| 1 | Demolition of Brickwork or stone/ boulder masonry as in drain wall, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles. |
| 2 | M&L brick work with fly ash bricks (FASB) conferming to IS 12894, of strength M-10 straight or curved on plan exc 6m mean radius built cement mortar 1:6 complete all as specified and as directed. |
| 3 | M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified. |
| 4 | Taking down cement plaster on brick or stone walls etc incl racking out joints hacking for key and scrabbing down with water etc. complete all as specified and as directed. |
| 5 | M & L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 6 | M & L for preparation of new plastered surfaceandapplying two coat ofoil bound distemper on walls over a coat of Birla/JK wall putty omplete all as specified and as directed. |
| 7 | M & L preparing surfaces of wall by complete removal of existing treament andapplying two coat of oil emulsion distemper on walls over Birla/JK wall putty complete all as specified and as directed. |
| 8 | M & L for preparation of new plastered surface and applying two coat of cement base paint over a coat of alkali resistant priming paint on external surface etc complete all as specified and as directed. |
| 9 | M & L for complete removal of existing treament andapplying two coat of cement base paint over a coat of alkali resistant priming paint on external surface complete all as specified and as directed. |
| 10 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame)exe 1.5 Sqm but n exc 4 Sqm each etc complete all as specified and as directed |
| 11 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exe 1.5 Sqm each complete all as specified and as directed. |
| 12 | S&F Anodised aluminium frame for doors, windows, partition .ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 13 | M&L for powder coated anodised aluminium door shutter fabricated out of aluminium section 1.60mm thick two side openable with top rail and stiles of size 83x44mm, lock and bottom rail of size 100x44mm, (two panels) with and including 5 mm thick plain colour PVC sheet (Rajshree make) and5 mm thick ordinary sheet glass duly covered with tinted solar control film, including jointing cleats, glazing clips, rubber packing, aluminium anodised snap beading, screws, anodised aluminium fittings such as hinges (B-21) handles (disc type), tower bolts (200mm long), locking device with duplicate keys complete all as specified and directed. |
| 14 | S&F Anodised aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. fittings complete all as specified |
| 15 | S&F Sheet glass 4.8 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 16 | S&F Sheet glass 4.8 mm thick, ordinary quality and glazing with oil putty in squareexc 0.5 sq. m in each pane complete all as specified and as directed. |
| 17 | S&F 18/19mm thick prelaminated particle board interior grade prelaminated both side with decorative choice laminations and other side balancing white lamination fixed with screws to timber frame work etc complete all as specified and directed |
| 18 | S&F galvanised mild steelwire cloth 0.63 mm nominal dia of wire and average width of apperture 1.40mm and fixed with stainless steel staples in steel/wooden/aluminium frames complete all as specified and as directed by the Engr-in-Charge. |
| 19 | S&F for aluminium die cast body door closer hydraulically regulated designation No 3 universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 Kg and fixed in repair complete all as specified and as directed. |
| 20 | S&F framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders ; framed balusters; walk ways; railings; framework of watertanks and similar work conforming to Fe 290. Gde-E-165 complete all as specified and as directed. |
| 21 | M&L, preparing for new /old steel surfaces and applying two coats of synthetic enamel paint over one coat of rex oxide primer over 10 cm width or girth complete all as specified and as directed. |
| 22 | M&L for prepartion of old wooden surface and applying one coat of synthetic enamel paint on any description not otherwise described over 10 cm width or girth etc complete all as specified and as directed |
| 23 | M&L for Vitrified ceramic tiles 10mm thick (square/rectangular) polished area of each tile notexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchto floor etc complete all as specified and directed. |
| 24 | M&L for light shade vitrified ceramic tiles 10 mm thick (square / rectangular) polishedarea of each tile exceeding 0.18 sqm but not exc 0.36 sqm, in Vertical surfaces such as skirting, dado etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match to floor etcetccompleteall as specified and as directed. |
| 25 | S&F SS curtain rod 25mm dia grading H-304 with fancy knob type ends and brackets complete all as specified and as directed by the Engineer-in-charge. |
| 26 | Demolition of cement concrete (unreinforced) in ground floors and paving n. exc 15 cm thickness below or above ground level complete all as specified and as directed. |
| 27 | M&L 40 mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate)as infloor complete all as specified and as directed. |
| 28 | M&L for cement concrete type B-1 ,1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 29 | Demolition of wall and ceiling boards fibre pulp insulation etc or insulation boards/slabs/blankets any thickness including cover fillets, complete all as specified and directed. |
| 30 | S&FFalse ceiling4 mm thick HPSC pre-prime non asbestos fibre cement building board ( size 600mm x 600 mm/ 595 mm x595 mm ) decorative finish fixed with clips and screw includingpowder coated galvanised MS grid frame work false ceiling of ( Main Tee size 32mmx24mmx0.50mm cross tee 24mmx24mmx0.30mm ) and with slot for fixing including suspended with 2mm dia. GIwirehangers fixed with steel dash through fasteners from purlineof the roof complete all as specified and as directed. |
| 31 | M&L PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete as sub base of floor complete all as specified and as directed. |
| 32 | M&L forprecast machine pressed cement concrete chequered tiles of size 25cm x 25cm x 22 mm thick conforming to IS : 1237-1980 shall be laid in neat cement slurry over and including 15 mm thick cement mortar screed in 1:4 and joints between the tiles to be filled tile grout or equilent complete all as specified and directed. |
| 33 | M&L Cement concrete type D2, 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified. |
| 34 | M&L for machine pressed precast concrete interlocking paver block Glossy finishes any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade and fixed with grey cement and pigment over andincluding 50 mm thick sand cussion complete all as specified and directed. |
| 35 | Demolition of floors (other than ground floors), beams staircases, landing, beam, & similar suspended work Cement concrete (reinforced) complete all as specified and directed |
| 36 | M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 37 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in flat rough finished surface of concrete complete all as specified and as directed. |
| 38 | M&Lfor mild steel TMT bars ,10mm dia and over, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 39 | All as above item No-38 but 6 to 8 mm dia TMT bar for strupps complete all as specified. |
| 40 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed. |
| 41 | S&F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 42 | S&F pre- painted galvalume aluminium zinc coating GI based plane steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 43 | M & L for cutting holes into or through brick walls built in cement mortar andmaking good in cementmortar 1:3 or cementconcrete 1:2:4 type B-l as required complete all as specified. |
| 44 | M&L for 75mm thick cement concrete type C-1, 1:3:6 (20mm graded aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed. |
| 45 | Excavating in over area not exc 1.5m wide and n. exc 1.5m in depth for foundation etc or manholes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil all as specified. |
| 46 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in filling & mass concrete in floor complete all as specified and as directed by Engineer -in-charge. |
| 47 | M & L for providing precast cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) as in louvers and jallies, 25 mm thick ( measured solid), set in cement mortar 1:4 including all mouldings etc complete all as speciifed and as directed. |
| 48 | Returning filling in including spreading, levelling, watering and well ramming in layer nexc 25 cm in soil complete all as secified and directed |
| 49 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as secified and directed. |
| 50 | M&L for rendering 15 mm thick on faces of brick work or concrete surfacesCM 1:6 and finishing the surface even and smooth without using extra cement completeall as specified and directed. |
| 51 | S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete steel confirming to Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 52 | Taking down carefully copper/ aluminium point wiring (light, fan, socket, or power) complete fitting such as switches, ceiling roses pendants, regulators, sockets, light fitting ceiling fan etc to be measured seperately ) removing materials for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperatly) and making good disturbed surface of walls floors etc all as specified and directed. Note-Responsibility after taking down fan/exhaust fan keep in safe custody of contractor and refix the same afterbefore completion of work the rate of same deemed to be included in the item quoated rate. |
| 53 | Taking down carefullyexisting wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size anycapacity fromboards completeall as specified and as directed. |
| 54 | Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed. |
| 55 | M & L for concealed point wiring One light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.6mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dollywith3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green multi stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed. |
| 56 | S&F switch pianoflush button type 5 Amp single pole one waycomplete all as specified and asdirected. |
| 57 | S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittingscomplete all as specified as directed |
| 58 | S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified as directed. Make C&S Cat No LTHPLEDLAMP7W/B22 or equivalent make as specified in Appndx\"B\" to PS . |
| 59 | S&F ceiling rose,surface polycarbonate63 x50mm three terminals completeall as specified and asdirected. |
| 60 | M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 1.5 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 20 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 61 | S&F sheet metal enclosure double doorconcealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 8 ways 240 V complete all as specified and as directed . |
| 62 | S&F MCB single pole and neutral 40 Amp / 63 Amp 240 V ,10KA , \"C\" series, complete all as specified and as directed with copper lugs |
| 63 | S&F MCB single pole 6 to 32Amps 240 V,10KA, \"C\" series,complete all as specified and as directed |
| 64 | Supply and fixing in repair 22 W LED 6000kDecorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 28watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and directed by Engr-in- Charge. |
| 65 | Supply and fix LED 35/36 W building security light fitting,5700 K energy saving & environmental friendly long life versatile pressure die cast aluminiumIP 66.road way luminare with high power LEDs as light source and electronic driver suitable for pole dia 35 mm including 35 mm dia light grade tube bracket ,bend to shape 1.80 mtrlength with two nos of clamps of size 50mm x 6mm with nuts and bolts,washers etcincluding connection with 1.5sqmm threesinglecorePVC insulated and PVC sheathed cable stranded copper cable upto ceiling rose and fixing on walls/pole complete all as specified and directed. |
| 66 | Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with gaivanised steel or strip and overall PVC sheathed, 10 Sqmm 2 core ISI marked as per IS 7098(Part 1) including connecting on LT OH line/LT panel/DB with suitable lugs, glands, binding wire etccomplete all as specified and directed by Engineer-in-Charge. |