| 1 | Dismantling of Wallandceilingboards(fibre, pulp, insulation, etc.) or insulationboards/slabs/ blankets, any thickness, including cover fillets. |
| 2 | S & F Anodised aluminium snap gridframe work for false ceiling allas specified |
| 3 | S & F Hangers 6 mm dia. G.I. (upto1200mm length) adjusting levelfixed to roof slabs by means ofceilling cleats made out of G.I. flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm longcomplete all as specified. |
| 4 | Providing and fixing 10mm thickplaster of paris ceiling (Gypsumanhydrous) to flat surface over 2ndclass soft wood fillets, or metal framework and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately). |
| 5 | M&L for 6mm thick plywood, (5 Nos of ply)grade BWR, type BB, fixed with nailsto timber framework. In wall partitions. |
| 6 | M&L for prepration of new wooden surfaces exc.10cm in width or girthand applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 7 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, unframed work |
| 8 | M & L for Second class hard-wood in scantlings, clean sawn timber unframed and fixed. |
| 9 | M & L for Preparation of old painted surfaces of walls and applying two coats of Oil bound distemper complete all as specified and directed. |
| 10 | Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint (Camouflage pattern) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacescomplete all as specified and directed. |
| 11 | Taking down carefully aluminium point wiring (light, fan, socket or power) complete and making good disturbed surfaces of walls, floors, etc. all as directed.including taking down fittings such as switches, ceiling roses, regulators, sockets,lamp holders etc. |
| 12 | M&L for point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC Conduit of sizenot less than 20mm on surface of wall including provn of PVC box/modular metal flush box of suitable sizefor mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed,1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all asspecified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps. |
| 13 | All as per above Item no.12 but withOne 2/3 pin socket outlet 5Amps on independent board. |
| 14 | All as per above Item no.12 but withOne 3 pin socket outlet 5 Amps on the same board with other switches. |
| 15 | All as per above item No 12 above but one switch socket combination 15 Amps on independent board with cable 4.0 sq mm size and earth wire 4.0 sqmm . |
| 16 | Supply and fix in repair Modular switch 1way 6A,1module. |
| 17 | Supply and fix in repair Modular switch 2 way 6A,1module. |
| 18 | Supply and fix in repair Modular switch 1way 16A,1module. |
| 19 | Supply and fix in repair Modular socket, 6A-2/3 pin combined 2 module. |
| 20 | Supply and fix in repair Modular socket, 6A/16A-2/3 pin combined 2 module. |
| 21 | S&F ceiling rose surface bakelite3 terminals 65x50mm all as directed. |
| 22 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as specified. |
| 23 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete as specified. |
| 24 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 25 | Supply and fixing round /square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 26 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete as specified. |
| 27 | S&F in repair Lamp holder angle type made ofPVC/Polycarbonate with back plate. |
| 28 | S&F LED Lamp 9W B22 Type all as specified and directed. |
| 29 | S&F decorative wall light ,gold fnish with cogac hammered glass diffuser suitable for 7.5 W LED filament lampNote:Havells or equivalent in other made. |
| 30 | Supply only modular white cover plate with frame, 1 module ISI markedcomplete all as specified and as directed. |
| 31 | Supply only modular white cover plate with frame, 2 module ISI markedcomplete all as specified and as directed. |
| 32 | Supply only modular white cover plate with frame, 3 module ISI markedcomplete all as specified and as directed. |
| 33 | Supply only White cover plate with frame, 4 module ISI markedcomplete all as specified and as directed. |
| 34 | Supply and fixWhite cover plate with frame, 6 module ISI markedcomplete all as specified and as directed. |
| 35 | Supply onlyWhite cover plate with frame, 8 module ISI markedcomplete all as specified and as directed. |
| 36 | S&F in replacement, sheet metal enclosuredistribution box suitable for MCB\"S8 way SPN with 200 Amps rated bus bar , 240 volts with 200 Amps rated bus bar double door complete including connecting up all as specifiedand making good distrubed surface. |
| 37 | S&F in replacement MCB Single pole, 240 volts 5 to 32 Amps 10 KA rupturing capacity, C series |
| 38 | S&F in replacement MCB Single pole & neutral 240volts 20 to 32 Amps, 10KA rupturing capacity, C series |
| 39 | S&F in replacement MCB triplepole415 volts 25 to 63 Amps 10KA rupturing capacity, C series. |
| 40 | S&F in replacement MCB TPN415 volts 40 to 100 Amps 10KA rupturing capacity, C series. |
| 41 | M&L for replacement ofsub main wiring withtwo single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sq mm drawn throughsuitable size of non-metallic PVC rigid conduit with4 sqmm copper conductor cable as earth conductor of 4.0 sq mm and conduit accessories fixed up in surfaceincluding connecting up completeincluding taking down old unserviceable submain wiring all as specified and directed. Note :Two Run of PVC wire and one run of earth wire one run of conduit will be measured as one length. |
| 42 | M&L for replacement of sub main wiring withtwo single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sq mm FRLSH drawn throughsuitable size of non-metallic PVC rigid conduit with6 sqmm copper conductor cable as earth conductor of 6.0 sq mm FRLSH and conduit accessories fixed up in surfaceincluding connecting up completeincluding taking down old unserviceable submain wiringall as specified and directed. Note :Two Run of PVC wire and one run of earth wire one run of conduit will be measured as one length. |
| 43 | M&L for replacement of submain wiring alongwith earth wire with 4x10.0 sq. mm +1x10.0 sq. mm earth wire sq mm sizes of FRLS foris PVC insulated copper conductor, single core cable in existing /surface/recessed as required in PVC Conduitincluding taking down old unserviceable submain wiring.Note :Four Run of PVC wire and one run of earth wire one run of conduit will be measured as one length. |
| 44 | Taking down Exhaust fan of any size type and make after disconnecting the electrical connections ,cleaning, servicing , greasing removing and replacing all theunserviceable spare ,painting with two coats of synthetic enamel paint by means of suitable spray gun after cleaning and prepairing the suface including writing the MES No. ,fixingthe same back to the original location all as directed. Note for item No. 35 to 38 : (i) All the replacedspare for unserviceable spares will be measured and paid separately (ii) The rate quoted shall be deemed to include the cost of painting and minor spares such assplit pin , screws washers etc. |
| 45 | Supply only ball bearing suitable for exhaust fans 300/450/600 mm dia sweep. |
| 46 | Supply only Capacitor 4.0 mfd for exhaust fans. |
| 47 | Supply only gun metal bush suitable for ceiling fans of 1200/1400/1500mm sweep. |
| 48 | Supply only twin core flexible wire 1.0 Sqmm for connecting up ceiling fans, exhaust fans/wall mounting fan etc. |
| 49 | Taking down old burnt out copper winding wire from exhaust fan of any sweep and rewinding by using the same gauge of copper wire super enameled including heating and varnishing,cleaning, servicing,greasing ,refixing at siteand testing for smooth functioning complete all as specified & directed. |
| 50 | Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and conmmon salt filling in alternate layers connected to and including GI earth wire 4.0 mm dia upto 7.5 mtr by means of bolts, nuts, check nuts and washers, and protected by light grade 20 mm dia and connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with P C C 1:2:4 Type C2 (including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 metre and testing after completion including dismantling of old unserviceable earthing all as specified and shown on plate No 3 of SSR Part-I 2009 |
| 51 | Repair / servicing including trouble shooting /repair of geyser 25 to 50Ltrs capacity checking of serviceability of individual parts such asthermostat, heating element, pressure release valve, inlet/outlet connections etc, replacing worn-out fasteners and defective components and testing including taking down the geysers and refixing the same after repairs.Note : Spare parts including replacement will be measured and paid separately under relevant item.Rate quoted shall includereplacement of worn-out fasteners. |
| 52 | Supply only heater coil of geyser all 1.5 KW as per existing make / model / sizeconforming to relevant IS. |
| 53 | All as per item No 52 above but 2.0 KW |
| 54 | Supply onlythermostat for any type /make/capacityof geyser . |
| 55 | Supply only PVC flexible connection of 15 mm dia 600 mm longwith check with new one suitable forcold/hotwater connection of geysers |
| 56 | Supply only Indicator Lamp of RED / GREEN Suitable for Water Heater |