| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 2 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed |
| 3 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed |
| 4 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.36 Sqm in skirting/dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed of cement mortar 1:3 complete all as specified and directed |
| 5 | M&L for coloured Glazed ceramic tiles in vertical surfaces 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement over and including 10mm thick rendering or bedding layer of cement mortar 1:3 complete all as specified and directed |
| 6 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof coverings complete all as specified and directed |
| 7 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed |
| 8 | S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with twocorrugations side lap fixed with coach screw and washer in roof, wall etc all as specified and directed |
| 9 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, fixed with self tapping screws all as specified and directed |
| 10 | M&L plain anodised aluminium flat section as in wind tie with GI self tapping screws complete all as specifed |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed |
| 12 | Excavation in post hole in hard/dense soil (or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface complete all as specified and directed |
| 13 | S&F mild steel roof trusses (framed), trrussed, purlins, crane gantries, rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed |
| 14 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed |
| 15 | M&L forapplying two coats of synthetic enamel paint over a coat of red oxide primer includingpreparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 16 | M&L forapplying two coats of synthetic enamel paint includingpreparation of old steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 17 | Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed |
| 18 | M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed |
| 19 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed |
| 20 | M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed |
| 21 | M&L for 75mm thick PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and smooth complete including filling the joints with mastic compound all as specified and directed |
| 22 | M&L for precast cement concrete louveres and jallies 40mm thick(measured solid), including all mouldings, type B0, 1:2:4 (using 12.5mm graded stone aggregate) and set in cement mortar 1:4 all as specified and directed |
| 23 | Dismantling of wallandceilingboards(fibre, pulp, insulation etc) or insulationboards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed |
| 24 | S&F for anodized aluminum snap grid frame work for false ceiling incl hangers 6mm dia/3mm dia GI wire (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60 mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed |
| 25 | M&L for 4mm thick non asbestos fiber cement building design board of size 605x605mm fixed or laid to aluminum grid work with screws and including preparation of surface with two coat of oil bound distemper over a coat of chalk whiting primer complete all as specified and as directed |
| 26 | Taking down chowkhats or frames area n. exc 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed |
| 27 | Taking down Chowkatsexc 1.5 Sqm but n. exc 4 Sqm each with shutters (Without taking off shutters from the frame) complete all as specified and directed |
| 28 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm both side prelam PVC sheet and edges will be painted to match with the prelam sheet reinforced with MS square tube in opening incl necessary fixing arrangements as per specification and drawing complete all as specified and as directed |
| 29 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails.MS frame shall be covered with heat moulded prelam PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheetfor top rail, lock rail and bottom rail on either side as gap insert for top rails, bottom rail, panelling of both side prelam PVC sheet to be fitting in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement in the frame at site as per specification and drawing |
| 30 | S&F 100mm size stainless steel butt hinges medium weight complete all as specified |
| 31 | S&F 150mm aluminium, anodised, barrel tower bolts of extruded section all as specified |
| 32 | S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised all as specified |
| 33 | M&L for anodised aluminium frame for doors, windows, ventilators, partition with one or more rebates including joining cleat for fixing etc complete as specified |
| 34 | M&L for anodised aluminium door shutters, aluminium section weighing not less than 1.55 Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, tower bolts, anodised aluminium snap beading screws etc complete all as specifiedNote : Supply only floor spring, glass, SS friction hinges,particle board, wire gauze will be measured seperately |
| 35 | M&L for anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified complete all as specifiedNote : Supply only glass, particle board, wire gauze will be measured seperately |
| 36 | M&L for anodised aluminium window and ventilator shutters, side hung/sliding type without sash bars, aluminium sections weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays/Imax hinges 01 No, hinges type B-21 100mm long 02 Nos suitable handle 01 No per shutter or as required etc complete all as specified Note : Supply only glass, particle board, wire gauze will be measured and paid seperately |
| 37 | S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed |
| 38 | Supply onlysheet glass 5.5mm thick ordinary quality and glazing with aluminium glazing clip in aluminium door/window/ventilator shutter not exc 0.5 Sqm in each pane |
| 39 | Supply only sheet glass 4 mm thick ordinary quality and glazing with aluminium glazing clip in aluminium window/ventilator shutter not exc 0.5 Sqm in each pane |
| 40 | Supply only 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work complete all as specified |
| 41 | Supply only aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium wire staples all as specified and directed |
| 42 | S&F door closer hydraulically regulated aluminium (die cast) body, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified |
| 43 | S&F 250mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate |
| 44 | Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed |
| 45 | M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and settingin cement mortar 1:4 all as specified |
| 46 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 47 | M&L for 10mm thick plaster in CM 1:6 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified |
| 48 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of average 1mm thick wall care putty to make the surface smooth complete all as specified and directed |
| 49 | M&L for applying two coats of oil bound distemper over a coat of average 1mm thick wall care putty to make the surface smooth after complete removal of existing treatment complete all as specified and directed |
| 50 | M&L for 15mm thick plaster in CM 1:4 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified |
| 51 | M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed |
| 52 | M&L for complete removal of existing treatment on plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed |
| 53 | S&F in repair 600x450x6mm thick looking mirror bevelled edge of selected quality glass fixed with stainless steel glass fastner complete all as specified |
| 54 | S&F in repair vitreous china wash down water closed pan (Pedestal pattern) white, including connection to drain (or out going pipe) and to flush pipe, antisypthonic (excluding flushing cistern and flush pipe) complete all as specified |
| 55 | S&F in repair plastic water closet seat cover, white, closed pattern with flat bottom including mild steel chromium plated or aluminised hinging device complete all as specified |
| 56 | S&F in repair PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action push type with inlet ball valve and float including flush pipe long 32mm dia, ball valve, handle, bracket etc complete all as specified and directed |
| 57 | S&F in repair vitreous china counter wash hand basin oval shape of size 550x400mm including brackets, 32 mm CP waste coupling, chain and plug, waste fittings all necessary inlet and out let connections complete all as specified |
| 58 | S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified |
| 59 | S&F 32 mm dia PVC flush pipe of polyethylene of low or high density for WHB, sink, urinal complete all as specified and directed |
| 60 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed |
| 61 | S&F in repair 20 mm dia brass stainless steel tubular towel rail D type600mm long complete all as specified |
| 62 | S&F in repair 15mm dia cast copper alloy chromium plated long body bib tap fancy type with wall flange complete all as specified |
| 63 | S&F in repair 15mm dia cast copper alloy, chromium plated pillar tap long body swan neck type with fly nut capstan head screwed for 15mm bore dia of pipe complete all as specified |
| 64 | S&F in repair 15mm Stop valve angle cock cast copper alloy, fancy type, chromium plated with long shunk and cup high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified |
| 65 | Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed |
| 66 | S&F 20mm outer dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including suitable reducer for 15mm dia taps fitting as required complete all as specified |
| 67 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth |
| 68 | Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed |
| 69 | S&F of 25mm outer dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 70 | S&F 25mm boregun matel globe or gate valve with iron wheel, screwed both ends for iron pipes complete all as specified |
| 71 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed |
| 72 | S&F PVC (SWR) pipe 110mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive laid in trenches or in floors complete all as specified and directed |
| 73 | S&F in repair PVC (SWR) 110mm dia bend of any radius and jointed with approved adhesive complete all as specified and directed |
| 74 | S&F PVC (SWR) pipe 75mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive laid in trenches or in floors complete all as specified and directed |
| 75 | S&F in repair PVC (SWR) bend 75mm dia of any radius as required and jointed with approved adhesive complete all as specified and directed |
| 76 | S&F in repair75mm outlet dia PVC (SWR) floor trap with grating including jointing with solvent cement to waste pipe complete all as directed |
| 77 | Dismantling PVC water tanks exc 500 Ltr but n. exc 1000 Ltr capacity and removing to store complete all as specified |
| 78 | S&F double layer rotational moulded PVC water storage tank cylinderical, vertical with closed top hoisted and fixed in position tank capacity 1000 Ltr with and including PTMT float valve 20mm dia and making connection for inlet and outletcomplete all as specified and directed |
| 79 | Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittingS&Fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets,junction/terminal boxes etc;removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed. |
| 80 | Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 81 | Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 82 | M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVCinsulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealedin walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex/V-Marc and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces. |
| 83 | Allas per item Sl No 82 above, but , for One light/fan point controlled by one modular switch 5 Amps one way complete all as specified and directed. |
| 84 | Allas per item Sl No 82 above, but , for two light point controlled by one switch 5 Amps one way complete all as specified and directed. |
| 85 | Allas per item Sl No 82 above, but , for one modular 3 pin 5 Amp socket out let on independent board complete all as specified and directed. |
| 86 | Allas per item Sl No 82 above, but , for one modular3 pin 5 Amps socket outlet on sameBoard complete all as specified and directed. |
| 87 | All as per item No.82 above, but , point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out letand one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified andas directed. |
| 88 | S&F for switchmodulartype, 6 Amps 1 module, 230 volts AC circuit complete all as specified andas directed. |
| 89 | S&F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified anddirected. |
| 90 | S&F Socketoutlet 2 in 1 modular type,3 pin, 6 and 16, universal complete all as specified andas directed. |
| 91 | S&F Switch modular type , single pole one way 16 amps complete all as specified andas directed. |
| 92 | S&F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete all as specified andas directed. |
| 93 | S&F stepped type electronic fan regulator modular type complete all as specified andas directed. |
| 94 | Supply & fix Modular Ac Box With 20A DP MCB \"C\" Type, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top, 240 volts AC supply for air conditioner, flush mounting in the wall complete all as specified and directed. Make:- Anchor (Roma) model no 98492 or equivalent in Havells / ABB |
| 95 | S&F of LED slim panel lighting fixture of following cap recessmounted220V , 50Hzwith finished in premium white powder coating ,environmental friendly energy efficient fitting recessmounted round/squarein shape(Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed for the following : NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting . |
| 96 | 12 Watt recessmounted. Make - Luker Cat Part No : LNPR12 or equivalent make inCG/ Philips/ Havells. |
| 97 | 15 Watt recessmounted. Make - Luker Cat Part No : LNPR15 or equivalent make inCG/ Philips/ Havells. |
| 98 | S&F30 wattsLED building security light fittings , pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 with pranuts including necessaryfixing arrangements as per site requirements all as specified and directed by Engr In charge. Make : Luker Cart Part No: LSTE-30 or equivalent to Philips /Havells/ CG |
| 99 | S&F andtesting LED Tube light fittings aluminium tubes 24 watts 4 feetincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified anddirected. Make: Luker Cat Part No : LT5M24 or equivalent to CG/Philips Havells |
| 100 | Supply and fixing andtesting Mirrior light fitting of cap 20 watt with all fixing arrangements all as specified and directed. Make-Havells cat no LHLDESAARANC020or equivalent to Philips/ CG |
| 101 | Supply and fixing in replacement ofLED floodlight of cap 150 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, System efficacy ≥ 110/120LPW 10KV included driverincludingfixing on wall of any hight or any pole/ iron structure etcincluding taking down of the old unserviceable halogen/any type of old unsv lightfittings all as specified and directed.Make: CG Model No : LFLN-150-CDL/60-M or equivalent model of /Philips/ Havells /Luker |
| 102 | Supply and fixing new GI brackets of GI pipe light grade of size 25 mm dia including nuts, bolts and washers for building secufity light all as specified and directed |
| 103 | Taking down carefully ceiling fan of any make, size from its location, dismantling complete, examine complete parts thoroughly, oiling, greasing all parts and complete overhauling of fan including replacement of small parts such as split pin, nut bolt, screws and assembling back the fan,make fully functional, re-fixing the fan to its position including replacing and providing of twin core copper wire 23/0.0076 from fan to ceiling rose and painting the fan with same colour of fancomplete all as directed. |
| 104 | Taking down Exhaust fan/ wall mounted industrial fan of any size from its existing position (from any highted wall) , sealing cable end, removing fan and blades, keep safelyfor repair all as specified and directed by Engr In charge. |
| 105 | M & L for servicingof exhaust fan of cap upto 380-450 mm sweep or wall mounted industrial fan 600 mm sweep of any makeand including PVC sleeves lead wires, bearings etc painting, testing and re-fixing in existing position of exhaust fan and painting the fan with same colour of fancomplete all as directed. (NOTE :- The brunt motor should be rewinded and the same will be measured and paid separately under relevant item of BOQ) |
| 106 | M & L for rewinding of unsv exhaust fan of cap 380 mm sweep of any make by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary and testing after assembling in position and painting the fan with same colour of fancomplete all as directed. |
| 107 | S&F Sub main wiring with PVC insulated FRLSH cable 2 single core 1.5 sq mm 1100 V grade with stranded copper conductor cableusing proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and incl rigid PVC concealed/ surface conduit(ISI marked) incl all specials/ accessories etc and provision of PVC insulated FRLSHcopper conductor single core 1.5 sq mm for earthcontinuity all as directed. |
| 108 | All as per item No 101 above, but , 2.5 sqmm 2 core. |
| 109 | All as per item No 101 above, but , 4.0 sqmm 2 core. |
| 110 | All as per item No101 above, but,6.0 sqmm 2 core.Note for item No 101 to 104 : 3 lengthof cable and one length PVC Conduitshall be measured and paid for one length. |
| 111 | S&FDB VTPNsheet metal enclosure double door suitable for incoming upto MCCB 100 Amps/125 Amps & outgoing MCB TP / SP (IP-43) Protection Triplepole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specifiedanddirected. |
| 112 | S&FSPNDB sheet metal enclosure double door suitable(IP-43) Protection 8 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. |
| 113 | All as per item No 106 above ,but,12 way |
| 114 | S&F in replacement of MCCB, 4 pole, 100 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release alongwith copper separator terminalscomplete all as specified and as directed. |
| 115 | Supplying & fixing MCB SPN 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed . |
| 116 | S&FMCB SP 06-32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed .Note for item No 108.0 & 110.0:- Termination of all wiring in to MCBs/ MCCBs/DBs shall be through copper lugs/thimbles of adequate size. |
| 117 | Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement all as specified and as directed by Engineer-in- Charge. |
| 118 | M&L for Earthing complete with galvanisedearth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means boltsand nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,.CI cover with frame etc including necessary excavation in any type of strata , returning, fillingremoval of soil outside MD land ,filling ofcharcoal andsalt complete all as shown in electrical plate No.3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mmc/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II.2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |