| 1 | M&L for RCC M25 (Design Mix) using 20mm graded crushed stone aggregate for column complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for form work for fair finished surfaces of concrete measured flat for column complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (footing & column upto NGL) complete all as specified and directed by Engineer-in-Charge. |
| 4 | All as per item No 03 above but 5 to 10mm dia in stirrups, spacers & binders complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for RCC- M25 (Design Mix) using 20mm graded crushed stone aggregate for roof beams etc complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L for form work for rough finished surfaces of concrete measured flat for roof beams complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L for RCC M-25 (design Mix) using 20mm graded crushed stone aggregate for roof slab complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for form work for rough finished surfaces of concrete measured flat for roof slab complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge. |
| 10 | Dismantling/Removing of loose plastered, labour for carefully dismantling entire plaster around the main columns using manual or mechanical means. Chipping hammer not to exceed 15-lb class. Central core column not to be disturbed while dismantling plaster. Prices inclusive of all tool tackles, safety requisites etc. as per instructions and disposing off the waste upto a lead of 50m as per instructions complete all as specified and directed by Engineer-in-Charge. |
| 11 | Polymer Modified Cementitious Grout: Core Strengthening of members by filling cracks, voids, porous delaminated concrete by injecting SBR Polymer Modified Cementitious non shrink, viscous, fast setting grout under a pressure of 20-30kg/cm2 including providing Stainless Steel/Aluminum nozzles/nipples of appropriate length, drilling of holes, cleaning them, inserting and fixing of nozzles/ nipples with approved fixing compound or epoxy putty in columns with portions not greater than 200mm, structural clay to seal the cracks to prevent oozing etc. complete as per specified steps and product specifications. Subsequently cutting/removal of nozzles /nipples as necessary aftercompletion of grouting and sealing the same by epoxy putty as per technical specification inclusive of all labour, materials, equipment, steel props and supports to release load etc complete all as specified and directed by Engineer-in-Charge. |
| 12 | Polymer modified cement mortar:- Providing and applying prepacked polymer modified mortar (Sikka,Fosroc,BASF) with addition of Owens Corning Cem-Fil Anticrack HD12 Glass Fibres (@0.6 Kg/Cm3) to the damaged slab. Apply bond coat of SBR polymer based cement sulrry (same pre paked material) shall be brush applied to the concrete as well as steel surface, the subsequent 15-40mm thick application of polymer modified mortar must be applied before the bonding coat is hard set. The details/instructions of preparing of the polymer modified mortar to follow product specifications. Proces inclusive of all labour, materials equipment, safety requisites etc. complete safety requisites etc. complete all as specified and directed by Engineer-in-Charge. Note:- Surface area of the slab shall be measured for payment purpose |
| 13 | Carbon fiber wrapping: Strengthening structural element columns with nonmetallic composite fiber wrapping systems comprisedofu ni-directional GLASS fiber sheet (200GSM) inone layer and compatible saturate including surface preparation by grinding/moulding concretesubstrate, cleaning it withwirebrush, etc. applying compatible primer on prepared substrate, filling the uneven surfacewith thixotropic putty , mechanizedwetting of fiber sheet, inclusive of all labour, materials equipment etc as per specification and instruction complete all as specified and directed by Engineer-in-Charge. |
| 14 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing servicable tiles to store and rubnbish of the permises complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L for light shade vitrified tiles flooring 9-10mm thick (square/rectangular), polished, area of each tiles not exc 0.36 sqm, in floors and skirting etc set and jointed in net slurry and pointed in white or coloured cement to match existing shedincluding 15mm screed bed in cement mortar 1:6complete all as specified and directed by Engineer-in-Charge. |
| 16 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for 10 mm thick rendering in cement mortar 1:6 fair faces of brick or concrete surfaces, including finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 18 | M&L for preparation of newly plastered or unplasteredsurface andproviding and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth (multi purpose mixer shall be used for uniform and proper mixing of putty) Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour in two coatsover a coat of primer complete, as per manufacturer\"s specification. by auto roller complete all as specified and directed by Engineer-in-Charge. |
| 19 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finishing even and smooth without using extra cement withwater proofing compound complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply only liquid integral water proofing compound complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L for preparation of new plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint (in camouflage pattern) over a coat of primer complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for rendering 5mm thick in cement mortar 1:3 as on ceiling surfaces complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for preparation of new plastered surfaces of Wall and applying three coats of white wash on ceiling complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for preparation of old surfaceremoval of nails etc & filling cracks/holey) and applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour in two coats complete, as per manufacturer\"s specification. by auto roller complete all as specified and directed by Engineer-in-Charge. |
| 25 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laidbedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for 25 mm thick, PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub base over RCC slab complete all as specified and directed by Engineer-in-Charge. |
| 27 | M&L for 75 mm thick, PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for sand cushioning under floors or in foundations including watering and consolidation ccomplete all as specified and directed by Engineer-in-Charge. |
| 29 | M&L for 60 mm thick machine pressed precast concrete interlocking paver block any shape and sizeM-35 grade with grey cementand no pigment confirming to IS 15658-2006complete all as specified and directed by Engineer-in-Charge. |
| 30 | Taking down and refixing in same openingchowkats with shutters (without taking off shutter from the frame) of any description exc 1.5 sqm and not exc 4.0 sqm each complete all as specified and directed by Engineer-in-Charge.Note : The rate includes for taking down, easing and adjusting and also fixing new builders hardwares as required including replacement of unserviceable screws etc. |
| 31 | Demolition ofreinforced cement concrete (reinforcementcut as requiredto facilitatedemolition)of roofs,floors (other than ground floor) beams, staircase, landing, chajjas and simiolar work complete all as specified and directed by Engineer-in-Charge. |
| 32 | Demolition of concrete (unreinforced) and pavings not exc 15 cm thickness (below orabove ground level) complete all as specified and directed by Engineer-in-Charge. |
| 33 | M&L for cement concrete(1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in bed plates, coping, kneelers, lacing courses,plinth courses etc including necessry formwork etc complete all as specified and directed by Engineer-in-Charge. |
| 34 | M&L for point wiring with two single core 1.5 sqmm cable (nominal area) stranded copper conductor, PVC insulated unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia with sunken type pressed steel terninal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer andtwo coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes including all accessories and using single core 1.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unsheathed cable as in earth wire (green colour) connected to common earth dolly complete all as specified and directed by Engineer-in-Charge for following :- (a) One light point controlled by one switch. |
| 35 | (b) All as per item No 34abocebut one 3 pin switch socket outlet point 5 Amps on same board complete all as specified and directed by Engineer-in-Charge. |
| 36 | (c) All as per Item No 34 above but one 3 pin switch socket outlet point 5 Amps on independent board complete all as specified and directed by Engineer-in-Charge. |
| 37 | All as per item No 34 above but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size complete all as specified and directed by Engineer-in-Charge. |
| 38 | S&F single pole and neutral enclouser with two pin and earth plug and socket complete with one single pole 20 Amps MCB , 230 Volts complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for switch piano flushtype single pole, one way 5 Amps 230 Volts AC circuit complete all as specified and directed by Engineer-in-Charge. |
| 40 | M&L for switch piano flush type single pole, one way 15 Amps 230 Volts AC circuit complete all as specified and directed by Engineer-in-Charge. |
| 41 | M&L for socket outlet 5 Amps, 5 Pin flush type multipurpose, 230 Volts AC circuit complete all as specified and directed by Engineer-in-Charge. |
| 42 | M&L for socket outlet 2 in 1, 3 Pin 5 & 15 Amps, 230 Volts AC circuit complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F for ceiling rose surface backlite 65x50mm 3 terminals complete all as specified and directed by Engineer-in-Charge. |
| 44 | S&F for electronic step type fan regulator 120 Watt 230 Volt 50 Hz two module C/S deluxe type complete all as specified and directed by Engineer-in-Charge. |
| 45 | M&L forsubmain wiring with two single coreFRLS insulated flexible copper conductor cable of sze 4 sqmm and one single core PVC FRLS insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F sheet metal enclosure MCB distribution board. Single pole & neutral 230 Volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply and replacement MCB single pole 230 Volts any rating from 6 to 32 amps, with reupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply and replacement MCB SPN230 Volts any rating from 32 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge. |
| 49 | S&F LED Street light fitting 35 Watt 230 Volt AC Outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrission resistant including thermal management in multiple optics complete with IP 66/65 protection complete all as specified and directed by Engineer-in-Charge. |
| 50 | Taking down and refixing AC of capacity 1.5/2.0 Ton in same place and including all accessories for fitment which is required at site complete all as specified and directed by Engineer-in-Charge. |
| 51 | S&F in repair wall mountedLED Tube light fitting 20 Watts 6500K including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting in position at site on 02 Nos newround blocks including complete all as specified and directed by Engineer-in-Charge. |