| 1 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 2 | 250x16 mm |
| 3 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 4 | 250x10 mm |
| 5 | 150x10 mm |
| 6 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 7 | 125 mm |
| 8 | 100 mm |
| 9 | Providing and fixing factory made uPVC door frame made of uPVC extrudedsectionshavinganoveralldimensionasbelow(tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer\"s specification and direction of Engineer- in-charge |
| 10 | Extruded section profile size 42x50 mm |
| 11 | Providing and fixing to existing door frames. |
| 12 | 24 mm thick factory made PVC door shutters made of styles cleats. The shutter frame filled and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mmhavingwallthickness1.0mmandstainlesssteel screws. The styles of the shutter reinforcedby inserting galvanised M.S. tube of size 20x20 mm and 1mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer- in-charge. (For W.C. and bathroom door shutter). |
| 13 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 14 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 16 | Two or more coats on new work |
| 17 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand andmanufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 18 | Old work (one or more coats) |
| 19 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 20 | Old work (One or more coat applied @0.90 Itr/10 sqm). |
| 21 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 22 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 23 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 24 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 25 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 26 | Of area 3 sq. metres and below |
| 27 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 28 | Of sectional area 40 square centimetres and above |
| 29 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 30 | Asbestos Cement sheet |
| 31 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 32 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 33 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer- in-charge. |
| 34 | Extra for providing and fixing anodized aluminium wind ties of size 40mm x 6mm (minimum weight 0.65 kg/m) over existing roofing/walling sheets, including cutting to required length, aligning, and securely fastening using existing roofing screw system or clamps, complete in all respects as per direction of Engineer-in-Charge |
| 35 | Providing and fixingPre-Printed galvanune (PPGL:) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal Indai Ltd. or equivalent (size, shape andpitch of corrugation as approved by Engineer-in-Charge) 0.50 mm ( + 0.05%) total coated thickness with zinc coating 150 grams per sqm as per IS:277, in 240 mps steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single lenght upto 12 metre or as desired by Engineer-in-Charge. The sheet shall be fixed using self drilling/self tapping screws (Xylan) of size (5.5 x 55 mm ) woith EPDM seal, complete upto any pitch in horozontal/ vertical or currved surfaces, excluding teh cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 36 | Providing and fixing pre-prinited galvanune )PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal Indai Ltd. or equivelent roofing accessories 0.50 mm (+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 227, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling /self tapping screws complete. |
| 37 | Ridges plain(500-600mm) |
| 38 | Barge board (Upto 300 mm) |
| 39 | Providing wood work in frames of trusses purlines, rafters, ties post fixed in position etc complete with: |
| 40 | Superior hard wood category-II (A) (Black chuglum, Thingam, Toungpeing, Pylinma, Koko and Mahawa) |
| 41 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 42 | Superior hard wood category-II (A) (Black chuglum, Thingam, Toungpeing, Pylinma, Koko and Mahawa) |
| 43 | Providing and laying cement concrete surface drain in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate of 40 mm nominal size), including floating coat of neat cement on the inside and exposed surfaces of the drain, with earthwork in excavation and disposal of surplus earth within a lead of 50 m. |
| 44 | 15cm x 15cm |
| 45 | Providing 25x5 mm flat iron hold fast 15 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 15 x 15 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 46 | Providing and fixing Anodized aluminium hooks and eyes : |
| 47 | 100 mm |
| 48 | Providing and fixing panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked stainless steel butt hinges of size 100x58x1.90 mm, IS:12817 marked (Grade 304), with necessary screws, excluding panelling which shall be paid for separately |
| 49 | Superior hardwood Category–II (A) (Black Chuglum, Thingam, Toungpeing, Pylinma, Koko and Mahawa) 35 mm thick shutters |
| 50 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked SS (304). pressed butt hinges bright finished of required size with necessary screws. |
| 51 | Superior hardwood Category–II (A) (Black Chuglum, Thingam, Toungpeing, Pylinma, Koko and Mahawa). 35 mm thick shutter |