| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 2 | All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | All kinds of soil. |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 6 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | 1:1.5:3 (1Cement: 1.5 coarsesand (zone-Ill)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 11 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement: |
| 13 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 16 | Foundations,footings,basesof columns,etc.formass concrete |
| 17 | Walls (anythickness)includingattachedpilasters, butteresses, plinth and string courses etc. |
| 18 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 19 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 20 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 21 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 22 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level. |
| 23 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 24 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 25 | White Agaria Marble Stone |
| 26 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 27 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 28 | Second class teak wood |
| 29 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 30 | Kiln seasoned and chemically treated hollock wood 35 mm thick |
| 31 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 32 | Fixed to steel windows by welding |
| 33 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 34 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 35 | 300x16 mm |
| 36 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 37 | 200x10 mm |
| 38 | 100x10 mm |
| 39 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 40 | 125 mm |
| 41 | 75 mm |
| 42 | Providing and fixing to existing door frames. |
| 43 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of requiredcolour andapprovedbrandand manufacture,made with fire - retardant grade unsaturated polyester resin,moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 44 | Providing and fixing factory made door frame (single rebate) made out of solid foam PVC extruded profile of minimum 60 mm width and minimum 30 mm thickness, having homogenous fine cellular structure and integral smooth outer skin. The frame\"s vertical and horizontal members to be mitered cut and joined together with PVC solvent adhesive / cement and both corners strengthened with fully threaded steel screws (of required size) fixed diagonally. The door frame is to be fixed to door jambs using 6 Nos. SS 304 grade minimum 8 mm dia CSK Phillips stainless steel self tapping screws/fasteners with PA6 grade polyamide sleeves both of required size, and gap if any between the door frame and the jamb must be filled with clear silicon, complete as per direction of the Engineer-in-Charge. |
| 45 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanizedmild steel section madeof requiredshape & size asper CPWDSpecification,uPVC extrudedglazingbeads,interlocksandlnlinesashadaptor(where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:-StructuraldesignproofcheckedfromaGovernment Engineering Institute,tobeprovidedbythemanufacturerfor (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 46 | Casement door singlepanel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre). |
| 47 | Providing and fixing 20 mm thick 100 mm wide interlocking uPVC profile sheet of approved quality panelled or panelled and glazed shutters for doors windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured) in uPVC frame shutters. |
| 48 | Providing and glazing uPVC doors windows ventilator shutter and partitions etc with EPDM rubber/neoprene gasket etc. complete as per the architechural drawings and the directions of Engineer-in-Charge. |
| 49 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/Sqm) |
| 50 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 51 | Electric resistance or induction butt welded tubes |
| 52 | Providing and fixing bolts including nuts and washers complete. |
| 53 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufing, polishing andmakingcurvature(wherever required)andfittingthesame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 54 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 55 | 40 mm thick with 20 mm nominal size stone aggregate |
| 56 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 57 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. |
| 58 | 0.80 mm thick with zinc coating not less than 275 gm/m2 |
| 59 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 60 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 61 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cuttingholes and making good the walls etc. : |
| 62 | 150 mm diameter |
| 63 | Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 64 | 110 mm diameter |
| 65 | Providingand fixing to the inlet mouth of rain water pipePTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. |
| 66 | Providing and fixingPre-Printed galvanune (PPG:) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal Indai Ltd. or equivalent (size, shape andpitch of corrugation as approved by Engineer-in-Charge) 0.50 mm ( + 0.05%) total coated thickness with zinc coating 150 grams per sqm as per IS:277, in 240 mps steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single lenght upto 12 metre or as desired by Engineer-in-Charge. The sheet shall be fixed using self drilling/self tapping screws (Xylan) of size (5.5 x 55 mm ) woith EPDM seal, complete upto any pitch in horozontal/ vertical or currved surfaces, excluding teh cost of purlins, rafters and trusses and including cutting to size and shape wherever required.. |
| 67 | Providing and fixing pre-prinited galvanune )PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal Indai Ltd. or equivelent roofing accessories 0.50 mm (+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 227, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling /self tapping screws complete. |
| 68 | Ridges plain(500-600mm) |
| 69 | 12 mm cement plaster of mix: |
| 70 | 1:4(1 cement: 4 fine sand) |
| 71 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 72 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 73 | Finishing walls with textured exterior paint of required shade: |
| 74 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 75 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 76 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 77 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 78 | Two or more coats on new work |
| 79 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 80 | For thickness of tiles 10 mm to 25 mm |
| 81 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. |
| 82 | With G.I. barbed wire |
| 83 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. |
| 84 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 85 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 86 | W.C. pan with ISI marked white solid plastic seat and lid |
| 87 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 88 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 89 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 90 | Circular shape 450 mm dia |
| 91 | Oval shape 450x350 mm (outer dimensions) |
| 92 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 93 | Providing and fixing toilet paper holder : |
| 94 | C.P. brass |
| 95 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 96 | 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989 |
| 97 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 98 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 99 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 100 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 101 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 102 | 40 mm nominal dia Pipes |
| 103 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 104 | 20 mm nominal dia Pipes |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 106 | 20 mm nominal dia Pipes |
| 107 | Providing and fixing brass bib cock of approved quality : |
| 108 | 15 mm nominal bore |
| 109 | Providing and fixing brass stop cock of approved quality : |
| 110 | 15 mm nominal bore |
| 111 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 112 | 45 cm length 15 mm nominal bore |
| 113 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately. |
| 114 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 115 | 15 mm nominal bore, 107 mm long, weighing not less than 110 gms |
| 116 | Providing and fixing 15 mm nominal bore C.P. brass Bib Cock 2-way Double Handle with Flange makeJaquaer, Prayag, Parryware or equalient. |
| 117 | Providing and fixing Chrome Plated Health Faucet with 1.0/1.2 m Flexiable Tube and hook complete of make Jaguar, Prayag, Parryware or equalient. |
| 118 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 119 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer- in-charge. |
| 120 | Providing hollow block walling upto floor V level 200 mm thick consisting if using hollow block of size 400x200x200 mm of mix 1:3:6 (1 Cement : 3 Coarse Sans: 6 Stone aggregate 20 mm nominal size) having a crusing strength of 3.5 N/Sqm at 28 days as per IS: 2185 (part-1) 1979 laid in cement mortar 1:6 (1 Cement : 6 Coarse Sand) complete. |
| 121 | Providing and fixing tactile (warning) tiles of size 300 × 300 × 9.8 mm, conforming to IS 15622 and IS 13801:1993 (Reaffirmed 2018), of approved make, colour and shade, on floor and wall surfaces, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointed with grey cement slurry @ 3.3 kg/sqm and grouted with white cement mixed with matching pigment, complete as directed by the Engineer-in-Charge |
| 122 | Providing and fixing automatic sanitary dispenser machine suitable for Divyang (persons with disabilities), made of corrosion-resistant ABS or stainless-steel body, with motion sensor–based automatic operation, capable of dispensing sanitary napkins or hygiene products, including all accessories, power connection, mounting brackets, testing and commissioning, complete as directed by the Engineer-in-Charge |
| 123 | Providing disposal bin of 20–25 litre capacity made of stainless steel or heavy-duty plastic with foot-operated lid, suitable for collection and disposal of sanitary and general waste. |
| 124 | Providing and fixing stainless steel cloth hook (Grade 304) wall-mounted type with 2 prongs, fixed with rawl plugs and stainless-steel screws, including drilling, alignment and finishing complete |
| 125 | Providing and fixing alarm pull cord system suitable for Divyang (persons with disabilities), consisting of nylon cord with wall-mounted holder, alarm switch with indicator and buzzer, connected to power supply for emergency use in accessible toilets, including testing and commissioning all complete as per the direction of E-In-C. |
| 126 | Providing and fixing automatic electric hand dryer suitable for wall mounting, made of high-impact ABS or stainless-steel body, having automatic infrared sensor operation, rated for 230 V AC, with air speed > 90 m/s and power consumption up to 2 kW, includingtesting and commissioning complete. |
| 127 | Providing and fixing fully high-density WPC (Wood Plastic Composite) working table with chair suitable for Divyang (persons with disabilities), table of size 1200 mm × 600 mm × 750 mm (L × W × H) and matching WPC chair with ergonomic backrest, both made of solid WPC boards of 18 mm thickness and density not less than 750 kg/m³, with smooth laminated finish, rounded edges, suitable height and knee clearance as per accessibility standards, including all fittings, edge banding, and hardware complete. |
| 128 | Providing and fixing compact drinking-water facility comprising wall-mounted RO water purifier with minimum 5-litre storage capacity and purification rate not less than 10 litres per hour, complete with one stainless-steel drinking tap, 15 mm CPVC inlet and outlet connections, wall-mounting brackets, stop valve, and drain connection to gully trap, including testing and commissioning complete |
| 129 | Providing and fixing uPVC moulded fittings/accessories conforming to IS 14735, including jointing with solvent cement, complete as directed. |
| 130 | Plain bend (Single Socket), required degree: 75mm dia |
| 131 | Plain bend (Single Socket), required degree: 110mm dia |
| 132 | Door bend (Single Socket), required degree: 75mm dia |
| 133 | Door bend (Single Socket), required degree: 110mm dia |
| 134 | Providing and fixing soil, waste & vent uPVC SWR Pipe Type-B conforming to IS 13592 (latest), jointing with PVC solvent cement (conforming to relevant standard), including cutting, chamfering, jointing, testing, and making good the wall/floor/ground, complete as directed: |
| 135 | 75mm dia |
| 136 | 110mm dia |
| 137 | Providing and supplying stainless steel (SS) framed foldable wheelchair (manually operated) for Divyang persons, suitable for use on both ground and first floor, made of high-quality SS tubular frame (minimum 1.2 mm thick), fitted with solid rubber tyres, hand rims, cushioned seat and backrest, detachable footrest, handle grip, and safety brake arrangement, complete with all accessories and as per direction of Engineer-in-Charge. |
| 138 | Providing and fixing self-adhesive reflective vinyl stickers with bilingual lettering (English & Hindi) and international accessibility symbols for Divyang (Persons with Disabilities), on smooth surfaces such as glass, wall or metal, including design, printing, cutting, surface cleaning and pasting complete as per direction of Engineer-in-Charge. |
| 139 | Providing and fixing acrylic (3 mm) or aluminium (1.5 mm) sheet sign boards of size ≈ 450 × 600 mm with reflective vinyl bilingual lettering and accessibility symbols, mounted with brackets or screws, complete as per CPWD Accessibility Guidelines and direction of Engineer-in-Charge |