Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Schedule-A (B/R & E/M Works) |
| 2 | Dismantling of existing brick tiles in single layers on roof including grass, trees treating with chemical and cleaning the surface and removal out side of MoD land complete all as specified and as directed.Note :Taking down earthng strips and solar panel wires from roof and re-fixing on the same position after APP laying is deemed to be inclusive of rate quoted by the contractor. |
| 3 | Demolition of existing mud in roofs of any thickness including plastering and leeping (whether full thickness removed or only a part thereof)and removing of mud out side of MoD land, (up to 4th storey) all as specified anddirection by Engr in charge. |
| 4 | M&L for Cutting out cracks \"V\" section on existing roofs or terrace cleaning out and filling solidly with a hot mixture bitumen and clean dry sand 1:1 by weight complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L providing cement concrete in roof or mud stops using type B-1, 1:2:4 (20mm graded aggregate)rounded or chamfered on edges or making slop on roof complete (up to 4th Storey) all as specified and as directed |
| 6 | M&L for 10 mm thick cement plasteringin CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, as per manufacturer instructionfinished even and smooth without using extra cement complete(up to 4th storey) all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately. |
| 7 | Supply only liquidwater proofing compound |
| 8 | M&L water proofing treatment on roof and sunken portion of floor andvertical surface consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 Kg/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified.(c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/ sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed. |
| 9 | M&L for applyingone coat Bitumenwater proofing aluminium heat resistance painton the roof as per manufacture instructions complete all as specified and directed by Engr-in-Charge. Make : PLASCON/PLASCON or equivalent. |
| 10 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete in all respect as specified and as directed by Engr-in-Charge. |
| 11 | Providing & fixing false ceiling With semi perforated 12mm thick micro tegular edged at all heights with GRG ( Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture,design and patters having moisture content lessthan 2%. Humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987,Noncombustible as per BS 476 (part4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15x32mm of length 3000mm,cross-T of size 15x32 of length 1200mm and secondary intermediate cross-T of size 15x32mm of length 600mm to from grid module of size 600x600mm, suspended from ceiling using galvanized mild steel items (galvenizing @ 80 grams per sqm)i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm lenght and L shape level adjuster of size 85x25x2mm Galvenised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work complete in all respect as per specifications, drawing and as per directions of the Engineer-in-charge. |
| 12 | Taking dwon chowkats or frames with shutters (without taking off shutters fromk the frames) not exc 1.5 sqm each, complete in all respect as specified and directed. |
| 13 | Taking down chowkat or frame with shutter (without taking out shutter from the frame) exc 1.50 Sqm but not exc 4.00 sqm, each as doors, windows & ventilators etc. and removal from site, complete all as specified and directed by Engr-in-charge. |
| 14 | S&F anodised aluminium glazed wall partition with anodised aluminium frame of section83x44x2mm including with all necessary suitable screw, rubber packing, aluminium snap beading complete all as specified and directed. ( Sizes of each panel of partition - approx 0.9mx0.60m) |
| 15 | M&L for 5 mm thick aluminium composite sheet, exterior grade fixed betdween aluminium section with and including snap fitting aluminium clips of polyster powder coated alongwithrubber fgasket, complete all as specified and directed by Engr-in-charge |
| 16 | S&F in repair 5.5 mm thick sheet glass, ordinary quality, in square exc 0.5 sqm each pane fixed to aluminium frmae with rubber gasket or fixed with glass puttty as required etc complete all as specified and as directed |
| 17 | S&F aluminium colour powder coated door Frame and shutter single or double leaf glazed/pre laminated particle board interior panels fabricated including aluminium powder coated beading rubber Gasket and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following:- (a) Door frame section 101.60x44.45x1.93 mm fixed as per spd (b) Door Shutter Vertical Style of Size 85x44.45x2 mm as per spd. (c) Door Shutter Top style section 95.25x44.45x2.00 mm as per spd.(d) Aluminium coloured powder coated middle lock rail/bottom rail section 150x44.45x1.93mm cat No.20002.(e) Aluminium coloured powder coated Tower Bolt 02 Nos in each shutter 200 mm long as spd. (f) Aluminium coloured powder coated handle 02 Nos in each shutter 150 mm long as per spd.(g) Door Floor spring ISI Marked Make-Sandhu, Amar or equivalent.(h) Six lever mortice lock brass on in each door.(j) 12 mm thick partical board (pre laminated both face) exterior grade ISI Marked(k) Tinted glass/Plain glass(Colour) 5mm thick. |
| 18 | S&F aluminium colouredpower coated (shade or tint as directed by GE) Side Hung window/ventilator frame and Shutter with section as per TD-109/2012 sheet (1/4 to 4/4) comprising the following:-(a) Al coloured powder coated window frame section 101.60x44.45x1.93 mm fixed as per spd(b) Aluminium colouredpower coated double shutter (Glass and Wire Mesh shutter) 44x44x1.50mm top/bottom/sides style. (c) Aluminium colouredpower coated butt hinges 8 Nos in each window 100 mm sizes as per spd. (d) Aluminium colouredpower coated tower bolt 3 Nos in each window 150 mm long as per spd.(e) Aluminium colouredpower coated handle 2 Nos in each window 100 mm long as per spd.(f) Tinted/coloured glass 5 mm thick fixed to window with rubber gasket & Al Powder coated beading.(g) Aluminium colouredpower coated grill make deco grill DG-104 fixed with \"H\" Section.Note : If groundrequirement for sliding window/AC windowcontractor should provide as per direction of Engineer-in-Charge without any price adjustment. |
| 19 | S&F vanishing roller/ vertical blinds as required for windows/ door/ ventilator of any colour and pattern with exc 1.5 sqm but not exc 4.00 sqm each, as approved by Engr-in-Charge including connected items i.e. rod, hooks etc with complete fittings, complete all as specified and directed by Engr-in-charge. |
| 20 | S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. |
| 21 | S&F stainlessSteel Wire Cloth, 0.36mm nominal dia of Wire and average width of aperture 1.4 mm and fixed with Tinned Tacks of Mild Steel Wire Stapes, etc, complete all as specified and as directed. |
| 22 | Hacking out old broken glass (any th size, quality or description) from wooden or steel frames glazed with putty or fixed with wooden beads, complete all as specified and as directed by Engineer- in- Charge. |
| 23 | S&F 04 mm thick Sheet Glass, Ordinary, Glazing as in Window Frames fixed with Wooden oil putty/rubber beads, not exc. 0.50 Sqm in Each Pane and fixed in repairs, complete all as specified and as directed. |
| 24 | S&F Solid PVC Wall Liningconsisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement & fixing at site on PVC frame as per specification & drawing complete all as specified and as directed by Engineer- in- Charge. |
| 25 | S&F 5 mm thick PVC sheet fillet of wdth 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing, complete all as specified and directed by Engr-in-Charge. |
| 26 | Demolition of brick work or stone/ boulders masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etac but excluding ashlars facings, dressed stone work and precast concrete articles, complete in all respect as specified and directed by Engineer-in-Charge. |
| 27 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-charge. |
| 28 | Taking down Cement Plaster from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. |
| 29 | M&L for 15 mm thick Rendering in CM 1:4 finished even and smooth without using extra cement complete all as specified and diirected by EiC. |
| 30 | M&L 15mm thick plastering on brick/stone/concrete surafces of wall in cement mortar (1:6) finished even and smooth without using extra cement complete in all respect as specifified and directed. |
| 31 | M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surface as in ceiling finished even and smooth w/o using extra complete all as specified and directed by Engr-in-charge. |
| 32 | M&L for applying two coat of exterior Acrylic emulsion paint (100% acrylic) of approved colour and shade over a coat of primer and over 1 to 2 mm thick birla putty punning including preparation of new plastered surface complete all as specified and as directed by Engineer-in-charge. (Note:-including necessary scaffolding upto 4th Storey) |
| 33 | M&L for preparation of newly undecorated plastered surface of wall and applying two coats of oil bound distemper (OBD) and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 3 mm thick (in two layers), wall care putty, complete in all respect as specified and directed. |
| 34 | M&L for preparation of newly plastered surfaces of Ceiling, and applying two coat of Oil bound distemper white or colour, over one coat of primer including wall care putty upto 2 mm thick as required (multipurpose mixer shall be used for uniform adn proper mixing of putty)by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-charge. |
| 35 | M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand mixed with Liquid WPC) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 white cement: 1/2 coarse sand: 2 stone chipping 6mm t0 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately). |
| 36 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using Aluminium Channel, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as specified and directed by Engineer-in-charge. |
| 37 | M&L for comlpete removal of existing treatment from old decorated plastered surfaces of walls by vaccum based sanding machine complete all as specified, removal of nails etc and filling cracks/ hole with putty, applying wall care putty upto 1 mm thick as required (multipurpose mixer shall be used for uniform adn proper mixing of putty) and applying two coats of oil bound distemper white or coloured over a coat of approved primer by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-charge. |
| 38 | M&L for complete removalof existingtreatment from old decorated plasterred surfaces of walls by vaccum based sanding machine complete all as specified, removal of nails etc and filling cracks/ hole with applying wall care putty upto 1 mm thick as required (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats of exterior emulsion anti fungal paint 100% acrilic smooth exterior paint @ 1.67 Ltr/ 10 Sqm, colour as approved by GE, over & including a coat of approved primer by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for comlpete removal of existing treatment from old decorated plastered surfaces on ceilings by vaccum based sanding machine complete all as specified, removal of nails etc and filling cracks/ hole with putty and applying two coats of oil bound distemper white or coloured over a coat of approved primer by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-charge. (Note :- Rate included for four storey building including scaffolding and all safety measures) |
| 40 | Dismantling floor, stone, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge. |
| 41 | Demolition of Cement Concrete (un-reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing the same from Site(s), complete all as specified and as directed. |
| 42 | M&L for 50 mm thick PCC 1:2:4Type B-0 (12.5 mm Graded Stone Aggregate) as in sub flooretc., including rough top surface to receive floor finish complete all as specified and as directed. |
| 43 | M&L for 10 mm thick Vitrified light shade Coloured tiles, square/ rectangular double polished, area of each tile n.exc. 0.36 sqm,in floor including 15 mm thick screed bed in CM 1:6 etc.,set and jointed in neat cement slurryand pointed in white with pigment to matchfor laying floor finishes all as specified and as directed by Engr-in-Charge. |
| 44 | M&L for 10 mm thick vitrified light shade coloured tiles (square/ rectangular) double polished, area of each tile not exc 0.36 sqm set and jointed in neat cement slurry and pointed in coloured cement on vertical surface such as Skirting/ dado etc over and including 10mm thick backing coat in CM 1:4, complete all as specified and as directed by Engr-in-charge. |
| 45 | M&L for gunntling to RCC works in column, beams, slabs, chajja, ceiling, facia landing , balconies and similar work etc by removing/dismantling of RCC (loose concrete) including plaster and cutting of steel bar including cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fisng with sufficient fastners/concrete nails/welding at regular intervals welded steel wire mesh 50mmx50mm with 4mm dia steel wire as faces/drops and applying epoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikaa. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm with varying thickness from 25mm to 100mm as per requirement at site gunniting in cement mortar (1:2) (one pat of cement and two part of ghaghar sand) and plastering in cm 1:4 to a uniform surface, wherever required at any height, location and positon complete all as specified and directed.Note: (i) After placing the additional reinforcement all conrete surface shall be thorughly scrubbing with. (ii) Additional reinforced TMT bars were incorporated in work however min 20mm cement plaster in 1:4 and necessary concrete wks related to gunniting to be included in quoted rate. (iii) Gunniting at Ground floor to 4th storey (iv) Anti corrosive protective coating for reinforced bars. (v) Work to be carried out as in patches as directed by Engineer-in-Charge. (vi) Rate for steel scaffolding and formwork wherever required and as directed to be included in quoted rate.(vii) All demolished material removed from MoD land completelyto any location as per NGT Norms.(viii) The work will be executed in different buildings and at scattered locations. |
| 46 | Demolition of Stone slabs and tiles laid dry of any description or thickness in floors, aprons etc |
| 47 | M&L Machine cut kota stone slab flooring 20-25mm thick over 15 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over reoughfening of floor surface complete all as specified and directed by Engr-in-Charge. |
| 48 | M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick rendering in CM 1 :4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over reoughfening of vertical surface complete all as specified and directed by Engr-in-Charge. |
| 49 | Excavating in trenches, n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, shafts, manholes, etc. n. exc. 10 sq m on plan and getting out in soft/loose soil complete in all respect as specifified and directed. |
| 50 | Returning filling with excavated soil obtained from excavation in layers n exc 25cm including spreading levelling watering and well ramming complete alla s specified and as directed. |
| 51 | Removal of excavated soil/debris/malwa to a distanceexc 5 KM and not exc 10.00 KM incl loading, unloading and stacking at per NGT norms. |
| 52 | Providing and layingcement concrete in foundations, filling and mass concrete using type D-2, 1:4:8 (using 40mm nominal size crushed and graded stone aggregate) complete in all respect as specifified and directed. |
| 53 | M & L for Broken stone orboulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete in all respect as specified and directed |
| 54 | M&L for 100 mm thick PCC (1:3:6) type C2 (using 40mm crushed and graded stone aggregate)as in flooringfinished fair and even surafce complete in all respect as specified and directed. |
| 55 | M&L for 40 mm thick PCC (1:2:4) type B0 (using 12.5mm crushed and graded stone aggregate)as in flooringfinished even and smooth using extra cment complete in all respect as specified and directed. |
| 56 | S & F Plastic dividing strips, 1.5mm thick of size 38mm complete in all respect as specified and directed. |
| 57 | M&L for Chequered Cement Concrete Tiles 30 cm x 30 Cm x 25 mm thick pre-printed coloured, Set and Jointed in Neat Cement Slurry with Grey Cement and Pigment over and including 15mm thick Screed Bed in CM (1:4) as in Path, complete all as specified and directed by Engr-in-Charge. |
| 58 | M & L 75 mm thick PCC (1:3:6) type C-2 using 40 mm nominal size crushed and graded stone aggregate laid as in base concrete and plinth protection finished the surface even and fair without using extra cement complete in all respect as specified and directed. |
| 59 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality \"A\") complete all as specified and directed. |
| 60 | S&F plate girder or single stanchions, built up of one beam or channel section with flange plates, caps bases, splices, agnle brackets cleats and other connection confirming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed. |
| 61 | S & F plates (plain or chequered) channels, square cutor notched (ordinary and countersunk) forming holes, without any attachmentwith riveted, bolted or welded attachment using Fe-410W (Grade E-250 quality \"A\") complete in all respect as specified and directed. |
| 62 | S&F16 to 20mm dia of neck of MS Bolt screw bolts (purpose made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed. |
| 63 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.Note-The measurement shall be carried out as in plain |
| 64 | S&F in repairmild steel works Fe-290, Gde -165 as in framed works such as door frame using box section/ grills/ guard bar/ plates and railing with ends of bars shoulders and or riveted or forged into spiked complete. |
| 65 | M&L for applying two coats synthetic enamel paint over a coat of red oxide/zinc chrome primer including preparation of new steel/iron surfaces exc 10cm in width or girth all as specified and as directed by Engineer-in-charge. |
| 66 | Demolition of Cement Concrete reinforcement roof, floor (Other than ground floors), beams , staircase, landing, chajjas and similar suspended works etc. |
| 67 | M&L for RCC (Nominal mix) type B1, 1:1 1/2:3 (20 mm graded aggregated) asin slab supported walls, beams and columns in floors, roof, landing, balconies,chajjas, conopies, cooping deck slab and selves and the like. |
| 68 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping). |
| 69 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engr-in-Charge. |
| 70 | S&F in repair, 2000 ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layered, ISI marked, hoisted and fixed in position including tank neeples of required size and 25 mm bore dia of pipe ball brass valve high pressure with plolythelene float and flynutcomplete all as specified in SSR Part I complete all as specified and as directed. |
| 71 | S&F Galvanised Steel Water Tubing 20mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed to concealed or onWalls, Ceiling or laid in Floors/walls including Taking down old GI tubing, complete all as specified and as directed. |
| 72 | Supply and installation in wall split units indoor/out door complete with cordless with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR with mounting accessories for out door indoor units |
| 73 | Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 volt with output voltage at 230 Volt with accuracy of +2.5% and of capacity 5 KVA. Make :- Blue bird/V Guard or equivalent. |
| 74 | S&F nylon braided PVC pipe of size 20 mm dia outer suitable for split AC drain including fixing accessories such as claps screws rawl plugs etc complete all as specified and directed. |
| 75 | S& F prefabricated AC stand suitable for wall mounting of floor mounting made with mild painted with syntheic enameled paint with anti vibration rubber pads including grouting in wall applicable for wall mounting type complete all as pecified. |
| 76 | M&L for suction and discharged copper tubing of size1/2 inch and 1/4 inch dia 0.5 mm thickness from indoor unit to outdoor unit of split type AC upto 2TR capacity including soldering and braizing complete all specified and directed.Note:- Suction and discharged copper tubing together will be measured as one unit of Runing Meter. |
| 77 | All as per item No- above but copper tubing size 5/8 inch and 3/8 inch dia and 0.5 mm thickness. |
| 78 | S&F sheet metal enclosure , 32A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one SPN MCB 20 Amp fixed properly on in concealed position all as directed by Engineer-in-Charge.Make:- Legrand/Schenider/HPL |
| 79 | M&L sub main wiring with two single core PVC-FRLS insulated unsheathed stranded copper conductor cable of size 4 sqmm drawn in Steel enamelled conduitsize 20 mm dia with 2.5 Sqmm PVC-FRLS insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl.Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length |
| 80 | Taking down copper/aluminium point wiring (light points) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed |
| 81 | Taking down copper/aluminium submain wiring complete, including conduits of any kind, and removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed |
| 82 | Taking down main switches, distribution boards etc of any type and capacity along with the existing boards including MCBs/MCCBs and removing the same from site and making good the disturbed surfaces/portion of walls etc. all as directed. |
| 83 | Taking down fluorescent tube light fittingsof any wattage or size and deposit to MES store or for taking credit complete all as specified. |
| 84 | M & L for concealedpoint wiring for light pointwith 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories(PVC Casing and caping to be done wherever wiring to be run on ceilings and concrete surfaces including one run of 1.5 sqmm FRLS muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly,including sunksheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface ,including laminated hylum sheet cover, ISI marked of Make\" Hylem\" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code in IE rule.Rate includes chase cutting for concealed wiring Make of Cable : Polycab/ L&T/ Havells |
| 85 | All as per item No. 2 here-in-before but for one Ceiling fan/wall fan Point controlled by one way switches, with cables 1.5 sqmm complete all as specified and directed. |
| 86 | All as per item No 05 above but for 5 Amps 5 Pinsocket outleton the same board |
| 87 | All as per item No 05 above but one 5 pin, 5 Amp socket outleton independent board not below the switchboard of thelight point in the same vertical plane. |
| 88 | All as per item No 05 above but one 5 pin, 15 Amp socket outleton independent board for power point with 2.5 sqmm size copper wire |
| 89 | S& F ceiling rose, 2 to 3 terminals complete all as specified and as directed . |
| 90 | S&FModular switch, one way 6 Amps , 1 module as specified. |
| 91 | S&F Modular Socket , 6 A-2/3 Pin combined 2 moduleall as specified and directed. |
| 92 | S&F twin socket modular type heavyduty out let 6 pin 6/16 Amps 2 module, |
| 93 | S&Fswitch Modular type 16 Amps , single pole one way 240 volts one module as specified. |
| 94 | S&FModular Fan stepRegulator Bell ,120 W-2 module as specified. |
| 95 | M&L for metal flush box for fixing of switches for 3 module |
| 96 | M&L for metal flush box for fixing of switches for 4 module |
| 97 | M&L for metal flush box for fixing of switches for 6/8 module |
| 98 | Supply & fix Modular White cover plate with frame for 3 module |
| 99 | Supply & fix Modular White cover plate with frame for 4 module |
| 100 | Supply & fix Modular White cover plate with frame for 6/8 module |
| 101 | S&FModular type blank plate , 1 module for switch bd/DB box blank space allas specified. |
| 102 | Supply & fix sheet metal enclosurefor220 volts 20 Amps with a three pin and earth plug top with socket and one single pole MCB20 amps complete as well as specified and directed. |
| 103 | Taking down of serviceable ceiling fans/wall mounted fan and refixing the same on same position including painting of any type of fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etccomplete all as specified. |
| 104 | S&F Sheet metal enclosureDouble doorSPN 240 Volts 8 way DB with 200 Amps rated busbar complete all as specified and directed. |
| 105 | S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar 6 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43with MCB as incommer and MCB SP/TP in outgoing complete all as specified and directed by Engr-in-charge..Make- Legrand/ Seimens/ Schinder. |
| 106 | S&FMCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .Make : Make: Legrand /Siemens/Schneider. |
| 107 | S&F MCB SPN 32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .Make: Legrand /Siemens/Schneider. |
| 108 | S & FMCCB TPN 100A Amps 415V 10 KA \"C\" curve including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge. .Make- Legrand/ Seimens/ Schinder. |
| 109 | Material and labour for sub-main wiring with2 runs of10 sqmm FRLS PVC insulated, multi-stranded, copper cable, 1100 V grade, along with one run of 10.0 sqmm copper cable for earth continuity wire connected to common earth dolly (Colour code to be followed) drawn through concealed 20 mm dia, medium grade,PVC conduit, including accessories complete all as specified and directed .Make of Cable : Polycab/ L&T/ Havells |
| 110 | Ditto-above but three run of 6 sq mm complete all as specifed and as directed. |
| 111 | Ditto-above but three run of 4 sq mm complete all as specifed and as directed. |
| 112 | S&F in replacement of 4 ft 18/20 watt Decorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energycomplete all as specified and by Engr-in-charge. |
| 113 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roofceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 114 | Supply and Fix, wall fan,rating 240 V, 50 Hz, Single Phase, 300 mm sweep with all accessories, all as per Model “D’zire HS” of Make ‘Havells’ or equivalent Model of Make ‘Usha’/ ’Crompton Greaves’/ ’Almonard’, and connecting up from socket outlet to fan complete all as specified and directed. |
| 115 | Note:- The amount of Rs 14313/- against Schedule of Crediton Srl Page149shall be deducted from the total amount quoted against Sch \"A\" |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail