| Sl. No. | Item Description |
| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 2 | Dismentling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 3 | M&L for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | M&L for Pre-painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed. |
| 5 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. |
| 6 | M&L for Machine cut kota stone slab flooring 18-20mm thick over 20mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto mirror finish complete all as specified and directed. |
| 7 | M&L for Machine cut kota stone slab flooring 18-20mm thick as in skiritng, riser of steps etc laid over 10mm thick cement plaster in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto mirror finish complete, complete all as specified and directed. |
| 8 | Demolition of un-reinforced cement concrete in any position,includingremoval of broken material from site, complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in plinth protection, 50mm thick, surfaces finished even and fair without using extra cement including provision of construction joints complete all as directed by Engr-in-Charge and as specified. |
| 10 | Taking down chowkats or frames with shutters (without taking of shutter from the frame) of any description alongwith fittings n.exc 1.5sqm each, complete all as specified and directed. |
| 11 | M&L for machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed in CM 1:4 for laying floor finishes complete all as specified and directed. |
| 12 | S&F aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing (minimum thickness of powder coating 50 micron) etc complete all as specified and directed. |
| 13 | S&F figured glass, pin-headedtype3.00 mm thick and glazing with oil putty or aluminium/rubber beading insquares n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 14 | S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 15 | S&F Mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete (Fe-410W Gde-E 250 quality-A) complete all as specified and directed. |
| 16 | S&F Mild steel bolts (dia of neck exc. 12 & n.exc 20 mm and length exc 30cm long) purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut fixed complete all as specified and directed. |
| 17 | S&F roof trusses (framed), trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 18 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applytwo coat ofsynthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 19 | Demolition of brickwork or stone/boulder masonry, built in cementmortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles including removing of rubish, complete all as specified and as directed by Engineer-in-Charge. |
| 20 | M&L for pre-cast cement concrete block masonry 1:3:6 Type C1 using 20mm graded crushed stone aggregate with solid blocks, exc. 10 cm in width and set in CM 1:4 complete all as specified and directed. |
| 21 | Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work (RCC Shelf) reinforcement cut as required to facilitate demolition,includingremoval of broken material from site, complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&Lfor use & waste wooden form work (rough finished surfaces ) to sides & soffits ofchajjas, parapets & facia and similar work n. exc 200 mm thick complete all as specified and directed. |
| 23 | M&L for reinforced cement concrete nominal mix 1:2:4type B1 using 20mm graded stone aggregate as in chajja, facia & slabetc complete all as specified and directed. |
| 24 | M&L for mild steel TMT Mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed. |
| 25 | Removal of damaged structural concrete along with loose damaged and crecked concrete/ cover concrete at all specified locations up to beyond the corroged steel reinforcements to a depth of 10 mm minimum behind the reinforcement by chhpping/ hacking with chisel and hammer or by mechinical means like chisel hammer, pneumatic chippers incl high pressure water jetting to chipped concrete and reinforcement and removal and disposal of debris within owners premises incl. all plants and machineries complete all as specified and directed. |
| 26 | Cleaning as directed & specified all rust/scales/ corrosion from reinforcement bars using rust remover Reebaklens RR- Rust remover, cleaning and etching agent supplied in 1/2, 1 and 5 ltr containers, having specific gravity 1.16-1.22 @ 25 degree celcius, reebaklens RR cleaning agent is a combination of acid based materials, corrosion inhibitors and dispersing agents and is supplied as a clear green solution application of reebaklens RR with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours followed by cleaning the surface with wire brush and washing surface with fresh water as required to exposed reinforcement bars complete all as specified and directed. |
| 27 | M&L for providing and applying inhibition coats/system to exposed reinforcement bars after drying & also new bars after cleaning & removing scales and rust completely as specified. Nitozinc primer Two component epoxy zincrich primer supplied in 1 and 5 ltrs pack, two component system based on metallic zink and epoxy resin which on mixing gives a grey coloured liquid. An anti corrosive coat contents active \"Zinc-rich\" system which combates corrosion by electro chemical means. having specific gravity of 1.75, adhesive bond strength > 1.5N/mm2 solid content 60%, 40 microns DFT, Fully dry/Rrcoatable-45 minutes to 1 hour. Typical application includes surface preparations by cleaning steel surface to a bright condition paying particuler attention to the back of exposed steel bars, mixed two components slow speed heavy duty drill fitted with a paddle, applying unbroken coat with suitable brush and alloy to dry, after 30 mins apply second coat to ensure complete cover to exposed steel/ reber etc complete. Total dry film thickness is 40 micronscomplete all as specified and directed. |
| 28 | Cutting, febrication new reinforcement FE-500 and fixing with old existing reinforcement which was reduced to 20 % or more of its original dia as provided in original structure and additional steels as directed by EIC to be fixed with chemical anchor grout lokfix E55- styrene free vinyl-ester resin based cartridge syatem for anchoring reinforcement supplied in 300 ML cartidgewith a single mixture nozzle, application inclueds drilling hole close to old reinforcement bar with suitable drill as per dia of the bars, cleaning the hole with wire brush and compressed air, putting lokfix E55 with gun followed by placing rebar with slide rotational motion to avoid air void formation etc complete all as specified and directed. |
| 29 | Drilling holes in to existing concrete substrate for anchoring of new rebars with 10 mm dia shear connectors at 0.5 mtr c/c and fixing with chemical anchor lokfix E55-styrene free vinylester resin based cartridge system for anchoring reinforcement supplied in 300 ml cartidge with a single mixture nozzle, shall be tested in accordance European approval to EAD-33087-00-0601 for use in post-installed rebar, which suspersedes ETAG 001 TR 023 (rebar), LEED compliant VOC Level, Fibre resistance < 120Mins, Seismic C1 testing as part of EAD 330499-00-0601 for specific fastening sizes etc. Typical application inclueds drilling holes 14mm dia and 90mm deep as per manufactures recommandation, cleaning the hole with wire brush and compressed air, putting lokfix E55 with gun followed by placing shear connector with slide rotational motion to avoid air void formation complete all as specified and directed. |
| 30 | M&L for providing and applying Renderoc RG-Polymer modified micro-concrete supplied in 25 kg moisture resistant bag should possess following properties when mixed with clean water at w:p ratio 0.16, such as compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength -2Mpa @ 28 days, flextural strength (BS 4551-80) Mpa at 28 days, Young\"s modulus-25 KN/mm2, Expansion characteristics (ASTM C827-1987) unrestrained expansion 1 to 4% pressure approx. 0.004 N/mm2, Thermal conductivity-1.5 W/m degree cel. fire rating (EN 1504 cl 5.5)-class A1, fresh wet density (mixed density @27 degree cel. ) -2100-2200 Kg/m3. Typical application inclued mixing whole bag with clean water about 4 litres mixing in suitable container with heavy duty slow speed mixture machine to produce uniform free flowing mix, pouring the same in to the form work using suitable arrangement or if required using pupping device for uniform flow of micro concrete. The side shuttering can be removed after 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. item rate ia inclusive of materials and labour, tools and tackles, scaffolding and transportation etccomplete all as specified and directed. |
| 31 | M&L for providing and applying bond coat on the prepared surface to receive polymer modified mortor/ polymer modified micro concrete , with two components epoxy based bonding coat Nitobound EP- Epoxy rasin concrete bonding agents supplied in 1/2, 1 and 4 ltr Packs, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength (BS 6319 Pt 2)-50 Mpa at 7 Days, Tensile strength (BS 6319 Pt.7)-20Mpa @ 7 days, flextural strength (BS 6319 Pt.3) -35 Mpa at 7 days, Shear strength (BS-6319 Pt.4) 10 MPa at 7 Days having an over lay time of 6 hrs and 30 degree cel. high bond strength : bound strengthis more then the tensile strength of goood quality concrete barrier coat acts as a \"barrier coat tothe migration of chloride inos from host concrete. Laying of reinstatement polymer modified mortor or micro concrete shall be completed within over lay time of bounding coat. The bond coat act as a bonding coat between old ad new concrete. Typical application includes cleaning all loose dust, dirt, grease from host concrete surface by suitable means, mixing both components of bond by heavy duty slow speed mixer until a unifrom consistency, apply unbroken coat of Nitobond EP with stiff brush covering complete area of patch repair before plcing mortor or nicro concrete. Item rate inclusive of materials all labour, tools and tackles, scaffolding and transportation etccomplete all as specified and directed. |
| 32 | M&L for Surface preparation of nonstructural part by gentle chipping by manually to make the surface rough and thoroughly cleaned with air as per standard practice and directions of Engineer -in-charge (including removal of external plaster, wherever exists) COST inclusive of transportation, labour, conveying debris away from the out side of MD land, tools and tackles, lead and liftetcincluding necessery scaffolding ,form work etc, complete all as specified and as directed by Engr-in-Charge. |
| 33 | M&L for providing and laying Renderoc SP-40 shrinkage controlled polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortor supplied in 25 kg moisture resistant bag when mixed with clean water at w:p ratio 0.18, achieves compressive strength (BS 1881 Pt. 116) -> 20 MPa at 1 day & > 45 MPa at 28 days. Tensile strength (BS 63199 Pt7)>2.5 Mpa at 28 Days, Flexural strength (BS 6319 Pt.3)>7 Mpa at 28 Days, During Shrinkage to ASTM C157-93, 28 days<1000 microstrain. Typical application inclues mixing entire bag with clean water about 4.25 ltr to 4.5 ltr, mixed with suitable container with heavy duty slow speed mixer machine to achieve lump free mortor consistency, placing and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slab, piles etc, where tha thickness of application is less then 50 mm in patch as per specification after applying bounding coat item rate is inclusive of materials all labour tools and tackles, scaffloding and transportation etc. complete as per specification and as directed by Engi-in-Charge. |
| 34 | Taking down cement plaster or terrazzo from brick walls of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 35 | M&L for rendering 15 mm thick, on other than fair faces of brick or concrete surfacesin cement mortar 1:4 by using water proofing compound @ 3% by weight of cement and surfaces finishedeven and smooth without using extra cement, complete all as specified and as directed by Engineer-in-Charge. Note :- WPC will be paid separately. |
| 36 | M&L for rendering 15 mm thick, on fair faces of brick or concrete surfacesin cement mortar 1:6 and surfaces finishedeven and smooth without using extra cement, complete all as specified and as directed by Engineer-in-Charge. |
| 37 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 38 | M&L for preparing new plastered surfaces of wall and applying two coat of OBD over a coat of alkali resistant priming paintcomplete all as specified. |
| 39 | M&L for Washing, rubbing down and stopping of distempered and painted surfaces of walland applyingone coat of distemper oil-emulsion on walls all as specified. |
| 40 | M&Lpreparation old painted surfaces of wall including removal of grass and applying one coats of acrylic weather proof paint complete all as specified and directed. |
| 41 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size exc 1.50 but n. exc. 4.00 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified. |
| 42 | S & F mild steel plain sheets 1.60mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required somplete all as specified. |
| 43 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., or for shafts, wells, cesspits, manholes etc., not exceeding 10 Sqm on plan and n. exc. 1.5 metre in depth and getting out, hard/dense soil, complete all as specified and as directed by Engineer-in-Charge. |
| 44 | M&L Hardcore of broken bricks of gauge n. exc 63mm, deposited spread and leveled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified. |
| 45 | M&K for plain cement concrete 1:4:8, type D-2, using 40mm graded crushed stone aggregate, as in foundation filling and mass concrete, complete all as specified anddirected by Engineer-in-Charge. |
| 46 | Use & waste of wooden form work (rough finished) tosides offooting, Beams,etc complete all as specified and directed. |
| 47 | Use & waste of formwork to sides of pillars, posts, struts, piers,columns, and stanchions Square, rectangular or polygonal etccomplete all as specified and directed. |
| 48 | Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping)complete all as specified and directed. |
| 49 | M&L for reinforced cement concrete nomonal mix 1:2:4 type B-1using 20mm graded stone aggregate as in columns, footings and the like complete all as specified and directed. |
| 50 | M&L for reinforced cement concrete nomonal mix 1:2:4 type B-1using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 metre span and chajjas complete all as specified and directed. |
| 51 | M&L for reinforced cement concrete nomonal mix type B-1 (1:2:4) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelvescomplete all as specified and directed. |
| 52 | M&L for mild steel 8mm diaTMT bars as in stirrupscut to length bent to shape required including cranking, hooking at ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified.complete all as specified and directed. |
| 53 | M&L for 75mm thick plain cement concrete 1:4:8type D-2using 40mm graded aggregate as in sub floors, sub bases, floors etc complete all as specified and directed. |
| 54 | Returning, filling in, including spreading , leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed by Engineer-in-Charge. |
| 56 | M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces, finished even and smooth without using extra cement as in ceiling complete all as specified. |
| 57 | M&L Preparation of new wall surface and applying two coats of weather proof acrylic paint over a coat of weather proofprimer with camoulfage pattern complete all as directed. |
| 58 | M&L for Preparation of newly plastered surfaces of ceiling & applying three coats coats of white wash complete all as specified. |
| 59 | M&L for preparing new plastered surfaces of wall and applying two coat of OBD over a coat of alkali resistant priming paintcomplete all as specified. |
| 60 | Dismentling of Wallandceilingboards(fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 61 | M&L solid PVC wall lining consisting of 5mm thick wood grain printed PVC sheet used instead of plaincolour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing given SSR Part-II complete all as specified and directed. |
| 62 | M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing given in SSR Part-II. |
| 63 | Dismantling floor, hearth or wall tiling including cement morter beddind (but not backing removing seviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 64 | M&L for vitrified ceramic tiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match match dark shed over and including 15mm thick screed in cement mortar 1:6 and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed. |
| 65 | -ditto- all as per item No 64 here-in-beforebut as on vertical surfaces such as skirting/dado over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified. |
| 66 | Refixing wooden shutters of any description in same openingexc 1.00 Sqmbut n.exc 2.00 Sqm each complete all as specified and directed. |
| 67 | S&F 2ndclass hard woodplain, solid, straight chowkat and frame wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified. |
| 68 | Refixing aluminium window with shutters (without taking off shutters from the frame) of any description in Other opening exc 1.5 sqm but n exc 4 sqm each, complete all as specified and directed. |
| 69 | M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed. |
| 70 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations as specified and directed. |
| 71 | S&F Hydraulic door closer of aluminium die cast body,designation No-3 universal type suitable for door shutter of 851 mm to 1000 mm weight between 61 Kg to 80 kg etc, complete all as specified. |
| 72 | S&F Steel work as in tubular trusses etc including special shaped washer , angle cleat, holdfast, gussete plate etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240cut or notched forming holes, without any attachment including drilling, fitting, riveting and or welding or connecting with bolts and nuts (incl rivet or nut and bolts) providing and fitting angle cleats Gussete plates etc also for welding plumbing, truing up and fixing complete as directed by Engr-in-Charge |
| 73 | S&F 6.00 mm thick polycarbonate sheets of superior quality in semi circle shape on roofs of desired colour and fixed with aluminium metal flat / angle/ tee sections includingrubber beadings and silicon water proofing sealent jell for joining the sheets together and self tighteining screws ofgood quality complete all as specified and directed by engr-in- Charge. |
| 74 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 75 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and making good disturbed surfaces of walls, floors etc to match with existing surfaces of colour shade complete all as specified anddirected. |
| 76 | Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, unsheathed,multistranded, flexible,copperconductor cable 1.5 sqmm,1100 volts grade drawnthrough and including PVC casing and caping/conduitof size25 mmorabove as required at site with all accessories such as Tee,corner, overlaping connector etc.on surface walls, roofs and ceilings etc. including concealed MS box factory made of suitable size fabricated out of 1.6mm thick MS sheet/modular plate and frame suitable for fixing and including bakelite hylam sheet 3 mm thick fixed flush with wall surface by means of stainless steel cadmium plated screws and cup washers suitable for mounting switches, sockets, fan regulators etc.and including 1.5 Sqmm PVC insulated, multistranded, unsheathed(Green colour),FRLS type single core, copper conductor cable as earth continuity conductor andconnecting to common earth dolly complete all as specified and directedfor One light point /Bell point controlled by one switch. |
| 77 | -ditto- all as per item No 76 here-in-before butfor One fan point controlled by one switch . |
| 78 | -ditto- all as per item No 76 here-in-before but for One 3 pin 6 amps socket out let point controlled by one 6 amps switch on independent board . |
| 79 | -ditto- all as per item No 76 here-in-before but for One 3 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 80 | -ditto- all as per item No 76 here-in-before butwith 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switchon on same board. |
| 81 | Materialand labour for Point wiring with 1.5 sqmm copper conductor single core core , cable (multistrand) PVC insulated FRLS(unsheathed) concealed drawing in existingPVC conduit/casing caping 25 mm dia, having wall thickness not less than 2 mm for one light pont, controlled by one , one way switch , including 1.5 sqmm PVC insulated FRLS (unsheathed ) copper conductor continuous earth wire complete all as specified and as directed. |
| 82 | -ditto- all as per item No 77 here-in-before but for One fan point controlled by one switch . |
| 83 | -ditto- all as per item No 77 here-in-before but for One 3 pin 6 amps socket out let point controlled by one 6 amps switch on independent board . |
| 84 | -ditto- all as per item No 77 here-in-before but for One 3 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 85 | -ditto- all as per item No 77 here-in-before butwith 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switchon on Ind board. |
| 86 | Supply & fix modular switch 6 Amps, one way, one module complete all as specified and directed. |
| 87 | Supply & fix modular switch 16 Amps,one way, one module complete all as specified and directed. |
| 88 | Supply & fix modular socket 6 Amps, 2/3 Pin combined, two module complete all as specified and directed. |
| 89 | Supply & fix modular socket 6 A/16 Amps, 6 Pin combined, two module complete all as specified and directed. |
| 90 | Supply & fix modular fan regulator stepped type 100 watts, two module complete all as specified and directed. |
| 91 | Supply & fix ceiling rose, 3 terminal, PVC/polycarbonate body complete all as specified and directed. |
| 92 | S & F Holder, PVC/Polycarbonate type with back plate suitable for pendant fitting, all as specified and directed. |
| 93 | Supply & fix Modular Bell push , complete all as specified and directed. |
| 94 | Supply & fix Bell buzzer Ding Dong, complete all as specified and directed. |
| 95 | S & F bulb 5 watt all as specified and directed. |
| 96 | Supply & fix in repair LED lights 1x20 watt ,220 V, AC decorative box type with driver , holder including LED tube light connecteing up with three core flexible copper conductor cable of suitable size from ceiling rose including connector block etc.and necessaryfixing arrangementat any height and removing old unserviceable item complete all as specified and directed. |
| 97 | Supply and fixing LED light fitting mirror type withhigh out put diffuser 2 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 98 | Supply and fix in repairrecess/surface mounting light fittings and supply and fix newLED 15 watt surface mounting light fitting LED backlit round or square (as reqd at site) down lighter with high effcient LEDs & glare free opal diffuser IP20, internally prewired, 230V, complete with all accessories such as electronic driver, connector block etc.and necessaryfixing arrangementat any height and removing old unserviceable item with all connected accessories complete all as specified and directed. |
| 99 | Supply and fixceiling fan , 1200 mm sweep, single phase, 230 volts,minimum 5 star rated white in colourcomplete with all accessories such as down rod (required length at site),blades, shackle clip, canopy and making cable connections including removing of old unserviceable fans from existing site and deposited to MES store all asspecified and directed . |
| 100 | Supply and fix exhaust fan300 mm sweeep, single phase, 230 volts, metallic body complete with all accessoriesincluding fixing arrangement in existing hole by providing rugged bolts embedded in wall and making good the disturbed portion and necessarycable connections including removing of old unserviceable fans from existing site and deposited to MES store complete all as specified and directed. |
| 101 | Supply & fix in repair recess mounting high lumen LED flat panel 2\"X2\" 36Watt, slim fit,white powder coated CRCA housing with highpower LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessaryfixing arrangementat any height and removing old unserviceable item complete all as specified and directed. |
| 102 | Material and labour for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi strandedduly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed.Note : -02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit. |
| 103 | Supply and fix in repairs MCB distribution board SPN 8 way 240 volts, double door withIP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed. |
| 104 | Supply and fixin repairMCB SP 6 to 32 Amps,10 KA, \"C\" series, 240 volts complete all as specified and directed. |
| 105 | Supply & fixin repair MCB SPN 32 Amps 10 KA, \"C\" series, 240 volts complete all as specified and directed. |
| 106 | S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts complete all as specified and directed. |
| 107 | Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, copper earth strip 20 x 3 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing complete all as specified. |
| 108 | Supply and fixing LED light fitting mirror type withhigh out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 109 | Supply & fixin repair MCB SPN 40 Amps 10 KA, \"C\" series, 240 volts complete all as specified and directed. |
| 110 | Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing complete all as specified. |
| 111 | Supply,lay and testing in replacement LT cableXLPE insulated,galvanised steel strip armoured,1100 volts gradewith multistranded aluminium conductor of cross-sectional area 16 sqmm; 2 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail