Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30 cm deep and getting out in Soft/loose soil,complete all as specified and directed . |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth andgetting out in soft/loose soil,complete all as specified and directed . |
| 3 | M & L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete,complete all as specified and directed . |
| 4 | M&L for RCC,M-30 Design Mix(using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete ,complete all as specified and directed . |
| 5 | Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams; and similar work; vertical or to batter,complete all as specified and directed . |
| 6 | M&L for RCC,M-30 Design Mix (using 20mm graded aggregate) as in Columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 7 | Formwork to Square,rectangular or polygonal rough surface of concreteof sides of pillars, posts, struts, piers, columns and stanchions,complete all as specified and directed . |
| 8 | M&L for RCC,M-30 Design Mix (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span,complete all as specified and directed . |
| 9 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. ,complete all as specified and directed . |
| 10 | M&L for RCC,M-30 Design Mix (using 20mm graded aggregate) as in Slabssupported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified and directed |
| 11 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping),complete all as specified and directed . |
| 12 | M&L forMoorum / Red bajri filling in floors or pavings, laid in layers n.exc15 cm thick spread levelled and rammed incl watering etcall as specified & directed. |
| 13 | Returning, filling in of soft/loose soil including spreading, levelling, watering and well ramming in layers not exc 25 cm.,complete all as specified and directed . |
| 14 | Removing surplus excavated earth (soil) to a distance n. exc 50 m & Depositing where directed at a level n. exc 1.5 m above the starting point. ,complete all as specified and directed . |
| 15 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed . |
| 16 | S&F Mild steel TMT bars 8mm dia and over, cut to length, spacers and binders and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 17 | M & Lbrick work with fly ash bricks, Straight or curved onplan exc 6m mean radius,built in 1:6 in cement mortar ,complete all as specified and directed . |
| 18 | M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface,finishing even and smooth without using extra cement but using waqter proofing compound @3% by wt of cement complete all as specified and directed. |
| 20 | M&L for rendering 5mm thick in CM 1:3 onconcrete surface of ceiling finishing even and smooth without using extra cement ,complete all as specified and directed. |
| 21 | M&L for Preparation of Newly Plastered surfaces of Wall and applying Two coats of White Wash all as specified and directed. |
| 22 | M&L for Preparation of newly plastered surfaces of wall and applying 2 coat of Cement based paint complete all as specified and directed. |
| 23 | M&L two coats of white wash on new plastered ceiling surface including preparation of surfaces ,complete all as specified and directed. |
| 24 | M&L Hard core of gauge n.exc 63 mm, deposited, spread, levelled in layers not exc 15 cm thick, watered and well rammed to a true surface ,complete all as specified and directed. |
| 25 | M & L Cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggreates 100 mm thick as in flooring finished even and fair complete all as specified and directed. |
| 26 | M & L 50 mm thick Cement concrete type B-1, 1:2:4 using 20 mm graded crushed stone aggreates as in flooring finished even and fair complete all as specified and directed. |
| 27 | M&L for Machine cut kota stone slab flooring mirror finished 18-20 mm thick (each slab not less than 0.25 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with15 mm thick screed bed or bedding layer in cement mortar 1:6, including rubbing andpolishing complete all as specified and directed. |
| 28 | M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 18-20 mm thickover cement base renderinglaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with10 mm thick screed bed or bedding layer in cement mortar 1:4,including rubbing andpolishing ,complete all as specified and directed. |
| 29 | M&L 75 mm thickPCC 1:3:6, type C-1 using 20 mm graded stone aggregateas in plinth protection,surfaces finished even and smooth with out using extra cement all as specified.(Note- Joint 12 mm wide to the full depth of pcc shall be provided at every 3 metres and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. cost of this provision shall be deemed to be included in the quated rate for concrete in plinth protection,complete all as specified and directed. |
| 30 | S&F Powder coated Aluminium anodised glazed side hung doorwith following specifications and making good the adjacent surfaces complete all as specified and directed.(a) Cross section of chowkhat/frame 101.60x44.45x2mm thick(b) Cross section of hanging and meeting style 83x44x2mm thick.(c) Top rail of cross section 114x44x2mm thick(d) Bottom rail of cross section 114x44x2mm thick.(e) Lockingrail (middle rail) rail of cross section 100x44x2mm thick.(f) 5.0 mm thick tinted glass of approved make(g) Aluminium handle elsc type -02 Nos per shutter (inside and outside) (h) Aluminium door stopper heavy duty-01 Nos per shutter.(i) Aluminum tower bolt 200 mm long-01 Nos per shutter (inside)(j) Mortice brass Lock- 01 Nos per shutter with key superior quality make as approved by GE |
| 31 | S&F Powder coated Aluminium sliding glazed windows with three track and three shutter slidingwith following specifications and making good the adjacent surfaces complete all as specified and directed.(a) Three way track for sliding shutters of Cross section 91.8 mm x31.8 mm x1.1 mm thick.(b) Sliding shutters frameof Cross section 40 mm x18 mm x1.1 mm thick(c) 5.0 mm thick tinted glass of approved make(d) IDPE rubber gasket for fixing of glass.(e) Locking cleats per shutter-01 Nos.(f) Sliding rollers per shutter-01 Nos.(g) Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.56mm for shutters-01 Nos(h) Fixing screws for frame with wall per window-08 Nos |
| 32 | S&F 7mm thick aluminium grills of god quality surrounded by aluminium \"C\" channel with mesh size 75 X 75mm complete all as specified and directed. |
| 33 | S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. |
| 34 | S&F Pre-painting galvalume aluminum zinc coating GI based corrugatedsteel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 35 | Providing & fixing false ceiling at all heights with Semi perforated 12 mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 1200 x 600 mm of approved texture,design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge. |
| 36 | M&L for applying 3 mm thick wall care Putty in two layers on ceiling surfaces absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper including and applying two coats of Oil bound distemper on ceiling complete complete all as specified and directed. |
| 37 | M&L for preparation of newly steel surfaces of any description over 10 cmin width or girth not otherwise described and applying two coats of synthetic enamelpaint over a coat ofred oxide primer complete all as specified and directed. |
| 38 | Preparation of new steel surface any description, nexc10cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat ofred oxide primer,complete all as specified and directed. |
| 39 | Material and labour for point wiring complete with 1.5 sqmm PVC insulated, Frlsh type, ISI marked, conforming to IS-694/1990 unsheathed, multistandered, single core, copper conductor cable 1100 volts grade lolour code cables drawn through and including PVC Copnduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls/roofs/floors/ceiling etc. flush mounting MS box with top, bottom, side back wall knockout for conduit entry from any direction made out of 1.60 mm thich suitable for fixing of and including white/silver/dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches, sockets, fan regulators, blank plate etc and including above mentioned colour modular plate cover of required modules and including above mentioned colour modular plate cover of required modules and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed (Green colour) single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and for One light point controlled by one switch |
| 40 | All as per item no. 39 but for One fan pont controlled by one switch |
| 41 | All as per item no. 39 but forOne 5 pin 6 amps socket point controlled by one 6 amps switch on independent |
| 42 | All as per item no. 39 but forOne 5 pin 6 amps socket point controlled by one 6 amps switch on same board |
| 43 | All as per item no. 39 but forpoint wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all specified and directed for the One 6 pin 16/6 amps socket outlet point controlled by one 16 amp switch on independent board. |
| 44 | All as per item no. 39 but for One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board. |
| 45 | Supply & fixing modular type switch 10 Amps, single pole, 1way, 1 module, 240v, AC, ISI marked complete all as specfified and directed. |
| 46 | Supply & fixing modular type switch 16 Amps single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed |
| 47 | Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI marked complete all as specified and directed |
| 48 | Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module, 240V, AC ISI marked complete all as specified and directed |
| 49 | Supply & fix angle lamp holder insulated body with back plate for batten fittings complete all asspecified and directed. |
| 50 | S&F ceiling rose, 3 terminal, PVC/polycarbonate body ISI marked complete all asspecified and directed. |
| 51 | S&F LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder incl LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 52 | S&F LED light fittng mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 53 | Taking down old unsv ceiling fan from existing location and supply and fix new ceiling fan with blades, down rods and connected accessories, 230 V, 1200 mm sweep, with squirrel cage induction motor, anti dust painted, dust free, high speed. Star rated complete all as specified and directed. |
| 54 | S&F new exhaust fan, steel/PVC body AC single phase. 230Volts of size 300 mm, sweep with blades and frame with louvers complete all as specified and directed |
| 55 | S&F and sheet metal enclosure, AD/DD 240 volts AC, SPN, DB, 8 way, flush mounting with 200 amps copper busbar, neutral bar, earth bar and MCB incomer, MCB SPN/DP, and MCB SP as outgoing for IP 43 & IP54 DBs protection nd including removing old unsv DBs making good the disturbed surfaces to match with existing surface and colour shade acomplet all as specified and as directed. |
| 56 | S&F MCB SP 6 to 32 Amps 10 KA, \"C\" series, AC, 240Volts, 50Hz, ISI marked and complete all as specified and directed |
| 57 | S&F MCB SPN 32 - 40 Amps 10 KA, \"C\" series, AC, 240Volts, 50Hz, ISI marked and including removing old unsp items complete all as specified and directed |
| 58 | Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or upto 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per elecrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh, including charcoal, salt packed all around the earth electrode plage in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45CM, RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed |
| 59 | Excavation in post holes (or similar holes) each not exceeding 0-50 cum, in soft/loose soil, getting out, returning filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering or removing surplus soil to a distance not exceeding 50 m & making good surface complete all as specified & directed |
| 60 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161-1998 grade ST-240 complete all as specified & directed. |
| 61 | M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing(Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified & directed. |
| 62 | S&F Pre-painted galvalueme aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified & directed. |
| 63 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described & apply two coat of synthetic enamel (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified & directed. |
| 64 | Taking down old unsv/burnt LT panels/Feede pillar panels in any capacity and supply, install, testing and commissinoning LT panel board outdoor type of size 1400 mm long X1400 mm width X 500 mm thickness(depth) with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3.15 mm thickat outer sheet and 2.0 mm thickat internal compartments CRCA sheet andnecessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame ofheight 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4)type B1 with studs,bolts,nuts & washersas per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified.(ii)The contractor shall be arrangedGeneral (SLD), circuitlay out drawings & Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering. (i)Incoming:- MCCB,4 pole,415 Volts Manual drawout type with microprocessor release of capacity 400 Amps complete all as speficied and directed.-01 Nos (ii) Outgoing :- ON-Load change over switch with front operated handle 400 to 630Amps,415Volts 4 Poleinclsteelcoatedfactory fabricated spreader links & steel nuts,bolts and washers of suitable apms rating in RYB &N. 01 Nos(iii)Outgoing:-MCCB 250 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos(iv)MCCB 200 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos(iv)MCCB 160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos (v)MCCB 63/100 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos (vi)MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCBincl spreader links of suitable ratings (vii)MCCB 63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos02 X spare compartments for MCCBincl spreader links of suitable ratings.(viii)R,Y,B Phase indicating lamp -01 Set (ix)Digital Ammeter (0 amps to 500 Amps) selector switch -01 No.(x)Ammeter Selector switch -01 No.(xi) 400/5A current transformer -03 No\"s (xii)Digital Voltmeter( 0Voltsto 500Volts)-01 No with ASS, (xiii) Volmeter selector switch -01 No with VSS (xiv)Protection fuses& controll wiring-03 Nos(xv) Main bus bar TPN 1000 Amps 01 Set ( 04 Nos) and out goingdistribution busbar size andamps rating x1.5 times ratingaluminium busbar-01 Set ( 04 Nos) |
| 65 | Taking down old unsv/burnt LT panels/Feede pillar panels in any capacity and supply, install, testing and commissinoning LT panel board outdoor type of size 1300 mm long X1300 mm width X 500 mm thickness(depth) with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3.15 mm thickat outer sheet and 2.0 mm thickat internal compartments CRCA sheet andnecessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame ofheight 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4)type B1 with studs,bolts,nuts & washersas per site requirement. And complete all as specified and directed and including comprising of following:- Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified.(ii)The contractor shall be arrangedGeneral (SLD), circuitlay out drawings & Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering.(iii) Name of LT panel Manufacturers :- M/S UTKAL Electrical Industries / M/S Girija Electricalsor as approved and followed by CPRI norms/certified or equivalent approved manufacturers only. (i)Incoming:- MCCB 320A,4 pole,415 Volts Manual drawout type with microprocessor release of capacity 250 Amps complete all as speficied and directed.-01 Nos (ii) Outgoing :- ON-Load change over switch with front operated handle 315to 400Amps,415Volts 4 Poleinclsteelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos (iii)Outgoing:-MCCB 160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos (v)MCCB 125 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos(vi)MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCBincl spreader links of suitable ratings. 01 Nos (vii)MCCB 32-63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos02 X spare compartments for MCCBincl spreader links of suitable ratings.01 Nos (viii)R,Y,B Phase indicating lamp -01 Set (ix)Digital Ammeter (0 amps to 500 Amps) selector switch -01 No. (x)Ammeter Selector switch -01 No.(xi) 400/5A current transformer -03 No\"s (xii)Digital Voltmeter( 0Voltsto 500Volts)-01 No with ASS, (xiii) Volmeter selector switch -01 No with VSS (xiv)Protection fuses& controll wiring-03 Nos (xv) Main bus bar TPN 500 Amps 01 Set ( 04 Nos) and out goingdistribution busbar size andamps rating x1.5 times ratingaluminium busbar-01 Set ( 04 Nos) |
| 66 | Taking down old unsv/burnt LT panels/Feede pillar panels in any capacity and supply, install, testing and commissinoning LT panel board outdoor type of size 1200 mm long X1200 mm width X 400 mm thickness(depth) with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3.15 mm thickat outer sheet and 2.0 mm thickat internal compartments CRCA sheet andnecessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame ofheight 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4)type B1 with studs,bolts,nuts & washersas per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified.(ii)The contractor shall be arrangedGeneral (SLD), circuitlay out drawings & Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering.(iii) Name of LT panel Manufacturers :- M/S UTKAL Electrical Industries / M/S Girija Electricalsor as approved and followed by CPRI norms/certified or equivalent approved manufacturers only.(i)Incoming:- MCCB,4 pole,415 Volts Manual drawout type with thermal based release of capacity 250 to 315 Amps complete all as speficied and directed.-01 Nos (ii) Outgoing :- ON-Load change over switch with front operated handle 250Amps,415Volts 4 Poleinclsteelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos(iii)Outgoing:-MCCB 125-160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. (v)MCCB 100-125 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos(vi)MCCB 63-100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCBincl spreader links of suitable ratings 01 Nos(vii)MCCB 12-63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos02 X spare compartments for MCCBincl spreader links of suitable ratings. 01 Nos(viii)R,Y,B Phase indicating lamp -01 Set(ix)Digital Ammeter (0 amps to 500 Amps) selector switch -01 No.(x)Ammeter Selector switch -01 No.(xi) 400/5A current transformer -03 No\"s (xii)Digital Voltmeter( 0Voltsto 500Volts)-01 No with ASS,(xiii) Volmeter selector switch -01 No with VSS (xiv)Protection fuses& controll wiring-03 Nos (xv) Main bus bar TPN 320 Amps 01 Set ( 04 Nos) and out goingdistribution busbar size andamps rating x1.5 times ratingaluminium busbar-01 Set ( 04 Nos) |
| 67 | Taking down old unsv item from existing location and supply and fixMCCB,160 Amps,4 pole,415 Volts , 35 KA microprocessor based releasetype with necessary lugs,thimbles, nuts bolts and washersand including removing old unserviceable itemcomplete all as specified and as directed. |
| 68 | Taking down old unsv item from existing location and supply and fixMCCB,250 Amps,4 pole,415 Volts , 35 KA microprocessor based releasetype with necessary lugs,thimbles, nuts bolts and washersand including removing old unserviceable itemcomplete all as specified and as directed. |
| 69 | Taking down old unsv item from existing location and supply and fixMCCB,200-250 Amps,4 pole,415 Volts , 16/18/35KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washersand including removing old unserviceable itemcomplete all as specified and as directed. |
| 70 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 16 sqmm,4 core complete all as specified and directed. |
| 71 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 25 sqmm,4 core complete all as specified and directed. |
| 72 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 35 sqmm,3.5 core complete all as specified and directed. |
| 73 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 50 sqmm,3.5 core complete all as specified and directed. |
| 74 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 70 sqmm,3.5 core complete all as specified and directed. |
| 75 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 95 sqmm,3.5 core complete all as specified and directed. |
| 76 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 120 sqmm,3.5 core complete all as specified and directed. |
| 77 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 185 sqmm,3.5 core complete all as specified and directed. |
| 78 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 240 sqmm,3.5 core complete all as specified and directed. |
| 79 | Supply and Fixing of Change over switch with encloser of capacity 250 Amp , 3 Phase , 4 Pole Each complete including taking out of old /burnU/s changeover complete all as specified |
| 80 | Taking down old unsv item from existing location and material and labour for M& L for galvanized strip iron 25 x4 mm as earthing lead complete all as specified and directed |
| 81 | Taking down old unsv item from existing location and material and labour for M& L for galvanized strip iron 32 x6 mm as earthing lead complete all as specified and directed |
| 82 | Taking down old unsv item from existing location and material and labour for M& L for copper strip20 x3 mm as earthing lead complete all as specified and directed |
| 83 | Supply, installation, testing & commissioning silent generating set with accoustic enclosure of capacity 15 KVA Diesel Engine driven 3 phase 415 VoltS,4 wire,50 hz ,0.8 PF,1500 RPM engine as per IS : 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears control panel having meter and sound proof canopy as per CPCB IV+Norms and suitable foundation etc. complete all as specified & comprising of the following :-(a) Prime Mover : Suitable for driving 30 KVA alternator, battery (electric start) diesel engine of suitbale capacity BHP confirming latest IS and a fueltank suitable for 12 hours consumption capacity mounted on MS frame pedestal support, rated for continues running, capable of taking 10% over load for one hour in any 12 hrs operation taking into consideration de-rating due to altitude/temp & complete with following standard accessories. (i) Fly wheel and fly wheel housing to match with the flexible coupling. (ii) Flexible coupling with guard.(iii)Air cleaner dry type.(iv) Lubricating oil filter,flow paper element type.(v) Blower type fan. (vi) Fuel pump. (vii) Governor class \"A\" governing as per latest IS. (viii)Turbo charger (ix)Fuel Tank,(x) Batteriey/s and leads,(xi) Residential silencer(xii)Std Control Panel,(xiii)First fill of Lube Oil & Coolant,(xiv)AVM pads (xv) Acc Supply installation testing and commissioning DG set 30 KVA with standard panels, cables fdn etc confirming to CPCB IV Norms |
| 84 | M&L Earthingcompletewith galvanisedsteelearthplateelectrode 600x600x6mm burrieddirectlyin groundnotless than 2.25mtr deepbelow normal ground level with top edgeof earth plate not less than 1.5mtrbelow normal ground level connected to the Galvanised iron strip 32x6mm sizeby meansof bolts ,nuts,check nutsandwashersof galvanisediron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm boreincl provision of concrete pit in PCC1:2:4 typeB-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPMweight not less than 4 Kg /Sqm and 6mm diabar handle ,excavationand earthworkin any type of soil ,charcoaldustand saltlightgrade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GIprotectionpipe 40 mm bore 5 Mtr long and GI strip upto main earthingof polecomplete all as shown in electrical plateNo 3 of MES Sch 2009 Part-I all as specifiedand directed. Notes:- (i)Main earthing strip from earth plate electrode to test point uptolength of 7.5 metres length shalldeem to be included in the unit rate quoted against this item.(ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for seperately under appropriate item of Sch A part-I.(iii) On testing after completion ifdesired resistanace is not obtained, the contrator shall redo the earthing without any extra cost to the department. |
| 85 | S&F in repair/ repalcement of on load change over switches 4 pole 100A in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 86 | Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 25 Sqm 3.5 core all as specified and directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy