Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. |
| 2 | 75mm thick Plain cement concrete M-10 nominal mix, C-2, using 40mm graded mechanically crushed stone aggregate as in sub base flooring, complete all as specified and directed. |
| 3 | Plain cement concrete M-15, nominal mix, type B-0, using 12.5mm graded mechanically crushed stone aggregate as inflooring, 25mm thick, surface finished even and rough to receive top finish or chamfering of RCC chajja with proper slope to drain off storm water, complete all as specified and directed. |
| 4 | Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. |
| 5 | Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. |
| 6 | Non skid, Premium class Igrade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, as in skirting, dado etc . set and jointed in neat cement slurry and includingincluding 10mm thick rendering in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed. including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed. |
| 7 | Granite 20mm thick (table rubbed and polished) in steps, jambs, pollars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15mm thick screed bed in cement mortar (1:6), including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed by Engr-In-Charge. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. |
| 9 | Glazed coloured tiles of size 300mm/450mmx350mmx7mm thick as in vertical surfaces such as jointed in neat cement slurry and pointed with coloured cement to match and including 10mm thick plastering in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 10 | Dismantling and breaking up PVC drain pipes 75/110mm dia, fixed to walls, laid in floors or in trenches and removal of demolished materials from the site, complete all as specified and directed. |
| 11 | PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75mm in cement concrete 1:2:4 type B-1, fixed, complete all as specified and directed. |
| 12 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 75mm, complete all as specified and directed. |
| 13 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 110mm, complete all as specified and directed. |
| 14 | PVC (SWR) junction single, (Single T) equal or unequal, 75mm bore, provided with oval access door, fixed in repair, complete all as specified and directed. |
| 15 | PVC (SWR) junction single, (Single T) equal or unequal, 110mm bore, provided with oval access door, fixed in repair, complete all as specified and directed. |
| 16 | PVC (SWR) bends any radius, 110mm bore jointed with solvent cement (fitted with or without oval access door), fixed in repair, complete all as specified and directed. |
| 17 | PVC (SWR) bends any radius, 75mm bore jointed with solvent cement (fitted with or without oval access door), fixed in repair, complete all as specified and directed. |
| 18 | PVC (SWR) vent cowl 110mm bore fixed in repair, complete all as specified and directed |
| 19 | Bib taps, fancy type 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, chromium plated screwed for iron pipe or for brass ferrule and fixed in repairs, complete all as specified and directed. |
| 20 | Chromium plated centre hole Mixer for Wash hand basin for mixing hot or cold water with 450mm braided connection pipe (without pop-up) screwed for iron pipe, complete all as specified and directed.Make:Cat. No.: F12002461 of \"CERA\" or equivalent in makes specified in Appendix \"C\". |
| 21 | Wash hand basins, Vitreous China, counter Table top (Oval shape) coloured of size 560 x 400 x205mm, fixed on granite counter by making suitable holes, excluding pillar tap but including brackets, 450mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including, 32mm dia waste fittings brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, completeall as specified. Make Cat No S2030103 of \"Cera\" or equivalent in makes specified in appendix F |
| 22 | Vitreous China wash down water closet (pedestal pattern) with flushing cistern (single piece), coloured of size 800 mm X 375 mm X 650 mm of make \"Jaquar\", 700 x370 x745mm of make \"Prayag\", 650 x360x750mm of make \"Hindware\" / 720 x 370 x 760mm of make \"Cera\" including traps, trap distance 180 mm connection to drain or outgoing pipe, , flushing pipe, anti-syphonage pipe complete including fittings, PVC coloured seat cover andCP jet including PVC connection, fixedcomplete including demolition of old unservicable WC and provision of PCC M-15, type B-I, using 20mm graded crushed stone aggregate all as specified. Make: Cat Part No. ARS-WHT-39751P and ARS-WHT-39201 of Jaquar or Cat part ARTISAN 4390 of Prayag, Cat part 20122 (S-22)/ Cat 20127 (P-18) of Hindware or Cat No A1014112 of Cera or equivalent makes mentioned in Appx \"C\" |
| 23 | Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, snow white, with CI‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate, including making connections to trap and to flush pipe including CP jet etc complete all as specified, anti-syphonage pipe, fixed, complete all as specified and directed. |
| 24 | Supply and fixed in repair PVC valveless, syphonic action type flushing cistern 10 litres capacity low level with inlet, ball valve, float and handlewith brackets including 32mm dia PVC long bend flush pipe 90cm long and 15mm dia PVC connection 600mm with CP brass coupling nuts and PVC washers at both ends, fixed, complete all as specified and directed. |
| 25 | 600mmx450mm bevelled edge looking mirror of selected quality with 6mm thick polished glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers fixed in repair, complete all as specified and directed. |
| 26 | S&F vitreous China urinals, full stall type of approved size white colour complete including waste coupling of PTMT 32mm bore, urinal spraeder for 15mm bore pipe, providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern for gravity flow with brackets, flush pipe, grating and Union for discharge pipe includingwaste pipe fixed iin repair all as specified and directed. |
| 27 | Soap dish, chromium plated, fixed to plugs with chromium plated, brass screws and fixed in repair, complete all as specified and directed. |
| 28 | Sheet glass shelf assembly 55cm long consisting of 5.50mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, selected quality as approved by GE, fixed in repair, complete all as specified and directed. |
| 29 | Angle valve/stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed in repairs, complete all as specified and directed. Make: Cat No. F2002201 of \"CERA\" or equivalent |
| 30 | S&F in repair towel rail 450 mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 170 gms), complete all as specified. |
| 31 | Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for, including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. |
| 32 | Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, including formwork, complete all as specified and directed. |
| 33 | TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 34 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping)etc. for fair finished flat surfaces of concrete, complete all as specified and directed. |
| 35 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each and removing from site, complete all as specified and directed. |
| 36 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but not exc. 4 Sqm each and removing from site, complete all as specified and directed. |
| 37 | Taking up or down 15mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. |
| 38 | Mild steel galvanized iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as tank nipples, sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed. |
| 39 | Mild steel galvanized iron water tubing 32mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as tank nipples, sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed. |
| 40 | S&F 32mm Tank Nipple suitable for HDPE water tank (Minimum weight 15 mm-38 gms/20 mm-45 gms/25 mm-65 gms), complete all as specified and as directed. |
| 41 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasketetc.Aluminium sections shall be smooth, rust free, straight, mitredand jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainlesssteel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 42 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 43 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 44 | Sheet glass 3mm thick ordinary quality and glazingwith oil putty/aluminium beads in squares, not exc. 0.5 Sqm in each pane, complete all as specified and directed. |
| 45 | Figured glass, pin head type3mm thick and glazing with oil putty in squares n exc 0.5 Sqm in each pane, complete all as specified and directed. |
| 46 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks of glavanised wire staple fixed with stainless steel wire staples, fixed, complete all as specified and directed. |
| 47 | M&L WPC (Wood Polymer Composit) Double Prelam Door Frame (Chowkhat) of Size 120mm x 50mm with a wall thickness of 5mm(+/- 0.25), made out of extruded 5mm(=0.25) mm thick PVC Sheet of Density 600kg/cbm manufactured y an ISO 9001-2015 certified company and by joining 3 Nos heat moulded PVC Sections. The high section of size 35 x35 mm shall be maid from plain colour PVC sheet of 5mm(=/- 0.25 mm) thickness. The inside section will be covered with 5mm thick PVC sheet\"C\" shape covering section of size 120mm x 50mm. At centretop position 5mm(+0.25mm) thick 50 x50 x50 mm pattam section should be pasted with solvent cemen adhesive to make double pattam of frame. The frame shall be mitre cut at two corners & joined with 4 nos of 150mm long \"L\" brackets of 19 x 19 mm MS square, Tube or fusion heat welding process. The two vertical door frames are to be reinforced with 25 x 25 mm MS square Tube of 19 gauge throughout the frame. The Door Frame shall be fixed to the wall using 8/100mm fischer screws. A minimum of 4 nos of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member etc. complete as per manufacture\"s specification & direction of engineer-in charge. |
| 48 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of solid core single Leaf Flush Door of 25mm thickness, lipped with 15mm (5mm x 3) thick x 30 mm width on one stiles and top rails & 10mm (5mm x 2) thick x 30 mm width on the other stiles & bottom rails. The inner panel Laminated with 2mm thick termite proof, water proof & fire resistant moulded PVC sheet with 2,4,6 raised panel design in different plain &/or prelam colors on one side after routing the mouldd design on flush door & 2mm plain and/or prelam PVC sheet on other side using rubber based adhesive on flush door & solvent cement adhesive on the lipping etc. complete as per direction of Engineer-in-charge, manufacture\"s specification and drawing. |
| 49 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars, including removal of debris to a distance exc 1.5 km but n.exc 2 Km, complete all as specified and directed. |
| 50 | Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 51 | Brick work with old sizefly ash bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 52 | Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. |
| 53 | Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) on internal fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 54 | Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers on fair faces of brick or stone walls finished even and smooth without using extra cement, mixed with and including Water proofing compound, complete all as specified and directed. |
| 55 | Rendering cement plaster 10mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) on ceiling surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 56 | Material and Labour for waterproofing of exterior walls, including complete removal of existing plaster including raking out joints and applying two coats of acrylic polymer modified high performance coating (Smartcare Ultra Block 2k). The treatment shall be done from ground level and providing 15mm thick cement plaster in CM 1:4 finished even and smooth all as directed. Make: \"ASIAN PAINTS/BERGER/NEROLAC\" |
| 57 | Preparation of new plastered or unplastered surfaces of wall to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. |
| 58 | Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over & including 2mm thick wall care putty, complete all as specified and directed. |
| 59 | Preparation of new plastered surfaces of ceiling with 2mm thick wall care putty and applying one coat of oil bound distemper, complete all as specified and directed. |
| 60 | Excavation over areas, n exc 1.5 m deep and getting outgetting out in any type of soil,allas specified. |
| 61 | Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point, complete all as specified and directed. |
| 62 | Hardcore of broken stone or boulders of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 63 | 75mm thick Plain cement concrete 1:4:8 nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in sub base flooring, complete all as specified and directed. |
| 64 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 65 | Plain cement concrete M-15, nominal mix, B-0 using 12.5mm graded mechanically crushed stone aggregate as in lintels upto 1.50 metre clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as specified and directed.Note :- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately. |
| 66 | Excavating in post holes (or similar holes) each n exc 0.50 cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, complete all as specified and directed. |
| 67 | Plain cement concrete M-7.5, nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed. |
| 68 | Preparetion of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. |
| 69 | Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed. |
| 70 | All as per srl item 69 here in before but for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. complete all as specified and directed. |
| 71 | Welded steel wire fabric supplied and fixed complete to steel members (Weight not Exceeding 4 Kg/Sqm), Complete all as specified. |
| 72 | Rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240s, steel work complete, all as specified. |
| 73 | Rolled mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. conforming to grade Fe.410-W Gde E-250, quality A, steel work, complete all as specified and directed. |
| 74 | Mild Steel framed work as Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete, conforming to Fe 290 Gde E-165, all as specified. |
| 75 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 76 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 77 | Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete and refixing in same opening all as specified and directed. |
| 78 | Pressed steel frames of size 125x60mm for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 25x3mm flat iron 230mm long hold fast etc, complete all as specified and directed. |
| 79 | Plain cement concrete M-10, nominal mix, C-0, using 12.50mm graded mechanically crushed stone aggregate as in filling in pressed steel frame of any size, complete all as specified and directed. |
| 80 | 35mm thick flush shutters, solid core construction with block board core and plywood face panels commercial type on both sides, complete all as specified and directed by Engr-In-Charge. |
| 81 | Factory made 2nd class hard wood (Sal) glazed and Skelton door shutters 35mm thick open rebated and prepared to receive glass gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass or gauge etc., size of members of shutter as specified in clause 8.24 (a) of part-I, fitted to chowkats, complete all as specified and directed. |
| 82 | Plain cement concrete M-10, nominal mix, C-0, using 12.50mm graded mechanically crushed stone aggregate as in filling in blocks for fixing hold fast of any size, complete all as specified and directed. |
| 83 | Applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surfaces of any description, exc. 10cm width or girth including preparation of surfaces, complete all as specified and directed. |
| 84 | Butt hinges (ISI marked), medium weight, cold rolled, mild steel 75mm long, complete all as specified and directed. |
| 85 | Extruded aluminium alloy handles (ISI marked, fabricated type, anodised, of size 150mm, complete all as specified and directed. |
| 86 | Aluminium anodised, (ISI marked), barrel tower bolts of extruded section, length of bolt 100mm, fixed, complete all as specified and directed. |
| 87 | Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 250mm with lipping frame to match, complete all as specified and directed. |
| 88 | Ordinary rat tail rod pattern springs 300mm, including roller and roller plate complete all as specified and directed. |
| 89 | S&F for Steel locking bolts with mild steel electrogalvanised plate and bright bolt not less than 10mm dia 100mm size all as specified. |
| 90 | Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm, fixed in repair, complete all as specified and directed. |
| 91 | Taking down aluminium door shutter n. exc 2 Sqm each, taking out servicable glass panes, hydraulic door clocer, but hinges,double action hydraulically regulated floor spring and other fittings, if required carefull and refixing in the same opening after repairs of unservicable or loosened joints/cleats of top rail/bottom rails/lock rails and styles etc and fixing old servacale glass, any thickness with rubber packing and aluminium beadings, fixing of old servicable hydraulic door closer, double action door spring duly oiling/greasing and fixing all servicable fitting complete all as directed by Engr-in-Charge.NOTE;- Unservicable door closer, double action floor spring, glass panes and other fittings etc shall be replaced and paid under separate items of schedule. |
| 92 | Preparation of old painted wooden surfaces of any descriptionover 10 cms width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed |
| 93 | Taking down cement plaster/decayed concrete from RCC roof projections/upward parapet walls/down facia/soffits and fins of RCC chajjas/beams/columns/balconies etc. Supply and fixing by means of nailing wire netting of galvanised wire 1.40mm dia and mesh size 20mm and brushing neat cement slury with 3.00 Kg of cement/sqm and M&L for 20mm thick cement rendering in two layers of 10mm each (top/final layer shall be rendered after final setting of under layer) in CM 1:3 on concrete surfaces including scaffolding at a height upto 7.00 mtrs ect, complete all as specified and directed. |
| 94 | Disconnecting existing tanks of capacity 500 litres to 1000 ltrs litres, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position including repairing cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. and hoisting if requiredall as specified. |
| 95 | Rotational moulded polyethylene water storage tank 1000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including PVC float ball valve 20mm dia epoxy coated aluminium rod with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, complete including taking down old tank and removng to store all as specified and directed. |
| 96 | Taking down existing water proofing treatment (including cement plaster, tarfelt and cleaning with wire brushes roughening the surface and hacking out dirt where directed and diposal of rubbish not exc 500 mtr distance from starting point) and applying following treatment:(i) 15mm thick plaster in cement mortar 1:4 in order to maintain proper slope and base over existing roof surface for laying of APP based polymeric membrane, mixed with water proofing compound@ 3% by weight of cementfinished the surface even and smooth without using extra cement all as specified and directed.(ii) One coat of bitumen primer @ 0.40Kg per Sqm conforming to IS-3884(iii) One coat ofbitumen bonding material using blown type bitumen 85/25 conforming to IS: 702 at the rate of 1.2 kg per sqm including cleaning surfaces(iv) APP based polymeric membrane centre core of 100 micron HMHDPE outer film 20 micron weighing 2.25kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric laid on primed surface by forced application dipped into APP modified mix and sealing all the overlap 75mm on lengthside and 100mm on width side of membranes by torching as per manufecturer\"s instructions. |
| 97 | Preparation of APP membrane surface and applying one coat of Aluminium paint on prepared membrane surface all as specified and directed. |
| 98 | Taking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including switches, sockets, holders, (batten or pendent type), ceiling rose, switch board, bell/buzzer, bell push, and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes, complete all as specified and directed. |
| 99 | Taking down submain wiring any type and any size and making good disturbed surface by using cement mortar, white cement, putty etc. and match with existing surfaces of walls, floors etc., complete all as specified and as directed. |
| 100 | Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surfaces, complete all as specified and directed. |
| 101 | M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and includingconcealed PVC conduit(ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable sizeincluding concealedMS pressed steel (Modular sunken box) terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and Modular cover plate as top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point controlled by one switch, complete all as specified and directed. Note : i)Wiring Colour code i.e. Red/Yellow/Bluefor Phase, Black for neutral and Green for earth shall be maintained.ii) Rate of cutting chases, cement plaster, white wash and making surface good as existing surface included in quoted rate.iii) Point wiring is considered for Modular Switches and sockets. Rate of Metallic Sunken box and modular sheet cover plate and other connected accessories required for modular point wiring included in quoted rate.iv) Switch and sockets will be paid seperately under relevant item. |
| 102 | All as per item No 101 above but for ceiling fan/ exhaust fan controlled by one 6A switch, one way complete all as specified as directed. |
| 103 | All as per serial item No \"101\" above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. |
| 104 | All as per serial item No \"101\" above, but for one 3 pin 5 Amps socket outlet on the same board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. |
| 105 | All as per item No 101 above but for bell/buzzer point controlled by one 6A switch, one way complete all as specified as directed. |
| 106 | All as per serial item No \"101\" above, but for 5 pin 15 amps socket out let on independentwith 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed. |
| 107 | All as per serial item No \"101\" above, but for 5 pin 15 amps socket out let on independentwith 4.00 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 4.00 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed. |
| 108 | S & F for modular switch 6A one way, single module, complete all as specified and directed. |
| 109 | S & F for modular switch 16A one way, single module, complete all as specified and directed. |
| 110 | S & F for modular bell push 6A, single module, complete all as specified and directed. |
| 111 | S & F for modular socket for 6A 2/3 pin combined, 2 module, complete all as specified and directed. |
| 112 | S & F for modular socket for 6A/16A, 5 pin combined, 2 module, complete all as specified and directed. |
| 113 | M & L for ceiling rose 65 x 50mm three terminals, fixed, complete all as specified and directed. |
| 114 | Supply and fixing modular cover plate with frame, 3 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge. |
| 115 | Supply and fixing modular cover plate with frame, 4 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge. |
| 116 | Supply and fixing modular cover plate with frame, 6 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge. |
| 117 | Supply and fixing modular cover plate with frame, 8 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge. |
| 118 | Supply and fixing modular cover plate with frame, 10 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge, |
| 119 | S&F in repair Bell electronic, Ding Dong AC 230 Volts, single pole, complete all as specified and directed. |
| 120 | Taking down ceiling fan/exhaust fan of 1200/300/250 mm sweep, any size/make from existing position of any height by disconnecting electrical connections and transporting to store for Inspection in presence of Engr-in-charge/JE (or rep of department) after dismentling spares parts complete all as required at site and directed by Engr - in - Charge. |
| 121 | Supply and fixing high speed stepped type electronic fan regulator 120W, 230 Volts, complete all as specified and directed. |
| 122 | Supply and hanging ceiling fan including fan regulator step flush type speed controllorwith complete fixing arrengement of size 1200 mm sweep blade minimum air delivery 210 CFM with service value 6.00 BEE, five star rated (BLDC) including provision of copper multi stranded PVC insulated 1100 volts grade three core flexible cable for main connection with existing ceiling rose at point wiring complete all as specified and directed by Engr-in-Charge. |
| 123 | Supply and fixing for AC exhaust fans, Steel body, single phase, 230 volts, 250 mm sweep including grouting the ragged bolts in wall, fixing the frame on the exhaust side and connecting up with PVC insulated three core 1.50 sqmm copper cablefrom ceiling rose to exhaust fan, complete all as specified and diercted. |
| 124 | Supply and fixing high speed wall mounted fan best-in-class performance of 2100 RPM of size 400 mm sweep blade minimum air delivery 105 CFM including grouting the ragged bolts in wall and connecting up with PVC insulated three core 1.50 sqmm copper cablefrom ceiling rose to exhaust fan, complete all as specified and diercted. |
| 125 | Taking down water storage heater(Geyser) of 25/35/50 liters capacity from electric socket and disconnecting PVC connection, water supply, screwed down and transporting to store for Inspection in presence of Engr-in-charge/JE (or rep of department) after dismentling spares parts complete all as required at site and directed by Engr - in - Charge. |
| 126 | Supply and installing of the electric water storage heater (Geyser) of ABS body type of 25 litre capacity with rated power 2 KW, BEE, 5 star rated, vertical type, thermally insulated Mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostate, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm dia bore GI hexagonal adopters/Nuts on both side of inlet (cold water supply) and outlet (hot water supply) and including provision of wall mounting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation, complete all as specified and as directed by Engr-In-Charge. |
| 127 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as required at site, complete all as specified and directed by Engr - in - Charge. |
| 128 | S&F LED tube light fitting inverter type 1x 20 W, 220V, decorative type with driver, ultra slim square profile LED lighting fixture, environment friendly, energy efficient ready to use completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed. |
| 129 | Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt, 6000 K, 220 volts, AC decorative type with extruded polycarbonate having efficiency 120 lumens /watt with driver holder including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 130 | Supply and fixing of LED security light fitting 45 Watt, 230V, AC, outdoor type with high pressure die cast aluminium housing with street optic lens and glass diffuser for uniform light distribution and inbuilt surage protection device (SPD) and heat resistant complete with driver, street light bracket made out of GI pipe 32/40mm dia medium grade GI pipe minimum 1.50m long including fixing with 02 Nos MS clamps made out of flat iron of size 30mmx5mm with nuts, bolts and washers including painting with impact and corrison resistant including thermal management in multiple optics complete with IP 65/66 protection 6500K, complete all as specified and directed by Engr-In-Charge. |
| 131 | S & F for MCB SP 6 to 40 amps 240 Volt,10 KA, \"B\" series, complete all as specified and diercted. |
| 132 | S & F for MCB SPN 40 amps 240 Volt, 10 KA, \"B\" series, complete all as specified and diercted. |
| 133 | S & F MCCB four pole 125 amps adjustable type, 415 volts, 50 Hz, breaking capacity, 16 KA including making all connections using bottle /pin copper thimbles, complete all as specified and diercted. |
| 134 | Sheet metal enclosures factory made flush fixed for DBs when MCBs to be used, single pole and neutral (double Door powder coated), 12 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed. |
| 135 | S & F of sheet metal enclosures distribution boards, double door, VTPN, 415 volts 4 ways, as per IEC 61439-3, degree of protection IP-43 (one incoming three phase & twelve out goings single phase) for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed including and comprising of the following:- (a) MCCB FOUR POLE 160 amps, AC,415 VOLTS25 KA=01 No (for incoming).(b) MCB SP 06- 40 amps = 12 Nos (for outgoings) complete with 250 amps fully insulated copper bus bar for each phase and neutral link, prefitted masking sheet fixed flush in wall including chases wall for fixing DB, complete all as specified and diercted.Note :- (i) TheDB shall be VTPN seriesof Make : Schneider or techno Equivalent inmake of L&T/ ABB/legrand(ii) Connection of the MCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble properly crimped(iii)All the vacant holes of the DB shall be provided with blank plates of appropriate size.(iv) Double continuous earth wire shall be provided for each three phase DB from earthing mains duly.(v) Cutting chasing shall be part of job at no extra cost |
| 136 | M & L for submain wiring in and including PVC conduit 1.8 mm thick, 20 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 6 sqmm (FRLS) and one run of PVC insulated, unsheathed multistranded copper conductor 6 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM).Note: (a) Insulation test of point wiring to be carried out on completion of work.(b) Proper colour coding is to be maintained. (Ph-Red, N-Black,Earth- Green)(c) Two runs of single core cable with one run of earth cable and suitable size of conduit shall be measured as one RM.(d) Cutting chases for sub main wiring concealed PVC rigid conduit shall be deemed to be included in the quoted rate of item. |
| 137 | Supply and Fixing sheet metal enclosure with socket plugtop with MCB of a two pin and earth plug and a socket complete with one double pole MCB of 20 Amps rated, complete all as specified and directed. |
| 138 | S & F in replacement 25mm Rigid non-metallic PVC conduit heavy duty for telephone line exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed. |
| 139 | PVC Junction boxes (1 to 4 way) for telephone line fixed in repair, complete all as specified and directed. |
| 140 | Telephone socket fitted in robust designed assembly, plates smug fit on the wall with assembly plates with suitable modules, whitein colour dust free glossy finish complete all as specified and directed. |
| 141 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.50m below ground level, connecting to galvanised iron wire 4.00mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.NOTE :- Item of earthing includes the cost of 7.5 m long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work. |
| 142 | Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 25 sqmm x 4 core, 1100 Volts grade, complete all as specified and diercted. |
| 143 | Excavation in trenches n exc 1.50 metre wide & n exc 1.50 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n exc 1.50 metre in depth and getting out in any type of soil, complete all as specified and directed. |
| 144 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick each layer of soil, complete all as specified and directed. |
| 145 | Sand cushioning to under ground cables, 8cm thick layer before laying and testing the cable and 15cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I, complete all as specified and directed by Engr-in-Charge. |
| 146 | Supply and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and directed by Engr-In-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail