| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(Group-B) |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wiresizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 4 | Supplying and fixing 1 or 2 Module (75mmX75mm) size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 5 | Supplying and fixing 6 pin 15/16 amp socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (2 +6 way, Double door) |
| 7 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Single pole) |
| 8 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Single pole and neutral) |
| 9 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 10 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 11 | Supplying, layingand fixing of following size HDPE pipe ISI marked conforming to IS 4984,in the existing trench / pole collar for proctection of cable complete as required.A) 40 mm |
| 12 | Supply, installation, testing and commissioning of 20 watt LED tube lightfittings complete with all accessoriesdirectly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. Crompton/Philips/Syska/Havells/HPL) |
| 13 | Providing and fixing of 1400 mm sweep ceiling fan , including wiring the down rods of standard length (upto 30 cm) including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.(Crompton/ Usha/Havells) |
| 14 | Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2x25 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Havells/Polycab/Finolex/KEI cable. |
| 15 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2x25 sqmm in the existing RCC/ HUME/ METAL pipe as required.Havells/Polycab/Finolex/KEI cable |
| 16 | Supplying and fixingof 25 Amp single phase screw type motor starter for air conditioneron the existing MS box withall accessoriesdirectly onwallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |