| 1 | Demolition Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as speicified and directed. |
| 2 | M/L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in 1:6 complete all as speicified and directed. |
| 3 | Taking down cement plaster or cement lime plaster on brick or stone walls etc.Including raking out joints ,hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 4 | Rendering 10mm thick on fair faces of brick work or concrete surfaces in Cement mortar 1:3 and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L white wash as in celing three coats on new surfaces complete all as specified and directed. |
| 6 | M&L white wash as in celing 2 coats incl complete removal of old treatmentsurfaces complete all as specified and directed. |
| 7 | M & L rendering 15 mm thick in cement plaster 1:4 on fair faces of brick wk or concrete surface finishing the surface even and smooth without using extra cement .WPC usedas per instruction of manufacturer. (Note:- WPC shall be measured & paid seperately.) |
| 8 | M&L for preparing new suface and applying two coats of cement based paint over a coat of primer complete all as speicified and directed. |
| 9 | M&L for preparing old surface and applying two coats of cement based paint complete all as specified and directed. |
| 10 | Material & Labour for applying Two coats on of 100% Premium acrylic exteriyer emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as speicified and directed. |
| 11 | Supply only Integral waterproofing compound complete all as speicified and directed.. |
| 12 | M & L rendering 15 mm thick in cement plaster 1:6 and finished even and smooth without using extra cement complete all as speicified and directed. |
| 13 | M & L for preparation of old wooden surface exceeding 10 cm width or girth and apply two coat of synthetic enamel paint complete all as specified and directed. |
| 14 | M&L non skid / parkingtiles 10 mm thick(square/ rectangular) polished, area of each tiles n. exceeding 0.36 sqm, infloors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 15mm thick screed bed in CM 1:4complete all as speicified and directed. |
| 15 | M & L for glazedceramic coloured tiles 300x600 x 7to 8 mm , with colour & design as per dirceted by Engr in charge, fixed in verticle surface (ht up to 4.90 m using scafolding on own arranement) pointed in white or colour cement to match rendering 10 mm thick in CM 1 : 4scred bedfor fixing tile complete all as speicified and directed. |
| 16 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to including grinding and polishingover 15 mm cement screed base . Incl mirror polishcomplete all as speicified and directed. |
| 17 | M&L Granite (of any type)Rounding to edges of stone slabs one edge,such as in steps, cooking platform, andother similar situationscomplete all as speicified and directed. |
| 18 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed . |
| 19 | Taking down Chowkhats or frames with shutters notexc 1.5 sqm complete all as speicified and directed. |
| 20 | Taking down Chowkhats or frames with shutters exc 1.5 sq. m but n exc 4 sq. m each complete all as speicified and directed. |
| 21 | Refixing in same opening Chowkhats or frames with shutters notexc 1.5 sqm complete all as speicified and directed. |
| 22 | Refixing in same opening Chowkhats or frames with shutters exc 1.5 sq. m but n exc 4 sq. m each complete all as speicified and directed. |
| 23 | M & L floor door stopper of aluminium alloy body and tongue, anodized with rubber washer at bottom fixed with screw to body and fixed to door shutter, over all length of cover plate shall be 140 mm complete all as specified and directed. |
| 24 | S & F Rolled Mild Steel Framed work as in doors or Gates of angle or other section confirming to Fe 410 -W (Gde- E- 250) quality- A with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and directed. |
| 25 | S & F in repair 30mm thick flush shutter, solid core construction with block board core and ply wood panels commercial type on both side complete all as specified and directed |
| 26 | M & F for second class hardwood glazed and skeleton door shutters 30mm thick, open rebated and prepared to receive glass gauge etc edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, gauge etc complete all as speicified and directed. |
| 27 | S & F sheet glass, 4 mm thick tinted shade ordinary qualityand glazing with oil putty/rubber gasket in squares andcomplete all as specified anddirected. |
| 28 | S & F in repairs stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as speicified and directed. |
| 29 | S&F Aluminum anodised barrel tower bolt of extruded section and fixed 125 mm long complete all as specified and directed. |
| 30 | S&F 250mm aluminium alloy, anodised,sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixingboltts and sliding bolts of extrude section or cast aluminium complete all as specified and directed . |
| 31 | S&F ijn reapairs Butt hinges, heavy weight, cold rolled mild steel, and fixed 100mm long complete all as specified and directed . |
| 32 | S&F in reapairs Butt hinges, heavy weight, cold rolled mild steel, and fixed 75mm longcomplete all as specified and directed . |
| 33 | S&F 110/100mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 34 | S&F 110/100mm PVC (SWR) bends any radius complete all as specified and directed. |
| 35 | S&F 75 mm PVC (SWR) bends any radius complete all as specified and directed. |
| 36 | S&F 75 PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 37 | Taking up or down steel tubing & connection incl cleaning for refixing or removal from site for 15 mm dia pipe complete all as speicified and directed. |
| 38 | M & L for GI Tubingmedium grade\" 15 mm, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as speicified and directed. |
| 39 | M & LBoulder pitching, laid dry, hand packed tightly complete all as speicified and directed. |
| 40 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed by Engr-in-Charge. |
| 41 | M&L for PCC1:4:8 type D-2 using 40mm graded stone aggregate , as in foundation,filling & mass concrete as in sub base to floor etc complete all as specified and directed by Engr-in-charge. |
| 42 | M & L for 75mm ThickCement concrete type C-1, 1:3:6 (20mm graded stone aggregate) in Plinth Protection etc. complete all as specified and directed by Eng-in-Charge. |
| 43 | M&L for providing75 mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge. |
| 44 | Demolition of cement concrete (reinforced ) of any description and in any position compete all as specified and directed. |
| 45 | M & L slabs for chajjas & supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck, slabs and in shelves and the like 1:2:4 type B-1, using 20 mm graded stone agg, in covers slabs including formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by the Engineer-in-Charge. |
| 46 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with selftapping screws complete all as speicified and directed. |
| 47 | M&L mild steel deformed TMT bar 10 mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge |
| 48 | Providing precast cement concrete in quoin banch seating of lemgth approx 2.00m width 0.75m with precast leged both side as approved by GE/ AGE |
| 49 | M & L preparation of roof treatment with APP polymeric water proofing water membrane all as given below :-(a) Taking down existing water proofing treatment , brick tiles and cleaning roof surface by washing and rubbing etc and removing retrieved material to a distance n.exc 500m where directed.(b) M & L for plastering 10mm thick in CM 1 : 3 using 100% coarse sand on roof surface including water proofing compound as per manufacturers instructions and as directed by Engr-in-Charge.(c) Applying a coat of bituminous primer conforming to IS : 3384 - 1986 @ 0.40 Ltrs/Sqm and allow to dry.(d)M & L for laying 4 mm thick APP modified polymeric water proofing membrane having weight 3.2 - 3.5 Kg/Sqm on prepared surface as per manufacturers instructions and over laps 10 cm and 15 cm longitudinal and traverse directions respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners.The membrane shall be torched into groove on verticle plane and groove sealed with cement mortar 1:3.(e)Applying two coats aluminium paint over membrane @ 1.20 Kg/Sqm and all as per specification and directed by Engr-in-Charge. |
| 50 | M&LPCC 1:2:4 type B-2 using 40mm graded stone aggregates as in roof padding etccomplete all as speicified and directed. |
| 51 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |