| Sl. No. | Item Description |
| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and ramming earth or brocken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L Cement concrete 1:3:6 type C2 (using 40 mm graded aggregate) in foundations, filling and mass filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 3 | S&F of MS tubular pipe for tensile structure of any type and size including special shaped washet etc complete using ERW conforming to IS 1161-1998 gd St 240 as specified including clits, ms plate with fabrication, erection and 2 coat of vehicle grade enamel spray paint including preparation of surface, of any description over 10CM width or girthnot otherwise described over one coat of red oxidecomplete all as specified and directed by Engr-in-Charge. |
| 4 | Providing & fixing of Tensile Fabric(fabric of passing minimum criteria that is total weight 900GSM Sattler Pro-Tex Architecture Type 2 Serge Ferrari AdvanceFabric, tensile strength over frame. The Fabric shall be installed, tensioned using a tensioning device and shall not sag at any point. The fabric will be fixed on the frame with fixing accessories like SS Plates Wire SS Fitting aluminum section with powder coated top covers, self drilling screws complete all as specified and directed by Engr-in-Charge.Scaffolding & Civil Work :- All scaffoldingrequired for the erecting of structure fabrics and Civil works required at site for anchoring/ strengthening of structure , shall be arranged by Contractor and included in quoted rate |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard dense soil etc complete all as specified and directed by the Engr-in-Charge. |
| 6 | M&L for PCC 1:4:8 type D-2 as in foundation incuding formwork etccomplete all as specified and directed by Engr-in-Charge. |
| 7 | M&L brick work with sub class \"B\"brick straight or curved on plan exc 6m mean radiusbuilt cement mortar 1:4 complete all as specified and as directed |
| 8 | Demolition of brick workbuilt in cement mortar and other complete all as specified and directed |
| 9 | M&L for Reinforced cement concrete (nominal mix) in Type B1 1:2:4(20 mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span including necessary formwork as required complete all as specified and as directed by the Engr-in-Charge. |
| 10 | S&F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engr-in-Charge. |
| 11 | Ditto as per item No 10 above, but 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by the Engr-in-Charge. |
| 12 | M&L for rendering 10mm thick on fair faces of wall even and smooth finish without using extra cement onconc/brick surfaces in CM 1:6, complete all as specified and directed by the Engr-in-Charge. |
| 13 | M&L for rendering 15mm thick on fair faces of wall even and smooth finish without using extra cement onconc/brick surfaces in CM 1:4, complete all as specified and directed by the Engr-in-Charge. |
| 14 | M & L for Preparation of new plastered surfaceof wall and applying two coat of OBD over a coat of putty complete all as specified and as directed. |
| 15 | M & L for applying two coats of 100%Premium acrylic plastic emulsion paint on new surface having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfacesincluding prepration of new surface complete all as specified and directed by Engr-in-Charge. |
| 16 | Supply & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture (With Semi perforated 4mm thick micro tegular edged GRG false ceiling tiles) , design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge. |
| 17 | M&L, aluminium powder coated aluminiumframe for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by the Engr-in-Charge. |
| 18 | M&L foraluminium powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. S & F 5.5 mm thick tinted glass in panel of shutter fixed with glazing clips , rubber gasket and powder coated aluminium snap beading so as to make air tight and including S & F powder coated butt hinges type C-1,100 mm size 3 nos per shutter , powder coated aluminium handle of 150mm size 2 Nos (One on each side of shutter) , powder coated aluminium tower bolt of size 200 mm ( 2 Nos ) per shutter ,mortise lock , brass body ,6 levers ( 1 No) with duplicate keys, aluminium (extruded section) hydraulic door closer regulated designation No-3 Universal type ( 1 No) & Floor door stopper ( 140 mm ) overall ,aluminium body 1 No on each shtteretc complete all as specified and as directed. Note: (i) Cost of all fittings & fixture shall deemed to be included in unit quoted rate by the tenderer . (ii) The minimum thickness of powder coating shall be 50 Micron complete all as specified and directed by the Engr-in-Charge. |
| 19 | S & F powder coated anodised aluminium sliding window/ventilator shutter three track section for frames of weight not less then 1.17 kg/Rm and sliding section for shutter frame all round with aluminium section of weight not less then 0.42 kg/Rm top and bottom rail of shutter of weight not less than 0.368 Kg/m in two pannels and shutter with including necessary aluminium fittings and 5mm thick selected quality tinted glass and third one with and incl stainless steel wiremesh etc cover aluminium decogrill as approved by GE fixed with standed aluminium channel out side with incl handle cleat, glazing clip special auto lock dry set rubber gasket complete all as specified and as directed by the Engr-in-Charge. |
| 20 | S&F for 15mm toughned forausted glass as in partitions and similar work including cutting to shape, drilling holes required channel for partion all other connected items as required for fixing and etc inclduing taking down wooden partition/any other completed all as specified and directed by Engr-in-Charge. |
| 21 | S&F 15mm toughned glass as in hinged doors, doors and similar work including cutting to shape, drilling holes required channel for partion all other connected items as required for fixing and2 Nos stainless steel handel, locking arrangment, etc completed all as specified and directed by Engr-in-Charge. |
| 22 | S&Fdouble action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty completed all as specified and directed by Engr-in-Charge. |
| 23 | Dismantling plain or corrugated steel sheeting , any gauge thickness including Nanital or similar pattern roof covering complete all as specified and directed by the Engr-in-Charge. |
| 24 | S&F Pre-Painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour havimg testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed. |
| 25 | Dismantling wrought iron or mild steel work of any description not otherwise provided completeall as specified and as directed. |
| 26 | S&F forSteel work in tubular post, purline, rafters etcincluding special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified and directed by the Engr-in-Charge. |
| 27 | M & L for two coat of synthetic enamel paint over one coat of red oxide, zinc chrome primer on steel surfaces, surfaces of any description , over 10cm width or girth not other wise described ccomplete all as specified and directed by the Engr-in-Charge. |
| 28 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises andcomplete all as specified and directed by the Engr-in-Charge. |
| 29 | M&L for screed bed or bedding layer in CM 1:6, 15mm thickcomplete all as specified and directed by the Engr-in-Charge. |
| 30 | M&L, for PCC 1:2:4 type B-0 using 12.5 mm gradesd stone agg as in levelling course of floors of 25 mm thick completecomplete all as specified and directed by the Engr-in-Charge. |
| 31 | M & L rendering 10mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces as in vertical surfaces for receiving tiles as complete all as specified and directed by the Engr-in-Charge. |
| 32 | M&L forvitrified dark coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.36 sqm but not exc 1.00 sqm, in floors etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match to floor etc complete all as specified and directed by the Engr-in-Charge. |
| 33 | M&L forvitrified dark coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.36sqm but not exc 1.00 sqm, in dado/Skirting etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match to floor etc complete all as specified and directed by the Engr-in-Charge. |
| 34 | M&L for 15-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick in CM(1:6) etccomplete all as specified and directed by the Engr-in-Charge. |
| 35 | M&L, 200 mm thick soling or sub base with broken boulders or quarried stone, inter stices filled, surface formed and rollled and consolidated to required camber and gradientcomplete all as specified and directed by the Engr-in-Charge. |
| 36 | Supply, installation, commis-sioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzcomplete all as specified and directed. |
| 37 | M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 38 | M&L for single pole and neutral enclosure with a two pin earth plug & socket complete with one single pole with MCB |
| 39 | Single pole and neutral enclosure with a two pin earth plug & socket complete with one single pole with MCB complete all as specified and directed. |
| 40 | Supplying, laying, jointing & commissioning in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, (Earthed) cross sectional area 95 sqmm 3 core as per IS 7098 Pt-II including connecting with panel of suitable size aluminium lugs/thimble complete all as specified and directed. |
| 41 | Supplying, laying, jointing & commissioning in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, (Earthed) cross sectional area 240 sqmm 3.5 core as per IS 7098 Pt-II including connecting with panel of suitable size aluminium lugs/thimble complete all as specified and directed. |
| 42 | Supply and laying1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 50 sq mm 3.5 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 43 | Supply and laying1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 70 sq mm 3.5 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 44 | Supply and laying1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 25 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 45 | Supply and laying1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 16 sq mm 2 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 46 | Supply and laying 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 150 sq mm 3.5 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 47 | Supply and laying 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 185 sq mm 3.5 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 48 | Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in hard/dense soil complete all as specified and directed. |
| 49 | Excavation in trenchesexc 1.5 mtr wide and n. exc 3.0 mtr depth for pole / cable / foundation etc including getting out in hard/dense soil complete all as specified and directed. |
| 50 | Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed. |
| 51 | Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directedat a level not exc. 1.5 mtr above the ground level complete all as specified & directed. |
| 52 | M&L for PCC 1:4:8 type D2 (using 40 mm graded stoneaggregates) forfoundation filling and bed concrete all as specified. |
| 53 | M&L for PCC 1:2:4 type B-2(using 20mm graded stone aggregates) as in coping etc including form work for polesincluding taking down of u/s existing HDPE pipes all as specified and directed by Engr-in-Charge. |
| 54 | Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 63mm, inner dia 50 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge. |
| 55 | Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 90 mm, inner dia75 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge. |
| 56 | M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed.Note : Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I. |
| 57 | Supply & laying in trenches unreinforced precast concrete cable cover, class HV type-I flat, size 300x180x40mm for cable protection complete all as specified and as directed. |
| 58 | M&L for GI tubing (light grade) with all necessary fittings laid in trenches under road crossing fixed on poles, wall under floor etc. of 80 mm dia bore complete all as specified and directed. |
| 59 | M&L for GI tubing (light grade) with all necessary fittings laid in trenches under road crossing fixed on poles, wall under floor etc. of 40 mm dia bore complete all as specified and directed. |
| 60 | M & L for cutting of road up to 0.75m deep suitable for laying underground cable/MS tubes of any size/dia including GI pipe of 50mm dia and making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50mtrscomplete all as specified and directed. |
| 61 | S&F in replacement of new generation energy saving and environmental friendly long lifeLED security/ street light fittings made up of toughened glass innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 90 watt colour white complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including replacement of twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from junction box to light through connectors complete as specifiedand as directed. |
| 62 | S&F in replacement kiosk box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded andcover with hinged door, pole mounting type comprising of four pole copper connectors of 16 Amps capacity with 6 Amp MCB single pole , of minimum size 300x200x125mm,fixed on pole with MS, clamps 30 x 5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over ared oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed. The quoted rate also includes cost for material & repalcement of 4 sqmm multistranded twincore aluminium cable ISI marked from overhead conductor to junction box and replacement of 3 core copper cable of 1.5 Sqmm ISI marked from junction box to security light length as per required at site. Make-Syntex/Supreme/Hensal |
| 63 | S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 40 mm dia, medium grade,1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles / PCC pole as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed. |
| 64 | S&F of cable jointing Kit 11 KV (earthed) grade cable for outdoor type end termination indor & outdoor type heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed. |
| 65 | Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-55) 11 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided withtwo coats of aluminium paint overone coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. |
| 66 | M&L for switch air break gang operated triple pole polymer type, mechanically operated mounted onHT insulators (12 insulator type) and MS steel framewith operating mechanism worked from ground level with 11 KV insulation for current rating up to 200 amps 11000 volts with locking arrangement, MS clamps, nuts, bolts and washers etc also incl drop out expulsion type fuse, single pole up to 25 Amps, 11000 volts fuse barrels, incl two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed. |
| 67 | Supply and fix Lightning arrestersexpulsion typecomplete with allfittings, transmissionclass, dischargecapacity 65 kilo Ampcomplete all as specified and as directed |
| 68 | S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed |
| 69 | M&Lfor PCC platform for the transformer of size 2m X 2m X 1.5 m with the following :-(a) PCC (1:4:8) type D-2 with 40 mm grade crushed stone aggegate 15 cm thick in foundation.(b) Brick work in CM 1:6 with sub class \"B\" old size bricks(230 mm thick walls) in periphery platform.(c ) 100 mm thick PCC flooring (1:3:6) type C-1 using 20mm graded stone aggregate on top reinforced 12 mm dia MS bar 100mm c/c including use and waste of form work.(d) Rendering 15 mm thick in CM (1:6) on exposed surfaces as well floor surface.(e) The platform shall be such that its height 1.5 mtr above the nearest road level and 45 cm below ground complete all as specified and directed.Note:- Cost of construction of PCC foundation included in the quoted rate. |
| 70 | M&L MS angles as in fencing post, strut cutting tops in shape including all necessary drilling,notching and reveting etc and similar work confirming Fe-410-W(Gde-E-250) quality-B, complete all as specified and directed. |
| 71 | M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and struts in fencing including cutting and making shapes as desired, drilled holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilled, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed. |
| 72 | M&L for chain link MS galvanised fencing including lines wires, dia of chain linking less than 3.5 mm any mesh any size any type to any type strands rails,straining bolts etc. complete all as specified and directed. |
| 73 | S&F mild steel screw bolt(mechine made) with hexagonal or square,head, but length of bolt exc 5cm but n exc 10cm long Complete all as specified and directed. |
| 74 | M&L for prepration of steel Surface of one coat of red oxide and two coat of synthetic enamel paint any description, n exc 10 cm in width or grith when unconnected with other painting or when painted in a different, complete all as specified and directed. |
| 75 | M& L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 76 | M&L for earthing complete with galvanised steel earth plate electrode of size 600X600X6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below the ground level connected to galvanised iron strip of 32 x 6 mm as earth lead by means ofbolts nuts check nuts & washers of galvanised iron or steel ,surrounded by charcoal of coke and salt,water pipe 20mm bore GI medium grade with funnel and wire mesh,and making chamber of PCC (1:4:8) type D-2 using 40 mm graded stone aggregate and coping shall be in PCC(1:3:6) type C-1 using 20 mm graded stoneaggregate, 50 mm thick cover of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia TMTbars @ 80 mm c/c boath ways including excavation and earth work and removal of surplus soil todistance n exc 50 m complete all shown in electrical plate No 3of SSR part- 2010 complete all as specified and directed.Note :-(i) The cost ofGI earth lead & G Ipipe of 7.50 mtr length for protection of GI wire and excavation work for pit shalldeemed to be included in this item. (ii)Earthing test will be carried out and if desired result not achieved and the earthing will be redone to achieve desired result without any extra payment. (iii)Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate. |
| 77 | Supply ,commissioningandtestingfactory madeLTfeeder pillar, outdoortypefloor mounted ,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of3.15 mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangementand consisting of the followingcomplete all as specified and directed. (a) Aluminiumbus barfour strips 600 Amps ,415 volts,fixed on epoxy insulated with panel fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set. |
| 78 | Incoming:- (b) Incommer MCCB,04 Pole, 400 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No(Ics=Icu=100%)Outgoing:-(c ) Out going MCCB,04 Pole, 200 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 04 Nos(Ics=Icu=100%)(Make :- Havells/L&T/schnider/ABB) (d) MCCB,04 Pole, 160 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 Nos(Ics=Icu=100%).(e)Spare way for MCCB 63 Amp 4 way - 01 Nos (g) Analoge type volt meter 0-500 volt- 1Set. (h) Indication lamps R,Y,BLEDtype with 3 Nos– 1 set:-(f) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s. Note :- Panel drawings & make of MCCB/SDFU will be submitted by contractor for approval from Accepting Officer before ordering the panel. |
| 79 | S&F in replacementtesting , commissioning of outdoor type bus barpanel padestal type weather proof CPRI aproovedMS cubical panelboard made of3 mm CRCA MS sheet outdoor type of size 100 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 300 Amp capacity with MCCB 4 pole of Capacity 200 Amp 25 KA (Ics =Icu=100%) 40x40x4mm thick angle iron base frame work,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side including one coat of redoxide and two coat of enamel paint powder coated, mounted on mild steel channel of suitable size andPCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,, aluminium bus barchanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. LTPanel board should be as per IS/IEC 61439-I: 2011 &IS/IEC 61439-2 : 2011, Type Test certificates for Short Circuit Test, Temperature Rise Test, Di-ElectricProperty Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. Note :--02 Nos for JCO\"s Block, 02 Nos for NCO\"s Block, 01 No for NCE\"s Block |
| 80 | Taking down carefully copper/ aluminium point wiring (light, fan, socket, or power) complete fitting such as switches, ceiling roses pendants, regulators, sockets, light fitting ceiling fan etc to be measured seperately ) removing materials for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperatly) and making good disturbed surface of walls floors etc all as specified and directed. Note-Responsibility after taking down fan/exhaust fan keep in safe custody of contractor and refix the same afterbefore completion of work the rate of same deemed to be included in the item quoated rate. |
| 81 | Taking down carefullyexisting wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size anycapacity fromboards completeall as specified and as directed. |
| 82 | Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed. |
| 83 | M & L for concealed point wiring for one light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.6mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dollywith3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green multi stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed . |
| 84 | Ditto all as per item No 83 above but One 3/5 pin5 Amp socket outlet point controlled by one switch on independent board. |
| 85 | Ditto all as per item No 83 above but One 3/5 pin5 Amp socket outlet point controlled by one switch on same board. |
| 86 | Description all as per item No 83 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. |
| 87 | S&F modular socket 20 amp with MCB 20 Amp \"C\" type all specified and complete. (For geyser) |
| 88 | S&F Modular switch 1 way 6 A,1 module complete all as specified and directed. |
| 89 | S&F Modular Socket, 6A - 2/3 pin combined 2 module,complete all as specified and directed. |
| 90 | S&F Modular switch 1 way 16 A,1 module complete all as specified and directed. |
| 91 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 92 | S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. |
| 93 | M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 94 | S&F sheet metal enclosure double doorconcealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 8 ways 240 V complete all as specified and as directed . |
| 95 | S&F MCB single pole and neutral 40 Amp / 63 Amp 240 V ,10KA , \"C\" series, complete all as specified and as directed with copper lugs complete all as specified and as directed . |
| 96 | S&F MCB single pole 6 to 32Amps 240 V,10KA, \"C\" series,complete all as specified and as directed |
| 97 | S & F in replacement of decorative wall mounting ,champagne gold finish( STYLO ) fixturewith plastic body diffuser including LED Bulb 10 Watts complete all as specified as directed .Make Havells/Bajaj/Wipro/Phillips /Benlo |
| 98 | S&F in replacement of LED tube light fitting warm white high out put diffuser 22 watt 220 V AC 3000 K decorative type polycarbonate body with driver including connecting up to existing/ new celing rose of suitable size complete all as specified and directed .Make Bajaj/Havells / Crompton/Phillips/Wipro/Benlo |
| 99 | Supply and fix LED 35/36 W building security light fitting,5700 K energy saving & environmental friendly long life versatile pressure die cast aluminiumIP 66.road way luminare with high power LEDs as light source and electronic driver suitable for pole dia 35 mm including 35 mm dia light grade tube bracket ,bend to shape 1.80 mtrlength with two nos of clamps of size 50mm x 6mm with nuts and bolts,washers etcincluding connection with 1.5sqmm threesinglecorePVC insulated and PVC sheathed cable stranded copper cable upto ceiling rose and fixing on walls/pole complete all as specified and directed. |
| 100 | S&F in replacement of 36 Wwarm white 2 feet X 2 feet LED Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling in MS housing with high brightness LEDs incl wiring upto and terminating into existing / new ceiling rose complete all as specified and directed .Make Crompton/Havells/Bajaj/Anchor panasonic/Benlo |
| 101 | S&F of wall /Cabinet fan for wall /Cabinet fan of Size 300 mm sweep,100-120 Watt , 230 V,50 Hz,minimum 2100 RPM to ISI markedcomplete all as specified and directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail