| 1 | Taking down copper/aluminium point wiring ( light,fan, socket or power) complete,incl fixtures and fittings like switches, ceiling rose, pendant, regulator, sockets, light fitting ( Mirror light,Bulk head,LED Panel 2\"\"x2\"\",security light,wall fitting,down light, Flood light,post top lantern)etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. |
| 2 | M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for the following points:- |
| 3 | One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 4 | One 6A socket point controlled by one switch on independent board |
| 5 | One 6A socket point controlled by one switch on same board |
| 6 | One light point controlled by two, two way switches. |
| 7 | All as per item No. 2.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 8 | All as per item No. 2.00 here-in-before but one 16A socket point controlled by one 16A switch on independent boardbut just below / above the existing socket points / DBs up to one meter distance in the same vertical plane, with cables 2.5sq. mmsize. |
| 9 | All as per item No 2 above here in before but wiring in casing caping for the following :- |
| 10 | One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 11 | One 6A socket point controlled by one switch on independent board |
| 12 | One 6A socket point controlled by one switch on same board |
| 13 | One light point controlled by two, two way switches. |
| 14 | All as per item No. 5.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed. |
| 15 | All as per item No. 5.00 here-in-before but one 16A socket point controlled by one 16A switch on independent boardbut just below / above the existing socket points / DBs up to one meter distance in the same vertical plane, with cables 2.5sq. mmsize complete all as specified and directed. |
| 16 | M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length) |
| 17 | 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) |
| 18 | 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) |
| 19 | 2runs x 10 sqmm(Ph & N) + 1run x 10 sqmm(earth wire) |
| 20 | 4runs x 10 sqmm(Ph & N) + 1run x 10 sqmm(earth wire)Notes for item No. 1.00 to 8.00: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure.(iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion. |
| 21 | Supply and fix in replacement of Modular switch 1 way 6A, 1 module 240V, 50Hzcomplete all as specified and directed. |
| 22 | Supply and fix in replacement of Modular switch 1 way 16A, 1 module 240V, 50Hz complete all as specified and directed. |
| 23 | Supply and fix in replacement of Modular switch 2 way 6A, 1 module 240V, 50Hz complete all as specified and directed. |
| 24 | Supply and fix in replacement of Modular Bell push 6A 1 module, 240V, 50Hz complete all as specified and directed. |
| 25 | Supply and fix in replacement of electric call bell ding dong type, AC, 240V, 50Hz complete all as specified and directed. |
| 26 | Supply and fix in replacement of Modular Socket,6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed. |
| 27 | Supply and fix in replacement of Modular Socket6A/16A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed. |
| 28 | Supply and fix in replacement of Modular fan regulator step type in 5 steps, 240V, 50Hz complete all as specified and directed. |
| 29 | Supply and fix in replacement ceiling rose in poly carbonate 3 terminal brass, flush type 6 Amps, 220 volts AC, ISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and directed. |
| 30 | Supply and fix socket type modular hum free electronic step fan regulator compatible for BLDC fan all as specified and directed. |
| 31 | Supply and fix in replacement of Lamp holder, angle type with metal ring, PVC/Polycarbonate body type B-22 with back plate, including LED bulb 12 watts(White/ Warm White) complete all as specified. Make of Angle Holder: Cona Model No: 2471 or equivalent in Havells/ Philips/ Anchor Makeof Bulb: Philips Model Name: Ace Bright or Equivalent model in Bajaj/ Havells/ Wipro |
| 32 | Supply and fix in replacement of old unserviceable LED tube light fitting Integral slim LED batten 20 watts with polycarbonate housing and diffuser internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified. |
| 33 | Supply and fix in replacement of old unserviceable LED mirror light light fitting Integral slim LED batten Integral 9 / 10 watts of 2 feet long internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 34 | Supply and fix in replacement of recessed mounted LED panel light 2\"x2\" size, 36 watts, full white / warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP / Amstrong / grid false ceiling complete with all fixing accessories including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 35 | Supply and fix in replacement Decorative wall light fitting, made out of polycarbonate suitable for B-22 base LED lamp including 10 watts LED lamp, full white of approved model fixed on wall and making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 36 | Supply and fix in replacement ofLED bulkhead luminaire 10watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit with diffuser, including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 37 | Supply and fix in replacement of sleek round recessed cum surface mounting LED down light 12 W with aluminium die-cast body, finish with drop down PC diffuser 3 in 1 wave colour changing LED light or warm / full white as per site requirement with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 38 | Supply & fix Bi-directional beam LED wall washer 4Watts made out of Aluminum Die Cast, energy efficient with IP65 protection, including fixing on the wall and making electrical connection complete all as specified and directed. Make: Havells Cat No: LHEVADPBPN6K004 or equivalent modelin Philips/Crompton/Bajaj |
| 39 | Taking down old usnerviceable Wall Fans and Supply & fix Wall fans 400mm sweep with plastic fiber body, and web mesh guard, 230V AC, single phase, oscillating type complete and fixing the fan to wall including making electrical connection with ceiling rose including taking down existing unserviceable wall fan of any description complete all as specified and directed. |
| 40 | Taking down old unserviceable Ventilating/Exhaust Fan and Supply and fix ventilating / PVC exhaust fans fancy square type 250mm sweep with plastic fiber body heavy duty 230 Volt AC, single phase complete with plastic louvers and including making suitable size of holes in wall for fixing the fan including making electrical connection with ceiling rose including taking down existing unserviceable ventilating fan of any description complete all as specified and directed. |
| 41 | All as per item No- 28 above but of size 200 mm complete all as specified and directed. |
| 42 | All as per item No- 28 above but of size 150 mm complete all as specified and directed. |
| 43 | Taking down old usnerviceable Metal Exhaust Fan and Suppy & fix Metal exhaust fans square type 300mm sweep with Metal body heavy duty 230 Volt AC, single phase complete with louvers including making electrical connection with ceiling rose complete all as specified and directed. |
| 44 | All as per item No- 31 above but of size 250 mm complete all as specified and directed. |
| 45 | Taking down existing old ceiling / exhaust fan of any size carefully, sealing cable end, dismantling blades and removing fan and blades and deposited to AGE E/M store yard complete all as specified and directed. |
| 46 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. with brushless direct current motor (BLDC) complete all as specified and directed. |
| 47 | Supply and fix electric water heater, storage type steel body with glass lined inner tank and heating element upto 2 KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat,NRV, connection pipe etc including all water connections and fixing on wall with suitable MS tower/ anchor bolts, grouted to wall complete all as specified and as directed. |
| 48 | Supply and fix in replacement of LED street/security light fitting 30 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washersand provision of 3 core pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. |
| 49 | Supply and fix in replacement of old unserviceable LED Flood light fitting 50 watt capacitywith SMD LED pressure die-cast aluminium housing with reflactor including making electrical connection with pvc insulated and pvc sheathed twisted three core wire of suitable size complete all as specified. Note :- The Quoted rate is deemed to be included for installation of light fitting at any height including necessary T & P and safety equipments. |
| 50 | Supply and fix in replacement of LED Post Top Lantern light fitting 35/40 watt capacity with transparent diffuser and fixing arrangement on new GI pipe medium grade of dia 80mm and duly grouted on wall/brik pillar with the help of cement mortar including making electrical connection with PVC insulated and PVC sheathed twisted three core wire of size 1.5 sqmm complete all as specified and directed at site. |
| 51 | Supply and fix in replacement of old unserviceable Post Top lantern light fitting of capacity 1x7/8 watts with B-22 base LED bulb, transparent polycarbonate diffuser and fixing arrangement on new GI pipe of 20/25mm dia medium grade duly grouted on ground/wall/brick pillar with the help of cement mortar including making electrical connection with pvc insulated and pvc sheathed twisted three core wire of size 0.5 sqmm fromjunction box to light fitting complete all as specified and directed at site. |
| 52 | Supply and fix in replacement PVC / DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof suitable for outdoor installation for Gate light and Post top lantern, fixed on wall with screw & rawal plug and on GI Pipe wth suitable size MS clamp and Nut-bolts,washer and outer dimesnion of size 170mm x 170mm x 105mm complete including one connector block three terminals and PVC cable gland 02 Nos for incoming and outgoing cables with provn of 01 nos single pole MCBs 10-32 amps inside the box including taking out/down existing unserviceable junction box of any description complete all as specified and directed at site.Make : Syntex model No-GSJB 1414 or any equivalent moden in Naptune/Hensel. |
| 53 | Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface all as specified. |
| 54 | Supply, intsall and commissioning meter box of size 1000mm(L) x 1000mm(H) x 200mm(D) with space for MCCB as incomer and suitable space for installing 4 nos 3 Phase electronic meter in separate compartment made out of 2mm thick CRCA sheet duly powder coatd, including 200A rating 4 nos copper bus bar chamber , including power wiring with using PVC insulated stranded copper wire of size 10sqmm duly provided lugs from busbar to meter and meter to control MCB with provisioning transparent glass in front of meter complete rubber gasket, locking and sealing arrangement including following MCCB/MCB:(a) S&F Incomer MCCB 160 Amps, 25kA, 4 Pole - 1 nos (Incomer)(b) S&F Outgoing MCCB 63A SP, 240V - 4 nos (Outgoing) (c) S&F Outgoing SPN 20A - 1 nos (Outgoing)Note: Drawings of the panel should be approved from GE before placing the order. |
| 55 | Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately. |
| 56 | Supply and fix in replacement of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCBs shall be measured and paid separately. |
| 57 | All as per item No. 44 here-in-before but SPN, 12 way, 230 V, 1 phase, AC complete all as specified and directed.Note:MCBs shall be measured and paid separately. |
| 58 | All as per item No. 44 here-in-before but SPN, 8 way, 230 V, 1 phase, AC complete all as specified and directed. Note:MCBs shall be measured and paid separately. |
| 59 | All as per item No. 44 here-in-before but SPN, 4 way, 230 V, 1 phase, AC complete all as specified and directed. Note:MCBs shall be measured and paid separately. |
| 60 | Supply and fix MCCB 160A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed. |
| 61 | Supply and fix in replacement of MCB 100A, 10 KA, TPN, \"C\" Curve, 415 V, 50 Hz including taking down exisiting unserviceable MCB of any description complete all as specified and directed. |
| 62 | Supply and fix in replacement of MCB 40A, 10 KA, SPN,\"C\" curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 63 | Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, \"C\" curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 64 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter).The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 4000 kg load bearing capacity (Size:270 x 40 200mm) complete all as specified and directed. |
| 65 | M&L in replacement of unserviceable Bus-bar chamber made out of sheet metal enclosure 100 Amps power coated independent for five connections, copper busbar suitable for 100 amps current rating mounted on wall, including connecting all incoming and out going electrical connections complete all as specified and directed . |
| 66 | Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated multi-stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098 (Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 67 | All as per item No 54 but of size 10 sqmm 4 core complete all as specified and directed. |
| 68 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts complete all as specified and directed. |
| 69 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of Cable/Pipe and getting out in any type of soil complete all as specified and directed. |
| 70 | Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 71 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 72 | M&Lfor cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items. |
| 73 | Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 9\" X 11\" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed.Note: S&F of switches, sockets & regulators shall be measured and paid separately. |
| 74 | All as per item No- 60 above but of size 8\" X 5\"complete all as specified and directed. |
| 75 | All as per item No- 60 above but of size 5\" X 5\"complete all as specified and directed. |