| 1 | M&L for Complete removal of existing treatmentand applying two coats of OBD over a coat of alkali resistant primer on wall complete all as directed by Engineer-in-Charge. |
| 2 | M&L for applying two coats of oil bound distemper on Ceiling surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 3 | M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/ old decorated wall surfaces, in case of old decorated wall surfaces includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 4 | M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand papercomplete all as specified and directed. |
| 5 | M&L for preparation of old painted wood surfaces of any description having width/ girth execeeding 10cm and apply two coat of synthetic enamel paint complete all as specified & as directed. |
| 6 | M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and apply two coat of synthetic enamel paint complete all as specified and as directed. |
| 7 | Material and labour for repairing of soffits of slabs, chajja, facia and similar works by dismantling of loose/ disintegrated portion of RCC at any height (upto 10M) and in any sitution, including provn of support,formwork and welding of reinforcement and fixing in position and with provision of weld mesh, applying dubbing 1st coat of 20 to 25mm thick in CM 1:3 finished rough and finishing coat of 10mm thick in CM 1:3 finished even and smooth without using extra cementover and including cement slurry @ 3 kg/sqm, finished even and smooth to desired shapeand applyingtwo coats of weather proof exterior emulsion paint over a coat of arylic resistant primer to match with existing surfaces complete all as specified and directed.(weld mesh measured and paid sepatrtely)Note:- (i) Unit rate of this item includes the cost of scaffolding, formwork etc. and nothing extra shall be paid on account of variation in height. (ii) For payment purpose, the area of finished plaster in 2nd coat shall be considered. |
| 8 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 9 | M&L for rendering5 mm thick in cement mortar 1:3 as in ceiling and finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 10 | M&L for rendering10 mm thick in cement mortar 1:6 on walls and finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 11 | M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface, finishing even and smooth using extra cement incl Integral Waterproofing Compound (0.2 % or 100 ml per bag of cement) complete all as specified and directed. |
| 12 | M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered wall surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 13 | M&L for preparation of newly plastered surfaces ofwalls andapplying two coats ofdistemper-oil-emulsion over a coat of primer complete all as specified and as directed. |
| 14 | M&L for preparation of newly plastered surfaces ofceiling andapplying two coats ofdistemper-oil-emulsion over a coat of primercomplete all as specified and as directed. |
| 15 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for including removal ofdebriscomplete all as specified and as directed by Engr-in-charge. |
| 16 | Removal ofdamaged existng APP mambraneof roof including danmaged levelling concrete and rougheningsurfaces of concrete slab by picking, sweeping clean and washing down with water to remove dust etc and applying evenly cement slurry at the rate of 3kg / sqm over cleaned roof surfaces including removal ofdebriscomplete all as specified and as directed by Engr-in-charge. |
| 17 | S&F PVC/ rain water (SWR) pipes 150mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 18 | S&F PVC/ rain water (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 19 | S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110 mm/150mm PVC pipe complete all as specified and directed. |
| 20 | S&F PVC(SWR) bends, any radius of 110 mm bore without access door complete all as specified and directed. |
| 21 | S&F PVC(SWR) bends, any radius of 150 mm bore without access door complete all as specified and directed. |
| 22 | Material and labour for PCC 1:2:4 type BO (using 12.50mm graded stone aggregate) for roof,kerbs or mud stops,roundedor chamfered on eds etc including mixing of admixture fosroc SP 430 of M/S Fosroc chemical @ 250ml per 50kg of cement over existing roof and in padding concrete to maintain required slopecomplete all as specified and as directed by Engr-in-charge.Note:- WPC will be measured and paid separetly under respective item. |
| 23 | Supply only of admixture fosroc SP 430 ,Dr fixit Chemical all as specified and as directed by the Engineer-in-Charge. |
| 24 | Material and labour for screed bed layer 10 mm thick in CM 1:4 onconcrete surfaces of roof, mixed with integral water proofing compound @ 3% by weight ofcement,finished even and smooth without using extra cementcomplete all asspecified and directed. Note:- WPC will be measured and paid separetly under respective item. |
| 25 | Supplyliquidwater proofing compoundmake Fos roc or equivalent make |
| 26 | M&L Water proofing treatment on \"Non approachable / non accessible and approachable roof\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete (i) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm(ii)Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces complete all as specified and directed. (iii) Laying evenly over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction complete all as specified and directed.(iv) Applying two coats of bituminous aluminium paintincluding preparation complete all as specified and directed. |
| 27 | Supply and Application of 7 Layer Solar IR Heat Reflective Waterproofing Coating System on leaking concrete surface by thorough surface preparation to remove dust, dirt, molds etc using steel wire brush/power brush, high pressure water jet as applicable, opening the cracks, and then applying the entire surface with one absorption coat of nano modified, UV resistant non-styrene elastomeric clear coating having min. 50% solids (i.e. Thermacool WP51) then filling the cracks with waterproofing putty and then overcoating with a sandwich waterproofing Coat of Thermacool WP51 + Cement mixture having non-woven fibre mesh of min. 80 GSM followed by an additional elastomeric waterproofing coat (i.e. Thermacool WP51 + cement) having +450% Elongation, Tensile Strength min. 2.2 MPa and then top-coating with 2 Coats of pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) Solar IR Heat Reflective coating conforming to BIS STD IS 17218:2019 (i.e. Thermacool 0.3C) with pull off adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 coat, dft 100 - 120 microns using brush, roller, airless as applicable or equivalent make or guidelines of similar product mentioned below. The application to be done by manufacturer approved applicators only. |