| 1 | Excavation in trenches, not exceeding 1.5 M wide, and not exceeding 1.5 M in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Returning & filling of the excavated earth including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils. complete all as specified and directed |
| 3 | Removing Excavated soils n. exc 50 mand depositing where directed at a level not exc 1.5 mabove the starting point. complete all as specified and directed |
| 4 | M&L for mild steel TMT bars 10 mm dia and over, cut to length and bent to shape required and binding with mild steel wire dia not less than 0.9 mm (annealed) complete all as specified complete all as specified and as directed. |
| 5 | All as per item No 4but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binderscomplete all as specified complete all as specified and as directed. |
| 6 | M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in foundation, including raft, footings, foundation beam, plinth beam bases for columncomplete all as specified and directed. |
| 7 | M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in Column pillrs piers complete all as specified and directed. |
| 8 | M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in roof slab supported on walls beam and columns in floors, lintelscomplete all as specified and directed. |
| 9 | M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in beams, cantilever, ressummeers ,lintels over 1.5 span complete all as specified and directed. |
| 10 | M & L for Formwork to sides of concrete foundation,footings, bases of columns, raft and raft beams sides and soffits (if any) of foundationand plinth beam and similar work vertical or to batter for rough finished surface of concrete etc. complete all as specified and directed. |
| 11 | M & L for Formwork to soffits of suspended slabs such as roof slab, floor slabs, labdingand similar work . complete all as specified and directed. |
| 12 | M & L for Formwork to soffits of floor or roof beam, beam haunching, girders, lintels, cantilivers, shelvesincluding supports, overhang, etc. also splays between floor and beams, for rough finished surface of concrete etc. complete all as specified and directed. |
| 13 | M & L for Formwork to soffits of pillar, posts struts, peiers , columns and stanchion , for rough finished surface of concrete etc. complete all as specified and directed. |
| 14 | M&L forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM1:6 complete all as specified and directed |
| 15 | M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick Walls or on Concrete Surfaces, mixing WPC as per manufacturers instructions, Plastered Surfaces finished Fair and Even, complete all as specified and as directed.NOTE: WPC will be Measured and Paid under appropriate Item. Areaincludes in this items upto 4 stories of building. |
| 16 | M&L for rendering 15 mm thick onbrick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extracement complete all as specified and directed. |
| 17 | M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces on ceiling/ struts inpatches in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed. |
| 18 | Supply only integral water proofing compound. |
| 19 | M&L for2mm thick birla white putty and making the surface smooth etc complete as specified and directed |
| 20 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfacesincluding preparing old Decorated/Treated Plastered surfaces of Walls by Complete Removal of existing Treatment and by applying 2mm thick plaster of paris Wall Putty, cutting/ rubbing to obtained a Smooth Surface complete all as specified and as directed. |
| 21 | S & FProviding and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated),steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.Area not exceeding 2.00 sqm each.((Note: The unit rate quoted by contractor includes cost of glass andall other connected accessories. Net opening will be measured for payment purpose.) |
| 22 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be include in the quoted lum sum). →Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 23 | S & FFactory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borerproof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be included in the lumpsum quoted by the contractor. |
| 24 | S&F framed work such as grills, gratings, etc.. with ends of barsshouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walkways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 complete all as spefied and directed by Engr-in-charge |
| 25 | M&L for Polish Glazed Vitirified Ceramic Tiles 10mm thick (Square/Rectangular),Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Floors, etc. set and jointed in Neat Cement Slurry and pointed in White or Coloured Cement to match the Tiles, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 26 | M&L for Polish Glazed Vitirified Ceramic Tiles 10mm thick (Square/ Rectangular)Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Vertical Surface i.e. Dado, Skirting,etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick rendering in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Mortar shall deem to be include in the Quoted Unit Rate. |
| 27 | M&Lfor 75 mm thick cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate in sub base all as specified & directed by Engr -in charge |
| 28 | M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in floor finishingcomplete all as specified and directed |
| 29 | M & L broken brick bats as in foundation for Loose filling with aggregates of gauge 40 to 80mm complete all as specified and as directed. |
| 30 | M&L for granite (Black) stone slab 15-18mm thick machine cut and machine polised, in skirting, Kitchen platform/dado,in floor etc laid over cement screedjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding the edges half round and polishing including pinning in brick/concrete wall to hold & support the vertical surfaces to granite work including drilling to wall & including screed bed 15 mm thick in cement mortar 1:4 complete all as specified and as directed by Engineer-In- Charge. |
| 31 | Dismantling Structural Steel or Mild Steel Work of any description including Framed Truss, etc., complete all as specified and as directed. |
| 32 | M&L Steel Work in Tubular Trusses including Special shaped Washer etc. complete using ERW or Induction Butt Welded Tubes, confirming to IS-1161-1979 Grade-240, complete all as specified and as directed. |
| 33 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 34 | M&L Fibre Glass Reinforced Translucent Corrugated Sheeting 2.0mm thick with 20 Cm Side Lap and 15 Cm End Lap, fixed with Coach Screw and Washer in Roof, Walls, etc., complete all as specified and as directed. |
| 35 | S&F PVC Wall Panneling for 5 to 7mm hollow printed in any colour PVC sheet inclusive of solvent cement and fixing at site on PVC Frame as per specification complete all as specified and as directed.Note : Design /Pattern will be selected byGE/Engr-in-Charge. |
| 36 | S&FStainless Steel Curtain Rod 25mm dia/bore (as approved) includingfixing stainless steel Bracket(shaped as approved) not less than 80mm longto wall with Screws/ securedwith stainless steel side doom(as approved) fitted/tightened on Curtain Rod at both ends with screw including taking down old curtain rod of any description, complete all as specified and as directed. |
| 37 | M&L for exterior grade, coloured glossyfinish rubber pressed, cement concrete designer chequered tiles of size 40cm x 40cm x 25mm thick( as approvedby GE) set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc laid overincluding 15 mm thick cement screed bed in CM 1:6 . complete all as specifed and as directed |
| 38 | M&L for exterior grade, coloured glossyfinish ceramic designer endura tiles of size 30cm x 30cm x 8-10mm thick(as approved by GE) set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc laid over andincluding 15 mm thickscreed bed in cm 1:6 complete all as specifed and as directed |
| 39 | M&L for PCC (1:2:4) type B1, (using 20mm graded crushed stone aggregate) as in cement concrete in roof kerbs or mud stops, rounded or chamfered on edges. |
| 40 | M&L for preparation of newsurface of any description and applying two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface over 10cm width or girth complete all as specifed. |
| 41 | M&L preparing old Treated/Painted Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 42 | M & L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm including cleaning surface complete as all specified and as directed |
| 43 | M&L for water proofingtreatment with polymeric water proofing membrane as under :-Supply and layingfive layer prefabricated Atactic polypropylene Polymer (APP) modified membrane of 3mm thick membrane (Weight not less than 3 Kg/Sqm) reinforced with 160gsm polyster non woven fabric with two coat of water proofing paint with alumnium finish on top including overlapping as per manufacturers instruction.Note : APP membrane shall be laid on primed surface by Torch application method after allowing 24 hrs for Primer to dry. On Accesible roof where Brick tile is laid APP membrane shall not be painted. |
| 44 | M & L for Hydraulically pressed PCCtile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 15mm thick in CM 1:6 mixed with water proofing compound and jointed pointed in CM 1:3 mixed with 5% crude oil by weight of cement. |
| 45 | Designing providing and fixing 3mm thick Aluminium Composite Panel Cladding over RCC/Brick surfaces either segmental/straight in plan wherever specified with extruded aluminium U sections, angle, cleats, weather silicon sealants, backer rods of required size stainless steel screws, rivets, brackets, drilling and fixing the cladding to either masonry or reinforced cement concrete including repairing of wall with plaster CM 1:4where required to fix aluminium setion as the case may be manufacturer\"s specifications, complete the work in all respect including all necessary accessories. At all soffits aluminium cladding shall be bend 90 degree and joints at corner or edges will not be acceptable. On horizontal surface, the size of sheet should be maximum available of size complete all as per manufacturer\"s specifications and as directed. |
| 46 | Taking down cement plaster of any description on brickwalls, etc including raking out joints, hacking for key scrubbing down with water etc. |
| 47 | M&L Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed of size 6mm with Coarse Sand and Cement in the ratio 1:1:1 shall be applied and finish Even, complete all as specified and as directed. |
| 48 | M&L preparing newly Rough Cast plastered surfaces of Walls and applying Two Coats of acrylic Weather Coat Exterior Paintwith approved Tint over a coat of Primer (as per Manufacturer\"s instructions), complete all as specified and as directed. |
| 49 | M&L for three coats of white wash on New plaster surface of ceiling including prepration of surface. |
| 50 | S&F GI Powder coated GI Snap Grid Frame Work of size 605x605mm as in False Ceiling with supported hanging of Mild Steel Rod of\"J\" Bolt, complete all as specified and as directed. |
| 51 | M&L for 12 mm thick perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size,fixed with nails or with staple in ceiling/ timber frame complete all as specified. |
| 52 | S&F Aluminium Barrel Tower Bolt 150mm long (weight not less than 210 Gram), extruded section, complete all as specified and as directed |
| 53 | S&F Aluminium alloy, anodized, Sliding Door Bolt 200mm long with Hasp Staple (Bolt type) and Fixing Clips of Sheet cast or extruded section and fixing Bolts and Sliding Bolts of extruded section and fixing, complete all as specified and as directed. |
| 54 | S&F Stainless Steel Butt Hinge of size 100mm (weight not less than 80 Gram), complete all as specified and as directed. |
| 55 | S&F Extruded Aluminium alloy Handle 150mm long (weight not less than 120 Gram), Fabricated type, anodised, complete all as specified and as directed. |
| 56 | S&F Sheet Glass 5.0mmthick, Tinted (as approved by GE) fixing to Aluminium door /Window including replacement of Rubber Packing and refixing Aluminium Beading, complete all as specified and as directed.NOTE : Cost of Rubber Packing shall deem to be include in the Quoted Unit Rate. |
| 57 | S&F1mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and stapleand one shop coat of primer;erected in position as indicated, complete: but gear operated type withbevelgear boxand crank handle etc complete all as specified and directed by Engineer-In-Charge |
| 58 | Surface Excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/lose soil etc complete all as specified and directed by Engineer-In-Charge |
| 59 | M&L for 100 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregates) as in sub base of path/roadsetc complete all as specified and directed by Engineer-In-Charge |
| 60 | M&L for 20 mm thick sand cushioning including watering and consolidations etc complete all as specified and directed. |
| 61 | M&L for Providing, precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate)in cover slabs and similar articles with plain faces etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match complete all as speciied and as directed. |
| 62 | M&L for providing cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregates) as in foundation filling and mass concrete ,lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , on roofs , not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, etc including necessary formwork complete all as specified and directed by Engineer-in-Charge. |
| 63 | Excavation in post holes (or similar holes) in hard /dense soil each n exe 0.5 cu.m, gettting out, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exeeding 25cm, watering, and removing surplus soil to a distance n exe 50 m and making good surface complete all as specified and as directed. |
| 64 | S&F rolled sections, MS Angles, MS tubular Structures, MS Channels, Tee, etc. (Fe 410-W Gde-E-250 quality-A) as in main and cross beams, hip and jack rafters, purlins , posts,trusses (framed or unframed) structures where connected to common rafter and running rails and guides for sliding doors, fixed with angles clleats or other connecting plates all as specified. |
| 65 | S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel 0.50 mm thick of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer-in Charge |
| 66 | M&L for point wiring complete with copper conductor PVC insulated FRLS Cable 1100 volts grade in PVC conduitecomplete all as specified and as |
| 67 | (a) One light point /Bell point/Fan point controlled by one switch with cable 1.5 Sqmm size all as specified and directed |
| 68 | (b) One light pointpoint controlled by two 2-way switchs with cable 1.5 Sqmm size all as specified and directed |
| 69 | (c) One 3 pin socket outlet 5 Amps on Same board including singal core multi-stranded copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth duly all as specified |
| 70 | (d) One 5 pin socket outlet 5/6 Amps on independent board including singal core multi-stranded copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth doily all as specified |
| 71 | (e) Ditto- but with cable 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm multi-stranded copper unsheathed complete all as specified and as directed. |
| 72 | (f) Ditto- but with cable 4 Sqmm and earth continuity conductor of 4 Sqmm Multi-stranded copper unsheathed complete all as specified and as directed. |
| 73 | Supply and fixswitch piano type one way 6 Amps flush type ,240 voltAC all as specified and directed. |
| 74 | Supply and fixswitch piano type one way 16 Amps flush type ,240 voltAC all as specified and directed. |
| 75 | Supply and fix socket2 in 1, 3/5 pin, 6 and 16 Ampsflush type ,240voltAC all as specified and directed. |
| 76 | Supply and fixsocket outlet 2 in 1 ,3 pin 6 Amps all as specified and directed. |
| 77 | Supply and fixswitch piano type two way 6 Amps flush type ,240voltAC all as specified and directed. |
| 78 | S & Fixstepped type electronic fan regulatorflush type. |
| 79 | M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers includingPCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified and directed. |
| 80 | Supply and fix ceiling rose surface bakelite with three terminals complete all as specified and directed. |
| 81 | Supply & Fix Double poleSheet matel enclosure box with a two pin and earth plug and socket complete with singal pole MCB 20 Amps all as specified and directed. |
| 82 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 83 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 84 | Supply and install hi wall split Type Airconditioner with indoor & outdoor unit complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser,PM 2.5 Filter for better indoor air quality with 5 star rating of capacity 1.5 TR with precharged CFC free refrigerant all as specified and directed by Engr-in-Charge. Hitachi Cat part no. 1.5 ton, 5 Star Inverter ( Copper RSOG518HDEA Gold) Make-:1.Hitachi or equivalent in 2.Voltas. 3. Blue star |
| 85 | S & F sheet metal enclosures for double door distribution boardfactory made duly painted 8 way SPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified and directed. |
| 86 | Supply and fixingminiature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP240V, 10 KA \"B\" curve , in the MCB DB Complete with connection testing and commissioning all as specified and directed.. |
| 87 | Supply and fixingminiature circuit breaker (MCB) of SPN and current carrying capacity 40 Amps 240V, 10 KA \"B\" curve , in the MCB DB Complete with connection testing and commissioningand including taking down complet all as specified and directed. |
| 88 | Supply and fixing MCCB 100 Amps, TPN, Breaking capacity 16 KA, 415 V \"B\" curve adjustable type all as specified of capacity |
| 89 | Supply & installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V accuracy of 2.5 % , 4-6 sec initial delay and capacity of size 4 KVA complete all as specified and directed. Make-: vguard/ bluebird/Sinetrac |
| 90 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mmsweep with, blades, and frame and louvers |
| 91 | S&F submain wiring withsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core and one runs of 4 Sqmm PVC insulated copper conductor for earth continuity wire between Sheet matel enclosure box to Sub main DB complete all as specified and as directed.Note :- 1.Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note 2: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 92 | Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 93 | Returning filling in including spreading, leveling, watering and well ramming in layersexc 25 cm thick complete all as specified and as directed. |
| 94 | Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed. |
| 95 | Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted.Note : Punned down thickness shall be measured and paid . |
| 96 | M&L for sub class ‘B’ bricks old sizelaid flat dry in trenches over cable, across the direction of cable complete all as specified & directed . |
| 97 | M&L for drilling hole underhard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying ofpipe for protection of cable etc by means of mannual bookle and without disturbing the top surfaceand making good the disturbed surface if any complete as sepecifiedand directed by Engr-in-Charge. |
| 98 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 4 core |