Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-01-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-01-2026 |
| 2 | 12-01-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-01-2026 |
| 3 | 02-01-2026 | Corrigendum No. 01 | BOQ | 12-01-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors & pavings not exc 15 cm thickness below or above ground level including removal of deberies complete all as specified and directed |
| 3 | Demolition of PCC of floors (other than ground floors) complete all as specified and directed. |
| 4 | M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub bases of floors, etc finished the surface even and rough to receive the topping layer complete all as specified and directed. |
| 5 | M&L for 25 mm thick PCC (1:2:4) type B-0 using 12.5 mm graged stone aggregate as in floors, etc complete all as specified and directed.. |
| 6 | M&L forvitrified coloured tiles 10mm thickarea of each tiles size 1200 mm X 600 mm in floors set &jointed in neat cement slurry and pointed in white /coloured cement to match the tiles over and including 15 mmthick screed bed in CM 1:4 including Dismantling floor, hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and directed. |
| 7 | All as per Srl item 06 above butin dado / skirting etc over and including 10 mm thick rendering in CM 1:4. |
| 8 | M&L Non skid ceramic coloured tiles 7 to 8mm mm thick (Square/ rectrangular) area of each tiles600 mm X 600 mm, in floors as joint free etc over and including 15 mm thick cement screed bed in CM 1:6. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 9 | M&L for glazed ceramic joint freecoloured tiles of size600X1200X10mm thick, on vertical surfacesas in skirting/dado etc, set and jointed in neat cement slurry and pointed in white/ coloured cement to match overand including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 10 | M&L for Machine cut kota stone slab of area not less than 0.30 sqm as in flooring as in landing and entrance of staircase, etc. 20mm - 25mm thick laid laid over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4)and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing andpolishing complete all as specified and directed. |
| 11 | All as per BOQ Serial item No.10 above but as in skirting / dado /risers of steps with & including 10 mm thick rendering in CM 1:4. |
| 12 | M&L for Machine cut kota stone single piece slab as in steps treads,windows cill,20-25 mm thick ,over and including 15 mm thick screed in CM(1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing , polishing and rounding to edges of stone slabs one edge,such as in steps, cooking platform, and other similar situations the edges complete all as specified and directed. |
| 13 | Taking down chowkats or frames with shutters (without taking of shutters from the frame) n.exc 1.5Sqm each complete all as specified and directed. |
| 14 | Taking down chowkhats or frames with shutters (without taking off shutter from frames)exc. 1.5 sq. m but not exc 4.0 sqm each,complete all as specified and directed. |
| 15 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi- chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and incl provn of guard bars of 10 mm square MS bar as safety grill, necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, incl all required hardware fitments complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) (Rate of 10 mm square MS bar will be included in the quoted rate and no seperate payment will be given for guard bar) Make : Rajshri / Fenesta / EcocellNote: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 16 | S & F uPVC ventilator with exhaust fan, for ventilation in toilet with (openable type window / Fixed glass as per requirement) of frosted glass with uPVC frame of approved colour, thickness 60 mm, complete all as specified and directed. |
| 17 | M & L for Green Marble work 18 to 20mm thick(table rubbed and polished,) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed. |
| 18 | M&L for 25 mm bore SS Pipecurtain rods with SS brackets & fancy type SS decorative dome fitted to each end, suitablefor door/widows curtain andfixed to wallincluding removal of existing rod/pulmets and making goodcomplete all as specified and directed. |
| 19 | S&F 18 mm thick Action Tesa HDHMR board pre laminated both side (of approved colour) having density more than 850 kg/cum, fixed with screws as in wall panel, storage cabinet/Cub board and built in modular tables etc, for hold of shelf / partation and shall provide 3 edges in sizes 18 mm x 18 mm as per required length.theedgesof shelf / partation / wall side to be lipped with including 18 mm x 1 mm thick laminated sheet of density 850 kg/cum manufactured by as ISO -9000 certified company , lipping portion should be match with laminated colour, using solvent cement etc. (including all necessary brass hardware fitting i.e Piano hinge ,handle, ball catchers including mortice locking arrangement, hole cap including lipping etc, and siliding rail in each Cup board complete all as specified and directed.. |
| 20 | M & Lfor Machine cut cudappah stone slab in racks, cup boards & shelves etc20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade ofslab including ,making grooves in walls to insert, rubbing and polishing complete all as specified and as directed. |
| 21 | M&L for rounding, chamfer, splays or arris and smooth finishingthe edges of stone as in steps, cooking platform and other similar locations complete all as specified and directed. |
| 22 | Taking up or down steel tubing & connections incl cleaning for re-fixing or removal from site for 15 mm dia bore complete all as specified & directed.. |
| 23 | S&F 15 mm bore (ID)CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl fittings and making holes in wallscomplete all as specified & directed. Note:- (i) The holes through wall/floor shall be made/drilled with drill machine or jumper only. After fixing tubing, the holes shall be made good so as to match with the existing surface.(ii) Cutting chassing and it\"s making good , if required shall be measured and paid separately under respective item. |
| 24 | Cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring. etc. and making good, cutting not exceeding 10 cm girth complete all as specified and directed. |
| 25 | Taking up or down steel tubing & connections incl cleaning for re-fixing or removal from site for 20 mm dia bore complete all as specified & directed.. |
| 26 | All as per itemNo. 23.00 here in before but 20mm bore GI medium grade pipe. |
| 27 | S&F 1000 ltr capacity double layer ISI marked rotational moulded polyethyline water storage tank (Cylindrical vertical with closed top) hoisted & fixed in position including provn ofwashout pipe with plug (450mm long,20mm dia medium grade GI pipe) and overflow pipe (600 mm long, 20mm dia medium grade GI pipe) including dismantling of water tank complete all as specified and directed. |
| 28 | S&F 20mm Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixedm complete all as specified and directed. |
| 29 | S&F in repairs 20mm dia bore Gun metal, Globe orgate valves, with iron head or lever screwed both ends for iron pipe fixed, complete all as specified and directed. |
| 30 | S&F in repairs sinks with drainage board made of 1.0mm thick stainless steel sheet kitchen or laboratory with plugs, washers and waste coupling and waste pipeincluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm x 254mm, bowl size 410mm x 330mm x 160mm complete all as specified & directed. |
| 31 | S&F in repair stainless steel plate rack of Size 900mm x 600mm x 250mm made of 1mm thick stainless steel sheet complete all as specified and directed. |
| 32 | S&F in repairvitreous china squatting pan \"Orisa pattern\" size 580x440mmwhitewith integral foot rests any pattern including provn of cement concrete bedding and making connection with & including \"P\" or \"S\" Trap, etccomplete all as specified and directed. |
| 33 | S&F in repair PVC low level flushing cisternof 10 Ltr capacity, dual (5 Ltr / 10 Ltr) valve less including flushing pipe bend PVC bend, PVC connection etc. complete all as specified and directed. |
| 34 | S&F in repair Thin Rim Table top basin of size: 360x360x120 mm Jaquar code : SLS-WHT-6905/ AP Royal Bath Sense Code : TT-70-BGE / Somany in white colour with Click clack waste 32 mm size full thread with 130 mm height Colour Rose Gold Jaquar Code: ALD-BGP-727L130 / AP Royal Bath Sense Code : C230-BGE / Somany Code : 272150830011 modern design with Round shape, slim edges, with tap hole, anti bacterial glaze on ceramic, smooth glaze surface incl fixing on plateform with all required accessories/ fixtures complete in all respect as specified and directed |
| 35 | S&F in repair 15mm bore dia Exposed part kit of single lever basin mixer wall mounted consisting of operating lever, cartridge sleeve, nipple & spout, with colour Blush Gold PVD(Colour Rose Gold) Jaquar Code: KUP-BGP-35233NKPM / AP Royal Bath Sense Code : RGMYDV103U / Somany Code : 272111380111 with concealed body for single lever basin mixer wall mounted Jaquar code : ALD-CHR-233N / AP Royal Bath Sense Code : RGB2BD101 / Somany Code : 272110050101 incl all required accessories/ fixture to make operation complete in all respect as specified and directed by Engr-in-Charge. |
| 36 | S&F in repair 15 mm dia brass chromium plated long body Bib tap fancy type with capstan head screwed down for iron pipe complete in all respect as specified.Make :Jaquar Code OPP-GLD-15037PM / AP Royal Bath Sense Code : RGMYBC101 / Somany Code : 272211380101 |
| 37 | S&F in repair 15mm bore dia Blush Gold PVD (Colour Rose Gold) anglular stop cock with wall flangequarter turn full Antique including cover plate complete in all respect as specified and directed. Make : Jaquar Code : KUP-BGP-35053PM / AP Royal Bath Sense Code : RGMYAC101 / Somany Code : 272211380151 |
| 38 | S&F 15mm bore dia Exposed part kit concealed stop cock & flush cock (Colour Rose Gold) Jaquar Code : KUP-BGP-35083KPM / AP Royal Bath Sense Code : RGMYCC101U / Somany Code :272211380201 with fitting sleeve, Operating lever & Adjustable wall flange with seal, with colour Blush Gold PVD incl regular body of concealed stop cock Jaquar Code : ALD-CHR-083 / AP Royal Bath Sense Code : RGB2DV302 / Somany Code : 272150610021 suitable for 15 mm pipe line with protection cap complete in all respect as specified and directed. |
| 39 | S&F Aquamax Exposed part kit of Thermostatic shower mixer with 3-way diverter Jaquar Code: KUP-BGP-35683PM / AP Royal Bath Sense Code : RGALDV112U / Somany Code : 272111370161 with Colour : Blush Gold PVD (Rose Gold), incl Kubix prime bath Spout with wall flange Jaquar Code: SPJ-BGP-35463PM / AP Royal Bath Sense Code : RGMYSP102 / Somany Code : 272211380301 with Aquamax concealed body of thermostatic shower mixer with 3 way diverter Jaquar Code : ALD-CHR-683 / AP Royal Bath Sense Code : RGB2DV302 / Somany Code : 272110050111Maze overhead Shower 300x300mm Square Shape Single Flow (Body & Face Plate Sttainless steel ) with rubit Cleaning Syatem Jaquar Code: OHS-BGP-1639PD / AP Royal Bath Sense Code : RGBHRF104 / Somany Code : 272141370021 of colour : (Rose Gold) Blush Gold PVD, incl Maze Metal hand shower 90x90mm Square Shape single flow with rubit cleaning Jaquar Code: HSH-BGP-1655PD/ AP Royal Bath Sense Code : RGBHTS102 / Somany Code : 272220080021, Over head Shower arm 600x25x25 mm Square Shape for wall mounted Showers with Flange Jaquar Code : SHA-BGP-455L600 / AP Royal Bath Sense Code : RGSA108N / Somany Code : 272221360011, Flexible tube for hand shower 8 mm dia & 1.5 M long with nuts (Code: SHA-BGP-549D8),wall outlet with shower hook in square shape (Code: SHA-BGP-566SPD) incl cover plate, adjusting leg, concealed diverter and all required accessories/fixture complete in all respect as specified and directed by EIC |
| 40 | S&F Soap Dispenser with glass bottle with (Colour Rose Gold) complete in all respect complete as specified and directed by Engr-in-Charge. Make : Jaquar Code: AKP-ACR-35735P / AP Royal Bath Sense Code : S1LS101 / Somany Code : 272151340071 |
| 41 | S&F in repairs PVC connections with PTMT nuts 15mm bore, 450 in lengthcomplete all as specified & directed. |
| 42 | S&F Towel rack 600 mm long with Lower Hangers, Stainless Steel (Code : AKP-ACR-35781PS) of Colour : Antique Copper complete in all respect as specified and directed by Engr-in-Charge.Make : Jaquar Code: AKP-ACR-35781PS or equivalent in Kohler/Hans Grohe/ Villeroy and boch |
| 43 | M&L for precast cement concrete type B1 (1:2:4) using 20 mm graded aggregate set in CM(1:4) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including use and waste form work complete all as specified & directed. |
| 44 | M&L for 75mm thick PCC 1:3:6,type C-1 (using 20mm graded stone aggregates) as in plinth protection surface finished even and smooth without using extra cement & provided with construction jointon the interval not more than 3.0mfilled with bitumen and sand mortar in 1:3 complete all as specified & directed. |
| 45 | Taking down cement or cement lime plaster any description on brick or stone masonary walls etc. including raking out joints, hacking for key, scrubbing down with water etc and rubbish off the premises complete all as specified & directed. |
| 46 | M & L for cement plaster in two layers on stone / brick masonry surfaces or surfaces other than fair face of brick work, first layer 15mm thick in cement mortar (1:6) and second layer 5mm thick in cement mortar (1:4) with WPC @ 200 ml per bag of cement, finished the surfaces even and smooth without using extra cement complete all as specified & directed.(WPC will measured and paid seperately under respective item) |
| 47 | M&L for preparation of newly plastered surfaces of wall and applying white cement based wall care putty 2mm thick and acrylic smooth exterior paint of required shade, applying two or more coat of paint @ 1.67 ltr / 10 sqm and priming coat of exterior primer @ 2.20kg / 10 sqm complete all as specified and directed. |
| 48 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6), finished the surfaceseven and smoothcomplete all as specified & directed. |
| 49 | M & L for applying two coat of interior oil emulsion over a coat of wall primer incl. preparation of newly plasteredwalls etc and applying white cement based wall care putty 2mm thick in two layers of 1mm each for leveling the surface complete all as specified and directed.NOTE :- The VOC contents of the distemper shall be less than 50 gms per litre. The shade & colour shall be as approved by GE. |
| 50 | M&L for rendering 5mm thick on fair faces ofconcrete surfaces in CM (1:3) in ceilingfinished surface even and smooth without using extra cementcomplete all as specified and directed. |
| 51 | M&L for applying two coats of interior oil emulsion over a coat of wall primeron newly plastered ceilingsurfaces including preparation of surfaces complete all as specified & directed. |
| 52 | M&L for complete removal of existing treatment from old plastered surfaces of ceiling including preparation of old surfaces smooth with sand paper and including M&L for applying of distemper two coats of oil emulsion onceiling surfacescomplete all as specified & directed. |
| 53 | M&L for Preparation of old wall surfaces bybrooming down with steel wire brushes, scrapping down smoke spot moulds, moss efflorescent salts and treating oil and greasy spot,removing of nails, making good holes,cracks,loose scales,etcand applying two coat of interiar Oil emulsion distemper using roller brush on old decorated surface of walls and including washing of floors, cleaning glass, joinery,electric fittings, covering to doors, windows, etc to remove splash marks complete all as specified and directed by Engineer-in-Charge. |
| 54 | M & L for complete removal of existing treatment from walls upto any hight of floor surface by scrapping by machanical means & washing of old decorated walls etc with properly making of \"V\" shaped crackes and filling of all crackes with crackes seal of wall etcand applyingtwo coats of exterior emulsion paint over one coat of exterior primer using roller brush wall primer for levelling the surfaces ofwallsapplyingbirla / J. K. wall care white waterproof cement based putty 1mm thick in two layer the surfaces ofwalls etc and including washing of floors, cleaning glass , joinery,electric fittings ,covering to doors, windows, etc to remove splash marks complete all as specified and directed by Engineer-in-Charge. Make: Asian ACE or equivalent make as approved by GE. |
| 55 | Supply only liquid Integral waterproofing compound complete all as specified and directed. Note:- Qty of WPC used in item No. 47 and 57 shall only be measured and paid under this item |
| 56 | M&L forPCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in padding on roof surface for making proper slope on roof, surface finished fair and even without using extra cement complete all as specified & directed. |
| 57 | M & L for 10mm thick plaster in CM 1:4 with WPC @ 200ml per bag of cement will be applied over the roof slab when concrete is green after the plaster is cured the roof will be tested for water tightness by ponding with water for seven days for any seepage/leakages etc. If any seepage is observed the rectification will be carried out by pressure grouting under the pressure of 5kg/Sqcm using cement based cement grout. After the surface is repaireds the slab will be tested for water tightness again before proceeding with further treatment , complete all as specified and directed.Note : WPC will be measured and paid separately as supply only |
| 58 | M&L for PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 59 | Taking downof oldexisting roof treatment of any description, thickness (upto 30cm) from accessable/non accessable roofs including mud phushka, lime, concrete, tiles , cement plaster, paddingincluding cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250 mtr but n exc 500 mtr complete all as specified and directed.Note:- Bldg up to G+2 shall be ordered to execute the work. |
| 60 | M&L for provn of water proffing roof treatment toRCC roof with approved modified membrane of weighing not less than 3kg/sqmcomprising with following items complete all as specified and directed. |
| 61 | Item No. 60.00 Contd....(i)The surface of accsseible/non accsseible roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting.For cast iron drain outlets a groove shall be cut as specified and directed. A fillet of PCC (1:2:4) of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of dirction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded.(ii) M&L for Oil based Bitumenprimer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated.(iii) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm (iv) Laying of water proofing membrane of weight not less than 3 Kg / sqm. TheAPP modified polymeric water proofing membrane shall composed of 100 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc. (v) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqmover the membrane |
| 62 | M & L Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces in non accessible roof,complete all as specified and directedat site . |
| 63 | M&L for 100mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base of floors, etc finished the surface even and rough to receive the topping layer including demolition of existing pcc complete all as specified and directed. |
| 64 | M&L for coloured designer (anti slip with grip) tiles for parking / pathway of size 300x300mm exterior grade, heavy duty 10 mm thick laidover and including 15 mm thick cement mortar 1:6 set and jointed in floor and pointed in neat cement slurry with grey cement and pigment in floor etc andincluding dismantling of exsting floor tile removing rubbish from site complete all as specified and directed. |
| 65 | M&L Brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) including demolition of brickwork/stonemasonarycomplete all as specified |
| 66 | M&L PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in mass concrete as in foundation filling and mass concrete complete all as specified and directed. |
| 67 | M&L for multi layer POP False ceiling of any shape (Square/Circular/Semi circular etc) of design and pattern approved by Engr-in-Charge, at site incl required GI frame work and Fibre mesh/ reinforcement (Horizontal & Vertical) with Putty/POP work for even and smooth finishing surface, painting two or more coat with Premium quality plastic emulsion paint over one coat primer over smooth finish POP surface incl required provn for spot lighting/ ceiling light incl all required fixture/ material complete in all respect as specified and directed by Engr-in-Charge. |
| 68 | S&F Solid PVC frame (single rebated) of size 50 x 47 made out of 5mm wood grain printed PVC sheet reinforced with MS Square tube, supply and fixing in openingas perspecifications and drgs. |
| 69 | S&F factory made soild PVC moulded door shutter, 28mm to 30 mm thick (stiles) with wood free EPS with 2, 4 or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face including 03 Nos of SS Butt hinges 100 mm size supplying & fixing in frame at site as per specification anddrawings. |
| 70 | S& Fglazed (5.0 mm thick plain /coloured glass)aluminum door powder coated consisting of frame of 63mm x 38 mm size with shutter fixed on frame both side openable on pivotal arrangement with including necessary cutting holes in wall & floorDoor shutter consists of top rail size is 83 x 44 mm , bottom rail &lock rail size is 110 x 44 mm & style of door shutter is 83mmx 44 mmwith handles 2 Nos in each door , hinges has fitted on frame as requiredfixed with rubber gasket & aluminum beading any No of panels with aluminum handle ,locking arrangemen,floor spring and floor door stopperincl. necessary joining cleats , glazing clipsetc complete (Al. section thickness 2 mm} ) confirming to IS. Make - Jindal Aluminum / Man Industries or equivalent as approved by GE. |
| 71 | M&L for 18 mm to 20 mm thick Granite slabof any shade( table rubbed and polished ) machine cut for vertical surface of pillars, floor /shelvesin steps, jambs, pillars, window cills& cooking plateforms over and including 20 mm thick screed bed or bedding layer of CM (1:4) including pointing in white/colourcement 1:2 using marble dust with admixture of pigment to match shade of the slabslaid bedded and pointed in any mortorincluding dismantling old existing tiles of any type complete all as specified and directed |
| 72 | S&F aluminium anodised barrel tower bolts of extruded section, length of bolt in 200 mm and fixed with machine made screwscomplete all as specified and directed |
| 73 | S&F aluminium handles 150 mm size, cast type, anodised. and fixed with machine made screwscomplete all as specified and directed |
| 74 | S&F SLS-WHT-6953BIUFSM in white colour Rimless, Blind Installation Wall Hung WC with UF soft close cover, Hinges and accessories set, Size : 375x520x400 mm, incl single piece slim concealed cistern body in white finishcode: JCS-WHT-2400 with installation kit with flush control plate kubix code: JCP-BGP-352415 of colour Blush Gold PVD incl required accessories and fixture, making all connection to make it functional incl make good complete in all respect as specified and directed. Make : Jaquar or equivalent in Kohler/Hans Grohe/ Villeroy and boch |
| 75 | S&F in repair Hand Shower (Health Faucet) (Code : ALD-BGP-573PD) with 8 mm dia, 1 meter long flexible tube & wall hook with Blush Gold PVD with check nut and washers complete all as specified. Make : Jaquar Code: ALD-BGP-573PD or equivalent in Kohler/Hans Grohe/ Villeroy and boch |
| 76 | S&F in repair 15mm bore dia 2 way bib cock with wall flange code: KUP-BGP-35041PM with colour Blush Gold PVD including cover plate complete in all respect as specified and directed by Engr-in-Charge. Make :Jaquar Code: KUP-BGP-35041PM or equivalent in Kohler/Hans Grohe/ Villeroy and boch |
| 77 | S&F in repair 75 mm diameter PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified ans directed. |
| 78 | Taking down carefully copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed. |
| 79 | M&L for surface point wiring for one light point or fan point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor (stranded) 1100 volt wiring cable in & including ISI marked PVC Casing -n-caping /conduit of size not less than 20mm,ivory/white in colour with all accessories (such as tee, bend, joint cover etc) anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly, 3mm thick PVC laminated sheet (ISI marked) for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor (stranded) 1.5 sqmm cable as continuous earth lead complete all as specified and direcited. Note:-(i) Wiring cable shall be provided using colour coding such as Phase -Red, Neutral – Black, and Earth – Green or as approved by Engr-in-charge .(ii) Cutting, chassing in walls (brick or stone) shall be measured and paid separately under respectively item here-in-before. |
| 80 | All as per item No. 78 above but for one Call Bell point controlled by one push button switch. |
| 81 | All as per item No. 78 above but for 5Amp independent socket point controlled by one switch. |
| 82 | All as per item No. 78 above but for one 3 pin ,5 Amp socket point with other switch on the same board. |
| 83 | All as per item No. 78 above but for 15A socket outlet with 2.5sqmm cable. |
| 84 | M&L for concealed point wiring for one light point or fan point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor (stranded) 1100 volt wiring cable in & including ISI marked PVC Casing -n-caping /conduit of size not less than 20mm,ivory/white in colour with all accessories (such as tee, bend, joint cover etc) including modular metal flush boxes & modular white cover plate of suitable module with frame for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor (stranded) 1.5 sqmm cable as continuous earth lead complete all as specified and direcited. Note:-(i) Wiring cable shall be provided using colour coding such as Phase -Red, Neutral – Black, and Earth – Green or as approved by Engr-in-charge .(ii) Cutting, chassing in walls (brick or stone) shall be measured and paid separately under respective item here-in-before. |
| 85 | All as per item No. 83 above for one Call Bell point controlled by one push button switch. |
| 86 | All as per item No. 83 above for 5Amp independent socket point controlled by one switch. |
| 87 | All as per item No. 83 above for one 3 pin ,5 Amp socket point with other switch on the same board. |
| 88 | All as per item No. 83 above but for 15A socket outlet with 2.5sqmm cable. |
| 89 | S&F Modular switch, one way, 6 Amp 230 volts, 1 module complete all as specified and directed . |
| 90 | S&F socket Modular 6 Amp-2/3 pin combined 2 module complete all as specified and directed . |
| 91 | S&F switch Modular, one way,6/16 Amp ,1 module 230 Volt complete all as specified and directed . |
| 92 | S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt complete all as specified and directed . |
| 93 | S&F modular fan step regulator 60-80W2 module complete all as specified and directed. |
| 94 | S&F modular bell push 6A ,1 module complete all as specified and directed. |
| 95 | S&F switch piano type flush, single pole, one way 5 A 230 V complete all as specified and directed. |
| 96 | S&F socket outlet, 5 pin, 5 Amp, flush type, 230 V complete all as specified and directed. |
| 97 | S&F switch piano type flush, single pole, one way 15 A 230 V complete all as specified and directed. |
| 98 | S&Fsocket outlet2 in 1,6 pin, 5/15 A, flush piano type240 V complete all as specified and directed. |
| 99 | S&F ceiling rose, surface backlite,three terminal complete all as specified and directed. |
| 100 | S&F lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed. |
| 101 | S&F bell ding dong 230 V, single phase complete all as specified and directed. |
| 102 | S&F electronic double space rotary 5 speed type regulator 120-280 V complete all as specified and directed. |
| 103 | S&F bell push flush type one way 5Amp 240 Volt complete all as specified and directed. |
| 104 | M&L for surface conduitsub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size6 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size . ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wireand colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green etc complete, including taking down old unserviceable sub main wiring with casing-caping/conduit complete all as specified and as directed.Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core of size 6.00 sqmm for main current and one run of single core of size6.00 sqmm for earth continuity conductor & one run of PVC casing-caping/conduit shall be measured as one unit length. |
| 105 | S&F MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristicscomplete all as specified and directed. |
| 106 | S&F MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics complete all as specified and directed. |
| 107 | S&F sheet metal enclosureDB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 100-160 Amps rated bus bar including taking down of existing DB complete all as specified and directed. |
| 108 | S&F LED Bulk head 13/10 watt designed for modern homes available in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed. |
| 109 | S&F TL fitting 20/18watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directed. |
| 110 | S&F box type LED optic fitting10/9 Watt2 feet box type complete all as specified and directed. |
| 111 | S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250MM complete all as specified and directed.Note:- Old unserviceable fans shall be deposited in MES store yard at AGE E/M Saugor and cost of the same deemed to be included in quoted unit rate. |
| 112 | S&F in repairexhaust fan,Metal body AC single Phase. 230V of size 300 mm sweepwith, blades, and frame and louvers complete all as specified and directed.Note:- Old unserviceable fans shall be deposited in MES store yard at AGE E/M Saugor and cost of the same deemed to be included in quoted unit rate. |
| 113 | S & F in repair laminated super hylem sheet, white,3mm thick of size 8\" x 5\" including making provision for switches, sockets etc complete all as specified and directed. |
| 114 | All as per item No. 112 above but sheet of size 5\" x 5\" |
| 115 | All as per item No. 112 above but sheet of size 8\" x 10\" |
| 116 | All as per item No. 112 above but sheet of size 8\" x 12\" |
| 117 | All as per item No. 112 above but sheet of size 9\" x 11\" |
| 118 | S&F in repair LED bulb 9/10 watt suitable for angle/batten holder fitting complete all as specified and directed. |
| 119 | Supply and laying/fixing PVC insulated and unsheathed single core multi stranded copper conductor 1.50 Sqmm (Nominal Area) drawn in existing conduit / batten / surfaceetc, including taking out defective wire/cable complete all as specified and directed. |
| 120 | All as per item No. 118 above but cable of size 2.5sqmm |
| 121 | M&L for PVC conduit of size 20mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiringas required at site including taking down existing PVC conduit complete all as specified and directed. |
| 122 | M&L for PVC casing caping of size 1\" x 1/2\" including fixing on wall/ceiling with clamp/saddles for wiringas required at site including taking down existing PVC casing-caping complete all as specified and directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail