| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) & disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification & direction of E/I |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 3 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 4 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 6 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 7 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 cement : 2 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 11 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for (Foundations, footings, bases of columns, etc. for mass concrete) |
| 16 | Suspended floors, roofs, landings, balconies and access platform |
| 17 | Shelves (Cast in situ) |
| 18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 21 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 22 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 23 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshol of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Fixing with adjustable lugs with split end tail to each jamb |
| 24 | ProvidingandfixingfactorymadeP.V.C.doorframeofsize50x47mmwithawallthicknessof5mm,madeoutofextruded5mmrigidPVCfoamsheet,mitredatcornersandjoinedwith2Nosof150mmlongbracketsof15x15mmM.S.squaretube,theverticaldoorframeprofilestobereinforcedwith19x19mmM.S.squaretubeof19gauge,EPDMrubbergasketweathersealtobeprovidedthroughouttheframe.ThedoorframetobefixedtothewallusingM.S.screwsof65/100mmsize,completeaspermanufacturer\"s specification and direction of Engineer- in-Charge. |
| 25 | ProvidingandfixingfactorymadepanelPVCdoorshutterconsistingofframemadeoutofM.S.tubesof19gaugethicknessandsizeof19mmx19mmforstylesand15x15mmfortop&bottomrails.M.S.frameshallhaveacoatofsteelprimersofapprovedmakeandmanufacture.M.S.framecoveredwith5mmthickheatmouldedPVC\"C\"channelofsize30mmthickness,70mmwidthoutofwhich50mmshallbeflatand20mmshallbetaperedin45degreeangleonbothsideformingstylesand5mmthick,95mmwidePVCsheetoutofwhich75mmshallbeflatand20mmshallbetaperedin45degreeontheinnersidetoformtopandbottomrailand115mmwidePVCsheetoutofwhich75mmshallbeflatand20mmshallbetaperedonbothsidestoformlockrail.Top,bottomandlockrailsshallbeprovidedbothsideofthepanel.10mm(5mmx2)thick,20mmwidecrossPVCsheetbeprovidedasgapinsertfortoprail&bottomrail,panelingof5mmthickbothsidePVCsheettobefittedintheM.S.framewelded/sealedtothestyles&railswith7mm(5mm+2mm)thickx15mmwidePVCsheetbeadingoninnerside,andjoinedtogetherwithsolventcementadhesive.Anadditional5mmthickPVCstripof20mmwidthistobestuckontheinteriorsideofthe\"C\"ChannelusingPVCsolventadhesiveetc.completeasperdirection of Engineer-in-charge, manufacturer\"s specification & drawing |
| 26 | providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.8MM |
| 27 | 12MM TO 20MM |
| 28 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 29 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 30 | Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 31 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 32 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 33 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 34 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 35 | Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 36 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 37 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 38 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 39 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible |
| 40 | Covering of treated surface with PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm |
| 41 | Providing and filling of 6 mm thickGroove between 50 mm PCC Panels with 6 mm thick 25 mm deep thermocol strip and filling the rest 25 mm with Polysulphide Sealant (Poring Grade)as per |
| 42 | Providing and laying Vitrified tiles in flooring different sizes(thickness to be specified by the manufacturer)with water absorption less than0.08%and conforming to IS:15622,of approved brand & manufacturer,in all colours and shade,laid on 20mm thick cement mortar1:4(1cement:4coarse sand)joint in with grey cement [email protected]/sqm including grouting the joints with white cement and matching pigment set.The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier etc.. |
| 43 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:.3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 44 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110mm dia Single socketed pipes.75mm |
| 45 | 110mm |
| 46 | Providing and fixing unplusticised PVC pipes clips of approved design to unplustised pvc rain water pipes by means 50x50x50mm hard wood plug,screwed etc all complete as per building specification and direction of E/I.75MM |
| 47 | 110MM |
| 48 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots andmaking provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) - Polyester powder coatedaluminium(minimum thickness of polyester powdercoating 50 micron) |
| 49 | Providing and fixing glazing in aluminium door,window,ventilator shutters and partitions etc.with EPDM rubber/neoprenega sket etc.complete asper the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight notless than 10kg/sqm) |
| 50 | Stainless steel wire guage (Grade-304) aperture 1.4 mm and0.50mm dia wire |
| 51 | Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone work by providing weather silicon sealan to verbackerrod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 52 | Providing and applying 1mm thick white cement based putty-do-do all complete job as per direction of E/I. |
| 53 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 54 | Providing and fixing stone slab with table rubbed,edges rounded and polished,ofsize75x50cm deep and1.8cm thick,fixed in urinal partitions cutting achase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4(1cement:2coarsesand:4graded stone aggregate 6mm nominal size)as per direction of Engineer-in-charge and finished smooth.-Granite Stone of approved shade |
| 55 | Special type C.P.Bathroom Fitting for V.I.P.Buildings (JAL,Jaquar, Mark or Equivalent)Pillar cock (Long neck) |
| 56 | Bib cock (2 Way) |
| 57 | Angular Stop Cock (Long Thread) ISi Marked) |
| 58 | Pressure Adjustable Shower with revolving joint (HealthFaçade) |
| 59 | Towel Rail 24\" |
| 60 | soap dish |
| 61 | Providing and fixing Gun metal full way valve of approved quality, all complete as per specification and direction of E/I.(a) 15mm dia and weight not less than 300gms. |
| 62 | (b) 20mm dia and weight not less than 400gms. |
| 63 | (d) 32mm dia and weight not less than 700gms. |
| 64 | (f) 50mm dia and weight not less than 1.5kg. |
| 65 | upplying and fixing G.I. Fitting of approved make all complete as per specification and direction of E/I.1)Elbow15mm |
| 66 | 3)Reducing Socket20mm |
| 67 | 4)Nipple15mm |
| 68 | 5)Plugs5)15mm |
| 69 | Cutting chhajja or corince for laying G.I.pipe and restoring the same with R.C.C.(1:2:4)brick work in cement mortor(1:4) as per specification and direction of E/I. |
| 70 | Making holes in walls for laying G.I. pipe and restoring thesame after pipe laying as per specification and direction ofE/I.( b)250 mm thick wall |
| 71 | Supplying, fitting and fixing the following items completewith all materials as per specification and direction of E/I.(b)Mirrors of 6mm thick glass bevelled edge mirror includingC.P. brass revolving fittings 3mm ply wood board and C.P.hinges to fix with mirror(i) 600mm x 450mm size |
| 72 | Earth work in excavation for laying of different types andsizes of R.C.C. spun pipes with disposal of exacavted earthwithin initial lead and sizes of R.C.C. spun pipes with disposalof excavated earth within initial lead and lift as per specification and direction ofE/I. 10x 0.500 x 0.600 |
| 73 | Labour for alying, fitting and fixing NP2 R.C.C. spun pipe withcolars in lines, level and grade and providing approvedjointing materials and joints properly filled to make themleakproof including providing sight rails, bonning rod, nightguard, Red light and barrier etc. all complet as perspecification and direction of E/I.150mm |
| 74 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep,600 x 450mm internal dimension having 250mm wallthickness in cement mortar (1:6) including 12mm cementplaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 75 | Supplying and fixing NP2 Hume pipe etc. (150mm dia) |
| 76 | Providing and fixing on wall face unplasticised Rigid PVC rainwater pipes conforming to IS : 13592 Type A, includingjointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75mm |
| 77 | 110mm |
| 78 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75mm coupler |
| 79 | 110mm coupler |
| 80 | Single pushfit coupler |
| 81 | 110mm |
| 82 | 75mm Single tee with door |
| 83 | 110mm Single tee with door |
| 84 | 75mm Single tee without door |
| 85 | 110mm Single tee without door |
| 86 | 75mm Bend 87.5° |
| 87 | 110mm Bend 87.5° |
| 88 | 75mm shoe(plain) |
| 89 | 110mm shoe(plain) |
| 90 | S/F/F viterous white glazed earthen ware I.W.S of parry Hindustan or any other I.S.S approved make with 100 mm H.C.I \"P\" trap 15 liters C.I or C Pull ........... With 10 lit low level P.V.C CistemDo.....do.....do....... All complete as per specification and direction of E/l. 580mm long - With 10.0 liter low level PVC cistern |
| 91 | Supplying fitting and fixing 40mm high vitreous glazed earthen E.W.C with \"P\" trap of parry/ Hindustan or any other approved I.S.S make including supplying and fixing 15 liters C.L mosquito proof low down flush-ing cistern of approved make with complete fittings with C.l. handle and R.S or bracket with teles-copic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms 15mm P.V.C alkathene pipe 45 CM long with brass coupling at both ends and white . black plastic solid state seal and lead of commander/cuckoo or other I.S,S make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete job as per specification and direction of E/l with PVC sistern. |
| 92 | Supplying, fitting and fixing flat back or angular, lipped frontvitreous white glazed earthen ware urinal of Hindustan\"Parry\" or any other approved I.S.S. Make with 5 literscapacity C.I. Automatic fulsing cistern of reliance for anyother I.S.S. approved make with all fittings with C.I. or R.S.bracket, standard size G.I. flush pipe with fitting clamps,15mm C.I. body brass spindle stop cock of approved qualityweight not less than 400grams, 15mm P.V.C./Alkthene pipe450mm longwith brass coupling at both ends and doingplumber joints including painting of exposed part with twocoats of approved paint over a priming coat of red oxide,cutting wall and floor, making good the same etc. allcomplete as per specification and direction of E/I.(a) Flatback or standing corner (600mmX350mm) |
| 93 | Providing and fixing wash basin with C.I. brackets, 15 mm diaCP Brass single hole basin mixer of approved quality andmake, including painting of fittings and brackets, cutting andmaking good the walls wherever required:- (a) WhiteVitreous China Wash basin size 550x400 mm with a 15 mmCP Brass single hole basin mixer |
| 94 | Providing and fixing white vitreous china pedestal for washbasin completely recessed at the back for the reception ofpipes and fittings. |
| 95 | Providing and fixing P.V.C. waste pipe for sink or wash basinincluding P.V.C. waste fittings complete. Flexible Pipe - 40 mm |
| 96 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank, IS : 12701 marked, withcover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes butwithout fittings and the base support for tank. |
| 97 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, includingfixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction ofEngineer in Charge.Internal Work - Exposed on Wall32mm dia pipes |
| 98 | 50mm dia pipes |
| 99 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, i/c fixingthe pipe with clamps at 1.00 m spacing. This includes jointingof pipes & fittings with one step CPVC solvent cement andthe cost of cutting chases and making good the sameincluding testing of joints complete as per direction ofEngineer in Charge.Concealed Work15mm nominal dia pipes |
| 100 | 20mm nominal dia pipes |
| 101 | Providing and fixing PTMT grating of approved quality andcolour.C.P. Gratings,Circular type - 125 mm dia |
| 102 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 103 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I. |
| 104 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 105 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 106 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 107 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40mm nominal size) |
| 108 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).Lintel,Slab |
| 109 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended Floors, roofs, landings, balconies and access platform slab Slab side shuttering. |
| 110 | Lintels, beams, Plinth beams, girders, bressumers and cantilevers Lintel |
| 111 | Providing Toe steel reinforcement of following dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel)8mm dia |
| 112 | 10mm dia |
| 113 | 12mm dia |
| 114 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I |
| 115 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 116 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I |
| 117 | \"Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group B\" |
| 118 | Wiring for twin control light point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, mdoular plate, suitable size G.I. box etc. as required |
| 119 | Wiring for light/power plug with 2 x 4 sq.mm FRPVC insulated copper conductor single core cable insurface/recessed PVC conduit along with 1 No. sq.mm FRPVC insulated copper conductor single core cable for loop earthing as required |
| 120 | Wiring for circuit/submain wsizes wiring along with earth wire with the following sizes PVC insulated coper conductor, single core cable for look earthing as required. 2x1.5 sq mm+1x1.5 sq. mm earth wire |
| 121 | 2x2.5 sq mm+1x2.5 sq. mm earth wire |
| 122 | 2x4.0 sq mm+1x4.0 sq. mm earth wire |
| 123 | S/F PVC conduit -Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess includingcutting the wall and making good the same in case recessed conduit as required. 20mm |
| 124 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required 5/6 amps, one way switch |
| 125 | 5/6 amps, 3 pin socket outlet |
| 126 | supplying and fixing stepped type fan regulator on the existing modular plate switch box. |
| 127 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 128 | S/F 3 pin 5 amp ceiling rose on the existing junction box wooden block including connection etc. as required |
| 129 | Supplying, fitting and fixing brass batten angele holder including connection etc. as required |
| 130 | S/F Electronic musical call bell - Supplying and fixing electronic musical call bell suitable for D.C/A.C. single phase, 230 volts, complete as required |
| 131 | I.T.C of exhaust fan up to 450mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc. as required |
| 132 | Supplying and Fixing TPN MCB DB: Supplying and Fixing of following way, three pole and neutral, sheet steel,MCB distribution board, 415 volts, on surface/recess, complete with tinned copper, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder including painting, earthing etc. as required( without MCB/RCCB/ISOLATOR). Make :- Havells / Standard / indoasian.4+12 ways, double door Horizontal type (4 Way) |
| 133 | 6 way (4 + 18), Double door, Horizontal type |
| 134 | S/F 5 amp. To 32 amp rating 240 volt \"C\" series miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc. a srequired. 6/32 amps, single pole \"B\" series |
| 135 | S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required40amp |
| 136 | 63amp |
| 137 | Earthing with G.I. earth plate 600mm x 600mm x 3mmthick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. (but without charcoal or coke and salt) |
| 138 | S/L 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc. as required |
| 139 | P/F G.I. lightning conductor final -Providing and fixing of lightning conductor final, made of 25mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required. |
| 140 | Reverting sweating and soldering of copper/G.I. tape (with another copper G.I. tape base of the final or any (other metalic object) as required |
| 141 | P/F G.I. lightning conductor tape in horizontal run -Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 142 | S/L 25mmx 5mm G.I. earth strip in ground - Supplying and laying 25mm x 5mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering etc. as required |
| 143 | P/F Testing joint G.I. lightning conductor -Providing and fixing testing joint, made of 20mm x 3mmthick G.I. strip, 125mm long, with 4 nos. of G.I. bolts, nuts, check nuts and spring washers etc. complete as required. |
| 144 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required. 30W LED Flood light |
| 145 | Supply, Installation, testing and commissioning of following, size ceiling fan 3 Blades confirming to IS : 374: 2019 including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. 1200mm (48\") BLDC 5star rating 32W Ceiling Fan |
| 146 | S.I.T.C. of following rating, surface mounted LED lightfitting, suitable for 230V 50Hz, single phase supply etc.complete as required. 20/22W LED Tube Light |
| 147 | 15/16 Watt LED Bulb |
| 148 | 9/10Watt LED Bulb |
| 149 | 12\" (300mm) metal exhaust fan |
| 150 | Supplying, installation, testing and commissioning ofcubical type MV Panel made out of 14 SWG sheet steel,totally enclosed IP-54 protection, free standing, floormounted dust and vermin proof, indoor typecompartmentalized powder coated of approved shadeafter antirust treatment (with min seven tanks ) suitablewith busbar interconnection with suitable size of copperlead/solid Aluminium strips, control circuits & bottombase channel of MS section not less than MS 40 X 40 X 5mm (thick), Fabrication shall be done in transportablesection ,entire panel shall have a common earth busbarat rear with 2 nos earth stud cable alleys, cable glandplates in two half as required as per single line diagram& specification enclosed with the following switchgears.4 pole MCCB 40 A,10 KA with fixed thermal magnetic setting. |
| 151 | 6/32 A,DP |
| 152 | 50/63 amps, DP |
| 153 | S/F busbar chamber - Providing and fixing followingcapacity busbar chamber with 4 strips of suitable sizemade of copper, heavy duty, complete with allaccessories including connections, earthing the body,etc as required 100 amps |
| 154 | S/F sheet metal ON/OFF Load changeover -Providing and fixing capacity 2 pole/4 pole ON/OFF loadchangeover switch with side handle operation, in sheetenclosure in existing metal board including drilling holesin metal board, making connection, earthing the hodyetc. as required.- 32 amps, 4 pole |
| 155 | Pilot lamp for indicator |
| 156 | 3 way 4 pole selector switch |
| 157 | DIGITAL VOLT METER 500V(3phase class 0.5) |
| 158 | DIGITAL A METER 500V(3phase class 0.5) |
| 159 | C.T. Coi |
| 160 | Panel Supplying, installation, testing and commissioningof cubical type MV Panel made out of 14 SWG sheetsteel, totally enclosed IP-54 protection, free standing,floor mounted dust and vermin proof, indoor typecompartmentalized powder coated of approved shadeafter antirust treatment (with min seven tanks ) suitablewith busbar interconnection with suitable size of copperlead/solid Aluminium strips, control circuits & bottombase channel of MS section not less than40mmx40mmx5mm (thick), Fabrication shall be done intransportable section ,entire panel shall have a commonearth busbar at rear with 2 nos earth stud cable alleys,cable gland plates in two half as required as per singleline diagram & specification enclosed with the followingswitchgears. |
| 161 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area forinstalation of pump set with Hydrolic DTH Rig machine all complete including all materials,tools,driling rig,air compressure and equipmentsas well as fule, lubricants and cost of transportationof rig machine and other vehical up to Site.(a) Up to 50 mtr Below G.L. |
| 162 | (b) Beyond 50 mtr. up to 150 mtr. Below G.L. |
| 163 | (c) From126.0 M to150.00 M |
| 164 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 165 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \"V\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/cdisinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 166 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 167 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 168 | Supplying Submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft andpolypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible Pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 2 HP |
| 169 | Supplying Fully automatic star delta starter to operate induction motor working on 415V, 3 phase, 50 hz with no volt coil, Over load element, ON-OFF push buttons, with necessary materials and connected to supply, etc. complete starter with original sheet steel encloser as per IS : 3914 |
| 170 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 171 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50 mm nominal dia Pipes |
| 172 | CARRIAGE OF MATERIALSSAND |
| 173 | LOCAL SAND |
| 174 | S.CHIPS |
| 175 | METAL |
| 176 | BRICKS |
| 177 | ADD GST @ 18 % |
| 178 | ADD LABOUR CESS @ 1 % Please Enable Macros to View BoQ information |