| 1 | SH: 50 seated Boys Hostel building |
| 2 | Excavation in decomposed or soft rock with or without blasting including disposal of the samelead upto 50 m and lift upto 1.50 m. |
| 3 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 4 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including rammingand watering etc. complete. |
| 5 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 6 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth |
| 7 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 8 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild steel |
| 9 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Column, pillars, posts and struts etc. |
| 10 | b) Lintels, beams, girders, bressumers and cantilevers etc. |
| 11 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas |
| 12 | d) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 13 | Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : a) M20 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 14 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 15 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 16 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20(1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 17 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 18 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 19 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 20 | Providing approved best available local wood (Class - B II) work in frames of doors,windows clerestory windows and other frames, wrought framed and fixed in position. |
| 21 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws. a) 38mm thick best available local wood class - B I |
| 22 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a) Ornamental grill. |
| 23 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 24 | b) 250x 16 mm |
| 25 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 26 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 250 x 10 mm |
| 27 | b) 150 x 10 mm |
| 28 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm |
| 29 | b) 100 mm |
| 30 | Providing and fixing MS Hooks and Eyes. a) 250 mm |
| 31 | Providing and fixing iron pressed butt hinges bright finished with necessary screws etc complete. |
| 32 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 33 | Pre-cast terrazzo tiles 20 mm thick with marble chips of sizes upto 6 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry including rubbing and polishing complete with tiles of : a) Light shades using white cement |
| 34 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall. |
| 35 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 36 | Applying priming coat consisting of a mixture of red lead, white lead and double boiled linseed oil in the ratio of 0.7 Kg : 0.7 Kg : 1 Litre on wood work complete. |
| 37 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 38 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give aneven shade. |
| 39 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 40 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 41 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore |
| 42 | b) 20 mm nominal bore |
| 43 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 15 mm nominal bore |
| 44 | b) 20 mm nominal bore |
| 45 | Providing and fixing brass bib cock of approved quality.a)15 mm nominal bore |
| 46 | Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore |
| 47 | b) 20 mm nominal bore |
| 48 | Providing and fixing PVC connection pipe with brass union. a) 20 mm nominal bore |
| 49 | Providing and fixing brass full way valve with wheel of approved quality.a) 32 mm nominal bore |
| 50 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) Long Pan patten WC Pan |
| 51 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC.a) 250 x 130 x 30 mm |
| 52 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 53 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass wasteof standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. |
| 54 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia |
| 55 | Water tank |
| 56 | SH: Septic tank |
| 57 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.a) Ordinary Soil |
| 58 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 59 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 60 | b) Walls including attached buttresses, pilasters and their caps andbases and string courses etc. up to floor two level. |
| 61 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 62 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 63 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild steel |
| 64 | Centring and shuttering including strutting proping etc. and removal of form work for: b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 65 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 66 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a) 100 mm dia SW pipes |
| 67 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design. a) 100 mm dia SW pipes |
| 68 | Electrification |
| 69 | Sh: Wiring |
| 70 | Wiring for light point / fan/ call ball point with 1.5 sqmm PVC insulated Aluminium conductor cable in surface consuit (PVC Casing caping) i/c painting etc.a) Short Point |
| 71 | Medium Point |
| 72 | Long Point |
| 73 | Wiring for 3 Pin 5Amp plug point with 1.5 sq mm PVC insulated alumenium conductor cable including providing and fixing of 5 Amp socket outlet on switch board in surface PVC casing caping wiring system and5 Amp piano type switch earth the third pin i/c, painting etc as required.Medium Point |
| 74 | Wiring for 3 Pin 15Amp plug point with 4 sq mm PVC insulated alumenium conductor cable including providing and fixing of 15 Amp socket outlet on switch board in surface PVC casing caping wiring system and15 Amp piano type switch earth the third pin i/c, painting etc as required. |
| 75 | Wiring for sub-main wiring with following PVC insulated Aluminium conductor cable in surface PVC casing caping as required. 2 X 2.5 Sq.mm |
| 76 | 2 X 4 Sq.mm |
| 77 | Wirring for circuit wirring with 2X1.5 sqmm PVC insulated Aluminium conductor cable single core in surfacePVC casing caping along with1 Nos 2.24 mm dia bare aluminum wire for loof earthing as required. |
| 78 | Wirring for circuit wirring with 2X4 sqmm PVC insulated Aluminium conductor cable single core in surfacePVC casing caping along with1 Nos 2.24 mm dia bare aluminum wire for loof earthing as required. |
| 79 | Supplying and drawing of following size PVC insulatedAluminium conductor cable single core in surface PVC casing caping as required. a) 2 X 1.5 Sq. mm |
| 80 | 2 X 2.5 Sq.mm |
| 81 | 2 X 4 Sq.mm |
| 82 | Sub-Head - II (Fitting and Accessories) |
| 83 | Supply and Fixing ofwooden board i/c varnished and connetion etc. as required. A) 18\"X12\" |
| 84 | 10\"X12\" |
| 85 | 6\"X8\" |
| 86 | 8\"X10\" |
| 87 | 7\"X4\" |
| 88 | Supply and Fixing of 5A switch on the existing wooden board i/c connection etc. as required |
| 89 | Supply and Fixing of 15A switch on the existing wooden board i/c connection etc. as required |
| 90 | Supply and Fixing of 3 Pin, 5A Socket outlet on the existing wooden board i/c connection etc. as required |
| 91 | Supply and Fixing of 3 Pin,15A Socket outlet on the existing wooden board i/c connection etc. as required |
| 92 | Supply and Fixing of celling rose on the existing wooden board i/c connection etc. as required. |
| 93 | Supply and Fixing of Plain pendant with 16/20 mm twin twished falexible PVC insulated cotton brabided copper cable and brass pendent holder i/c connection etc as required. |
| 94 | Supply and Fixing of bulk head fitting suitable for 100W lamp complete with accessories etc. as required. |
| 95 | Instalation,testing and commissioning of per wired flourescent fitting of all type complete with all accessories and tube etc directly on wall/cellingi/c connection with 1.5 sqmm PVC insulated conductor S/C cable etc. |
| 96 | Installtion, testing and commissioning of celling fan and regulator i/c wiring and down rod of standard length (upto 30cm) etc. as required. |
| 97 | Supply of dectrotive1X40W floursent tube fittine complete with all assessores like copper wounded choke, rotter holder, staters, condenser with tube light and aeryliec covers etc as required. |
| 98 | supply and Fixing of 1200mm size electro celing fan capacitor type complet with 30 cm down road, canopies hanging shackle, blades, and speed regulator suitable for use on 230/240 volt 50 HZ single phase AC supply conforming to IS: 374/1979 as required. (Khaitan Make) |
| 99 | Supplying and fixing of following size PVC casing caping on surface as required15 mm X 10 mm |
| 100 | 20 mm X 10 mm |
| 101 | 25 mm X 10 mm |
| 102 | 30 mm X 10 mm |
| 103 | Supplying and fixing of following size PVC TEE/L/and Sq Box as requireda) PVC TEE |
| 104 | PVC L |
| 105 | PVC Sq. Box |
| 106 | PVC external angel |
| 107 | PVC Internal angel |
| 108 | PVC coupler |
| 109 | Supplying and fixing of MS Fan clamp etc as required |
| 110 | Sub-Head - III (Main Switch & Service Connection) |
| 111 | Supplying & Fixing of 32A TPN MCB main switch with all assessories as required. |
| 112 | Supplying & Fixing of 16A TPN MCB main switch with all assessories as required. |
| 113 | Supplying & Fixing of following way single pole & natural sheet steel MCB distribution board 240Volts on surface/recess complete with tinned copper busbar neutral link earth bar,dinbar, detachable, glad plate, interconnection i/c painting earthing etc as required.4 way |
| 114 | 8 way |
| 115 | Supply of 32A Cut Out |
| 116 | Supply of 1 PH Energy Meter of range 0-20A i/c wiring etc. as required. |
| 117 | Supply and Fixing of 10 Sq.mm WPTC Alluminium conductor cable for service connection. |
| 118 | Supply and Fixing of 3.2 mtr long, 40 mm diameter service pipe with bend etc as required. |
| 119 | Supplying and fixing of following size Screwa) 1 Inch |
| 120 | 1/2 Inch |
| 121 | Sub-Head - IV (Earthing) |
| 122 | Earthing with GI pipe 4.50 mtr long and 40 mm diameter with necessary accssories and providing masonary enclosure with copper plate having lockaing arrangement and watering pipe ect(but without charcoal ore coke and salt) complete as required. |
| 123 | Extra for using salt and charcoal/choke for pipe earthing electrode as required. |
| 124 | Supplying and laying 8 SWG GI wire at 0.50 mtr below ground level for conductor earth electrode i/c soldering etc as required. |
| 125 | Providing and laying earth cunnection from earth electrode with 8 SWG GI wire in 15 mm dia GI pipe from earth electro as required. |
| 126 | Providing and fixing 8 SWG GI wire on surface or in recess for loop earthing as required |