| Sl. No. | Item Description |
| 1 | Complete removal of old roof treatment incudingcement mortar ( except mudfushka , brick tile ) andremoval of grass, small trees by picking sweeping , cleaning and washing down with water to remove dust etcincuding removing debries out side MOD land,complete all as specified and directed. |
| 2 | M&L for 15 mm thick cement plasterover the concrete / brick roof surfaces in cement mortar 1:4mixed with liquid water proofing compound@ 200ml per bag WPC (liquid type), surface finished even and smooth without using extra cement all as specified and directed. Note:- Water proofing additive shall be measured and paid separately. |
| 3 | M&L forWater proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge.. (a)Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.40 Kg/Sqm of area complete all as specified. (b)Laying 3mm thick APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 Kg/Sqm with laps & overlaps as specified & joints sealed and appliedover a coat ofbitumin of Gde 85/25 1.2 kg per sqm complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE. |
| 4 | M&L for Cleaningall the dust, existing roof treatment and loose material by brush/blower/Grinder including removing of vegetation/plantation from the surface. M&L for preparation of roof top surfaces, providing and applying single component elastic cold applied polyurethane modified acrylic roofing system, co elastic technology (CET) based on modified polyurethane and fully fibre reinforced, having Sun Reflectivity index (SR) of 109 on top of concrete roof surfaces. All cracks up to 3 mm at corner joints, channel and parapets should be treated with crack seal. Applying three coatsincluding one coatof primer ofShaliUrethane BTD/ Sikalastic 560/ smart care damp proof-ultra having coverage @ min 0.75kg/m2and dilution up to 10% andlaying reinforced fiber net and applying two coats (without dilution) of shaliUrethane BTD/Sikalastic 560/smart care damp proof ultra@totalconsumption 2 kg/m2intwo coats for maintainingminimum dry filmthickness 1.5mm and elongation at breakof free film of approx 350%. The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge/Consultant (Note :6 Hrs interval between two coat will be maintained). All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system.Make: STP/Sika/Asian paint or equivalent as approved by GE. Note:- Application of water proofing treatment will be done by Authorised Applicator only.(i) The water proofing treatment shall be carried out by the manufacturer or their authorized applicators duly approved by GE in writing.(ii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However, contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor\" risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor\"s quoted rates for this item shall deemed to be inclusive of this aspect. |
| 5 | M&L non skid ceramic tiles colored tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,in floor etc set and jointed in neat cement slurry and pointed in colour cement laid over and including 15mm thick cement mortar screed bed in CM (1:6) including dismantling complete all as specified and directed. |
| 6 | M&L Viterified ceramic tiles 10 mm thick square/rectangularlight shade texture polished,area of each tilesNot exceeding 0.36 sqm,in floor etcb set and jointed with neat cement slurry and pointed with white cement mixed with pigment to match the colour of the tileincluding 15mm thick cement mortar screed bed in CM (1:6) including dismantling complete all as specified and directed. |
| 7 | M&LViterified ceramic tiles 10 mm thick square/rectangularlight shade texture polished area in vertical surfaces as skirting/dado of each tilesNot exceeding 0.36 sqm,in floor etcb set and jointed with neat cement slurry and pointed with white cement mixed with pigment to match the colour of the tileincluding 15mm thick cement mortar screed bed in CM (1:4) including dismantling complete all as specified and directed. complete all as specified and directed. |
| 8 | M&L glazed ceramic coloured tiles size 450mm x 300mm x 7mm/350mm x 250mm thick in walls etc set and jointed in neat cement slurry and pointed in colour cement laid over 10mm thick backing coat in CM (1:3) including dismantling complete all as specified and directed. |
| 9 | M&L for mirror polishing on marble/granite/kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed. |
| 10 | Dismantling of Stone slabs laided in any mortar complete all as specified and directed. |
| 11 | M&L for Granite (of any type) tiles 18mm to 19mmthick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including screed bed 20mm thick in cemen tmortar 1:6complete all as specified and directed. |
| 12 | M&L for providing Mirror polished kota sotne slab flooring 20mm to 22mm thck over and including 20 mm thick screed in Cement morter1:3 and jointed with grey cement slurry mixed with pigment including cutting and mirror polishing incl demolition all as spd and directed. |
| 13 | M&L for mirror polishedkota stone slab 20mm to 22mmthick as in dado skirting over cement10mm thick backing coat in cement mortar 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed. |
| 14 | M&L 16mm to 18mm Udaipur Green marble stone slab machine cut, bedded jointed &pointed with white cement mixed with pigment to match the shade of stone including cutting, rubbing and polishing surface and rounding off edges match laid over and including 20mm thick screed bed in cement mortar 1:6 and including demolition of stone slabs & tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar and removal of rubbish beyond MOD land complete all as specified & directed. |
| 15 | Demolition of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed |
| 16 | Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section unframed work complete all as specified and directed |
| 17 | Dismantling oftimber scantlings,of framed work, from any position & height 40 Sq.cm and over in section complete all as specified and directed.. |
| 18 | M&L exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid 6mm thick complete all as specified and directed by Engr-in-Charge. Note:- frame work for ceiling shall be measured and paid separately. |
| 19 | M&L Anodised aluminumsnap grid frame work of size 605x605mm for false ceiling including hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3mm size 60mm long with complete hanging arrangement and making good at surface all as specified and directed |
| 20 | S&F 18mm thick plywood grade 1 (with BWR resin)fixed with screws to timber frame work with screws to timber frame work as in cupboard, kitchen cabinet etc all as specified and directed |
| 21 | S&F 0.9mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instructions etc all as specified and directed |
| 22 | S & F Aluminium Composite Panel sheet of 3 mm thickwith skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30 micron fixed with suitable Self Tapping Screws over frame work of anodised aluminium tubular section 25 X 50mm, 2mm thick, duly fixed to wall / ceiling with expansion fastener, having panels not exceeding 1200X1200mm with necessary silicon filling, in approved pattern / size as in column, beam, wall etc. complete all as specified and as directed.Note:- Rate quoted is deemed to be included for necessary MS Scaffolding up to a height of 12m from the GL for carrying out the job. Nothing shall be paid extra on this account. Make of Aluminium Composite Panel: ALSTRONG/ALCOBOND/ALSTONE.Make of Aluminium Sections: JINDAL / HINDALCO / INDAL. |
| 23 | Taking down chowkhats or frames with shutters n.exc 1.5 sqm each (without taking off shutters from the frame) and removing to storeall as directed. |
| 24 | S&F box type mild steel windows glazed / gauzed incl frame made of hollow sections 60 x 25 x 1.25 mm thick 50 x 20 mm x 1.25 mm thickMS Hollow pipes as in windows shutter with or with out sash bars incl 150 mm size MS tower bolts 2 No each leaf, MS handle made of Z section 100 mm long 2 Nos each leaf, mild steel cheat 55 mm x 25 mmx 75 mm long 2 Nos each leaf, mild steel cleat 55 mm x 25 mm x 75 mm long, MS Pintel hing 75 mm long 14 mm dia 02 Nos each leaf complete all as specified and directed. |
| 25 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 26 | Taking down chowkhats or frames with shutters exc 1.5 sqm but n.exc 1.5 sqm each (without taking off shutters from the frame) and removing to storeall as directed. |
| 27 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails & MS frame shall be covered with heat moulded plain colour PVC `C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement of stiles and plain colour PVC sheets for top rail,lock rail & bottom rail, on either side & as gap insert for top rail & bottom rail & panelling ofplain colour PVC sheet to be fitted in the MS frame welded/Sealed to the stiles & rails with suitable PVC sheetbeading and joined together with solvent cement, supplying & fixing in the frame at site as per complete all as specified. |
| 28 | S&F solid door frame 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete.all as specified and directed. |
| 29 | S&F Factory made Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid decorative type door/window/ ceosetory windows & other frames / chowkat of size 65mmx125mm compressing of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and naturalfibers (wood powder/ rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement and screwed with full boady threaded star headed SS screws having minimum density of 750 kg/cum and screwwithdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength 58 N/mm2, modulus ofelasticity 900 N/mm2 and resistance to spread of flameof Class A category with property of being termite/borerproof,water/ moisture proof and fire retardant and fixed in position with MS hold fast /Lugs/SS dash fastebers if required dia and length complete all as per direction of Engineer-in-Charge (MS holdfast /lugs or SS dash fasteners shall be paid separately) Note:- for WPC solid door/window frames. minus 5mm tolerance in dimensions on plus side shall be acceptable but no extra payment on this account shall be made. complete all as specified and directed. |
| 30 | Taking downshutters of any description exc 1sqm but not exc 2 sqm each andcomplete all as specified and directed.. |
| 31 | Taking downshutters of any description exc 2 sqm each andcomplete all as specified and directed. |
| 32 | S&F for Anodised aluminium with podwer coating any colour (powder caoting thickness not less then 50microns) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, sliding rollers, handles, locking cleats, snap beading, screws etc.complete all as specified and directed. |
| 33 | S&F for Anodised aluminium with powder caoting thickness not less then 50 micron door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.complete all as specified and directed. |
| 34 | S&F for Anodised aluminium with powder coating not less then 50 microns thickness frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.complete all as specified and directed. |
| 35 | M&L for powder coated aluminium grill in repairs of powder coating of minimum 50 micron with aluminium mesh of sze 50x50mm with square tube solid 6mm thick including aluminium channel of size thickness of channel 1.5mm complete all as specified and directed. |
| 36 | S&F MS square bars as in window guard bars welded to steel window frame or fixed to wooden frame all as specified and directed. |
| 37 | S&F 35mm thick, second class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etcwith rails and styles including cut and mitered beards for securing wire cloth etc,all as specified and directed. |
| 38 | S&F 30mm Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed. |
| 39 | M&L preparation of new wooden surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat ofprimer all as directed and specified. |
| 40 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 41 | S&F100mmmedium weight mild steel butt hinges complete all as specified |
| 42 | S&Fin repairs 50mmmedium weight stainless steel butt hinges complete all as specified |
| 43 | S&F aluminium anodised barrel tower bolt 150mm long extruded section all as specified. |
| 44 | S&F 250mm long aluminium alloy anodised sliding bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts and extruded section or cast aluminium alloy and fixedcomplete all as specified and directed. |
| 45 | S&F 300mm long aluminium alloy anodised sliding bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts and extruded section or cast aluminium alloy and fixedcomplete all as specified and directed. |
| 46 | S&F 150mm size extruded aluminium handles fabricated type anodised complete all as specified. |
| 47 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 48 | Cutting holes in brick walls built in cement mortar for insertinghold fasts and making good dismentled portion in CM 1:3 or cement concrete 1:2:4 type B-I as required, Exc half brick but not exc one brick wall. |
| 49 | M&L for PCC1:2:4 Type B-0 ( 12.5 mm graded aggregate) cement concrete in roof padding,roof kerbs of mud stops, rounded or chamfered on edgescomplete all as spcified and directed. |
| 50 | Supply only Integral water proofing compound complete all as spcified and directed. |
| 51 | Taking down cement plaster on brick or stone walls/ etc including raking out joints, hacking for key, scrubing down with water all as specified and directed |
| 52 | M&L for rendering 10mm thick Ready Mix Plaster on internal surface in cement mortar onbrick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. |
| 53 | M&L for rendering 5 mm thick Ready Mix Plaster onceiling concretesurface in cement mortar, finished even and fair without using extra cement complete all as specified and directed. |
| 54 | M&L preparation of newly plastered surfaceon walls and applying two coat of Oil Bound Distemper over a coat of primer and Puttycomplete all as specified and directed. |
| 55 | M&L for preparing newly plastered surfaces of ceilling and applying three coats of white wash complete all as specified and directed. |
| 56 | M&L forpreparation of old decorated plastered orunplastered surfaces of wall and applying one coats of oil bound distemper including preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds, moss,efflorancr salt , trading oil and greasy spot complete all as specified and directed. |
| 57 | M&L forpreparation of old decorated plastered orunplastered surfaces of wall and applying two coats of oil bound distemper including preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds,filling gaps wth wall care putty, complete all as specified and directed. |
| 58 | M&L for preparation of old decorated previously treated surfaces ofceiling by brooming down scrapping down smoke and efflorescent etc. completeand applying one coat of white wash complete all as specified and directed. |
| 59 | M&L for one coats of synthetic enamel paint on old steel painted surfaces including preparation of surfaces of any description not otherwise descriped over 10 cm width or grithcomplete all as specified and directed. |
| 60 | M&L for one coats of synthetic enamel paint on old wooden painted surfaces including preparation of surfaces of any description not otherwise descriped over 10 cm width or grithcomplete all as specified and directed. |
| 61 | M&L Welding in repairs n. exc 6mm thick metal and n. exc 2.5 cm in length all as specified and directed.. |
| 62 | Repair of Aluminium door/windows shutters with chowkhats area exc. 1.5 sqm but n.exc 3.00 sqm taking down, re-setting easing fixing of cleats screws nut , bolts, fixing of hold fasts, fixing of Aluminium door stopper, change of PVC rubber beadings,complete repair for smooth functioning of door/windows all as specified and directed. |
| 63 | M&L in repairsdouble action floor spring hydraulically regulated made up of min 1.25 mm thick aluminum alloy sheet foundations box main body with stainless steel cover govering pivet made of brass complete all as specificed and directed. |
| 64 | S&F in repairs Aluminium (extruded section body) door closer hydraulically regulated, designation no : 3, universal typeuniver type suitable for door shutter of 851 to 1000mm in width and of weight between61 to 80 kg complete all as specified and directed |
| 65 | S&Fix in repair stainlesssteel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks/stainless steel wire staples all as specified. |
| 66 | S&F in repairs 12mm Thick Toughen glass partitions, Doors,including all fittings and fixtures, necessary Handles, hinges, and knobs etc as per the existing one complete all as specified and directed. |
| 67 | S&F in repairs 10mm Thick Toughen glass partitions, Doors,including all fittings and fixtures, necessary Handles, hinges, and knobs etc as per the existing one complete all as specified and directed. |
| 68 | S&F for 3mm thick ordinary sheet glass and glazing with oil putty complete in squares not exc 0.50 Sqm each pane incl hacking out complete all as specified and as directed. |
| 69 | S&F for4.8mm thick ordinary sheet glass and glazing with oil putty complete in squares exc 0.50 Sqm each pane incl hacking out complete all as specified and as directed. |
| 70 | S&F for 3mm thick ordinary sheet glass and glazing with oil putty complete in squares not exc 0.50 Sqm each pane complete all as specified and as directed. |
| 71 | S&F for4.8mm thick ordinary sheet glass and glazing with oil putty complete in squares exc 0.50 Sqm each pane complete all as specified and as directed. |
| 72 | S&F in repairs Drappery curtain rods decorative type stainless steel 25mm nominal dia of approved quality including fixing oftwo number decorative brackets fixed in brick/concrete wall, Two number of latto on both ends of curtain rods complete all as specified and directed. |
| 73 | Demolition of cement concrete of any description and in any position (unreinforced) in ground floors below or above ground level n.exc 15 cm thick and clearing rubbish from site all as directed and specified. |
| 74 | M&L for 40 mm thick Cement concrete 1:2:4 type B-0 as in floor including surfaces to be finished even and smooth with using extra cement complete all as specified and directed |
| 75 | M&L for Glass dividing strips, 3mm thick and 38 mm widecomplete all as specified and directed |
| 76 | M&L 75mm thick Cement concrete 1:3:6 (40mm graded stone aggregate)in flooring or plinth protection including surfaces to be finished even and smooth without using extra cement complete all as specified and directed. |
| 77 | Disconnecting existing overhead tanks,setting aside or lowered if required for repairing ,cleaning etc and hoisting if reqd reconnecting and refixing in positionbut capacity exceeding 250 litres and not exc 500 litres complete all as specified & directed. |
| 78 | Disconnecting existing overhead tanks,setting aside or lowered if required for repairing ,cleaning etc and hoisting if reqd reconnecting and refixing in positionbut capacity exceeding 500 litres and not exc 1000 litres complete all as specified & directed. |
| 79 | S&F in repair 15mm bore dia Pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure with or without lettered \"Hot or Cold\" with long screwed shank and fly-nuts screwed for iron pipes and fixed all as directed. |
| 80 | S&F in repairs CP brass pillar taps cast copper alloy with capstan heads,chromium plated screwed down high pressure with or without lettered hot or cold with long screwed sank and flynuts screwed for iron pipe of 15 mm bore complete all as specified and directed. |
| 81 | S&F in repair fancy type chromium plated long body bib taps 15mm bore with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed all as directed and specified |
| 82 | S&F in repairs 15mm bore Stop valves fancy type chromium plated, cast copper alloy, screwed down, high pressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions and fixed complete all as specified and directed. |
| 83 | S&F in repair angular stop cock, chromium plated, cast copper alloy C.P 15mm bore screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union all as directed and specified. |
| 84 | S&F in repairs, 15mm bore, bib taps, 2 in 1, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. FLR-5041N or equivelant of make as per list of manufacturer) |
| 85 | S&F in repair 15 mm bore, Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with all accessories complete all as specified and directed. (Make: Jaquar Cat No. ALD-573 or equivelant of make as per List of manufacturer\"s) |
| 86 | S&F in repairs 600mm x 450mm x 5.0mm thick looking mirror bevelled edge of selected quality glass with aluminium frame of channel alround mounted onAC building board or commercial ply woodand fixed to wooden plug with CP brassscrews, complete all as specified and directed. |
| 87 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 88 | S&F in repair vitreous china wash hand basinwhite flat back of size 550x400mm including cutting for and pinning in ends of brackets, PVC flexible waste pipe 32mm dia,brass chromium plated waste fittings, and pedestal etc complete all as directed and spcified. |
| 89 | Supply only waste fittings brass chromium plated 40mm dia for sink completeall as specified and directed. |
| 90 | S&F in repairs Water closet (Squatt pattern) complete including provision of lime/Cement bedding concrete bedding including complete all as specified and directed. |
| 91 | Supply only PVC low level flushing cistern valveless, 10 ltr capacity syphonic action type with inlet ballvalve, float handle including brackets and (HDPE) flush pipe of 32mm dia with brass nut & washer, PVC connecting pipe, etc. connecting with WC inlet and making good the surface to match with existing complete all as directed and specified. |
| 92 | S&F in repair 20mm dia brass CP towel rail600mm long all as specified and directed by Engr in Charge |
| 93 | S&F in repair CP toilet paper holder with flat recessed type stainless steel complete all as specified. |
| 94 | S&F in repairs 15mm bore PVC connection pipe of450mm size with 2 Nos brass check nuts with washerscomplete all as specified and directed. |
| 95 | S&F in repairs fancy type chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe or union complete all as specified and directed. |
| 96 | M&L for Preparation of old surfaces of wall with the help of mechaniser sander of Make Berger Paints express painting sanding machine or equivalent make (having mechanical vaccum machine with bag for dust collection) to make surface smoth and even complete all as specified and directed. |
| 97 | M&L for Providing and applying waterproof cement based putty @ 1kg (undiluted) per sq mtr of average thickness 1mm, of Asian paints or its equivalent over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete all as specified and directed.Step 1 : Mix the putty powder by adding 40-50% water and mix it with Asian Paints Trucare Putty mixer (Trucare Putty mixer with min 1400W power having mixer rod of industrial stell garde 45 with the mixing capacity of min 2.5kg putty per minute).Step 2 : apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application of Asian Paints Trucare Graco Spray Machine (Model: EH 230DI) or equivalent having a DC electric motor of 3.3kW having flow speed of max 6 ltrs per minutes with a maximum pressure 230 bar having maximum tip size 0.041\".Step 3: Allow 6-8 hrs time to dry the putty surface.Step 4 : Sanding of the putty surface with Asian TruCare Wall Sander: L-01/H-01(having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc by skilled labour complete all as specified and as directed |
| 98 | M&L Providing and applyingtwo coats of smooth acrylic emulsion with rich matt finish having voc less than 50 grams per ltr complying leed criteria @ 1ltrs (undiluted)/10Sqm diluted with water in 2:1 ratio applied over priming coatwith fully automatic airless spray machine of paint application of Asian Paints Trucare Garco or equivalent having an electric motor of minimum 1HP with a flow speed of minimum 1ltr per minute having a pressure of 3300psi. Allow 6-8hrs to dry the surface for painting of subsequent quotes. |
| 99 | M&L for preparation of new plastered surfaces of walls and applying two coats of oilbound distemper using Airless spray technology with max working pressure of 3300PPSI and capable of operating single spray gun with a max material hose length of 30mtr the spray machine should be of reputed manufacturer with pro guard technology andcapability of tracking pressure and paint usage and certified by paint manufacturer andas mentioned in PS and accessories for applying distemper should be able to spray inhard to reach areas and penetration of distemper on the surface to achieve excellentapplication using limited manpower complete all as specified and directed.Note: - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, withinternal dust extraction system for clean environment certified by paint manufacturer. |
| 100 | M&L 15mm bore GI tubing medium grade with all fittings and fixed, including taking up or down steel water tubing and connectionsand removal from site15mm bore pipe and complete to walls, ceiling or laid in floor all as specified. |
| 101 | M&L 20mm bore GI tubing medium grade with all fittings and fixed, including taking up or down steel water tubing and connectionsand removal from site15mm bore pipe and complete to walls, ceiling or laid in floor all as specified. |
| 102 | M&L for Cutting chases, pinning in Brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and ctting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed. |
| 103 | S&F in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, fixed to walls with clamps etc,bore of pipe 75mm complete all as specified and directed. |
| 104 | S&Fin replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints,fixed to walls with clamps etc,bore of pipe 100mm complete all as specified and directed. |
| 105 | S&F cast iron bends (sand cast) (any radius), diminishing pieces or tapers soil/waste pipes 75mm in any length (larger bore measured) complete all as specified and directed. |
| 106 | S&F cast iron bends (sand cast) (any radius), diminishing pieces or tapers soil/waste pipes 100mm in any length (larger bore measured) complete all as specified and directed. |
| 107 | S&F 100mm cast iron branch pieces,double (equal or unequal),ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors as in door \"T\", door bends, \"Y\" section complete all as specified and directed. |
| 108 | M&L forpreparation of old decorated plastered orunplastered surfaces of wall and applying one coat of plastic emulsion paintincluding preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds, moss,efflorancr salt , trading oil and greasy spot complete all as specified and directed. |
| 109 | Demolition and breaking up drain pipesany sizeset in cement mortar incl all fittings up to 4 floors height including necessary scafolding or mechanical arrangements by contractor complete all as specified. Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates. |
| 110 | S&F 110 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floors complete all as specified. Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates. |
| 111 | S&F 75 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floors complete all as specified. Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates |
| 112 | S&F 110mm dia PVC SWR bends of any radius with out access door up to 4 floors height including necessary scafolding or mechanical arrangements by contractor complete all as specified and as directed Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates |
| 113 | S&F 110mm dia PVC (SWR) junction single \"T\" equal or unequal with access door Complete all as specified and as directed. Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates |
| 114 | S&F 110mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal Complete all as specified and as directed. Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates |
| 115 | S&F 75mm dia PVC (SWR) junction single \"T\" equal or unequal with access door Complete all as specified and as directed. Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates |
| 116 | S&F 75mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal up to 4 floors height including necessary scafolding or mechanical arrangements by contractor Complete all as specified and as directed. Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates |
| 117 | S&F 75mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed. Note:- Work will be executed upto 15 mtr height neccessary scaffolding arrangements is included in quoted rates |
| 118 | Removing the plant/growth of any description size, any location of external surfaces of walls shafts by cutting& remvoing the roots completely spraying the suitable chemical (each plant 100 ML) in the removed portion to avoid re-growth & making good damaged portion to match the existing surfaces by PCC type B0 (1:2:4)12.5 mm graded aggregate complete all as directed by Engr In Charge. (Chemicals : Gramzone/Roundup or equivalent suitable to remove/destroy the plants/roots) |
| 119 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as Specified. |
| 120 | M&L Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 121 | S&F in repairs 500 ltrs capacity three layer rotational molded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted ofand fixed in position including, dismantling existing water tanks etc all as specified and directed. |
| 122 | S&F in repairs 1000 ltrs capacity three layer rotational molded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted ofand fixed in position including, dismantling existing water tanks etc all as specified and directed. |
| 123 | S&F in repairs 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 124 | S&F in repairs 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 125 | S&F in repairs 15mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 126 | S&F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified. |
| 127 | S&F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified. |
| 128 | Dismantling of plain or corrugated asbestos cement sheeting from roof coverings including ridge complete all as specified and directed |
| 129 | M&L for post construction of Anti Termite treatment At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 l itre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same |
| 130 | M&L for post construction anti termite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 131 | M&L for post construction anti termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 132 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mmthick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note:- stainless steel butt hinges and necessary S S screws shall be paid separately) complete all as specified.Factory made single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail