| 1 | Demolition of cement concreteand paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 2 | Taking down chowkats or frames with shutters (without taking off shutter from frames) area not exc. 1.5 sqm eachincluding making good the disturbed surfaces to match with adjoining surfaces etc complete all as specified and as directed |
| 3 | Taking down chowkats or frames with shutters (without taking off shutter from frames) area exc. 1.5 Sqm but n exc 4.0 Sqm each including making good the disturbed surfaces to match with adjoining surfaces etccomplete all as specified and as directed |
| 4 | M&L forPlain cement concrete(1:4:8)type D-2 using 40mm graded stone aggregateas in 100 mm thick sub base topath etc completeall as specified and as directed |
| 5 | M&L forPlain Cement concrete(1:2:4)type B-0 using 12.5mm graded stone aggregateasin 25 mm thick levelling course of flooing etc complete all as specified and as directed |
| 6 | M&L for PCC(1:3:6)type C-1using 20 mm graded stone aggregates as in75 mm thick plinth protectionfinished even and smooth without using extra cement including joints filling with sealing compound Grade \"A\"complete all as specifiedand directed. |
| 7 | M& L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqmin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including15 mm thick screed bed in cement mortar (1:6) includingdismantling floor, hearth tiling etc complete all as specified and as directed |
| 8 | M& L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqmin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including10 mm thick backing coat in cement mortar (1:4) includingdismantling wall tiling etc complete all as specified and as directed |
| 9 | M& L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including15 mm thick screed bed in cement mortar (1:6) includingdismantling floor, hearth tiling etc complete all as specified and as directed |
| 10 | M&Lfor Sand filling under floors or in foundations including watering and consolidation etc complete all as specified and directed . |
| 11 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and as directed . |
| 12 | M&L for Glazed ceramic coloured tiles 350X 250X 7mm / 450X 350X 7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over &includingbacking coat 10 mm thick in CM(1:4) including dismantlingwall tiling etc complete all as specified and as directed |
| 13 | M&L for Pre-cast Cement concrete(1:3:6) Type C-1 using20 mm graded stone aggregates as in solid block masonary exc 10 cm in width and setting in CM(1:6 ) including demolition of brick Work / Stone Masonry/PCC block masonry built in cementmortar of any description all as specified and directed. |
| 14 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work / stone / concrete surface etc complete all as specified and as directed |
| 15 | M&L for rendering 10 mm thick CM (1:6) on other than fair faces of brick work or concrete / stone masonrysurface finsihed even and smooth without using extra cementetc complete all as specified and as directed |
| 16 | M&L for rendering 10 mm thick in CM (1:6) first layer and rendering 5 mm thick second layer in CM(1:4)mixed with water proofing compound as per manufacture instruction on fair faces of brick work or concrete surface finished even and smooth without using extra cement etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately |
| 17 | M&L for Plain cement concrete(1:2:4) type B-0using 12.50mm graded stone aggregate as in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs/Chajjas and the like including weathering, slightly rounded or chamfered angles and throating as directed |
| 18 | Supply only water proofing compound (Liquid), ISI marked, complete all as specified and as directed. |
| 19 | S&FPressed steel frame of profile size 125 X 60 mm for door with one ore more rebate made of 1.25 mm thick M S sheets includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 20 | S&FPressed steel frame of profile size 105 X 60 mm for door with one ore more rebate made of 1.25 mm thick M S sheets includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 21 | M&L for Plain cement concrete(1:3:6)type C-1 using 20mm graded stone aggregateas in hold fast block and fillingof pressed steel chowkatetc complete all as specified and as directed |
| 22 | M&L for Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and as directed |
| 23 | S&F Steel window Box type double side shutters (Windows side hung type , Ventilators top hung)pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, Shutters box type made out of CRC Sheet of 40x20x1.0mm , windows & ventilator shutter fixed made of glass andgauge fixed with box type hinges, Aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, Telescopic stays,etc complete all as specified including12mm square guard bars / grill welded with steel frame (100c/c horizontically) all as shown in CE Chennai Zone TD drg No 539 and as specified and directed .NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard/Grill,beading, fittings such as handles,hinges,Telescopic stays, locking arrangements and fixing of glass and wiremesh etc. (ii) 4 mm thick sheet glass and stainless steel wire mesh 0.36mm dia and 1.4mm width of aperture deemed to be included in quoted rate. |
| 24 | S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed |
| 25 | S&FFlush door shutter 35mm thick, solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed |
| 26 | S & F Glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed |
| 27 | S & FSolid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete as sepecified and directed (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 28 | S&F factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on backface etc. complete all as specified and as directed. |
| 29 | S&FAluminium anodised towerbolt 200 mm long of extruded section etc complete all as specified and as directed |
| 30 | S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed |
| 31 | S&FButt hinges 100 mm sizemedium weight, Stainless steel and fixed etc complete all as specified and as directed |
| 32 | S&FAluminium handle 150 mm size, cast type, anodised etc complete all as specified and as directed |
| 33 | S&FFloor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, length of cover plate 150 mm long etc complete all as specified and as directed |
| 34 | S&F in repair Vitreous china wash down water closet pan (pedestral Pattern) white, including connection to drain & or out going pipeand to flushing pipe, anti syphonage pipe, with & including Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified & directed |
| 35 | S&F in repairs vitreous china wash basin white, flat back, size 550 x 400mmincluding brackets, 32 mm bore waste stainless steel couplingand LDPE pipe 600 mm long complete all as specified and directed. |
| 36 | S&F in repair PVC flushing cistern with flush out valve low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets, etc complete all asspecifiedand as directed |
| 37 | S&F in repairBib taps Fancy type, Chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe 15mm dia bore or for brass ferrule etc complete all as specified and as directed |
| 38 | S&F in repairAngle / Stop / Concealed cock, Fancy type cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 15mm dia bore or for unions and fixed etc complete all as specified and as directed |
| 39 | S&F in repairs Health faucet, brass body with 1mtr stainless steelbraided tube & wall hookcomplete all as specified and as directed . |
| 40 | S&F in repairs Soap dish chromium plated brassfixed in wall as per manufacturers instruction complete all as specified and as directed .(Make :Prayag cat No BA-45 of Prayag or equivlaent make specified in P S ) |
| 41 | S & F in repairsbevelled edge mirror 600mmx450mm of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified & directed. |
| 42 | S&F in repairs stainless steel towel ringincluding fixing arrangement etc complete all as specified and as directed (Make Cat no BA-41 of Prayag or equlavent make specified in P S ) |
| 43 | S & FCPVC pipes20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors includingtaking down existing GI/CPVC pipe line etc complete all as specified. |
| 44 | S & FCPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors includingtaking down existing GI/CPVC pipe line etc complete all as specified. |
| 45 | S&F in repairs rotational moulded polythene water storage tank 1000 ltrs capacity(cylindrical vertical with closed top) triple layered, hoisted and fixed in position all as specified in SSR part Iincluding ball float valves 25 mm dia of bore high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball etc complete all as specified and directed |
| 46 | S & F in repairsGun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe 25 mm dia bore and including taking down old gate valve all as specified and as directed. |
| 47 | S&F PVC connection 600mm long 15mm dia with PTMT not etc complete all as specified. |
| 48 | S&F in repairs PVC (SWR) Multi floor trap75 mm dia outlet, plain with grating including jointing with solvent cement etc complete all as specified and as directed |
| 49 | S&F PVC, SWR pipes 110 mm dia, single socketed in any length with rubber ring joint laid in trenches or in floor etc includingdismantling of existing pipe line and fittings etc complete all as specified and directed |
| 50 | S&FPVC, SWR pipes 110 mm , single socketed in any length with rubber ring joint fixed on walls etc includinfdismantling of existing pipe line and fittings etc complete all as specified and directed |
| 51 | S&FPVC, SWR pipes 75 mmdia , single socketed in any length with rubber ring joint laid in trenches or in floors incl dismantling of existing pipe line and fittings etc complete all as specified and directed |
| 52 | S&FPVC(SWR) bends (any radius) 75mm dia etc complete all as specified and as directed |
| 53 | S&F in repairs PVC (SWR) vent cowls 110 mm dia bore complete all as specified and directed |
| 54 | M&L for preparation of wall surface with sand paper etc and applying wall care putty 1mm thick finish to smooth surface, one coat of primer and two coat of acrylic emulsion distemperetc complete all as specified and as directed |
| 55 | M&L for Preparing new /Old Previously untreated plastered surface of wallincluding filling the cracks etc with crack filling material as per manufacturers instructionsand Applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqmcomplete all as specified and as directed. |
| 56 | M&L for Preparation of old treated woodensurfaces of any description, over 10 cm in width or girth , and applying one coats of synthetic enamel paint etc complete all as specified and as directed |
| 57 | M&L for Preparation of oldtreated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint etc complete all as specified and as directed |
| 58 | S&F in repairs stainless steel decorative curtain rod of 25 mm bore with wood finishes (weight not less 400 gms per running meter) including fancy finale caps cap (02 nos in each curtain rod)etc complete all as specified and as directed |
| 59 | S&F in repair Brass Chromium Plated designer Bracket for curtain rod of dia 25 mm dia made out of stainless steelFlat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long etc complete all as specified and as directed |
| 60 | S&F Pre-painted galvatume aluminum zinc coating, 150AZ,GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall, fixed with self tapping screws etc including dismantling of asbestos cement roofing etc complete all as specified and as directed |
| 61 | S&F Pre-painted galvalume aluminum zinc coating, 150AZ,GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in ridges / valley to wall, fixed with self tapping screws incl dismantling of Ridges etc complete all as specified and as directed |
| 62 | Dismantling oftimber scantlingsunframed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed. |
| 63 | M&L for Mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410 -W (Gde- E- 250) quality-A etc complete all as specified and as directed |
| 64 | Dismantling ofwall and ceiling boards any thickness of any description including cover fillets complete all as specified and directed. |
| 65 | S & FFalse ceiling using E- grid suspended ceilinggrid system of gridsize 600x600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross Tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24mm x 3mm including4mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS No 14862-2000) fibre cement E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips, complete all as specified and directed. |
| 66 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed. |
| 67 | M & L for point WiringwithPVC insulated unsheathed FRLS cable1.5 Sqmm single core1100 volts grade multi strandedcopper conductor conforming to IS 694 drawn through and includingnon-metalic rigid PVC conduit with accessories concealed onwalls/ ceiling includingMS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for the followingall as specified and as directed :- |
| 68 | One light / fan point controlled by one switch |
| 69 | One 3 pin socket out let 5 Amps on independent board |
| 70 | One 3 pin socket out let 5 Amps on same board |
| 71 | M & L for Point WiringwithPVC insulated unsheathed FRLS cable 2.5 Sqmm single core1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and includingnon-metalic rigid PVC conduit with accessories concealed on walls / ceiling includingMS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including2.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 72 | Note for Item No 68 & 69 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring. (v) Cost of a cutting chases deemed to be included in the unit rate quoted |
| 73 | S&F in repairs LED batten with luminaires suitable for indoor applications 20 Watts capacity, 4 feet long with extruded aluminiumhousing & integrated LED channelwith all accessoriesall as specified and directed. |
| 74 | S&FSwitch piano, flush type, single pole one way 5Ampsall as specified and directed. |
| 75 | S&FStepped type electronic fan regulator flush Switch/socket type all as specified and as directed |
| 76 | S&FSwitch socketcombination2in 1 , 5 Amps flush type, 230volts all as specified and asdirected |
| 77 | S&F Switch socket combination 2 in 1, 3 pin 5 and 15 Amps,flush type universal all as specified and asdirected |
| 78 | S&F in repairsMCB SPN 240 volts 32/40 Amps, C curves complete all as specified and as directed |
| 79 | S&F in repairs MCB single pole 240 volts 10/16/20/32 Amps, C curves complete all as specified and as directed |
| 80 | S&F in repairs MCB Distribution board SPN 8 way, double door type, 240 volts with 200 Amps rated busbar allas specified and as directed. |
| 81 | S&FCeiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals, 230 volts all as specified and as directed |
| 82 | M&L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-Iand as specified or indicated and testing on completion includingearth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering pipe, wire mesh and lugs,test point complete all as specified and as directed including dismantaling old unserviceable earthing all as specified & directed.. |
| 83 | Supply and fixing in repairs LED bldg securitylight fitting30 Watts capacitywith pressure die cast housing along with prismatic polycarbonate difuser with IP 66protection including taking out old fittingscomplete all as specified and directed. |
| 84 | S&F in repairs GIBracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paintover a coat of red oxide primer including removing the old existing GIbracket from bldg complete all as specified and directed. |
| 85 | M & L forsub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run through suitable size of PVC casing capingall as specified and as directed.(Note : Three run of 6sqmm cable and one run of casing capping measured as one unit) |
| 86 | S&F in replairMCB TPN 415 volts 10 KA \"C\" curves, 63 Amps capacitycomplete all as specified and as directed |
| 87 | Excavation in trenches in hard/dense soil not exc 1.5 m wide and not exc 1.5 mtr in depth for laying of cables / erection of pole etc complete all as specified and as directed. |
| 88 | Returning, filling in trenches includingspreading leveling watering and well ramming in layers with soil not exc 25 cm thick in each layer complete as specified and as directed |
| 89 | Removing excavated soil to a distance not exc 50m and depositing 1.5 m above the starting point complete all as specified and as directed |
| 90 | M & L for sand cushioning with a layer of river sand under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed |
| 91 | S&L sub class \"B\" burnt bricks for cable protection all as per Para 19.75 of SSR Part-I complete as specified as directed |
| 92 | Suply & LayingXLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable 4 Core x cross sectional area 25 Sqmm (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including taking out the existing unserviceable cablecomplete as specified as directed |