| 1 | Taking down cement plaster inernal and external on brick or stone walls etc incl raking out joints, hacking for key, scrubbingdown with wateretc. |
| 2 | Dismantling stone slabs and tiles laid bedded and pointed in any mortar of anydescription or thickness in floors, aprons etc. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 4 | Demolition of stone, brick/PCC block masonry work built in cement mortar complete allas directed. |
| 5 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed. |
| 6 | Dismantaling timber scantling 40 Sq cm as in unframed workand over in sec in any position |
| 7 | Dismantlingtimber in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section |
| 8 | Dismantling plain or corrugated steel sheeting any thickness, complete all as specified and directed. |
| 9 | Dismantling of Wallandceilingboards(fibre, pulp, insulation, etc.) or insulationboards/slabs/ blankets, any thickness, including cover fillets. |
| 10 | S&F IIndclass HW plain solid straight chowkhats and frame wrought framed rebated on the soild rounded or chamfered put together with glue pinned at joints, complete all as specified and directed. |
| 11 | S&F 35mm thick 1st class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 12 | S/F 35 mm thick flush shutters,solid core construction with block board core and plywood face panel, one side commercial type and other side with decorative face veneer with lipping/frame to match , complete all as specified and directed. |
| 13 | Taking down chowkets or frame with shutter (without taking off shutters from the frame) n.exe 1.5 sqm each. |
| 14 | Taking down chowkhats or frame exc 1.5 sqmtrbut n.exc 4 sq m(without taking off shutters from frames), complete all as specified and directed. |
| 15 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 150 mm long, complete all as specified and directed. |
| 16 | Supply and fix mild steel butt hinges, medium weight, cold rolled 100 mm size , complete all as specified and directed. |
| 17 | Supply and fix Aluminium handles, cast type, anodized, 150 mm size , complete all as specified and directed. |
| 18 | Supply and fix 4 mm thick sheet glass, ordinary quality and glazing with oil putty in squaresn.exceeding 0.50sqm in each pane , complete all as specified and directed. |
| 19 | Hacking out old broken glass ( any thicknes, size, qualityor description) from wooden/metal frame including punching or drilling out old glazing pins/spring clips and providing new ones complete. |
| 20 | M&L Rendering 10mm thick CM (1:6) onother thanfair facesof brick workor concrete surfaces of wall ,finshing the surfaceeven and smooth without using extra cement complete. |
| 21 | M&L Rendering 10mm thick CM (1:4) onother thanfair facesof brick workor concrete surfaces of wall ,finshing the surfaceeven and smooth without using extra cement complete. |
| 22 | M&L for prep ofnewly plastered surfaces of wallsand applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed complete. |
| 23 | M& L for PCC 1:3:6 Type C2 (using 40mm graded aggr) in foundations, filling and massconcrete |
| 24 | M&L for Providingprecast cement concrete type C1 1:3:6 (20mm graded stone aggregate)solid building blocks or slabs exc 10cm thick (with plain or interlocking joints as directed)setting in mortar 1:6 ,complete, in walls |
| 25 | Supplied only liquid WPC |
| 26 | S& F Solid/Hollow PVC Wall Lining consisting of5mm thick Plain colour PVC sheetinclusive of solvent cement and fixing atsite on PVC frame as per specifications and drawing. |
| 27 | S & F5mm thick PVC sheet fillet of width35mm for wall paneling inclusive offixing on to wall to make PVC Frame asper specification and drawing. |
| 28 | S&F 300mm long aluminium anodized sliding door bolt with hasp and staple (bolt type and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sectionsor cast alluminium alloy complete all as specified and as directed. |
| 29 | M & L Mild steel work of angle iron or flat etc Hand rails, half round or other steel section or cor for wooden hand -rail straight portion, drilled and coundtersunk for balusters running bar, for door, balusters, nosing to steps including embeding in concrete and screwing etc.Wind tiles for roof including securing bolts, posts and struts in fencing including cutting tops to shape mas directed, drilling holes, notching for wire etc flat iron fillets(for securing wire mesh metc) including all necessary drilling, bolting or reveting etc and sililar work conforming to Fe -290 Gde E-165 |
| 30 | S & F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having rensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws as spefified. |
| 31 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 32 | M&L for 4mm thick plywood, grade BWR, type BB, fixed with nails to timber frameworkin wall only |
| 33 | M&L for cover fillets of tempered hard board6mm thick, 40mm widefixingwith screws in ceiling, flat or sloping complete all as specified and as directed |
| 34 | M&L for 75 mm thick 1:3:6 type C2 ( using 40 mm graded stone aggregate) as plinth rotection./paving/footpath. |
| 35 | M&L for 100 mm thick cement concrete 1:4:8type B2 ( using 40 mm graded stone aggregate) as in base coat. |
| 36 | M&L for 40 mm thick cement concrete 1:2:4 type B1 ( using 20 mm graded stone aggregate) as in floor /sub base coat. |
| 37 | M&L coloured glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick rendering in CM (1:4) on brick or concrete surfaces complete all as specified and directed. |
| 38 | M&L forNon skid coloured ceramic colouredtiles 7 to 8mm thick Square/rectangular) area of each tile exc 0.11 and nexc .18 sqm in flooretc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match inclscreed bed with CM (1:6) 15 mm thick for laying floor tiles complete all as specified and directed. |
| 39 | M & L for vitrified tiles light shade 8 to10mm thick square/rectangular) polished area of each tile 600mm x 600mm / 605mm x 605mm over andincluding15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 40 | M&L Rendering 15mm thick CM (1:4) onother thanfair facesof brick workor concrete surfaces of wall mixed with liquid WPC by 0.4% wt of cememnt,finshing the surfaceeven and smooth without using extra cement complete. |
| 41 | M&L for prep ofnewly plastered surfaces of wallsand applying two coats of cement base paint complete all as specified and as directed complete. |
| 42 | M&L for prepration of new wooden surfaces exc.10cm in width or girthand applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 43 | M&L preparing new steel surfaces of any description over 10cm width of 19M 19R girth and applying two coats of synthetic ebamel paint over coat of rex oxide zinc chrome primer complete all as specified and directed |
| 44 | Preparing of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 45 | M&L Second class hard wood clean swan timber framed work as in scantling. |
| 46 | M&Lsecond class soft wood plain fillets.square, rectangular or triangular in section, clean sawn, sectional area exc 13 sq cm and n exc 25 sq cm secured with nails |
| 47 | S & F30 mm thick flush shutters,solid core construction with block board core and plywood face panel, commercial type on both sides, complete all as specified and directed. |
| 48 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 125 mm long, complete all as specified and directed. |
| 49 | Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed |
| 50 | Supply and fix mild steel butt hinges, medium weight, cold rolled 125 mm size , complete all as specified and directed. |
| 51 | Taking down carefully aluminium point wiring (light, fan, socket or power) complete and making good disturbed surfaces of walls, floors, etc. all as directed.including taking down fittings such as switches, ceiling roses, regulators, sockets,lamp holders, ceiling fittings, bulk head fittings, tube light fittings etc |
| 52 | M & L for One light point or one fan point controlled by one wayswitch with 1.5 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl PVC casing capping with its accessories and PVC modular Boxes for fixing switches/sockets etc. |
| 53 | M & L for One light point or one fan point controlled by two wayswitch with 1.5 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl PVC casing capping with its accessories and PVC modular Boxes for fixing switches/sockets etc. |
| 54 | M/L for point wiring in casing caping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: One light/fan point controlled by one No piano type switch5 Amps single pole one way |
| 55 | All as per item No 55 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor. |
| 56 | One socket outlet 5/3 pin 6 AMPS controlled by one switch onindependent board. |
| 57 | M & L forOne 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 4.0 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC modular Boxes for fixing switches/sockets etc. |
| 58 | M & L forOne 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC modular Boxes for fixing switches/sockets etc. |
| 59 | M & L forOne 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC modular Boxes for fixing switches/sockets etc. |
| 60 | M&Lof circuit/submain wiring alongwithearth wire with the size of 2x6.0 Sqmm + 1x6.0 Sqmm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required in and including PVC cassing capping complete fixing on wall, roof and floorall as specified and directed by engineer-in-charge. |
| 61 | Refixing the decorativewalllight fitting taking down from item No-1 all as directed and specified. |
| 62 | S&F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body. |
| 63 | S&F sheet metal enclosuredistribution box4 way TPN 415 volts with suitable size ofrated bus bar double door complete including connecting up all as specified . |
| 64 | S&F sheet metal enclosuredistribution box8 way SPN 230 volts with 200 Amps rated bus bar double door complete including connecting up all as specified . |
| 65 | S&F socket outlet 2 in 1 ,3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. |
| 66 | S&F socket outlet 2 in 1,3 pin & 2 pin, 5/6 Amp, 240 volt. |
| 67 | S&F Switch Piano Flush button single pole one way 15/16 Amp. |
| 68 | Supply and fixingModular Socket, 6A - 2/3 pin Combined 2 module complete all as specified and as directedby engineer-in-charge. |
| 69 | Supply and fixingModular Socket,16A - 2/3 pin Combined 2 module complete all as specified and as directedby engineer-in-charge. |
| 70 | Supply and fixingModular switch 1 way 15A, 1 module complete all as specified and as directedby engineer-in-charge. |
| 71 | Supply and fixingModular switch 1 way 6A, 1 module complete all as specified and as directedby engineer-in-charge. |
| 72 | Supply and fixingModular switch 2 way 6A, 1 module complete all as specified and as directedby engineer-in-charge. |
| 73 | S&F Switch piano, flush type single pole, one way 5 Amp. |
| 74 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 75 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300 mm sweep with all fixing arrangementall as specified and as directed. |
| 76 | Supply and fixing in repair 415V 10KA \"C\" curve miniature circuit breaker TPN 40 To 100 AMP poles and current carrying capacity in the DB complete with connection testing and commissioning all as directed and as specified. |
| 77 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete as specified. |
| 78 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 79 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete. |
| 80 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 81 | Supply and fixing MCB 40 to 63 Amp SPN 240V, 10KA \"C\"complete with connection testing and commissioning. |
| 82 | Supply and fixing MCB 5- 32 Amp SP 240V, 10KA \"C\"complete with connection testing and commissioning. |
| 83 | Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edgeof the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized GI wire 4.0 mm asearthing lead by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and provision of concrete pit in PCC (1:3:6) type C1, pre-cast including RCC (1:2:4) type B1, cover slab54 cm x 54 cm x 5 cm, reinforced with 8 mm diaTMT bars @ 150 mm c/c both ways, one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil, dismantling and taking out old earthing plate and necessary testing complete all as shown on electrical plate No 5 of SSR Part –I (2009). |
| 84 | S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 Core including taking down old one. |
| 85 | M & L forXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. mm 4.0 Core. |
| 86 | Excavating in post holes (or similar holes) each n exc 0.5 cum getting out in hard/dense soil, returning,filling in and ramming earth or broken rubble mised with earth around, in layers not execcding 25 cm |
| 87 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, etc. or for laying of cable, pier holes, etc. nexc 10 sq m on plan andn exc 1.5 m in depth and getting out in hard & dense soil. |
| 88 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of any type of soil. |
| 89 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of any type of soil. |
| 90 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 35 sqmm 3.5 core complete including taking out old unserviceable cable all as specified and directed by Engineer in charge. |
| 91 | S&F high density polyethylene pipes (HDPE) of pressure rating 6Kgf/cm2 laid in trenches of size 50mm dia all as specified and directed by Engr-in-Charge. |
| 92 | S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 100 mm bore. |
| 93 | Supply, installation, commissioning and testing in replacementpowder coated factory made out door type double door Feeder panel box confirming to IP 66 protaction, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, pedastal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate including taking out old unserviceable feeder pillar Box.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- (a) Al bus bar of suitable capacity for phase and neutral.(b) Incoming MCCB 4 pole 125 Amps 25 KA alongwith Spreader terminals with adjustable thermal setting– 01 No(c) Three phase indication lamp |
| 94 | Supply, installation, commissioning and testing in replacementpowder coated factory made out door type double door Feeder panel box confirming to IP 66 protaction, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, pedastal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate including taking out old unserviceable feeder pillar Box.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- (a) Al bus bar of suitable capacity for phase and neutral.(b) Incoming MCCB 4 pole 125 Amps 25 KA alongwith Spreader terminals with adjustable thermal setting– 01 No(c) Outgoing MCCB 4 pole 100 Amps 16 KA alongwith Spreader terminals with adjustable thermal setting– 01 No(c) Three phase indication lamp |
| 95 | M & L for dismantling and taking up or down old unserviceable service cable /LT UG cable of any size complete all as specified and directed. |
| 96 | Demolation of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 97 | M & L for cable route marker with route indication on cast iron disc of 100mm dia and 10mm thick, marked / written for \" MES LT SIZE \" embosed including indicating direction fixed / bolted to 40mmx40mmx6mm thick MS angle iron support of 0.5m long embedded upto 200mm depth in concrete block of size 200mm x 200mm x 500mm of mix PCC 1:3:6, type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces complete all as specified and directed. |
| 98 | M & L for PCC (1:2:4) type B1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform etc including form work compaction etc all as specfied and directed by Engineer-in-Charge. |
| 99 | S&F GI Pipe 100 mm bore, \"light grade\",galvanised,with all fitting;laid in trenches. |