| 1 | M&L for preparation of old decoreatedexternal wall / internal wall/Ceiling surface of existing treatmentby scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc.or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possibleup to 8 storey bldgcomplete all asspecified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+2 bldg including scaffolding. |
| 2 | M& L for preparing the entire surface withapplying2-3 mm thick birla/ JK wall care putty on walls and ceiling surface finished even and smoothcomplete all as specified and directed. |
| 3 | M& L for preparing the entire surface withapplyingpriming surface with alklai resistance priming paint on walls and ceiling surface finished even and smoothcomplete all as specified and directed. |
| 4 | M&L forexternal wall / Ceilingapplyingtwo coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 3 storey bldg complete all asspecified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+3 bldg including scaffolding |
| 5 | Dismantling false ceiling boards any description and in any position incl frame work. |
| 6 | Providing & fixing false ceilingwith fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG False ceiling tiles atall heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture,design and patterns having moisturecontent less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick(galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.elong, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- |
| 7 | Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame) |
| 8 | Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) |
| 9 | Taking down shutters of any description not exc 2 Sqm each. |
| 10 | M&L for Plain, solid, straight chowkats and frames made of 2nd class hard wood (sal), wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed,making good , and including dismantling complete all as specified and as directed by Engineer-in-Charge. |
| 11 | M&L Mild steel frame work as in door chowkhats with angle iron sizewelded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size,and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges paid sep) all as spd. |
| 12 | S&F 35 mm thick 2nd class hard wood glazed and skelton shutter devided into square with plain, chamferred or rounded sash bar and fitted with cut and mitred beads for securing glass, size of members as per SSS Part - I section 8 clause 8.24 (b). |
| 13 | S&F for 35mm thick both side laminated Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 14 | Servicing and greasing of aluminium door including replacement nut , screws rubber gaskets, pivot, taper clip etc including taking down carefully of door shutter for replacing unserviceable parts/components by new parts /components for smooth functioning of door and refixing the same in existing opening/position, complete,all as specified and directed. |
| 15 | Material and labour for aluminium alloy Powder coated standard 10mmsection and opening of size window grill as per approved sample and as per IS specifications complete all as specified and as directed. |
| 16 | S&Ffor fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steadythe frame and fixing with ancher bolts all as specified and as directed. |
| 17 | S & F 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conformingto IS: 14856, including fixing to frames. |
| 18 | S&F MSbutt hinges medium weight 100 mm size fixed with MS screws. |
| 19 | S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws. |
| 20 | S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws. |
| 21 | S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut. |
| 22 | M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified |
| 23 | M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer |
| 24 | S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed. |
| 25 | Supply and fix in repair figured glass pin head type 4mm thick ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane fixed with oil putty or wooden beads including provision of glazing pins/ spring clips wherever necessary, complete all as specified |
| 26 | Dismantling of tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete. |
| 27 | M&L for Non - skid Ceramic colour tiles 300x300x7 to 8 mm thick (square/ rectangular)in floors etc. set and jointed in neat cement slurry and pointed in white oroloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed. |
| 28 | S&F vitrifiedtiles 600 x600 x 7 to 8 mm thickin floors etc and 15mm thick screed bed 1:6 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified. |
| 29 | S&F Non - skid Ceramic colour tiles 600 x100 x 7 to 8 mm thickin vertical surfaces etc and 10mm thick screed bed 1:4 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified. |
| 30 | M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed. |
| 31 | Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt |
| 32 | Dismantling wrought iron or mild steel work of any description such as guard bars, grills etc. |
| 33 | S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 34 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 35 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above ground level). |
| 36 | M&L PCC 1 : 4 : 8, type D2, using 40mm graded stone aggregates, as in foundation or subbase etc completeall as specified. |
| 37 | M&L chequered endura tiles 30cmx 30cmx 10mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 15mm thick screed in cement mortar 1:6 |
| 38 | Sand filling under floors or in foundations incl. watering and consolidation. |
| 39 | M&L 60mm thick interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M-35 Grade as approved by E-In-C laid in flooring and joints filled/broomed with fine sand. |
| 40 | S & F for steel drapery Rod 18mm diawith brackets in cupboard complete all as approved by Engineer-in-chareg |
| 41 | Schedule of Credit |