| Sl. No. | Item Description |
| 1 | Dismantling of floor, hearth, walls, roof tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed. |
| 2 | Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed. |
| 3 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even andrough (as in levelling course) to receive the topping layer complete all as specified and directed. |
| 4 | M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6for laying of floor tiles complete all as specified and directed. |
| 5 | M & L coloured vitrified tiles Light shade 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 6 | M&L for lead free industrials tiles of size 30x30 cm x 6mm thick of approved make endena of Johnson, Kajaria Ceremics, somany complete with fixing materials as perManufactures insfructous and guidelines specifications to be followed with DGMS-3E/01 dt 31 dec 2024 on walls as directed by engineer -in -charge . |
| 7 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 8 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 9 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm longfasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing withselected quality glass. (Note: The unit rate quoted by contractor includes cost of glass and panel and includes all other connected accessories) |
| 10 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories.) (Area not exceeding 2.00 sqm) |
| 11 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 12 | M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 14 | Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 15 | M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 16 | M&L for applying two coats of oil bound distemper on wall or concrete surfaces on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 17 | M&L preparation of old painted surfaces and applying one coat of white wash but on ceiling complete all as specified and as directed. |
| 18 | S&F door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight between 36 to 60 Kg of aluminium (Die cast) body complete all as specified and directed. |
| 19 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removingmaterials to store forkeeping in safe custody or for taking credit (credit for above items should be made for conditions separately )and including making good the disturbed surfaces to match with existing surface and colour shade with proper puttyfor smooth finishing without undulations complete all as specified and directed.( Note:-All credit materials should be deposited in MES yard as available on work site the same materials should be issued to contractorthrough gate passas per schedule of credit materials againstcontract agreement). |
| 20 | Material and labour for cutting chasing,pinning ofbrick/ stone/concrete wallat any height wall cutting and chases for concealedwiring for 25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed |
| 21 | Materialand labour for point wiringand circuit wiring from distribution board to control switch boardwith 1.5 sqmm PVC insulated wires, FRLSH type complete incl suitable, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 25 mm dia medium grade(MMS) andincluding cutting, chasing work at any height and all accessoriesconcealed/surface(as per site)inwalls / roofs / floors / ceiling etc. flush mountingMS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.20mm thick suitable for fixing of andincludingwhite/Silver/Dark bronzecolour modular blankingplate as per number of switch modules flush mountedfor fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colourmodular plate cover of required modules andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with 3mm putty and necessary distamber for smooth finishing complete all as specified and directedfor One light point controlled by one 10 Amps switch one way (Note:- Allnecessary accessories such asmodular box,top cover plate, blank plate,MS box,screws,washers and all modular electrical fixtures are used same make/brand only and including cutting & chasing work at any height/places(incl stone bldgs) it shall be deemed in to included in quoted rate only.) |
| 22 | All as per item no. 21 but for Onefan point controlled by one 10 Amps switch and oneregulator. |
| 23 | All as per item no. 21 but for Oneexhaust fan point controlled by one 10 amps switch . |
| 24 | All as per item no. 21 but for One 5 pin 6 amps socket point controlled by one 10 amps switch on independent board . |
| 25 | All as per item no. 21 but for One 5 pin 6 amps socket point controlled by one 10 amps switch on same board . |
| 26 | All as per item no. 21 but forOne bell/buzzer point controlled by onebell push. |
| 27 | All as per item no. 21 but for One light point controlled by two 2 way switches/bed switch point |
| 28 | All as per item no. 21 but for point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switchon independent board. |
| 29 | All as per item no. 28 but forOne 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on same board. |
| 30 | All as per item no. 21 but forpoint wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. |
| 31 | Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC,ISI Markedcomplete all as specified and directed. |
| 32 | Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC,ISI Markedcomplete all as specified and directed. |
| 33 | Supply & fixing modular type bell push10 Amps,1 module, single pole, 240 volts,AC, ISI Marked complete all as specified and directed. |
| 34 | Supply & fixing modular type switch 16/20 Amps, single pole,1way,1 module,240Volts, ISI Marked complete all as specified and directed. |
| 35 | Supply & fixing modular type socket shuttered type 10 Amps, 2/3 Pin combined 2 module,240V,ACISI Marked complete all as specified and directed. |
| 36 | Supply & fixing modular type socket 16/20 Amps, 6 Pin combined shuttered socket 2 module,240V,ACISI Markedcomplete all as specified and directed |
| 37 | Supply & fixing red color lighting indication lamp switch, single pole,240volts,AC,50 Hz suitable for 1 moduleISI Marked complete all as specified and directed. |
| 38 | Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 1 to 8 steps,ISI Markedcomplete all as specified and directed. |
| 39 | Supply and fix call bell AC, 230 Volts single pole, multi music type best and superior quality,ISI marked, as approved type complete all as specified and directed. |
| 40 | Supply & fix angle lamp holder latest model, insulated PVC out side body and brass inside holder with back plate for batten fittings/bulbscomplete all asspecified and directed. |
| 41 | Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 42 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 43 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 44 | Supply and fixing LED wall mounted security lights 30/35watts,IP-65 ProtectionSupply &fixing , in repairs LEDbldg secruity light fitting of capacity 60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionand including removing of old unserviceable item complete all as specified and directed. |
| 45 | Supply and fixed in repairs recess mounting 2\"x2\" LED 40/42 Watt light fitting slimmest 9 mm thin in class LED ceiling panel with best in class aesthetick white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm mudular ceiling grid and also can besuspended with provided kit and including connecting up with ceiling rose to fittingand including removing old unserviceable item complete all as specified and directed complete all as specified and directed. |
| 46 | S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired ofluminaires including LED light driver and connected with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed. |
| 47 | Supply & fixingand sheet metal enclosurewith acrylic door type, double door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection and includingremoving old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 48 | Supply & fixing andsheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 49 | Supply & fix and in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board 12 wayfor flush mounting with 100amps copper busbar,neutral bar,earth bar suitable for MCB incomer of rating upto 100Amps ,MCB SPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plates withIP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coatall as specified and as directed. |
| 50 | Supply & fixMCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed. |
| 51 | Supply & fix and MCB SPN 32 to40 Amps 10 KA,\"C\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. |
| 52 | Supply & fix and MCB SPN 40 to63 Amps 10 KA,\"C\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. |
| 53 | Supply & fix and MCB TPN 4063 Amps 10 KA,\"C\" series,AC,415Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. |
| 54 | M & L for sub main wiring complete with 4 run of 10 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit 25 mm dia in concealed ISI marked medium grade(MMS) ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Four run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 55 | M & L for sub main wiring complete in repairs with 2 run of 10 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn drawnthroughand including PVC conduit 25 mm dia in concealed ISI marked medium grade(MMS) accessories such as Tee,corner, overlaping connector etcand including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 56 | M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit25 mm dia ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring andmaking good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 57 | M & L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit 25 mm dia ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 4.0 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 58 | Supply and fixsuitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20Amps, 10KA \"C \"series, 230 Volts,50Hzsuitable for AC\"s/Geysers complete all as specified and directed. |
| 59 | Supply and fixMCCB,125 Amps,4 pole,415 Volts , 16/18/35KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washersand including removing old unserviceable itemcomplete all as specified and as directed. |
| 60 | Supply and fix air circulator heavy duty turbo force wall mounted,metal body type fan 230Volts single phase oscillating 450 mm sweep and all connected accessories and including providing hanging heavy duty GI plate/clamp, nuts, bolts and washers complete all as specified and directed. |
| 61 | Supply & fix ceiling fans complete with blades, down rods, and connected accessories, 230 V, 1200mm sweep. Min air delivery 225 CFM with service value 6.00 BEE,Star rated with brushless direct current motor complete all as specified and directed. |
| 62 | Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC/(PVC hevy duty cover) cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 63 | S&F for PVC non-metalic rigid conduit 25MM dia incl looping boxes,junctions boxes 1 to 4 way & terminals and incl providing all types accessories such as tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers lock nuts,saddles,pipes hookes etc ISI markedfor LAN,telephone and TV connections cables includingtiles cutting,chasses and making good disturbed surfaces to match with existing colour tiles surfaces with plaster/putty and including removing of old unserviceable item complete all as specified and directed. |
| 64 | Supply and fixingsheet steelenclosure in CRCA sheet suitable for MCCB100Ampsto 160Amps,4pole,415Volts,16/18KA MCCB and including providing necessary nut,bolts and washers and fixed in wall concealed/surface as site conditon complete all as specified and directed. |
| 65 | Taking down old unserviceableair conditions complete indoor and outdoor units and incl disconnecting the electrical connections from switch board, MS stand etc from existing bldgs/location without any damages andfurther deposited in MES store yard for safe custodyand Supply and fixing, install, new wall splitindoor & outdoor unit of capacity 1.8 TRto 2.2 TRwith copper condenser complete,dual/swing inverter type compressor, complete with cordless remote control unit with suitable batteries and remote holder and complete indoor and outdoor units and standard accessories i.e necessary copper tube as per site requirement, Heavy duty MS stand for out door unit,indoor unit plug top,holefastners,necessary suitable three core PVC sheathed copper conductor for inter connections indoor and out door units, heavy suty drain pipe from indoor unit to outside bldg with minimum 5 star ratingcomplete all as specified and directed. |
| 66 | Taking down and disconnected old unserviceable voltage stabilizer complete from existing bldgs/location without any damages andfurther deposited in MES store yard for safe custody Supply and fixnew metal body heavy duty digital voltage stabilizer for automatic operation,single phase,digital display type,inpuit and output display naturally air cooled indoor type & designed for input variation between 90 volts to 300 volts,15A with out voltage stabilized at20 volts with accuracy of± 2.5%and of capacity 5.0 KVAnecessary fixing arrangements such as screws, fastners, and washers complete all as specified and directed. |
| 67 | Supply and fix mini MCB,32 A,DP \"C and motor starter including with suitable sunken box in concealed/surface and internally connected properly suitable for cooking electrical appliancesincluding protection and includingremoving old unserviceable items and making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 68 | Supplying and laying of CPVC /UPVC pipes SDR 11 & Plain SDR 11 incl allfittings ( bens, Tee, long bend, coupling,short pieces etc) of outer dia 32 -40 mm laying in floors/in walls /in trenches etc with clampingcomplete all as specified |
| 69 | Taking down old unsv/burnt LT panels/Feede pillar panels in any capacity and supply, install, testing and commissinoning LT panel board outdoor typewith double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3.15 mm thickat outer sheet and 2.0 mm thickat internal compartments CRCA sheet andnecessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame ofheight 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4)type B1 with studs,bolts,nuts & washersas per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certifie.(ii)The contractor shall be arrangedGeneral (SLD), circuitlay out drawings & Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering.(i)Incoming:- MCCB,4 pole,415 Volts Manual drawout type with microprocessor release of capacity 400 Amps complete all as speficied and directed.-01 Nos. (ii) Outgoing :- ON-Load change over switch with front operated handle 400Amps,415Volts 4 Poleinclsteelcoatedfactory fabricated spreader links & steel nuts,bolts and washers of suitable apms rating in RYB &N.01 Nos (iii)Outgoing:-MCCB 250 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos (iv)MCCB 200 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos(iv)MCCB 160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos (v)MCCB 63/100 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos (vi)MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCBincl spreader links of suitable ratings 01 Nos(vii)MCCB 63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos02 X spare compartments for MCCBincl spreader links of suitable ratings 01 Nos (viii)R,Y,B Phase indicating lamp -01 Set (ix)Digital Ammeter (0 amps to 500 Amps) selector switch -01 No. (x)Ammeter Selector switch -01 No.(xi) 400/5A current transformer -03 No\"s Make:-Kappa (xii)Digital Voltmeter( 0Voltsto 500Volts)-01 No with ASS, (xiii) Volmeter selector switch -01 No with VSS(xiv)Protection fuses& controll wiring-03 Nos(xv) Main bus bar TPN 1000 Amps 01 Set ( 04 Nos) and out goingdistribution busbar size andamps rating x1.5 times ratingaluminium busbar-01 Set ( 04 Nos) |
| 70 | Taking down old unsv/burnt LT panels/Feede pillar panels in any capacity and supply, install, testing and commissinoning LT panel board outdoor typewith double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3.15 mm thickat outer sheet and 2.0 mm thickat internal compartments CRCA sheet andnecessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame ofheight 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4)type B1 with studs,bolts,nuts & washersas per site requirement. And complete all as specified and directed and including comprising of following:- Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified.(ii)The contractor shall be arrangedGeneral (SLD), circuitlay out drawings & Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering.. (i)Incoming:- MCCB 320A,4 pole,415 Volts Manual drawout type with microprocessor release of capacity 250 Amps complete all as speficied and directed.-01 Nos . (ii) Outgoing :- ON-Load change over switch with front operated handle 315to 400Amps,415Volts 4 Poleinclsteelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos . (iii)Outgoing:-MCCB 160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N 01 Nos. (v)MCCB 125 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos(vi)MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCBincl spreader links of suitable ratings 01 Nos (vii)MCCB 32-63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos02 X spare compartments for MCCBincl spreader links of suitable ratings01 Nos .(viii)R,Y,B Phase indicating lamp -01 Set(ix)Digital Ammeter (0 amps to 500 Amps) selector switch -01 No.(x)Ammeter Selector switch -01 No. (xi) 400/5A current transformer -03 No\"s (xii)Digital Voltmeter( 0Voltsto 500Volts)-01 No with ASS, (xiii) Volmeter selector switch -01 No with VSS (xiv)Protection fuses& controll wiring-03 Nos (xv) Main bus bar TPN 500 Amps 01 Set ( 04 Nos) and out goingdistribution busbar size andamps rating x1.5 times ratingaluminium busbar-01 Set ( 04 Nos) |
| 71 | Taking down old unsv/burnt LT panels/Feede pillar panels in any capacity and supply, install, testing and commissinoning LT panel board outdoor type with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3.15 mm thickat outer sheet and 2.0 mm thickat internal compartments CRCA sheet andnecessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame ofheight 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4)type B1 with studs,bolts,nuts & washersas per site requirement. And complete all as specified and directed and including comprising of following:- Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified. (ii)The contractor shall be arrangedGeneral (SLD), circuitlay out drawings & Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering. (i)Incoming:- MCCB,4 pole,415 Volts Manual drawout type with thermal based release of capacity 250 to 315 Amps complete all as speficied and directed.-01 Nos (ii) Outgoing :- ON-Load change over switch with front operated handle 250Amps,415Volts 4 Poleinclsteelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos (iii)Outgoing:-MCCB 125-160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos(v)MCCB 100-125 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos (vi)MCCB 63-100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCBincl spreader links of suitable ratings 01 Nos (vii)MCCB 12-63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos02 X spare compartments for MCCBincl spreader links of suitable ratings.01 Nos (viii)R,Y,B Phase indicating lamp -01 Set (ix)Digital Ammeter (0 amps to 500 Amps) selector switch -01 No.(x)Ammeter Selector switch -01 No.(xi) 400/5A current transformer -03 No\"s (xii)Digital Voltmeter( 0Voltsto 500Volts)-01 No with ASS, (xiii) Volmeter selector switch -01 No with VSS(xiv)Protection fuses& controll wiring-03 Nos (xv) Main bus bar TPN 320 Amps 01 Set ( 04 Nos) and out goingdistribution busbar size andamps rating x1.5 times ratingaluminium busbar-01 Set ( 04 Nos) |
| 72 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 16 sqmm,4 core complete all as specified and directed. |
| 73 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 25 sqmm,4 core complete all as specified and directed. |
| 74 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 35 sqmm,3.5 core complete all as specified and directed. |
| 75 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 50 sqmm,3.5 core complete all as specified and directed. |
| 76 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 70 sqmm,3.5 core complete all as specified and directed. |
| 77 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 95 sqmm,3.5 core complete all as specified and directed. |
| 78 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 120 sqmm,3.5 core complete all as specified and directed. |
| 79 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 185 sqmm,3.5 core complete all as specified and directed. |
| 80 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 240 sqmm,3.5 core complete all as specified and directed. |
| 81 | Supply and Fixing of Change over switch with encloser of capacity 250 Amp ,3 Phase ,4 Polecomplete including taking out of old /burn U/S changeover.complete all as specified . |
| 82 | Taking down old unsv item from existing location and material and labour for earthing of machinery/equipment installed at power house/substation,using 4 mm GI wire and MS Galvanized plate of size 600x600x3 mm as earth electrode complete all as directed |
| 83 | Taking down old unsv item from existing location and material and labour for M& L for galvanized strip iron 25 x4 mm as earthing lead complete all as specified and directed |
| 84 | Taking down old unsv item from existing location and material and labour for M& L for galvanized strip iron 32 x6 mm as earthing lead complete all as specified and directed |
| 85 | Taking down old unsv item from existing location and material and labour for M& L for copper strip20 x3 mm as earthing lead complete all as specified and directed |
| 86 | Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft /loose soil complete all asspecified and directed. |
| 87 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed |
| 88 | Removing excavated soil not exc50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed |
| 89 | M & L for brick sub class \"B\" 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cablecomplete all as specified and directed. |
| 90 | Material & labour for GI pipe 100 mm \"light grade\" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed. |
| 91 | Material & labour for GI pipe 80 mm \"light grade\" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed. |
| 92 | Material & labour for GI pipe 50 mm \"light grade\" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed. |
| 93 | Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. |
| 94 | Taking down old unsv item from existing location and material and labour for earthing of machinery/equipment installed at power house/substation,using 32x6 mm GI strip and MS Galvanized plate of size 600x600x3 mm as earth electrode complete all as directed |
| 95 | S&F in repair of PP-R gate valves (brass inlet) as per requirement of size 63 mm OD complete all as specified and directed. Make :SFMC or equibalent in approved by E-in-C |
| 96 | Supply in replacement of Brass Non return valve as per requirement of the site of size 50 mm dia complete all as per spcefified and directed. |
| 97 | M&L for boring /drilling bore of dia suitable for 200/250mm dia HDPE pipes by any suitable method (by DTH-cum-rotary or reverse rig method or hammering method) by reaming upto 300mm dia to a depth of 60 mtrs in any type of soil including disposal of materials obtained (soils boulders etc) from boring to a distance not exceeding 50 mtrs with & including collection of logical samples (drilling/cutting) & to maintain drill time log book complete all as specified and directed. |
| 98 | Development of borewell including flushing out ftree routs, fine sand by air compressor of suitable capacity not less than 450 CFM at 150 PSI & over pumping (25% extra capacity pump) to make water free from turbidity till clear water is obtained from bore well complete all as spceified and as directed (pumping for minimum 16 hours, the upper limit for duration of development as per IS.. nothing extra shall be payable on account of increase in numbers of pumping hours actually required at site in excess of minimum period as above. |
| 99 | M&L lowering casing pipe 200mm dia HDPE pipe of material grade PF-80, PN 10 (pressure rating 10 Kg per sqcm) DN 200, confirming to IS-4984 (1955) for protection of sides from falling during the process of drilling including required cutting, jointing etc complete all as specified and as directed |
| 100 | Filling annular space between casing pipe & bore hole with & including river bed stone pebbles of size/ grading 5 to 8 mm dia including packing complete all as specified & directed |
| 101 | M&L for yield test for bore hole after completion of development of bore well by pumping of 16 hours to determine the safe pumping yield complète all as specified and as directed |
| 102 | S&F steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia for holding of submersible pump motor set complete all as specified and as directed |
| 103 | S&F bore cape of size 200/250 mm dia with MS clamp for holding of pump set and column pipe complete all as specified and as directed |
| 104 | S&F submersible cable weather proof with multistraded copper conductor 3 core of size 6 sqmm 1100 volts grade heavy duty including all accessories for connecting pumpto panel board, testing and commissioning complete all as specified and as directed |
| 105 | Supply and fixing submersible pump, electric driven 415 v. TP suitable for 200/250 mm bore well (Casing pipe size200/250mm)supply and install 5 HP, 40 mtr Head, 105LPM, 38mm outlet (Model KS4C-Series Make Kirloskar/CRI including lowering by manpower & mechanical complete all as specified and directed. |
| 106 | S&F GI Pipe 50mm dia & 3 meter long (ISI Marked) class \"C\" heavy duty column pipe, with long screwed end, with 100 mm long Gl socket heavy duty. fixed with spot welding complete all as specified |
| 107 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burned directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron strip 32mm X 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of Gl and GI strip protected by provision of Gl pipe light grade, 40mm bore upto test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1,75 metres long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement. funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-l and connection to earth test point all as specified and testing on completion.NOTE: Item of earthing includes the cost of 7.5 metre long galvanised iron stnp 32mm X 6mm size and protection pipe of 40 mm bore galvanised iron light grade. |
| 108 | Supply, laying and testing PVC insulated, armoured heavy duty electric cable, screened PVC bedded, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve including taking out existing unserviceable cable complete all as specified and directed for size 10 sqmm 4 core complete all as specified and directed |
| 109 | Excavation of trenches in any type of soil n.exc 1.5 M wide and nexc Cum 13 1.5 M in depth for taking out/laying of pipe lines and getting out forming bottom surfaces to required gradients complete all as specified and as directed |
| 110 | Returning, filling in and including spreading, leveling, watering and well ramming in layers niexc 25 cm thick complete all as specified and directed |
| 111 | Removing excavated surplus materials to a distance not exceeding 50 Mtrs and deposited where directed at a level not exceeding 1.5 Mtr. Above starting point complete all as specified and directed |
| 112 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 3 cm above the cable complete all as specified and directed Note Punned thickness shall be measured for the purpose of payments. |
| 113 | Supply and laying bricks common burnt clay flyash building bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and directed |
| 114 | Supply, fabricate, erect, test and commission outdoor LT panel totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ AC supply, factory made, fully compartamentalised made out of 3 mm thick CRCA sheet steel size 1200mmx1000mmx500mm for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 as per IS 2147 of 1962 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, out door type, cubical type as required with and including the follwaing, supplied fitted and connected internally complete including all PCC foundation(a) 4 Nos alluminium bus bar of equal size of aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating 200 Amps-03 Nos and 100Amp-1 No mounted on non cracting resin type insulators with CTs, ammeter and volt meter with selector switches, set of LED type indicating lamps R,Y,B on incoming side(b) MCCB TPN 415 Volt, 40 Amps 10 KA-01 Nos (Incoming)(c) MCCB TPN 415 Volt, 25 Amps 10 KA-01 Nos (Outgoing)(d) Digital volt meter 0 to 500v (L&T)(e) Digital Amp meter 0 to 100 A with selector switch (L&T)(f) Contactor TPN 16 Amp with timer-01 No(g) CT Coil 50/5 (L&T)(h) Suitable starer upto 5HP-01 set(j) Dry run & overload protection-01 Set |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail