| 1 | Day to Day monitoring of CCTV Surveillance Network system installed at Swaran Jaynti Park,HD-5 office complex Rohini i/c upkeep of recording, data process & Maintenance as per Inventory, additional terms and Conditions attached. |
| 2 | Comprehensive Annual maintenance contract of EPBAX system make Kanishka model 6/16 for 12 line extension complete with instruments,UPS,MDF,Related cabling etc. complete as required at site. |
| 3 | Maintenance of IEI, fans and other Electrical installation at office building of Horticulture Div-5 /DDA as per inventory attached by deploying staff as per terms and conditions attached. |
| 4 | Supplying Replacement Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc complete as required. (a)16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen:1/4/8/9/16 |
| 5 | Supplying replacement Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc.(a)4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) |
| 6 | Providing & Replacement of CCTV bullet Camerawith 1/3\" Progressive scan CMOS, lens 6 mm, 3 MegaPixel, HD 1080/720pReal timeVideo Recording, True day/Night, IP 66 rating, metallic body, IR range upto 40-50 Mtr. with power supply, suitable stand, extra safety housing i/c fixing at suitable place etc. complete as required i/cold camera rebate. |
| 7 | Supply ,Replacement , commissioning & testing of POE Switch 16+2 Port Gigabit Unmanaged PoE Switch | 0/100/1000 Mbps gigabit Ethernet port 2 SFP port 250m PoE Switch + 2 SFP Uplink in offers 150 watts available Poe Flow control for protection against data loss Maximum distance of 250m Light protection6KV etc. as required. |
| 8 | Supply , Replacement , commisssioning & testing of 6 TB Surveilllance Systems Internal Hard Disk Drive for storage of surveillance data complete etc. as required i/c rebate for old |
| 9 | Supplying, Replacement, Installation, Testing andcommissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.a) 1 run of cable |
| 10 | 4.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 11 | 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 12 | Supplying and replacement following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2 pair |
| 13 | Supplying and replacement following piano type switch/ socket on the existing switch box/ cover including connections etc. as requireda)5/6 Ampswitch |
| 14 | b)3 pin 5/6 A socket outlet |
| 15 | c)-15/16 A switch |
| 16 | d)6 pin 15/16 A socket outlet |
| 17 | Supplying and replacement 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a)Single Pole |
| 18 | b)Double pole |
| 19 | c)Triple pole and neutral |
| 20 | Supply, replacement, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulator for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.a)1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 21 | LED Batten light (System lumen efficacy ≥120 <135lm/Watt) Supplying, replacement, Testing & Commissioning ofLED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.\ System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) (a)18- 22 Watt |
| 22 | S/F and Replacement of Desert Cooler 18” size made of MS Sheet 18/20-SWG including Pump for Water Lifting Capacity up to 1.5 mtr., 3-Speed Cooler Fan Motor, Side Panel, Front Grill, ON/ OFF Rotary type Switch, Wood-Wool Pad, 3C Cu. readymade Lead with ISI 5 Amp 3-Pin Topi/c Rebate for Dismantle Material complete etc. as required. |
| 23 | Supply,replacement, Testing, Commissioning of 12-Volt 7 AH Sealed Maintenance Free Dry Battery make Exide/Panasonic/Amaron complete connection etc. as required i/c Rebate for Old Battery. |
| 24 | Providing & Replacement ofbasic Intercom/Telephone instrumentCorded Landline Phone with inbuilt feature ofcaller ID Display, Speaker Phone, Function complete etc. as required i/c old equipment rebate. |
| 25 | Cleaning &refilling of ABC type Fire Extinguishercapacity -4 kg.dry powder type Suitable for use with fires involving ordinary combustibles, flammable liquids and energized electrical equipment. i/c hose pipe, nozzle& indicator & relocating complete etc. as required. |
| 26 | Cleaning &refilling of Co2type Fire Extinguishercapacity -4.5 kg. Sodium bicarbonate Powder for fire fighting against light and ordinary fire hazard i/c hose pipe, nozzle & indicator & relocating complete etc. as required. |
| 27 | Supply, Installation , commissioning & testing of ABC type ISI marked Fire Extinguisher Capacity 4 kg. Suitable for use with fires involving ordinary combustibles, flammable liquids and energized electrical equipment. I/c rebate for old |