" PART- VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents |
| 8 | SCHEDULE \"A\" PART- VIII(GARBAGE BINS)Details of prepriced Schedule is given in tender documents. |
| 9 | SCHEDULE \"A\" PART- IX(FIRE POINT)Details of prepriced Schedule is given in tender documents. |
| 10 | SCHEDULE \"A\" PART- X(EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 11 | SCHEDULE \"A\" PART- XI(EXTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 12 | SCHEDULE \"A\" PART- XII(LIFT)Details of prepriced Schedule is given in tender documents. |
| 13 | SCHEDULE \"A\" PART- XIII(HOT WATER SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 14 | SCHEDULE \"A\" PART- XIV(EXHAUST FAN)Details of prepriced Schedule is given in tender documents. |
| 15 | SCHEDULE \"A\" PART- XV(DEMOLITION)Details of prepriced Schedule is given in tender documents. |
| 16 | SCHEDULE \"A\" PART -XVI (MISCELLANEOUS ITEMS)Note:- This scheduleis not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.\" F \" signifies this fact only. |
| 17 | INTERNAL ELECTRIFICATIONSupply and fixing Modular metal fluxh box with modular white cover plate with frame 8 module complete allas directed and specified. |
| 18 | Supply and fix TV Coaxial cable socket modular type, complete all as specified and as directed. |
| 19 | Supply and fix Co-axial cable RG-6 heavy duly, good quality for TV socket connections, complete all as specified and as directed. |
| 20 | S&F 9W LED Mirror light having luminous efficacy >100, input voltage range 140-270 V, input frequency 50-60 Hz, complete all as specified and directed. |
| 21 | S&F LED security light fitting not less than1x35 watt with integral reflector made of aluminium alloy LM6 with LED driver, lamp, surge protector and all accessories pre wired including connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with GI bracket 1.5M long bend to shape of dia. 40 mm GI medium grade pipe with MS clampcomplete allas directed and specified. |
| 22 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means ofbolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2009) complete all as specified and directed.(For External and Internal Electrification) |
| 23 | EXTERNAL WATER SUPPLYS&F 75mm outer dia. PP-R Gate valves (brass insert), complete all as specified and as directed. |
| 24 | S&F 110mm outer dia. PP-R Gate valves (brass insert), complete all as specified and as directed. |
| 25 | M&L for construction valve pit chamber of brick masonary valve pit of size 600 X 600X 600 cm with brick work 50 mm thick internal and external plaster in cm 1:4 inlcluding 25 X 25 X 5 mm MSangle iron frame all around the fixed point by means of 04 Nos hold fast 150 mm long made out of flat iron, 25 X 6 mm embedded in PCC block 1 : 2 : 4 type B1 including hinges welded with angle iron frame and MS cover 3 mm thick , MS handle of suitable locking arrangements and applaying two coat of synthetic enamal paint over a coat of red oxide primer including necessary excavation, removing/returning filling in soft/loose soil all as directed |
| 26 | EXTERNAL ELECTRIFICATIONS&F polymer based dropout fuse unit complete set suitable and including for 11 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning, complete all as specified and as directed. |
| 27 | M&L for earthingwith copper earth plate electrode 600 x 600 x 3.15mm thickburried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 20 x 3 mm as earthing leadmeans of nut, bolts and washers made out of galvanised ireon mild steel and 40 mm dia GI pipe \"light grade\" for protection of earth lead and connected to contoll board or main switch or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C1 pre-cast cover RCC cover lab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and tesing, complete all as specified and as directed. NOTE : The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed in AF Station. |
| 28 | M&L for boring of holes under road, pavement, hard standing mannually or by trenchless technology using ultra sounding technique and necessary machine or mannuallyetc as per site requirment including S&F 150mm HDPE pipe for cable protection, complete all as specified and as directed. |
| 29 | Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Feerder Pillar board outdoor type, CPRI approved of suitable size made out of MS sheet3.15 mm thick, Type tested conforming to IEC 61439, powder coated , rear and front operated doorwith locking arrangement, suitable aluminium busbar and fixed on angle iron base suitable for pedastal mounting of size 50x50x5 mm at least 2 feet above GL to accomodating the following:- INCOMING :- (a) MCCB 320 Amps (adjuctable with range 0.8-1.0), 4 pole, 36 KA - 01 (incoming)OUTGOING :-(b)) MCCB 63 Amps, 4 pole,36 KA - 05 No(04 Outgoing+ 01 Spare) (c) MCB 32 Amps,DP, 15KA - 02 Nos (01 out going + 01 Spare)(d) Digital Multi-functional Meters for measuring current, voltage and frequencyincluding CTs of suitable rating and class Note : The rate also inclusive of all material mentioned from sl no (a) to (d) and P.C.C foundation etc complete. |
| 30 | Supply and fixing PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable 2.5 sqmm, 3 core 3 run and 1.5 sqmm earthing cablein and including through GI tube of light grade of 15mm bore dia. for connection of street light on pole / wall from over head conductor / junction box / DB including termination clip etc., complete all as specified and as directed. |
| 31 | M & L for cable junction box with IP 66 protection (halogen free and weather proof) for outdoor installations of size 155 x 210 x 92 mm with terminals including SP MCB of 6 A, gland for cable, Flat Iron clamp of size 20x3 mm, nuts, bolts, washers, provision of connectors for connection of cables etc.,complete all as specified and as directed. |
| 32 | ARBORICULTURESupply and plantation of Dup grass including preparation of ground to required depth and fillingof sweet earth, cow dung and watering etc., complete all as spefified and directed. |
| 33 | Supply and plantation of palm tree (height of tree not less than 45cm above ground level) incl preparation of ground to reqd depth and filling of sweet earth, cow dung and watering etc., complete all as specified and directed. |
| 34 | Supply and plantation of hedges including preparation of ground to required depth and filling of sweet earth, cow dung and watering etc. complete all as specified and directed. |
| 35 | Supply, laying, connecting and testing 20mm bore, galvanized mild steel tubing medium grade with and including all fittings, laid in trenches complete all as specified and directed. |
| 36 | S&F 20mm dia. sprinkler with all accessories and fixed to 20mm bore GI pipe complete all as directed.(Note : GI pipe will be measured and paid separately ) |
| 37 | The above rates against Srl Item No. 32.00 TO 34.00 shall include the cost of maintenance schedule regular watering / Manure, weed outs other growths etc. for a period of 01 Year after completion of work all as directed and specified. |
| 38 | Note:- Schedule of credit (Sch \"A\" Part- XVII) amount of Rs 13,982.00 shall be deducted from the total quoted amount of BOQ. |