| 1 | Demolition of brick work Brickwork or stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 2 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition)roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. |
| 3 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | Taking down shutters of any description n exc 1 sqm each leaf and refixing in same opening complete all as specified and directed. |
| 5 | Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each leaf and refixing in same opening complete all as specified and directed. |
| 6 | Taking downchowkats or frames with shuttersnot exceeding 1.5 Sqm each(without taking off shutter from the frame) complete all as specified and directed. |
| 7 | Taking downchowkats or frames with shuttersexc 1.5 Sqm and n exc 3.00sqm each(without taking off shutter from the frame) complete all as specified and directed. |
| 8 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 9 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 10 | Demolition cement concrete (un reinforced) of any description fin ground floor n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 11 | Excavation in trenches n exc. 1.5m wide & n exc. 1.5m in depth for foundation etc. and getting out in soft / loose soil complete all as specified and directed. |
| 12 | M&L for PCC 1:4:8 type D-2, (using 40mm graded stone agreaget) as in foundationfilling and mass concrete complete all as specified and directed. |
| 13 | M&L for brick work with Fly ash brick75 kg/cmsq compressive strength oldsize , is straight or curved on plan exc. 6 metermean radius built in cement mortar 1:6 complete all as specified and directed. |
| 14 | S&F TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping ends andbinding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 15 | All as per item No 14 above but 5 mm dia and over upto 10 mm dia in stirrups complete all as specified and directed. |
| 16 | M & L for RCC Type B-1, 1:2:4 (Nominal mix) (using 20 mm graded stone aggegate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 17 | M & L for RCC type B-1, 1:2:4 (Nominal mix) (using 20 mm graded stone aggegate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 18 | M&L for Formwork to soffits of suspended slabs such flat surfaces as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 19 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings girders, bressummers, lintels, cantilevers, shelves including supports overhangs, tc. also splays between floors and beam etcfor rough finished surfacesof concrete complete all as specified and directed. |
| 20 | M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in in lintels upto 1.5m clear span, cills, , bed plates, coping, benching etc water troughs and the like including weathering, slightly rounded or chamfered angles and throatingcomplete all as specified and directed. |
| 21 | S & F Steel work in tubular trussesincluding special shapedwasher etc. complete usingERW or induction butt weldedtubes conforming to I. S.1161 1979 grade St.-240 including distance pieces, cleats ,gusset plates etc complete all as specified and directed. |
| 22 | S & F steel work ,Fe-410-W (Gde-E-250) quality-A, in roof trusses(framed) /purlins /crane gantries rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats ,gusset plates etc complete all as specified and directed. |
| 23 | M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 24 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength 550 Mpa as in roof covering /cladding to wall /roof covering fixed with self tapping screw complete all as specified and directed. |
| 25 | All as per item No 24 but except sheeting complete all as specified and directed. |
| 26 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, weather boarding fixed with self tapping screws /J or L hooks complete all as specified and directed. |
| 27 | Material and labour for suspended false ceiling using E-grid 2430, 180 GSM (concealed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 6mm thick high Pressure Non Asbestos Fiber Cement(E-Board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid complete all as specified and directed. |
| 28 | M&L for Hard core of gauge n.exc 63 mm with broken stone agg deposited spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 29 | M&L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub basecomplete all as specified and directed. |
| 30 | M&L for machine cutkota stone slab flooring 20-25mm thick over 20mm thick cement screed base in CM 1:6 laid and mirror polish to give high gloss finish, jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing complete all as specified and directed. |
| 31 | M&L for digital glazed ceramic tiles in vertical surfaces 450 x 350 x 7 mm thick,etc set and jointed in neat cement slurry and pointedin coloured cementto match the shade of tiles including 10mm thick backing coat in 1:4 cement mortor complete all as specified and directed. |
| 32 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed. |
| 33 | M&L for Rounding to edges of stone slabs on edge such as cooking plateform and counter top complete all as specified and directed. |
| 34 | M&L for Non - skid colour Ceramic tiles 7 to 8 mm thick area of each tile 0.11 sqm but not exceeding 0.18 sqmin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in coloured cement to match of lighter shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 35 | M&L for Non - skid colour Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqmin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in coloured cement to match of lighter shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 36 | All as per item No. 35 but in vertical surfaces, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 10mm thick rendering or backing coat in cement mortar 1:4 complete all as specified and directed. |
| 37 | S&F stainless steel satin finished single bowl of size 610mm x 450mm x 300mm each with faucet hole made from AISI-304 (18/8) S/S with suitable coupling waste pipe PVC 32mm dia fixed with MS work or RCC slab make silver shine (blue star) model No SS3105-24 or equvalent and sink cock of suitable size of faucet hole mixer CP/SS make silver shine blue star model No 1077 or equvalentas approved complete all as specified and directed. |
| 38 | S&F 15mm Brass CP mixer formixing hot & coldwater screweddown for iron pipeand fixed to GI pipe complete all as specified and directed. |
| 39 | Supply and fix GI tubing 15mm bore medium gradewith all fittings fixed to wall and ceilingcomplete all as specified and directed. |
| 40 | All as per item No.39 above but 20mm bore complete all as specified and directed. |
| 41 | S&F PVC (SWR) pipes single socketed, in any lengthwith rubber ring joints, laid in trenches or in floors of dia 110mm complete all as specified and as directed. |
| 42 | M&L for cement conrete 1:3:6 type C-2 concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 43 | S & F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc including filling of concrete and make good complete all as specified and directed. |
| 44 | All as per item No 43 but 105 x 60mm complete all as specified and directed. |
| 45 | S&F 30mm Flush shutters, solid coreconstruction with blockboard core and plywoodface panels, commercialtype on both sides fixed to iron and wooden frame complete all as specified and directed. |
| 46 | S&F 35 mm thick factory made second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass,wire gauze, etc. divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters complete all as specified and directed. |
| 47 | S&F 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 48 | S&F 125mm long size ISI Marked extruded aluminium alloy handles, cast type anodised complete all as specified and directed. |
| 49 | S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 50 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etcetc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed. |
| 51 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed. |
| 52 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 53 | All as per item No 52 but without glazing bars complete all as specified and directed. |
| 54 | Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 55 | M&L for 25mm thick cement concrete 1:2:4,type B-1, (using 20mm graded stone aggregate) as in floors to receives tiles complete all as specified and directed. |
| 56 | M&L for 75mm thickcement concrete 1:3:6 type C2 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed. |
| 57 | M&L for 75mm thick PCC 1:2:4 Type B1 (40mm graded stone aggregate),as in top layer, finished fair and evencomplete all as specified and directed. |
| 58 | M&L for20 mm thick screed bedor bedding layer incementmortar (1:6)overcement concrete complete all as specified and directed . |
| 59 | M&L for Paver tiles 8 to 12mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqmin floors set , jointed & pointed with neat cement slurrywith white cement and matching pigmentcomplete all as specified and directed . |
| 60 | Taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 61 | M&L for rendering 10 mm thick cement plaster in cement mortar 1:6 on fair faces of brickwork or concrete surfaces complete all as specified and directed. |
| 62 | M&L for rendering 15 mm thick cement plaster in cement mortar 1:4 onfair faces of brickwork or concrete surfaces in two layers (10+5)mm top layer 5mmmixed with liquid water proofing compound @200ml per bag of cement or as per manufacturer\"s instruction complete all as specified and directed. Note : WPC shall be measured and paid separately |
| 63 | Supply onlyliquid Water Proofing Compound. |
| 64 | S&F PVC (SWR) pipes single socketed, in any lengthwith rubber ring joints, laid in trenches or in floors of dia 75mm complete all as specified and as directed. |
| 65 | S&F PVC (SWR) bends of 110 mmcomplete all as specified and as directed. |
| 66 | S&F for PVC nahani trap, plain with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) with solvent cement of dia 75mm complete all as specified and directed. |
| 67 | S&Fvitreous china wash hand basin white flat back size 550mmx400mm excluding taps waste chain and plug and percelain stopper including two coats of synthetic enamel paint over coat of red oxide primer on exposed surfaces of brecketswaste coupling brass CP 32 mm bore with long screwed shanksbedded in red lead cement and other end fixed and pillar taps 15 mm bore cast copper alloy fancy type chromium plated screwed down high pressure withlong screwed shanks screwedand removing debris out of MoD land complete all as specified and directed. |
| 68 | S&F vitreous China wash down water closet panwhite,incl. trap, connection to drain and flushing pipe including seat cover for pedstal pan complete all as specified and directed. |
| 69 | S&F 10 litre capacity vitreous china valveless syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including bracketscomplete all as specified and directed. |
| 70 | S&F 32 mm bore Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed. |
| 71 | S&FPVC connections 15mm size with PTMT nuts of length 450mm fixed to pipes and valves complete all as specified and directed. |
| 72 | S&F15 mm bore bib taps cast copper alloy with Chromium platedcrutch or butterfly handle scrwed, screwed for iron pipe or for brass ferruleand fixed complete all as specified and directed. |
| 73 | S&F 15mm bore stop valvesfancy type, chromium plated screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions fixed complete all as specified and directed. |
| 74 | S&F 600x450mm size bevelled edge mirror of selected quality glass 6mm thick mounted on any type of wall including polishingand fixed on wall withchromium plated studds and cup washers complete all as specified and directed. |
| 75 | S&F Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges fixed with SS screwes complete all as specified and directed. |
| 76 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 77 | M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane incl hacking out broken glass complete all as specified and directed. |
| 78 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.0mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 79 | M&L for two coats of oil emulsion distemper on wall newly plasterd surfaces over a coat of chalk white primer including wall care putty makingsmooth finish surface and complete prepatation of new surfaces complete all as specified and directed. |
| 80 | M&L for complete removal of exsiting treatment preparing of old decorative distempered internal surface of walls and applying two coats of distemper oil emulsion complete including filling cracks with wall care putty wherever necessary complete all as specified and directed. |
| 81 | M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 82 | M&Lfor preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paintcomplete all as specifed and directed. |
| 83 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of redoxideincluding scaffolding where required for external painting complete all as specified and directed. |
| 84 | M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paintincluding scaffolding where required for external painting complete all as specified and directed. |
| 85 | Material & Labour for applying Two coats of anti fungal weather proof exterior acrylic emulsion paint of approved tint with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm/ltr as per manufacturer\"s instructions and all coatsto be applied with fully automatic airless spray machine of paint application with a flow speedof minimum 1 ltr per minute having a pressure of 3300 psi. allow 6-8 hrs to dry the surface in subquent coats of paint complete all as specified and as directed Make : Apex Ultima Protek asian paints /Nerolac excel top guards /berger weather coat long like 10 |
| 86 | M&L Complete removal of existing treatment and applying Two coats of anti fungal weather proof exterior acrylic emulsion paint of approved tint with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm/ltr as per manufacturer\"s instructions and all coatsto be applied with fully automatic airless spray machine of paint application with a flow speedof minimum 1 ltr per minute having a pressure of 3300 psi. allow 6-8 hrs to dry the surface in subquent coats of paint complete all as specified and as directed Make : Apex Ultima Protek asian paints /Nerolac excel top guards /berger weather coat long |
| 87 | Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm complete all as specified and directed. |
| 88 | Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed. |
| 89 | Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed. |
| 90 | M & L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade IS-694 marked drawn through in and including heavy duty grade (ISI marked) PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, with GI sunken boxeswith earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the One light controlled by one, one way switch 5 AmpsNote:- Cost of Modular Cover Plate, Inner frame suitable for mounting modular switches, socket etc are deemed to be included in the quoted rate. |
| 91 | All as per item No 90 above but one fan point/exhaust fan point controlled by one, one way switch 5 Amps and regulator complete all as specified and directed. |
| 92 | All as per item No 90 above but one 3 point 5 Amps switch socket outlet point controlled by one switch on the same borad complete all as specified and directed. |
| 93 | All as per item No 90 above but one 3 pin 5 Amps switch outlet point controlled by one switch on independent board complete all as specified and directed. |
| 94 | All as per item No. 90 above but using 2.5 sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sqmm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 95 | S&F modular switch piano flush type, single pole, one way, 5/6 Amp single module complete all as specified and directed. |
| 96 | S&F modular switch piano flush type, single pole, one way, 15/16 Amp single module complete all as specified and directed. |
| 97 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed. |
| 98 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed. |
| 99 | S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 100 | S & F ceiling rose, surface bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed. |
| 101 | M&L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed.Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit. |
| 102 | M&L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.5 sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed.Note: Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm cable and one run of PVC conduit will be measured as one unit. |
| 103 | S & F sheet metal enclosure MCB DB SPN 8 way with bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. |
| 104 | S & F MCB single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 105 | S & F MCB single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 106 | S & F ceiling fan 230V, 50 Hz AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed. |
| 107 | S&F wall Mounted fan, made of sturdy Engineering plastic, Voltage 230 V, 50 Hz, RPM 1350 Copper Winding of sweep 400 mm including connection with three core, 0.75 Sqmm PVC insulated copper conductor cable complete all as specified and directed. |
| 108 | S & F exhaust fan, steel body AC single phase 230 Volts of size 300mm sweep with, blades, frame and louvers with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 0.75 Sqmm three core from ceiling rose to exhaust fan forconnection complete all as specified and directed. |
| 109 | S & F exhaust fan, steel body AC single phase 230 Volts of size 450mm sweep heavy duty with, blades, frame and louvers with bolts nuts and washers, embedded in the wall including provision of PVC flexible copper cable of size 0.75 Sqmm three core from ceiling rose to exhaust fan forconnection complete all as specified and directed. |
| 110 | Cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type, B-1 as required superficial area exc. 150 Sqcm but not exc. 400 Sqcm complete all as specified and directed. |
| 111 | S & F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 23/0.193 Sqmm from ceiling rose to fitting complete all as specified and as directed. |
| 112 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of size 0.75 sqmm complete all as specified and directed. |
| 113 | S & F in repair of three pahse DOL starter sheet steel enclosure AC-3 rating relay range 9-15 Amp suitable for 3 HP motor for kitchen chimaney complete all as specified and directed. |
| 114 | S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and necessary mounting arrangements alongwith provision of 0.75 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including suitable dia GI pipe medium grade bracket 0.75 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed. |
| 115 | Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch \"A\" while deriving the Contract Sum for Acceptance. |