| Sl. No. | Item Description |
| 1 | Type-II 4 units ( Double storey) |
| 2 | I. Earthwork |
| 3 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning. |
| 4 | II. CC Work |
| 5 | Providing and laying cement concrete 1 : 3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering ina) Foundations and plinth |
| 6 | Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 7 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 8 | III. RCC Work |
| 9 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 10 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 11 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 12 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 13 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement:1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 14 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 15 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 16 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 17 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 18 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 19 | e) Column, pillars, posts and struts etc. |
| 20 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT Steel |
| 21 | IV. Brick Work |
| 22 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:5 (1 cement : 5 fine sand). |
| 23 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 24 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 25 | Aluminium Works |
| 26 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 27 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 28 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) 4.1 With float glass panes of 4.0 mm thickness. |
| 29 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill. |
| 30 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 31 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete. |
| 32 | a) 300 x 10 mm |
| 33 | c) 150 x 10 mm |
| 34 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm |
| 35 | VI. Flooring |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm |
| 37 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm |
| 38 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 39 | VII. Roofing |
| 40 | Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 41 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages= 202.061 Sqm After H & L !aping as per manufacturer\"s specification, effective Area Measurable will be 20 x 3x 2.95 x 1.015 = 179.655 Sqm |
| 42 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of pur!ins, rafters and trusses. Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages= 12.566m After laping as per manufacturer\"s specification, effective Measurable length will be (4 x 3.05)- (3 x 0.15) = 11.75m |
| 43 | False Ceiling |
| 44 | Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately). |
| 45 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.a) Best local approved quality wood. |
| 46 | Extra for chamfered edges in beading |
| 47 | VII. Finishing |
| 48 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 49 | 15mm cement plaster 1:5 (1 cement : 5 fine sand) on the rough side of single or half brick wall |
| 50 | 6 mm cement plaster to ceiling 1 : 4 (1 cement: 4 fine sand). |
| 51 | Applying one coat of cemenl primer of approved brand and manufacture on wall surface. |
| 52 | Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade. |
| 53 | Distempering (lwo or more coats) with oil bound washable distemper of approved brandand manufacture and of required shade on new work over and including a priming coatwith distemper primer of approved brand and manufacture to give an even shade. |
| 54 | VIII. Miscelleneous |
| 55 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 56 | X. Water Supply |
| 57 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore |
| 58 | b) 20 mm nominal bore.Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). |
| 59 | a) 15 mm nominal bore |
| 60 | b) 20 mm nominal bore |
| 61 | d) 32 mm nominal bore |
| 62 | Providing and fixing brass bib cock of approved quality.a)15 mm nominal bore |
| 63 | Providing and fixing brass stop cock of approved quality.a) 15 mm nominal bore |
| 64 | XI. Sanitary Installations |
| 65 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. |
| 66 | a) Long Pan patten WC Pan |
| 67 | Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain inenamelledflushband,20mmoverflowpipewithspecialsandmosquitoproof coupling of approved municipal design complete including cutting and making good the walls and floors where required. |
| 68 | a) WC pan with white plastic seat and lid. |
| 69 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. |
| 70 | b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
| 71 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. |
| 72 | a) 250 x 130 x 30 mm |
| 73 | Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete. |
| 74 | Providing and fixing kitchen sink including making all connection excluding cost of fittings.a) White glazed fire clay sink size 600x450x150 mm |
| 75 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins. |
| 76 | Providing and fixing CP brass waste for wash basins and sinks. B)40 mm dia |
| 77 | Providing and fixing 100 mm sand cast iron grating for gulley, fioors or nahni trap. |
| 78 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 79 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 80 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size |
| 81 | Providing and fixing toilet paper holder.a) CP Brass |
| 82 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 83 | a) 100 mm dia |
| 84 | c) 50 mm dia |
| 85 | Providing and fixing UPVC/PVC heel rest sanitary bend. |
| 86 | a) 100 mm dia |
| 87 | c )50 mm dia |
| 88 | Providing and fixing PVC single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 89 | a) 100 x 100 x 100 mm |
| 90 | Providing and fixing PVC trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. |
| 91 | c) 100 mm inlet and 50 mm outlet |
| 92 | Cost for internal electrification |
| 93 | POINT WIRING |
| 94 | Supply, Installation, testing and commissioningConduit wiring for lights/ fan socket outlets as per the mode of measurements described in the specifications consisting of -a) Wiring in 25/20 mm Dia 2mm thick HMS ,MMS type ofPVC conduit as required.b) 1100V grade PVC insulated CuFR Wire.c) Insulated or base protective earthd) 1.6 mm thick Outlet boxes and junction box as per manufacturers standarde) Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto switch board, except where identified.f) Embedding/surface conduits and accessories in walls and floorsetc. duringconstruction and / or cutting chases(with chase cutting machine) and makinggood with finishing of wall after embedding of conduit on walls.g) Switch, socket outlet and necessary blank plates, Face-Plates etc. as required.f) All shuttered type sockets with earth terminal. SITC of moduller type Switch, Sockets ,Faceplates , 1.6 mm thick G.I Back Boxes in walls by Electrical Contractor. Colour / Shade / Type of all switch-socket to be as per the Client / Architech confirmation. |
| 95 | Wiring for primary points from SB to first light pointwith 3X1.5 sq. mm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box Average=5 mtr |
| 96 | Wiring for secondary light point with 3x1.5sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch, socket,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core wire etc as required. Average=3 mtr |
| 97 | Wiring for 16amp 3/5 pin socket outlet Control By 16A switch x 2nos on Same Board independent Location with 2X2.5 sq.mm + 1x 1.5sqmm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box. Average=8 mtr |
| 98 | Wiring for 16amp 3/5 pin socket outlet Control By 16A switch x 1nos on Same Board independent Location with 2X2.5 sq.mm + 1x 1.5sqmm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box. Average=8 mtr |
| 99 | Wiring for Two Nos 6amp, 3/5 pin socket outlet Control By Two Nos 6A switch on Same Board independent Locationwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=4 mtr |
| 100 | Wiring for 1 Nos 6amp, 3/5 pin socket outlet Control By 1 Nos 6A switch on Same Board independent Locationwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=4 mtr |
| 101 | Wiring for 1 Nos 6amp, 3/5 pin socket outlet Control By 1 Nos 6A switch on lighting switch boardwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=0.5 mtr |
| 102 | Wiring for SB to fan point with 3X1.5 sq. mmPVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch, fan regulator,modular plate, suitable GI box and 3\" deep fan box with hook (conduit & fan cost should be excluded) Average=6 mtr |
| 103 | Wiring for SB to exhuast fan point with 3X1.5 sq. mm PVC insulated copper FRLS wire concealed in HMS class PVC conduit , with modular switch, socket,modular plate, suitable GI box. |
| 104 | Wiring from DB to switch board (submain) wiring alongwith necessary earth wire for the following sizes of PVC insulated copper FRLS wire concealed in HMS class PVC conduitconductor, already laid concealed HMS class PVC conduit as required. (only wiring) |
| 105 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 106 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 107 | Supplying and fixing of following sizes of HMS class PVC conduitalong with accessories in concealed/surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 108 | 25 mm |
| 109 | 32 mm |
| 110 | LOW VOLTAGE WIRING |
| 111 | LVWires |
| 112 | Supply, Installation, testing and commissioning Indoors PVC insulated LV Wires on walls, ceiling, cable trays complete with clamps Termination etc |
| 113 | CAT 6 cabledata including terminations in already laid conduits. |
| 114 | For Telophone including terminations in already laid conduits. 2 pair 0.5mm |
| 115 | RG -6cable for TV outletincluding terminationsin already laid conduit. |
| 116 | RG -11 cable for TV outletincluding terminationsin already laid conduit. |
| 117 | LVCables |
| 118 | Supply, Installation, testing and commissioning Indoors multipair 0.5mm dia copper PVC insulated and sheathed, armoured telephone cables on walls, ceiling, cable trays complete with clamps Termination, cable markers etc. from MDF to the various tag blocks as specified and shown on drawings. |
| 119 | 10 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 120 | 20 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 121 | 50 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 122 | 100 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 123 | Supplying and fixing of following sizes of HMS class PVC conduitalong with accessories in concealed/surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 124 | 25 mm |
| 125 | 32 mm |
| 126 | LT CABLING SYSTEM |
| 127 | POWER CABLES |
| 128 | Supply and laying heavy duty 1100V grade XLPE insulated sheathed & armoured FRLScables indoor or outdoor with Cu conductors asspecified and shown on drgs. and as per IS 7098- part 1 of 1998 complete with:-a) Cable clamps on walls, columns, beams, cable markers etc.Cable Dressing on Trays,Trenches & HDPE Pipesb) Earthing the glands armouring etc.c) Aluminium tags for all XLPE Al/ Cu cables to be provided. |
| 129 | 4c x 1.5sq.mm Cu XLPE Cable |
| 130 | 4c x 2.5sq.mm Cu XLPE Cable |
| 131 | 4c x 4sq.mm Cu XLPE Cable |
| 132 | TERMINATIONS WITH SINGLE COMPRESSION GLANDS,LUGS & ACCESSORIES |
| 133 | 4c x 1.5sq.mm Cu XLPE Cable |
| 134 | 4c x 2.5sq.mm Cu XLPE Cable |
| 135 | 4c x 4sq.mm Cu XLPE Cable |
| 136 | 3c x 4sq.mm Cu XLPE Cable |
| 137 | 4c x 6sq.mm Cu XLPE Cable |
| 138 | 4c x 10sq.mm Cu XLPE Cable |
| 139 | Supply and laying heavy duty 1100V grade XLPE insulated sheathed & armoured FRLScables indoor or outdoor with AL conductors asspecified and shown on drgs. and as per IS 7098- part 1 of 1998 complete with:-a) Cable clamps on walls, columns, beams, cable markers etc.Cable Dressing on Trays,Trenches & HDPE Pipesb) Earthing the glands armouring etc.c) Aluminium tags for all XLPE Al/ Cu cables to be provided. |
| 140 | 3.5C x 120sq.mm AL XLPE Cable |
| 141 | 3.5C x 70sq.mm AL XLPE Cable |
| 142 | 3.5C x 50sq.mm AL XLPE Cable |
| 143 | 3.5C x 35sq.mm AL XLPE Cable |
| 144 | CABLE TRAY |
| 145 | Supply, Installation ofhot dip galvanisedcable trays with necessary painted M.S structural supports in horizontal or vertical formation & single / multitier formation, Quoted rates for installation shall include GI nut and bolt, bend, TEE joint, reducer, coupler and all necessary accessoriesGI channel supports @ 1000mm interval etc., to suit site conditions |
| 146 | 300mm width X 50 mm depth X 2 mm thickness (perforated ) |
| 147 | 150mm width X 50 mm depth X 2 mm thickness( Perforated ) |
| 148 | LIGHTING FIXTURES AND FANS |
| 149 | Supply, Installation, testing and commissioning of following light fixtures and fans as per drawings and specifications with all other accessories. The rate shall include all accessories required to complete the installation as required, Earthing of fittings & Connections from the ceiling rose or junction box of the fitting including Flexible Wires,hangers,chains Complete in all respect. |
| 150 | LED 18 W round shape Cielling Mounted |
| 151 | LED 30 W square shape Cielling Mounted 300 x 300mm |
| 152 | 80W CiellingMounted Fan 1200mm Dia |
| 153 | Door bell |
| 154 | Electric 5.5 L Instant Water Geyser | High Grade SS Tank |
| 155 | Exhaust Fan 6 inch Ventilation Fan Pure Copper Motor 150 mm |
| 156 | COMMON AREA/STAIRCASE/LOBBY ETC. |
| 157 | Primary Light points Lift lobbyin 25mm conduit Average-12mtr |
| 158 | Secondary Light pointsin 25mm conduitAverage-3 mtr |
| 159 | PANELS & DISTRIBUTION BOARDS |
| 160 | Supply, installation, testing and commissioning of cubicle type panels of 14 SWG CRCA sheet steel floor mounted totally enclosed with top and bottom cable entry and suitable for use on 433 V 3 phase 4 wire 50 c/s having 35 KA fault capacity complete and housed with Aluminium/copper bus bar equipments and their accessories including supply and fixing of base channels of 100x50x6mm as required and with following incoming and outgoing switchgear with protection, metering etc. complete as required and as per specification and schematic diagram. |
| 161 | 6 WAY TPN-DB LDB |
| 162 | 12 WAY SPNGR Floor |
| 163 | EARTHING SYSTEM |
| 164 | Chemical earthing 17,2mm dia 3 mtr long with 50kg BFC CompoundWith brick workchamber 300 x 300mm |
| 165 | 25 x 6 mm G.I. |
| 166 | 25 x 3 mm G.I. |
| 167 | 8 SWG G.I earthwires |
| 168 | 8 SWG Cu earthwires |
| 169 | Add Septic Tank(100 User) |
| 170 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t |
| 171 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 172 | Providing and laying cement concrete 1 : 3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering ina) Foundations and plinth |
| 173 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 174 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 175 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 176 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 177 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 178 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 179 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 180 | b) Tar/TMT Steel |
| 181 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 182 | 40 mm thick red oxide flooring, under layer of 30 mm thick cement concrete 1 : 2 : 4 (1cement: 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) & top layer of 10 mm thick plaster of cement red oxide mix (using 3.5 kg of red oxide of iron per 50 kg of cement) 1 : 3 (1 cement red oxide mix : 3 coarse sand) finished with a floating coat of neat cement red oxide mix of same proportion. |
| 183 | Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3coarse sand) finished with a floating coat of neat cement, including rounding of junctionswith floor.a) 18 mm thick |
| 184 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 185 | a) 100 mm dia |
| 186 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft andSW drain pipe 100 mmdia 1.80 m long complete,as per standard design. |
| 187 | Furniture |
| 188 | Type-III 4 units(Double storey) |
| 189 | I. Earthwork |
| 190 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning . |
| 191 | II. CC Work |
| 192 | Providing and laying cement concrete 1 : 3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering ina) Foundations and plinth |
| 193 | Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : |
| 194 | a) Foundations and plinth |
| 195 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 196 | III. RCC Work |
| 197 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : |
| 198 | b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 199 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 200 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 201 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 202 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. |
| 203 | b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 204 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement:1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 205 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 206 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 207 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 208 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 209 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 210 | e) Column, pillars, posts and struts etc. |
| 211 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 212 | b) Tar/TMT Steel |
| 213 | IV. Brick Work |
| 214 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:5 (1 cement : 5 fine sand). |
| 215 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 216 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 217 | Aluminium Works |
| 218 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 219 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 220 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 221 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) 4.1 With float glass panes of 4.0 mm thickness. |
| 222 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. |
| 223 | b) Ornamental grill. |
| 224 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. |
| 225 | a) 300 x 16 mm |
| 226 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete. |
| 227 | a) 300 x 10 mm |
| 228 | c) 150 x 10 mm |
| 229 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. |
| 230 | a) 125 mm |
| 231 | VI. Flooring |
| 232 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm |
| 233 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm |
| 234 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 235 | VII. Roofing |
| 236 | Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 237 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages= 202.061 Sqm After H & L !aping as per manufacturer\"s specification, effective Area Measurable will be 20 x 3x 2.95 x 1.015 = 179.655 Sqm |
| 238 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of pur!ins, rafters and trusses. Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages= 12.566m After laping as per manufacturer\"s specification, effective Measurable length will be (4 x 3.05)- (3 x 0.15) = 11.75m |
| 239 | False Ceiling |
| 240 | Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately). |
| 241 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. |
| 242 | a) Best local approved quality wood. |
| 243 | Extra for chamfered edges in beading |
| 244 | VII. Finishing |
| 245 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 246 | 15mm cement plaster 1:5 (1 cement : 5 fine sand) on the rough side of single or half brick wall |
| 247 | 6 mm cement plaster to ceiling 1 : 4 (1 cement: 4 fine sand). |
| 248 | Applying one coat of cemenl primer of approved brand and manufacture on wall surface. |
| 249 | Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade. |
| 250 | Distempering (lwo or more coats) with oil bound washable distemper of approved brandand manufacture and of required shade on new work over and including a priming coatwith distemper primer of approved brand and manufacture to give an even shade. |
| 251 | VIII. Miscelleneous |
| 252 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 253 | X. Water Supply |
| 254 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). |
| 255 | a) 15 mm nominal bore |
| 256 | b) 20 mm nominal bore |
| 257 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). |
| 258 | a) 15 mm nominal bore |
| 259 | b) 20 mm nominal bore |
| 260 | d) 32 mm nominal bore |
| 261 | Providing and fixing brass bib cock of approved quality. |
| 262 | a)15 mm nominal bore |
| 263 | Providing and fixing brass stop cock of approved quality. |
| 264 | a) 15 mm nominal bore |
| 265 | XI. Sanitary Installations |
| 266 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. |
| 267 | a) Long Pan patten WC Pan |
| 268 | Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain inenamelledflushband,20mmoverflowpipewithspecialsandmosquitoproof coupling of approved municipal design complete including cutting and making good the walls and floors where required. |
| 269 | a) WC pan with white plastic seat and lid. |
| 270 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. |
| 271 | b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
| 272 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. |
| 273 | a) 250 x 130 x 30 mm |
| 274 | Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete. |
| 275 | Providing and fixing kitchen sink including making all connection excluding cost of fittings.a) White glazed fire clay sink size 600x450x150 mm |
| 276 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins. |
| 277 | Providing and fixing CP brass waste for wash basins and sinks. B)40 mm dia |
| 278 | Providing and fixing 100 mm sand cast iron grating for gulley, fioors or nahni trap. |
| 279 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 280 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 281 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size |
| 282 | Providing and fixing toilet paper holder.a) CP Brass |
| 283 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 284 | a) 100 mm dia |
| 285 | c) 50 mm dia |
| 286 | Providing and fixing UPVC/PVC heel rest sanitary bend. |
| 287 | a) 100 mm dia |
| 288 | c )50 mm dia |
| 289 | Providing and fixing PVC single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 290 | a) 100 x 100 x 100 mm |
| 291 | Providing and fixing PVC trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. |
| 292 | c) 100 mm inlet and 50 mm outlet |
| 293 | Cost for internal electrification |
| 294 | POINT WIRING |
| 295 | Supply, Installation, testing and commissioningConduit wiring for lights/ fan socket outlets as per the mode of measurements described in the specifications consisting of -a) Wiring in 25/20 mm Dia 2mm thick HMS ,MMS type ofPVC conduit as required.b) 1100V grade PVC insulated CuFR Wire.c) Insulated or base protective earthd) 1.6 mm thick Outlet boxes and junction box as per manufacturers standarde) Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto switch board, except where identified.f) Embedding/surface conduits and accessories in walls and floorsetc. duringconstruction and / or cutting chases(with chase cutting machine) and makinggood with finishing of wall after embedding of conduit on walls.g) Switch, socket outlet and necessary blank plates, Face-Plates etc. as required.f) All shuttered type sockets with earth terminal. SITC of moduller type Switch, Sockets ,Faceplates , 1.6 mm thick G.I Back Boxes in walls by Electrical Contractor. Colour / Shade / Type of all switch-socket to be as per the Client / Architech confirmation. |
| 296 | Wiring for primary points from SB to first light pointwith 3X1.5 sq. mm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box Average=5 mtr |
| 297 | Wiring for secondary light point with 3x1.5sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch, socket,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core wire etc as required. Average=3 mtr |
| 298 | Wiring for 16amp 3/5 pin socket outlet Control By 16A switch x 2nos on Same Board independent Location with 2X2.5 sq.mm + 1x 1.5sqmm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box. Average=8 mtr |
| 299 | Wiring for 16amp 3/5 pin socket outlet Control By 16A switch x 1nos on Same Board independent Location with 2X2.5 sq.mm + 1x 1.5sqmm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box. Average=8 mtr |
| 300 | Wiring for Two Nos 6amp, 3/5 pin socket outlet Control By Two Nos 6A switch on Same Board independent Locationwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=4 mtr |
| 301 | Wiring for 1 Nos 6amp, 3/5 pin socket outlet Control By 1 Nos 6A switch on Same Board independent Locationwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=4 mtr |
| 302 | Wiring for 1 Nos 6amp, 3/5 pin socket outlet Control By 1 Nos 6A switch on lighting switch boardwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=0.5 mtr |
| 303 | Wiring for SB to fan point with 3X1.5 sq. mmPVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch, fan regulator,modular plate, suitable GI box and 3\" deep fan box with hook (conduit & fan cost should be excluded) Average=6 mtr |
| 304 | Wiring for SB to exhuast fan point with 3X1.5 sq. mm PVC insulated copper FRLS wire concealed in HMS class PVC conduit , with modular switch, socket,modular plate, suitable GI box. |
| 305 | Wiring from DB to switch board (submain) wiring alongwith necessary earth wire for the following sizes of PVC insulated copper FRLS wire concealed in HMS class PVC conduitconductor, already laid concealed HMS class PVC conduit as required. (only wiring) |
| 306 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 307 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 308 | 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire |
| 309 | 2 x 6.0 sq.mm + 1 X 4 sq.mm earthg wire |
| 310 | Supplying and fixing of following sizes of HMS class PVC conduitalong with accessories in concealed/surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 311 | 25 mm |
| 312 | 32 mm |
| 313 | LOW VOLTAGE WIRING |
| 314 | LVWires |
| 315 | Supply, Installation, testing and commissioning Indoors PVC insulated LV Wires on walls, ceiling, cable trays complete with clamps Termination etc |
| 316 | CAT 6 cabledata including terminations in already laid conduits. |
| 317 | For Telophone including terminations in already laid conduits. 2 pair 0.5mm |
| 318 | RG -6cable for TV outletincluding terminationsin already laid conduit. |
| 319 | RG -11 cable for TV outletincluding terminationsin already laid conduit. |
| 320 | LVCables |
| 321 | Supply, Installation, testing and commissioning Indoors multipair 0.5mm dia copper PVC insulated and sheathed, armoured telephone cables on walls, ceiling, cable trays complete with clamps Termination, cable markers etc. from MDF to the various tag blocks as specified and shown on drawings. |
| 322 | 10 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 323 | 20 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 324 | 50 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 325 | 100 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 326 | Supplying and fixing of following sizes of HMS class PVC conduitalong with accessories in concealed/surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 327 | 25 mm |
| 328 | 32 mm |
| 329 | TTB box with 20 pair krone |
| 330 | LT CABLING SYSTEM |
| 331 | POWER CABLES |
| 332 | Supply and laying heavy duty 1100V grade XLPE insulated sheathed & armoured FRLScables indoor or outdoor with Cu conductors asspecified and shown on drgs. and as per IS 7098- part 1 of 1998 complete with:-a) Cable clamps on walls, columns, beams, cable markers etc.Cable Dressing on Trays,Trenches & HDPE Pipesb) Earthing the glands armouring etc.c) Aluminium tags for all XLPE Al/ Cu cables to be provided. |
| 333 | 4c x 1.5sq.mm Cu XLPE Cable |
| 334 | 4c x 2.5sq.mm Cu XLPE Cable |
| 335 | 4c x 4sq.mm Cu XLPE Cable |
| 336 | 3c x 4sq.mm Cu XLPE Cable |
| 337 | TERMINATIONS WITH SINGLE COMPRESSION GLANDS,LUGS & ACCESSORIES |
| 338 | 4c x 1.5sq.mm Cu XLPE Cable |
| 339 | 4c x 2.5sq.mm Cu XLPE Cable |
| 340 | 4c x 4sq.mm Cu XLPE Cable |
| 341 | 3c x 4sq.mm Cu XLPE Cable |
| 342 | 4c x 6sq.mm Cu XLPE Cable |
| 343 | 4c x 10sq.mm Cu XLPE Cable |
| 344 | Supply and laying heavy duty 1100V grade XLPE insulated sheathed & armoured FRLScables indoor or outdoor with AL conductors asspecified and shown on drgs. and as per IS 7098- part 1 of 1998 complete with:-a) Cable clamps on walls, columns, beams, cable markers etc.Cable Dressing on Trays,Trenches & HDPE Pipesb) Earthing the glands armouring etc.c) Aluminium tags for all XLPE Al/ Cu cables to be provided. |
| 345 | 3.5C x 120sq.mm AL XLPE Cable |
| 346 | 3.5C x 70sq.mm AL XLPE Cable |
| 347 | 3.5C x 50sq.mm AL XLPE Cable |
| 348 | 3.5C x 35sq.mm AL XLPE Cable |
| 349 | CABLE TRAY |
| 350 | Supply, Installation ofhot dip galvanisedcable trays with necessary painted M.S structural supports in horizontal or vertical formation & single / multitier formation, Quoted rates for installation shall include GI nut and bolt, bend, TEE joint, reducer, coupler and all necessary accessoriesGI channel supports @ 1000mm interval etc., to suit site conditions |
| 351 | 450mm width X 50 mm depth X 2.0 mm thickness ( Ladder ) |
| 352 | 300mm width X 50 mm depth X 2 mm thickness (perforated ) |
| 353 | 150mm width X 50 mm depth X 2 mm thickness( Perforated ) |
| 354 | LIGHTING FIXTURES AND FANS |
| 355 | Supply, Installation, testing and commissioning of following light fixtures and fans as per drawings and specifications with all other accessories. The rate shall include all accessories required to complete the installation as required, Earthing of fittings & Connections from the ceiling rose or junction box of the fitting including Flexible Wires,hangers,chains Complete in all respect. |
| 356 | LED 18 W round shape Cielling Mounted |
| 357 | LED 30 W square shape Cielling Mounted 300 x 300mm |
| 358 | 80W CiellingMounted Fan 1200mm Dia |
| 359 | Door bell |
| 360 | Electric 5.5 L Instant Water Geyser | High Grade SS Tank |
| 361 | Exhaust Fan 6 inch Ventilation Fan Pure Copper Motor 150 mm |
| 362 | COMMON AREA/STAIRCASE/LOBBY ETC. |
| 363 | Primary Light points Lift lobbyin 25mm conduit Average-12mtr |
| 364 | Secondary Light pointsin 25mm conduitAverage-3 mtr |
| 365 | Add Septic Tank(100 User) |
| 366 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t |
| 367 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 368 | Providing and laying cement concrete 1 : 3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering ina) Foundations and plinth |
| 369 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 370 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 371 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 372 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 373 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 374 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 375 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 376 | b) Tar/TMT Steel |
| 377 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 378 | 40 mm thick red oxide flooring, under layer of 30 mm thick cement concrete 1 : 2 : 4 (1cement: 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) & top layer of 10 mm thick plaster of cement red oxide mix (using 3.5 kg of red oxide of iron per 50 kg of cement) 1 : 3 (1 cement red oxide mix : 3 coarse sand) finished with a floating coat of neat cement red oxide mix of same proportion. |
| 379 | Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3coarse sand) finished with a floating coat of neat cement, including rounding of junctionswith floor.a) 18 mm thick |
| 380 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 381 | a) 100 mm dia |
| 382 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft andSW drain pipe 100 mmdia 1.80 m long complete,as per standard design. |
| 383 | Furniture |
| 384 | Type-IV (Single storey) |
| 385 | I. Earthwork |
| 386 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning .... |
| 387 | II. CC Work |
| 388 | Providing and laying cement concrete 1 : 3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering ina) Foundations and plinth |
| 389 | Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : |
| 390 | a) Foundations and plinth |
| 391 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 392 | III. RCC Work |
| 393 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : |
| 394 | b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 395 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 396 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 397 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 398 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. |
| 399 | b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 400 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement:1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 401 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 402 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 403 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 404 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 405 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 406 | e) Column, pillars, posts and struts etc. |
| 407 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 408 | b) Tar/TMT Steel |
| 409 | IV. Brick Work |
| 410 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:5 (1 cement : 5 fine sand). |
| 411 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 412 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 413 | Aluminium Works |
| 414 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 415 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 416 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 417 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) 4.1 With float glass panes of 4.0 mm thickness. |
| 418 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. |
| 419 | b) Ornamental grill. |
| 420 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. |
| 421 | a) 300 x 16 mm |
| 422 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete. |
| 423 | a) 300 x 10 mm |
| 424 | c) 150 x 10 mm |
| 425 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. |
| 426 | a) 125 mm |
| 427 | VI. Flooring |
| 428 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm |
| 429 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm |
| 430 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 431 | VII. Roofing |
| 432 | Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 433 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages= 202.061 Sqm After H & L !aping as per manufacturer\"s specification, effective Area Measurable will be 20 x 3x 2.95 x 1.015 = 179.655 Sqm |
| 434 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of pur!ins, rafters and trusses. Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages= 12.566m After laping as per manufacturer\"s specification, effective Measurable length will be (4 x 3.05)- (3 x 0.15) = 11.75m |
| 435 | False Ceiling |
| 436 | Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately). |
| 437 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. |
| 438 | a) Best local approved quality wood. |
| 439 | Extra for chamfered edges in beading |
| 440 | VII. Finishing |
| 441 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 442 | 15mm cement plaster 1:5 (1 cement : 5 fine sand) on the rough side of single or half brick wall |
| 443 | 6 mm cement plaster to ceiling 1 : 4 (1 cement: 4 fine sand). |
| 444 | Applying one coat of cemenl primer of approved brand and manufacture on wall surface. |
| 445 | Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade. |
| 446 | Distempering (lwo or more coats) with oil bound washable distemper of approved brandand manufacture and of required shade on new work over and including a priming coatwith distemper primer of approved brand and manufacture to give an even shade. |
| 447 | X. Water Supply |
| 448 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). |
| 449 | a) 15 mm nominal bore |
| 450 | b) 20 mm nominal bore |
| 451 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). |
| 452 | a) 15 mm nominal bore |
| 453 | b) 20 mm nominal bore |
| 454 | d) 32 mm nominal bore |
| 455 | Providing and fixing brass bib cock of approved quality. |
| 456 | a)15 mm nominal bore |
| 457 | Providing and fixing brass stop cock of approved quality. |
| 458 | a) 15 mm nominal bore |
| 459 | XI. Sanitary Installations |
| 460 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. |
| 461 | a) Long Pan patten WC Pan |
| 462 | Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain inenamelledflushband,20mmoverflowpipewithspecialsandmosquitoproof coupling of approved municipal design complete including cutting and making good the walls and floors where required. |
| 463 | a) WC pan with white plastic seat and lid. |
| 464 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. |
| 465 | b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
| 466 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. |
| 467 | a) 250 x 130 x 30 mm |
| 468 | Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete. |
| 469 | Providing and fixing kitchen sink including making all connection excluding cost of fittings.a) White glazed fire clay sink size 600x450x150 mm |
| 470 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins. |
| 471 | Providing and fixing CP brass waste for wash basins and sinks. B)40 mm dia |
| 472 | Providing and fixing 100 mm sand cast iron grating for gulley, fioors or nahni trap. |
| 473 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 474 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 475 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size |
| 476 | Providing and fixing toilet paper holder.a) CP Brass |
| 477 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 478 | a) 100 mm dia |
| 479 | c) 50 mm dia |
| 480 | Providing and fixing UPVC/PVC heel rest sanitary bend. |
| 481 | a) 100 mm dia |
| 482 | c )50 mm dia |
| 483 | Providing and fixing PVC single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 484 | a) 100 x 100 x 100 mm |
| 485 | Providing and fixing PVC trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. |
| 486 | c) 100 mm inlet and 50 mm outlet |
| 487 | Cost for internal electrification |
| 488 | POINT WIRING |
| 489 | Supply, Installation, testing and commissioningConduit wiring for lights/ fan socket outlets as per the mode of measurements described in the specifications consisting of -a) Wiring in 25/20 mm Dia 2mm thick HMS ,MMS type ofPVC conduit as required.b) 1100V grade PVC insulated CuFR Wire.c) Insulated or base protective earthd) 1.6 mm thick Outlet boxes and junction box as per manufacturers standarde) Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto switch board, except where identified.f) Embedding/surface conduits and accessories in walls and floorsetc. duringconstruction and / or cutting chases(with chase cutting machine) and makinggood with finishing of wall after embedding of conduit on walls.g) Switch, socket outlet and necessary blank plates, Face-Plates etc. as required.f) All shuttered type sockets with earth terminal. SITC of moduller type Switch, Sockets ,Faceplates , 1.6 mm thick G.I Back Boxes in walls by Electrical Contractor. Colour / Shade / Type of all switch-socket to be as per the Client / Architech confirmation. |
| 490 | Wiring for primary points from SB to first light pointwith 3X1.5 sq. mm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box Average=5 mtr |
| 491 | Wiring for secondary light point with 3x1.5sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch, socket,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core wire etc as required. Average=3 mtr |
| 492 | Wiring for 16amp 3/5 pin socket outlet Control By 16A switch x 2nos on Same Board independent Location with 2X2.5 sq.mm + 1x 1.5sqmm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box. Average=8 mtr |
| 493 | Wiring for 16amp 3/5 pin socket outlet Control By 16A switch x 1nos on Same Board independent Location with 2X2.5 sq.mm + 1x 1.5sqmm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box. Average=8 mtr |
| 494 | Wiring for Two Nos 6amp, 3/5 pin socket outlet Control By Two Nos 6A switch on Same Board independent Locationwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=4 mtr |
| 495 | Wiring for 1 Nos 6amp, 3/5 pin socket outlet Control By 1 Nos 6A switch on Same Board independent Locationwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=4 mtr |
| 496 | Wiring for 1 Nos 6amp, 3/5 pin socket outlet Control By 1 Nos 6A switch on lighting switch boardwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=0.5 mtr |
| 497 | Wiring for SB to fan point with 3X1.5 sq. mmPVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch, fan regulator,modular plate, suitable GI box and 3\" deep fan box with hook (conduit & fan cost should be excluded) Average=6 mtr |
| 498 | Wiring for SB to exhuast fan point with 3X1.5 sq. mm PVC insulated copper FRLS wire concealed in HMS class PVC conduit , with modular switch, socket,modular plate, suitable GI box. |
| 499 | Wiring from DB to switch board (submain) wiring alongwith necessary earth wire for the following sizes of PVC insulated copper FRLS wire concealed in HMS class PVC conduitconductor, already laid concealed HMS class PVC conduit as required. (only wiring) |
| 500 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 501 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 502 | 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire |
| 503 | 2 x 6.0 sq.mm + 1 X 4 sq.mm earthg wire |
| 504 | Supplying and fixing of following sizes of HMS class PVC conduitalong with accessories in concealed/surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 505 | 25 mm |
| 506 | 32 mm |
| 507 | LOW VOLTAGE WIRING |
| 508 | LVWires |
| 509 | Supply, Installation, testing and commissioning Indoors PVC insulated LV Wires on walls, ceiling, cable trays complete with clamps Termination etc |
| 510 | CAT 6 cabledata including terminations in already laid conduits. |
| 511 | For Telophone including terminations in already laid conduits. 2 pair 0.5mm |
| 512 | RG -6cable for TV outletincluding terminationsin already laid conduit. |
| 513 | RG -11 cable for TV outletincluding terminationsin already laid conduit. |
| 514 | LVCables |
| 515 | Supply, Installation, testing and commissioning Indoors multipair 0.5mm dia copper PVC insulated and sheathed, armoured telephone cables on walls, ceiling, cable trays complete with clamps Termination, cable markers etc. from MDF to the various tag blocks as specified and shown on drawings. |
| 516 | 10 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 517 | 20 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 518 | 50 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 519 | 100 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 520 | Supplying and fixing of following sizes of HMS class PVC conduitalong with accessories in concealed/surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 521 | 25 mm |
| 522 | 32 mm |
| 523 | TTB box with 20 pair krone |
| 524 | LT CABLING SYSTEM |
| 525 | POWER CABLES |
| 526 | Supply and laying heavy duty 1100V grade XLPE insulated sheathed & armoured FRLScables indoor or outdoor with Cu conductors asspecified and shown on drgs. and as per IS 7098- part 1 of 1998 complete with:-a) Cable clamps on walls, columns, beams, cable markers etc.Cable Dressing on Trays,Trenches & HDPE Pipesb) Earthing the glands armouring etc.c) Aluminium tags for all XLPE Al/ Cu cables to be provided. |
| 527 | 4c x 1.5sq.mm Cu XLPE Cable |
| 528 | 4c x 2.5sq.mm Cu XLPE Cable |
| 529 | 4c x 4sq.mm Cu XLPE Cable |
| 530 | 3c x 4sq.mm Cu XLPE Cable |
| 531 | 4c x 6sq.mm Cu XLPE Cable |
| 532 | TERMINATIONS WITH SINGLE COMPRESSION GLANDS,LUGS & ACCESSORIES |
| 533 | 4c x 1.5sq.mm Cu XLPE Cable |
| 534 | 4c x 2.5sq.mm Cu XLPE Cable |
| 535 | 4c x 4sq.mm Cu XLPE Cable |
| 536 | 3c x 4sq.mm Cu XLPE Cable |
| 537 | 4c x 6sq.mm Cu XLPE Cable |
| 538 | 4c x 10sq.mm Cu XLPE Cable |
| 539 | Supply and laying heavy duty 1100V grade XLPE insulated sheathed & armoured FRLScables indoor or outdoor with AL conductors asspecified and shown on drgs. and as per IS 7098- part 1 of 1998 complete with:-a) Cable clamps on walls, columns, beams, cable markers etc.Cable Dressing on Trays,Trenches & HDPE Pipesb) Earthing the glands armouring etc.c) Aluminium tags for all XLPE Al/ Cu cables to be provided. |
| 540 | 3.5C x 120sq.mm AL XLPE Cable |
| 541 | 3.5C x 70sq.mm AL XLPE Cable |
| 542 | 3.5C x 50sq.mm AL XLPE Cable |
| 543 | 3.5C x 35sq.mm AL XLPE Cable |
| 544 | 3.5C x 50sq.mm AL XLPE Cable |
| 545 | 3.5Cx 35sq.mm AL XLPe Cable |
| 546 | CABLE TRAY |
| 547 | Supply, Installation ofhot dip galvanisedcable trays with necessary painted M.S structural supports in horizontal or vertical formation & single / multitier formation, Quoted rates for installation shall include GI nut and bolt, bend, TEE joint, reducer, coupler and all necessary accessoriesGI channel supports @ 1000mm interval etc., to suit site conditions |
| 548 | 450mm width X 50 mm depth X 2.0 mm thickness ( Ladder ) |
| 549 | 300mm width X 50 mm depth X 2 mm thickness (perforated ) |
| 550 | 150mm width X 50 mm depth X 2 mm thickness( Perforated ) |
| 551 | LIGHTING FIXTURES AND FANS |
| 552 | Supply, Installation, testing and commissioning of following light fixtures and fans as per drawings and specifications with all other accessories. The rate shall include all accessories required to complete the installation as required, Earthing of fittings & Connections from the ceiling rose or junction box of the fitting including Flexible Wires,hangers,chains Complete in all respect. |
| 553 | LED 18 W round shape Cielling Mounted |
| 554 | LED 30 W square shape Cielling Mounted 300 x 300mm |
| 555 | 80W CiellingMounted Fan 1200mm Dia |
| 556 | Door bell |
| 557 | Electric 5.5 L Instant Water Geyser | High Grade SS Tank |
| 558 | Exhaust Fan 6 inch Ventilation Fan Pure Copper Motor 150 mm |
| 559 | COMMON AREA/STAIRCASE/LOBBY ETC. |
| 560 | Primary Light points Lift lobbyin 25mm conduit Average-12mtr |
| 561 | Secondary Light pointsin 25mm conduitAverage-3 mtr |
| 562 | PANELS & DISTRIBUTION BOARDS |
| 563 | Supply, installation, testing and commissioning of cubicle type panels of 14 SWG CRCA sheet steel floor mounted totally enclosed with top and bottom cable entry and suitable for use on 433 V 3 phase 4 wire 50 c/s having 35 KA fault capacity complete and housed with Aluminium/copper bus bar equipments and their accessories including supply and fixing of base channels of 100x50x6mm as required and with following incoming and outgoing switchgear with protection, metering etc. complete as required and as per specification and schematic diagram. |
| 564 | 6 WAY TPN-DB LDB |
| 565 | 12 WAY SPNGR Floor |
| 566 | Add Carrying charges |
| 567 | Add Septic Tank(100 User) |
| 568 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t |
| 569 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 570 | Providing and laying cement concrete 1 : 3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering ina) Foundations and plinth |
| 571 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 572 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 573 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 574 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 575 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 576 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 577 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 578 | b) Tar/TMT Steel |
| 579 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 580 | 40 mm thick red oxide flooring, under layer of 30 mm thick cement concrete 1 : 2 : 4 (1cement: 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) & top layer of 10 mm thick plaster of cement red oxide mix (using 3.5 kg of red oxide of iron per 50 kg of cement) 1 : 3 (1 cement red oxide mix : 3 coarse sand) finished with a floating coat of neat cement red oxide mix of same proportion. |
| 581 | Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3coarse sand) finished with a floating coat of neat cement, including rounding of junctionswith floor.a) 18 mm thick |
| 582 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 583 | a) 100 mm dia |
| 584 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft andSW drain pipe 100 mmdia 1.80 m long complete,as per standard design. |
| 585 | Add Carrying Charges |
| 586 | Furniture |
| 587 | Double storey Office Building |
| 588 | I. Earthwork |
| 589 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning .... |
| 590 | II. CC Work |
| 591 | Providing and laying cement concrete 1 : 3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering ina) Foundations and plinth |
| 592 | Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : |
| 593 | a) Foundations and plinth |
| 594 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 595 | III. RCC Work |
| 596 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : |
| 597 | b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 598 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 599 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 600 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 601 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. |
| 602 | b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 603 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement:1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 604 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 605 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 606 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 607 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 608 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 609 | e) Column, pillars, posts and struts etc. |
| 610 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 611 | b) Tar/TMT Steel |
| 612 | IV. Brick Work |
| 613 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:5 (1 cement : 5 fine sand). |
| 614 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 615 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 616 | Aluminium Works |
| 617 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 618 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 619 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 620 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) 4.1 With float glass panes of 4.0 mm thickness. |
| 621 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. |
| 622 | b) Ornamental grill. |
| 623 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. |
| 624 | a) 300 x 16 mm |
| 625 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete. |
| 626 | a) 300 x 10 mm |
| 627 | c) 150 x 10 mm |
| 628 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. |
| 629 | a) 125 mm |
| 630 | VI. Flooring |
| 631 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm |
| 632 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm |
| 633 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 634 | VII. Roofing |
| 635 | Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 636 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages= 202.061 Sqm After H & L !aping as per manufacturer\"s specification, effective Area Measurable will be 20 x 3x 2.95 x 1.015 = 179.655 Sqm |
| 637 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of pur!ins, rafters and trusses. Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages= 12.566m After laping as per manufacturer\"s specification, effective Measurable length will be (4 x 3.05)- (3 x 0.15) = 11.75m |
| 638 | False Ceiling |
| 639 | Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately). |
| 640 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. |
| 641 | a) Best local approved quality wood. |
| 642 | Extra for chamfered edges in beading |
| 643 | VII. Finishing |
| 644 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 645 | 15mm cement plaster 1:5 (1 cement : 5 fine sand) on the rough side of single or half brick wall |
| 646 | 6 mm cement plaster to ceiling 1 : 4 (1 cement: 4 fine sand). |
| 647 | Applying one coat of cemenl primer of approved brand and manufacture on wall surface. |
| 648 | Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give an even shade. |
| 649 | Distempering (lwo or more coats) with oil bound washable distemper of approved brandand manufacture and of required shade on new work over and including a priming coatwith distemper primer of approved brand and manufacture to give an even shade. |
| 650 | VIII. Miscelleneous |
| 651 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 652 | X. Water Supply |
| 653 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). |
| 654 | a) 15 mm nominal bore |
| 655 | b) 20 mm nominal bore |
| 656 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). |
| 657 | a) 15 mm nominal bore |
| 658 | b) 20 mm nominal bore |
| 659 | d) 32 mm nominal bore |
| 660 | Providing and fixing brass bib cock of approved quality. |
| 661 | a)15 mm nominal bore |
| 662 | Providing and fixing brass stop cock of approved quality. |
| 663 | a) 15 mm nominal bore |
| 664 | XI. Sanitary Installations |
| 665 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. |
| 666 | a) Long Pan patten WC Pan |
| 667 | Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain inenamelledflushband,20mmoverflowpipewithspecialsandmosquitoproof coupling of approved municipal design complete including cutting and making good the walls and floors where required. |
| 668 | a) WC pan with white plastic seat and lid. |
| 669 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. |
| 670 | b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
| 671 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. |
| 672 | a) 250 x 130 x 30 mm |
| 673 | Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete. |
| 674 | Providing and fixing CP brass waste for wash basins and sinks. B)40 mm dia |
| 675 | Providing and fixing 100 mm sand cast iron grating for gulley, fioors or nahni trap. |
| 676 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 677 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 678 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size |
| 679 | Providing and fixing toilet paper holder.a) CP Brass |
| 680 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 681 | a) 100 mm dia |
| 682 | c) 50 mm dia |
| 683 | Providing and fixing UPVC/PVC heel rest sanitary bend. |
| 684 | a) 100 mm dia |
| 685 | c )50 mm dia |
| 686 | Providing and fixing PVC single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 687 | a) 100 x 100 x 100 mm |
| 688 | Providing and fixing PVC trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. |
| 689 | c) 100 mm inlet and 50 mm outlet |
| 690 | Cost for internal electrification |
| 691 | POINT WIRING |
| 692 | Supply, Installation, testing and commissioningConduit wiring for lights/ fan socket outlets as per the mode of measurements described in the specifications consisting of -a) Wiring in 25/20 mm Dia 2mm thick HMS ,MMS type ofPVC conduit as required.b) 1100V grade PVC insulated CuFR Wire.c) Insulated or base protective earthd) 1.6 mm thick Outlet boxes and junction box as per manufacturers standarde) Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto switch board, except where identified.f) Embedding/surface conduits and accessories in walls and floorsetc. duringconstruction and / or cutting chases(with chase cutting machine) and makinggood with finishing of wall after embedding of conduit on walls.g) Switch, socket outlet and necessary blank plates, Face-Plates etc. as required.f) All shuttered type sockets with earth terminal. SITC of moduller type Switch, Sockets ,Faceplates , 1.6 mm thick G.I Back Boxes in walls by Electrical Contractor. Colour / Shade / Type of all switch-socket to be as per the Client / Architech confirmation. |
| 693 | Wiring for primary points from SB to first light pointwith 3X1.5 sq. mm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box Average=5 mtr |
| 694 | Wiring for secondary light point with 3x1.5sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch, socket,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core wire etc as required. Average=3 mtr |
| 695 | Wiring for 16amp 3/5 pin socket outlet Control By 16A switch x 2nos on Same Board independent Location with 2X2.5 sq.mm + 1x 1.5sqmm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box. Average=8 mtr |
| 696 | Wiring for 16amp 3/5 pin socket outlet Control By 16A switch x 1nos on Same Board independent Location with 2X2.5 sq.mm + 1x 1.5sqmm PVC insulated copper FRLS wire concealed in HMS class PVC conduit with modular switch, socket,modular plate, suitable GI box. Average=8 mtr |
| 697 | Wiring for Two Nos 6amp, 3/5 pin socket outlet Control By Two Nos 6A switch on Same Board independent Locationwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=4 mtr |
| 698 | Wiring for 1 Nos 6amp, 3/5 pin socket outlet Control By 1 Nos 6A switch on Same Board independent Locationwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=4 mtr |
| 699 | Wiring for 1 Nos 6amp, 3/5 pin socket outlet Control By 1 Nos 6A switch on lighting switch boardwith 3X1.5 sq.mm PVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch,socket, modular plate, suitable GI box.Average=0.5 mtr |
| 700 | Wiring for SB to fan point with 3X1.5 sq. mmPVC insulated copper FRLS wire concealed in HMS class PVC conduitwith modular switch, fan regulator,modular plate, suitable GI box and 3\" deep fan box with hook (conduit & fan cost should be excluded) Average=6 mtr |
| 701 | Wiring for SB to exhuast fan point with 3X1.5 sq. mm PVC insulated copper FRLS wire concealed in HMS class PVC conduit , with modular switch, socket,modular plate, suitable GI box. |
| 702 | Wiring from DB to switch board (submain) wiring alongwith necessary earth wire for the following sizes of PVC insulated copper FRLS wire concealed in HMS class PVC conduitconductor, already laid concealed HMS class PVC conduit as required. (only wiring) |
| 703 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 704 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 705 | 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire |
| 706 | 2 x 6.0 sq.mm + 1 X 4 sq.mm earthg wire |
| 707 | Supplying and fixing of following sizes of HMS class PVC conduitalong with accessories in concealed/surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 708 | 25 mm |
| 709 | 32 mm |
| 710 | LOW VOLTAGE WIRING |
| 711 | LVWires |
| 712 | Supply, Installation, testing and commissioning Indoors PVC insulated LV Wires on walls, ceiling, cable trays complete with clamps Termination etc |
| 713 | CAT 6 cabledata including terminations in already laid conduits. |
| 714 | For Telophone including terminations in already laid conduits. 2 pair 0.5mm |
| 715 | RG -6cable for TV outletincluding terminationsin already laid conduit. |
| 716 | RG -11 cable for TV outletincluding terminationsin already laid conduit. |
| 717 | LVCables |
| 718 | Supply, Installation, testing and commissioning Indoors multipair 0.5mm dia copper PVC insulated and sheathed, armoured telephone cables on walls, ceiling, cable trays complete with clamps Termination, cable markers etc. from MDF to the various tag blocks as specified and shown on drawings. |
| 719 | 10 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 720 | 20 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 721 | 50 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 722 | 100 pair 0.5 mm twisted pair non jelly filled armoured telephone cable |
| 723 | Supplying and fixing of following sizes of HMS class PVC conduitalong with accessories in concealed/surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 724 | 25 mm |
| 725 | 32 mm |
| 726 | TTB box with 20 pair krone |
| 727 | LT CABLING SYSTEM |
| 728 | POWER CABLES |
| 729 | Supply and laying heavy duty 1100V grade XLPE insulated sheathed & armoured FRLScables indoor or outdoor with Cu conductors asspecified and shown on drgs. and as per IS 7098- part 1 of 1998 complete with:-a) Cable clamps on walls, columns, beams, cable markers etc.Cable Dressing on Trays,Trenches & HDPE Pipesb) Earthing the glands armouring etc.c) Aluminium tags for all XLPE Al/ Cu cables to be provided. |
| 730 | 4c x 1.5sq.mm Cu XLPE Cable |
| 731 | 4c x 2.5sq.mm Cu XLPE Cable |
| 732 | 4c x 4sq.mm Cu XLPE Cable |
| 733 | 3c x 4sq.mm Cu XLPE Cable |
| 734 | TERMINATIONS WITH SINGLE COMPRESSION GLANDS,LUGS & ACCESSORIES |
| 735 | 4c x 1.5sq.mm Cu XLPE Cable |
| 736 | 4c x 2.5sq.mm Cu XLPE Cable |
| 737 | 4c x 4sq.mm Cu XLPE Cable |
| 738 | 3c x 4sq.mm Cu XLPE Cable |
| 739 | 4c x 6sq.mm Cu XLPE Cable |
| 740 | 4c x 10sq.mm Cu XLPE Cable |
| 741 | Supply and laying heavy duty 1100V grade XLPE insulated sheathed & armoured FRLScables indoor or outdoor with AL conductors asspecified and shown on drgs. and as per IS 7098- part 1 of 1998 complete with:-a) Cable clamps on walls, columns, beams, cable markers etc.Cable Dressing on Trays,Trenches & HDPE Pipesb) Earthing the glands armouring etc.c) Aluminium tags for all XLPE Al/ Cu cables to be provided. |
| 742 | 3.5C x 120sq.mm AL XLPE Cable |
| 743 | 3.5C x 70sq.mm AL XLPE Cable |
| 744 | 3.5C x 50sq.mm AL XLPE Cable |
| 745 | 3.5C x 35sq.mm AL XLPE Cable |
| 746 | CABLE TRAY |
| 747 | Supply, Installation ofhot dip galvanisedcable trays with necessary painted M.S structural supports in horizontal or vertical formation & single / multitier formation, Quoted rates for installation shall include GI nut and bolt, bend, TEE joint, reducer, coupler and all necessary accessoriesGI channel supports @ 1000mm interval etc., to suit site conditions |
| 748 | 450mm width X 50 mm depth X 2.0 mm thickness ( Ladder ) |
| 749 | 300mm width X 50 mm depth X 2 mm thickness (perforated ) |
| 750 | 150mm width X 50 mm depth X 2 mm thickness( Perforated ) |
| 751 | LIGHTING FIXTURES AND FANS |
| 752 | Supply, Installation, testing and commissioning of following light fixtures and fans as per drawings and specifications with all other accessories. The rate shall include all accessories required to complete the installation as required, Earthing of fittings & Connections from the ceiling rose or junction box of the fitting including Flexible Wires,hangers,chains Complete in all respect. |
| 753 | LED 18 W round shape Cielling Mounted |
| 754 | LED 30 W square shape Cielling Mounted 300 x 300mm |
| 755 | 80W CiellingMounted Fan 1200mm Dia |
| 756 | Exhaust Fan 6 inch Ventilation Fan Pure Copper Motor 150 mm |
| 757 | COMMON AREA/STAIRCASE/LOBBY ETC. |
| 758 | Primary Light points Lift lobbyin 25mm conduit Average-12mtr |
| 759 | Secondary Light pointsin 25mm conduitAverage-3 mtr |
| 760 | PANELS & DISTRIBUTION BOARDS |
| 761 | Supply, installation, testing and commissioning of cubicle type panels of 14 SWG CRCA sheet steel floor mounted totally enclosed with top and bottom cable entry and suitable for use on 433 V 3 phase 4 wire 50 c/s having 35 KA fault capacity complete and housed with Aluminium/copper bus bar equipments and their accessories including supply and fixing of base channels of 100x50x6mm as required and with following incoming and outgoing switchgear with protection, metering etc. complete as required and as per specification and schematic diagram. |
| 762 | 6 WAY TPN-DB LDB |
| 763 | 12 WAY SPNGR Floor |
| 764 | EARTHING SYSTEM |
| 765 | Chemical earthing 17,2mm dia 3 mtr long with 50kg BFC CompoundWith brick workchamber 300 x 300mm |
| 766 | 25 x 6 mm G.I. |
| 767 | 25 x 3 mm G.I. |
| 768 | 8 SWG G.I earthwires |
| 769 | 8 SWG Cu earthwires |
| 770 | Add Carryin Charges |
| 771 | Add Side Development |
| 772 | Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.) |
| 773 | Clearing Grass and Removal of Rubbish |
| 774 | Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.) |
| 775 | Excavation in ordinary rock by manual means (Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with in all lifts and leads upto 1000 metres ) |
| 776 | Bankingexcavated earth in layers not exceeding 20 cm in depth breaking clods, watering, rolling each layer 1/2 tonne roller or wooden or steel rammers and rolling every 3rd and topmost layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide bunds etc. lead upto 50 m and lift upto 1.50 m. |
| 777 | Add Septic Tank(100 User) |
| 778 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t |
| 779 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 780 | Providing and laying cement concrete 1 : 3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering ina) Foundations and plinth |
| 781 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 782 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 783 | a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 784 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 785 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 786 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 787 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 788 | b) Tar/TMT Steel |
| 789 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 790 | 40 mm thick red oxide flooring, under layer of 30 mm thick cement concrete 1 : 2 : 4 (1cement: 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) & top layer of 10 mm thick plaster of cement red oxide mix (using 3.5 kg of red oxide of iron per 50 kg of cement) 1 : 3 (1 cement red oxide mix : 3 coarse sand) finished with a floating coat of neat cement red oxide mix of same proportion. |
| 791 | Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3coarse sand) finished with a floating coat of neat cement, including rounding of junctionswith floor. a) 18 mm thick |
| 792 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 793 | a) 100 mm dia |
| 794 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft andSW drain pipe 100 mmdia 1.80 m long complete,as per standard design. |