Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | [B&R PORTION]Demolition of brick work built in CM incl all quions arches, pillar etc all as specified and directed. |
| 2 | Material and labour for brick work with flyash bricks of class designation 75, straight or curved on plan exc 6m mean radius built in cement mortar 1:6complete all as specified and directed. |
| 3 | Material and labour for flyash Brickwork having class designation 75, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 etc complete all as specified and directed. |
| 4 | Taking down Cement plaster on brick or stone walls incl raking out joints hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 5 | Material and labour for Rendering 15 mm thickon surface of any descriptionof brick work or concrete surfaces, finished even and fair (without using extra cement) on walls in cement mortar (1:6), complete all as specified. |
| 6 | Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), using water proofing compound complete all as specified. NOTE:WPC will be measured and paid for separately. |
| 7 | Material and labour for rough cast plastering over and incl 10 mm thick rendering in cement mortar 1:3 and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered. Rough cast plaster shall be applied asspecified clause 14.22 of SSR Part-I , complete all as specified and directed. |
| 8 | Supply only integral water proofing comound ISI Marked complete all as specified and directed. |
| 9 | Material and labour for preparation of new plastered surface of walls and applicataion of two coats of 100% premium acrylic emulsion paint with fully automatic airless spray machine and paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance , dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 lit/10 sqm over and including priming coat of exterior primer applied @2.20kg/10 Sqm complete all as specified and directed |
| 10 | Material and labour for preparation of old plastered surface of walls including removal of existing treatment by mechanical dry wall sander machine and applicataion of two coats of 100% premium acrylic emulsion paint with fully automatic airless spray machine and paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance , dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 lit/10 sqm over and including priming coat of exterior primer applied @2.20kg/10 Sqm complete all as specified and directed. |
| 11 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with fully automatic airless spray machine ,over a coat of alkaline resistant primer and a coat of birla wall care putty surface having minimum thickness 1.00mm complete all as specified and directed. |
| 12 | Material and labour for complete removal of existing treatment on surface of walls by using mechanical dry wall sander machine for complete removal of all layers of treatment and reaching upto old plastered surface and applying a coat of wall care putty not less than 1.5mm thick as per manufacture instructions and applying two coats of oil emulsion paint withfully automatic airless spray machine over a coat of alkaline resistant primer complete all as specified and directed. |
| 13 | Dismantling of AC corrugated, semi corrugated sheet including ridges etc. in roof covering complete all as specified. |
| 14 | Dismantling of ceiling boards (fibre, pulp, insulation, etc.) or insulation boards /slabs/ blankets, any thickness, including cover fillets, false ceilings etc complete all as specified. |
| 15 | Dismantlingwrought iron or mild steel work of any descripiton or in any position all as specified and directed. |
| 16 | Material and labour roof trusses (framed) trussed ,purlins, crane gantries, rails and fastenings and heavy bracket framing ( Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed. |
| 17 | All as per Item No 16.00 above but erection and fixing only incl preparation of old surfaces complete all as specified and directed by Engr-in-charge, (Old truses obtained from item No 15.00) |
| 18 | Material and labour for plates (plain and chequered) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment of Fe-410W(gde-E-250) quality A complete all as specified and directed. |
| 19 | Supply and fixingPre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and as directedby Engr-in-charge. |
| 20 | Supply and fixing Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws etc complete all as specified and as directedby Engr-in-charge. |
| 21 | Supply and fixing false ceilingwith semi perforated 12mm thick micro tegular edged GRG false ceiling tiles at all heights with glass fibre reinforced gypsum false ceiling tiles of size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99% , NRCO 0.50 to 0.75 as per IS 8225:1987, noncombustible as per BS 476 (part 4)- 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @120 gms per sqm on both sides) comprising of main T runners of size 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm , suspended from ceiling using galvanised mild steel item (galvanising @ 80 grms per sqm)ie 50mm long , 4 mm dia GI wire incl neccessary hanging arrangement as per manufacturers instructions. Galvanised iron perimeter wall angle of size 24x24x0.4mm of length 3000mm to be fixed on periphery wall /partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws . The work shall be carried out as per specification , drawings and direction of Engineer-in-Charge. |
| 22 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr in Charge. |
| 23 | Demolition of Cement Concreteas in ground floor and paving n. exc. 15cm thick (above or below ground level) complete all as specified and directed. |
| 24 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material and labour for 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection finished fair and even smooth without using extra cement complete all as specified and directed by Engineer-in-charge.Note:- The plinth protection shall be laid in panels and lenth of each panel shall not be more than 2.00 m all as directe. Also fill 6mm joints filled with 85/25 grade bituman and sand in the ratio 1:3 shall be provided. |
| 26 | Material andlabour for premium quality, coloured, joint free, non skid coloured ceramic tiles, area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, 7 to 8 mm thick as in floor, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including15mm thick screed bed or layer in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material andlabour for premium quality coloured glazed ceramic tiles ( 450 x 300 x 7 mm thick) and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match including rendering 10 mm thick in cement plaster 1:4 as in vertical surfacescomplete all as specified and directed by Engineer-in-Charge. |
| 28 | Material and labour for 15-18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over 15mm thick cement mortar 1:4 screed bed and jointed with grey cement slurry @ 3 Kg/Sqm, and pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite including grinding, polishing, rounding and moulding of stone slabs on edges, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material and labour machine cut pre polishedkota stone slab flooring minimum size 55x55 cm 18-20mm thick over cement screed base 15mm thick in CM 1:6laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 30 | Material and labour pre polished kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed base 10 mm thick in CM 1:4including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 31 | Material and labour for painting to steel surfaces of any description not other wise described over 10cm width or girth with two coats of synthetic enamel paint over one coat of red oxide primer incl preparation of new surfaces complete all as specified and directed by Engr-in-charge. |
| 32 | Taking down chowkaths or frames n.exc 1.5 sqm (without taking off shutter from the frame) each and removing from the site including dismantling brick work for hold fasts etc, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Taking down chowkaths or frames exc 1.5 sqm but n exc 4.0 Sqm (without taking off shutter from the frame) each and removing from the site including dismantling brick work for hold fasts etc, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and fixing of mild steel 300 mm, helical door spring with roller plate for door shutter including welding if necessary fixed in repair complete all as specified and directed. |
| 35 | Supply andfixingof floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 150mm complete all as specified and directed by Engineer-in-Charge. |
| 36 | Material and labour forproviding and injecting chemical emulsion for post constructional antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.50 Ltrs per Sqm of the vertical surfaces of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete all as specified and directed by Engineer-in-Charge.Note : Quantity will be measured perimeter of wall x depth of penetration. |
| 37 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows and other Frames/ Chowkhat of size 50x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position incl MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensionson plus side shall be acceptable but no extra payment on this account shall be made. |
| 38 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows and other Frames/ Chowkhat of size 125 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensionson plus side shall be acceptable but no extra payment on this account shall be made. |
| 39 | Supply and fixing of stainless steel butt hinges 100 mm long medium weight complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) and 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) complete all as specified and directed. |
| 41 | Supply and fixing30 mm thick Factory Made 100% Solid WPC ( Wood polymer Composite ) gauzed and skeleton Shutter of required size comprising of virgin PVC resin of K Value 57-60 (Suspension Grade ),alcium Carbonate andnatural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheetSingle Extruded ( Inner ) with having minimum density not less than 650 kg/cbm manufactured and an ISO 9001 -2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) and 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 Modulus of elasticity 850N/mm2and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. rate inslusive for Fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws incl Aluminum Jali and Stainless wiremess as per required. complete all as specified and directed. |
| 42 | Supply and fixing stainless steel fabricatedtype handle 150 mm long complete all as specified and directed. |
| 43 | Supply and fixing 200 mm long stainless steel barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 44 | Supply and fixing Stainless steel sliding door bolt with hasp, staple (bolt type) 300 mm longand fixing with bolts extruded sections complete all as specified and directed. |
| 45 | Supply and fixing of windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x48mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 48 x 25mm. Outer frame and mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2 Nos of heavy duty stainless steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work including of all taxes, complete all as specified and directed. |
| 46 | Supply and fixing of ventilators made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x48mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 48 x 25mm. Outer frame and mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished with suitableprovision as in ventilator in toilet/bathroom/staircase , complete all as specified and directed. |
| 47 | Material and labour for Painting of old steel surfaces over 10cm width or girth with two coats of synthetic enamel paint incl preparation, complete all as specified and directed by Engr-in-charge |
| 48 | Supply and laying stainlesssteel curtain rod 25mm dia having wall thickness 1.6mmfixed with and including stainless steeldecorative brackets, two lotto for each rod length at both endetcas in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 49 | Taking up or down steel tubing and connections of 15mm bore in pipe , complete all as specified and as directed by the Engineer-in-Charge. |
| 50 | Taking up or down steel tubing and connections of 20mm bore in pipe, complete all as specified and as directed by the Engineer-in-Charge. |
| 51 | Supplying and laying of CPVC pipes 20mm OD SDR 11 and Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified and as directed by the Engineer-in-Charge. |
| 52 | Supplying and laying of CPVC pipes 16mm OD SDR 11 and Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified and as directed by the Engineer-in-Charge. |
| 53 | Material and labour for cuttingchases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends of edges of landings, steps, cills etc., and cutting chases for concealed water tubing and making good complete all as specified and as directed by the Engineer-in-Charge. |
| 54 | Supply andfixing in repair wash basins padstal pattern, vitreous china, white , flat back, size 550x400mm including brackets complete all as specified and as directed by the Engineer-in-Charge. |
| 55 | Supply and fixing pillars taps fancy typechromium plated cast copper alloy with capston head long screwed shanks of 15mm bore complete all as specified and as directed by the Engineer-in-Charge. |
| 56 | Supply and fixing in repairBib tap, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, suitable for 15 mm bore pipe, complete all as specified and as directed by the Engineer-in-Charge. |
| 57 | Supply and fixed in repairs grating doom 100mm dia of PTMT (minimum weight 25 gms) including fixing with white cement complete all as specified and as directed by the Engineer-in-Charge. |
| 58 | Supply and fixing in repair Stop valves, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore complete all as specified and directed by Engineer-in-charge. |
| 59 | Supply and fixing in repair 20mm bore Gun-Metal, globe or gate valves , with iron wheel head,screwed down both end for iron pipe and fixed all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and Fix in repair Soap dish any type, fixed to plugs with chromium plated brass screws, complete all as specified and as directed by the Engineer-in-Charge. |
| 61 | Supply and fixing PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed by the Engineer-in-Charge. |
| 62 | Supply and fixing water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position and incl dismentling complete all as specified and as directed by the Engineer-in-Charge. |
| 63 | Supply and fixingPVC (SWR) 75 mm pipe single socket in any length with rubber ring joints laid in floors or trenches includingdismantling of existing pipes of any description any length complete all as specified and as directed. |
| 64 | Supply and fixing in repairof PVC (SWR) bends 75 mm bore complete all as specified and as directed. |
| 65 | Demolition of RCC type B1 1:2:4 (using 20mm graded stone aggregate) not exc 15cm thick in any position complete all as specified and as directed by the Engineer-in-Charge. |
| 66 | Material and labour for RCC type B-1, 1:2:4 (using 20mm graded stone aggregate) nominal mix in slabs supported on walls beams and columns in floors, roofs, laqndinga, balconies, canopies, deck slabs and in sleves complete all as specified and directed by Engineer-in-Charge. |
| 67 | Formwork to soffits of suspended slabs such as roof slab, floor slab, landing, and similar work n. exc 300 mm thick horizontal or sloping complete fair finished, complete all as specified and directed. |
| 68 | Material and labourReinforcement 10mm dia and over TMT bars including cutting, bending and binding with 0.9mm dia binding wire complete all as specified. |
| 69 | Material and labour PCC type B0 1:2:4 (using 12.mm garded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, coping, kneelers, apex stones , bed plates , water troughs and like including weathering slightly rounded or chamfered angles and throating as directed |
| 70 | Supply andfixing in repair of stainless steel sink with drainage board 1.00 mm thick, ISI marked for kitchen with plug, washers and wastes, including bedding in cement mortar on to dwarf wall or fixing contilever brackets of suitable angle iron, CP brass waste coupling, superior quality PVC waste pipe and connecting union to pipe, over all size 915mm x460mm, bowl size 410mm x 330mm x160mm complete all as specified and as directed by the Engineer-in-Charge. |
| 71 | Supply and fixing in repair of PVC (SWR) floor trap, plain with grating including jointing with solvent cement of outer dia metre outlet of 75 mm complete all as specified and as directed by the Engineer-in-Charge. |
| 72 | Supply and fixing in repaire galvanised mild steel wire cloth 0.56 mm dia of wire and average width of aprature 1.18mm complete all as specified and as directed by the Engineer-in-Charge. |
| 73 | Material and labour for preparation of exposed brick wall surface by cleaning the surface with wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks.Prepared surface should be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day.Note : Further treatment over the surface so achievedwill be carried out only after approval of the same by GE. Note:- This item shall be executed by authorised applicator only. for carrying out efflorescence treatment to exposed and prepared wall surfacehere–in–abovein following sequence :–(a) Prime the prepared surface with one of the following product mixed with cement in 1:1ratio as bonding agent :–(i) Pidicrete URP of M/S Pidilite(ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC (b) Immediately after priming the surface PMM (Polymer Modified Mortar) to be applied \"BY HAND\" while the primer is tacky.10 mm thick PMM should be prepared by mixing one of the following compounds in Cement Mortar 1:3 as per manufacturer\"s instructions :–(i) Pidicrete URP of M/S Pidilite(ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC(c) PMM surface should be allowed to dry one day.After that it shoud painted with two coats of one of the following compound mixed with cement only in ratio of one part of selected com-pound and one point five part of cement :–(i) Pidicrete URP of M/S Pidilite(ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC(d)Now apply two coats of one of the following compound over the surface.These compounds are to be used as per manufacturer instructions :–(i) Pidifin 2K of M/S Pidilite(ii)Brush Coat of M/s Sika(iii) Brush Bond of M/s FOSROCNote : Both coats should be perpendicular to each other and gap between two coats shall be minimum 6 hours.(e) Sprinkle loose coarse sand after second coat while surface is tacky. Note: (i) Item will be executed by authorised applicator of the selected /approved company only. (ii) Every stage of work will be approved by GE then only next layer will be executed by contractor. |
| 74 | Surface excavation n. exc 30 CM deep and averaging 15cm deep in soft/loose soil and getting out including clearing all grass vegetation, saplings, shrubs, brush woods under growth roots and trees, complete all as specified and as directed by the Engineer-in-Charge. |
| 75 | Material and labour for PCC 1:4: 8 type-D2 as in sub base to floor 100mm thick (using 40mm graded aggregate) complete all as specified and directed |
| 76 | Supply and fixing Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with Grey cement andpigment, complete all as specified and as directed by the Engineer-in-Charge. |
| 77 | Material and labour for sand filling under floors or in foundation including watering and consolidation 25mm thickcomplete all as specified and as directed by the Engineer-in-Charge. |
| 78 | [E&M PORTION]Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling rosees, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc, complete all as specified and as directed by the Engineer-in-Charge. |
| 79 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and includingPVC conduit not less than 20mm dia with and including accessories, concealed on wall/ and surface on ceilingand its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flushboxes made out of 1.2mm thick of any module from 2 to 18module conforming to IS-5139(pt-I) of 1969 and IS:14772-2000including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. |
| 80 | Description all as per item No 79.00 here in before but for socket out let point 6 Amps on same board, complete all as specified and as directed by the Engineer-in-Charge. |
| 81 | Description all as per item No 79.00 here in before but for socket out let point 6 Amps on independentboard, complete all as specified and as directed by the Engineer-in-Charge. |
| 82 | All as per srl item No 79.00 here in before but point wiring for one socket out let 16 & 6 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor, complete all as specified and as directed. |
| 83 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. |
| 84 | Supply and fixingmodular switches, one way,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 85 | Supply and fixingmodularswitches, oneway, 16/20 Amps, one module, 230 volt , AC supply, complete all as specified and directed. |
| 86 | Supply and fixingmodular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed. |
| 87 | Supply and fixing modular socket outlet 16/20 amps,3 pin, 2 module, complete all as specified and directed. |
| 88 | Supply and fixing modular fan regulator step type one module / 2 module, 100 W, 230 Volts, 50 Hz, AC complete all as specified and directed. |
| 89 | Supply and fixing of LED luminaries of capacity 20 watt integrated aluminium batten with including Oppel diffuser complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and as directed. |
| 90 | Supply and fixingsurface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housingin CRCA body suitable and including 10 watt LEDhigh efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light complete all as specified and directed. |
| 91 | Supply and fixing Bulk Head Fitting 10 Watt and connected withcopper conductor cable of size 1.50 Sqmm,for fixing the light fittingcomplete all as specified & directed. |
| 92 | Supply and fixing LED wall mounting wall light fittingfixture in metal base, suitable for retrofit LED lamp 7/9 Watt,B-22 compact and energy efficient epoxy powder coated light luminaire including disconnecting and taking down old existing light fitting complete all as specified and as directed by the Engineer-in-Charge. |
| 93 | Supply and fixing ceiling light recess mounted LED flat panel 2\" x 2\" with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided withincluding LED36 watt Cool White/Warm White withprovision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting including disconnecting and taking down old existing light fitting complete all as specified and directed. |
| 94 | Supply and fixing in repair bracket for security light made up of 25/40 mm dia,suitable for security light,0.6 meterlong GI pipe,light grade, 120 degree bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos, 8mm dia bolts with nuts complete all as specified and directed. |
| 95 | Supply and fixingLED security light luminaire 30/35 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 96 | Supply and fixingsheet metal enclosure SP with two pin and earth plug and socket with one single pole, MCB 20/ 32 Amps, \"B\" curve, 240 volts including taking down existing sheet metal enclosure of any size & cap complete all as specified and directed. |
| 97 | Supply and fixing MCB DB4 way TPN double door powder coated complete alongwith 200 Amp rated Bus bar, 415 Volts, IP 54 protection, suitable forMCB 4 Pole 100 Ampas incommer.Note: Thimble/lugs of rating of MCB TPN should be used with wire for fixing in the MCB. Complete all as specified and directed. |
| 98 | Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS: 8623including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed. |
| 99 | Supply and fix MCB TPN100 Amps,440 volt,10 kA, \"B\" curvecomplete all as specified and directed. |
| 100 | Supply and fixing 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 101 | Supply and fixing 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 102 | Supply and fixing 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of SP and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 103 | Material and labour for sub main wiring with two single core FRLSH, PVCinsulatedunsheathed copper conductor cable 6.0 sq mm drawnin and including rigid non metallic PVC medium grade 20/25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSH of 6.0 sqmm,green colourfor earthcontinuity conductor including including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and as directed by the Engineer-in-Charge. |
| 104 | Material and labour for sub main wiring with two single core FRLSH, PVCinsulatedunsheathed copper conductor cable 4.0 sqmm drawnin and including rigid non metallic PVC medium grade 20/25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSH of 4.0 sqmm,green colourfor earthcontinuity conductor including including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and as directed by the Engineer-in-Charge. |
| 105 | Material and labour for taking downceiling fan any type, taking in safe custody and refix the same after completion of repair work including servicing,provision of cable from ceiling rose and painting with synthetic enamel paint by sparying including filling cavities with filler, one coat after cleaning all dust complete all as specified and as directed by the Engineer-in-Charge. |
| 106 | Taking out old unserviceable earthing and material & labour for earthing with Galvanised Steel earth plate electrode 60cmx 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usingGalvanised Iron wire of size 4.0 mmas earthing lead(upto terminal point) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40 mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 1991(Part-I) complete all as specified and as directed by Engineer-in-charge.Note : The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to beincluding in quoted rates. |
| 107 | Supply and fixing in repair sheet steel enclosure with separate busbar chamber for cable terminationwith and including MCCB four pole, 240 volts, 50Hz , breaking capacity 25 kA, 125 Amps, thermal release type,complete all as specified and as directed by the Engineer-in-Charge. |
| 108 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric cable 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core incl taking down existing service connection wire of any size complete all as specified and as directed by the Engineer-in-Charge. |
| 109 | Supply and fixing for GI protection pipe of 40mmdia light grade for cable protection including all fittings laid in trenches or fixed on pole, complete all as specified and as directed by the Engineer-in-Charge. |
| 110 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes, laying of cableetc not exceeding 10 Square metre on plan and getting out in soft/loosesoil complete all as specified and as directed. |
| 111 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed. |
| 112 | Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed. |
| 113 | Material and labour for unwashed dry sandcushioning for cable protection ,filling in trenches/ducts, complete all as specified and as directed. |
| 114 | Material and labour for old size bricks sub class \"B\" for cable protection laid along length of cable complete all as specified and as directed. |
| 115 | Supply, installation and testing of storage type heater (Geyser) of 25 Litres Capacity, vertical type to sustain high pressure upto 8 bars with fixing bolts / fastener, necessary PCC/cement work and making good the disturbed surfaces to match with existing surface giving electric and water connection and testing after installation to entire satisfaction of the Engineer-in-Charge complete with following specifications : - (a) 5 Star rated (Vertical type) Necessary BEE cerificate from OEM shall be produced by the contractor at the time of sample approval. (b) Metal Body.(c) Glass line coated tank (Ferro-glass technology) / Polymer coated.(d) Incoloy glass coated heating element. (e) Adjustable thermostat. (f) Temperature indicator dial/digital type.(g) Multiple Heating Option. (h) Multiple Functional Safety Valve. (j) Thermal Cutout Capillary Type.NOTE : - Warranty certificate to be produced by the contractor from OEM for the following components before processing the bill.(a) For product - 02 Years (b) For metal tank 07 years. |
| 116 | Supply and fixingfor 15mm dia galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc passing through walls for water connection to geyser including, making good the disturbed surface completeall as specified and as directed. |
| 117 | Supply and fixingfor 20mm dia galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc passing through walls for water connection to geyser including, making good the disturbed surface complete all as specified and as directed. |
| 118 | Supply and fixing temperature resistent SS braided pipenot less than 60 Cm long suitable for incoming & out going connections of Geyser with washer etc. complete as an directed. |
| 119 | Supply and fixing Bib Tap cast copper alloy of 15 mm bore with crutch or butter fly handle ,screwed down ,screwed for pipe connection complete all as specified |
| 120 | Supply and fixing stop/Gate valvecast copper alloy of 15 mm bore screwed down ,high pressure with crutch or butter fly handle screwded both end for pipe or for unions and fixed complete all as specified |
| 121 | Material and labour for Point wiring using approved colour coding as per IS with stranded copper conductor 4 Sqmm (nominal area ),single core ,FRLSH PVC insulated and unshaethed stranded cable 1100 volts grade ISI-694 marked in and including heavy duty ,PVC concealed conduit ISI marked for one industrial type metal clad earth plug and socket out let with earth dolly including FRLSPVC Insulated unsheathed copper conductor 4 Sqmm nominal cross section area as earth continuity conductor upto common earth and connecting to common earth dolly complete and including cutting/chasing of wall complete all as specified and directed by Engg in Charge. |
| 122 | Supply and fix sheet metal enclosure with two pin & earth plug and socket comptete with one single pole MCB 20 Amps complete all as specified and as directed by the Engineer-in-Charge. |
| 123 | Supply and fix MCB single pole, 240 Volts 6 to 32 Amps capacity, \"B\" series including fixing in existing DB complete all as specified and as directed by the Engineer-in-Charge. |
| 124 | Material and labour for Cutting and Screwing existing steel tubing in position without taking down for alterations or additions or lengthening screw on pipe toconnector for suitable Bore complete all as specified and as directed by the Engineer-in-Charge. |
| 125 | NOTE:- Amount of credit of Rs. 2,29,426.75 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy