| 1 | M&L Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with 3mm thick wall care putty and preparation of surfaces for further treatment and applying two coats of distemper, oil emulsion white or tinted complete all as specified and directed. |
| 2 | M & L for complete removal of existing surfaceof walls of any description by washing, rubbing down and applying two coats of apex paint by machanical applicator over a coat of alkali resistant primer complete all as specified and directed. |
| 3 | M & L preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 4 | Taking down cementplaster any description on brick or stone walls etc including rakingout joints, hacking for key, scrubbing down with wateretccomplete all as specified and directed. |
| 5 | M & L rendering 15 mm thick in CM 1:4 inon surface of walls and finished even and fair (without using extra cement) in patchescomplete all as specified and directed. |
| 6 | M & L rendering 15 mm thick in CM 1:6 inon surface of walls and finished even and fair (without using extra cement) in patches complete all as specified and directed. |
| 7 | M & L preparation of new plastered surfaces of walls and applying two coats of exterior emulsion Paint(Apex)overone coat of exterior primer, complete all as specified and directed. |
| 8 | M & L preparation of new plastered surfaces nd finishing the surfaceof walls with wall putty and applying two coats of oil bound distemper overa coat of cement primer of, any colour complete all as specified and directed. |
| 9 | Dismantling of wall/ceiling boards(fibre, pulp, insulation, etc) of any type including cover fillets complete all as specified and directed. |
| 10 | M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm ,using Main and cross tee of size 36.5mmX25mmX1.4mm,weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer\"scomplete all as specified and directed. |
| 11 | M&L 4mm thicknon asbestos fibre designer cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 12 | Dismantling AC/ CGI/ translucent ( corrugated, semicorrugated,etc), complete all as specified and directed. |
| 13 | S&F Pre-painted galvatume aluminium zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridge,etcwith self tapping screws or J hooks complete all as specified and directed. |
| 14 | S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridge,etcwith self tapping screws or J hookscomplete all as specified and directed. |
| 15 | M&L for MS flat (wind tie) as roofsheet securingincl distance pieces, cleatsetc complete all as specified and directed. |
| 16 | Taking down roof trusses,coupled rafters or trussed beam clean span above 4 metre and upto 8 metres complete all as specified and directed. |
| 17 | Dismantling of timber scantling 40 Sqcm and over in section in any position complete all as specified and directed. |
| 18 | M&LSecond class hard-wood in timber framedscantling Clean swan fixed in repair,to replace old and decayed timber (including piecing scarfing,etc,of old and new timber if required)and removing defective portions to store etc complete all as specified and directed. |
| 19 | M&L preparating surfaces of wood and wood based materials new or old ,of any description and girth,not otherwise described and treated with two coat of creosote oil complete all as specified and directed. |
| 20 | M&L roof trusses (framed ), trussed, purlins, rails & fastening and heavy bracket framing (beam, tee, angle, channel, flat, etc) incl distance pieces, cleats , holdfast etccomplete all as specified and directed. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed. |
| 22 | M&L for 9-10mm thick Light coloured vitrified ceramic tiles of sizein floors, not exceeding 0.36 sqm set & jointed in neat cement slurry and pointed in coloured cement to match over & including 20mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 23 | Taking down complete existing treatment of roof/ parapet ,Mud puska on roof /parrapet including plastering, brick tiles, stone slabs and leeping any thickness including removal etc complete all as specified and directed. |
| 24 | M&L PCC 1:2:4 type B-0integral waterproofingchemical PIDIPROOF LWmixed in proportion 200 millilitre per 50 Kg cement of DR FIXIT of PIDILITE INDUSTRIES LTD, or STP No 1 (LIQUID) of STP LTDin proportion 200 millitire per 50 Kg cement, as in padding, benching,Sunken portion etc on roof surface for corecting/making proper slope on roof, etc complete all as specified and directed. |
| 25 | M&L Applying membrane on primed surface by press application method with minimum 75mm longitudnal wise lap and 100mm over lap on the transverse direction duly sticked using 3mm thick APP(Atactic polypropelene polymer) modified prefabricated five layer,weight not less than 3.6kg/Sqmwater proofing membrane,black finished non woven polyester reinforced (wt not less than 150grams ) over applying one coat of bitumenous primer @ 0.4 kg per sqm complete all as specified and directed. |
| 26 | M&L for two coats of bituminous based aluminium paint on APP membrane complete all as specified and directed. |
| 27 | Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete all as specified and directed. |
| 28 | M&L brick work with sub class \"B\" brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 complete all as specified and directed. |
| 29 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |