| 1 | Taking down cement plaster on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc but lime plaster any description, complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L for Self Curing Ready Mix Plaster of thickness 12 mm to 15 mm, pre-packaged, ready-to-use formulated with cement, graded sand, polymers, and special self-curing compounds on external surfaces of walls, chajja, facia at any height with necessary scafolding surface finished even and smooth including taking down cement or cement lime plaster, raking out joints and preparing for plastering the wall surface with white cement based polymer modified including disposal of rubbish, complete all as specified and directed by Engr-in-Charge.Make-JKCement /Birla/ Ultratech. |
| 3 | Dismantling brick tiles or terracing tiles, single layer of roofs including demolition and removing of mud in roofs any thickness including plastering and leeping (whether full thickness removed or part thereof ) and demolition material disposed out from MoD land and including roughening surfaces of old concrete by picking, sweeping/Brushing clean and washing down with water to remove dust and apply neat cement slurry with 3.0kg of cement per sq. metre, complete all as specified and directed by Engr-in-Charge. |
| 4 | Demolition of cement concrete (unreinforced) of any description and in any position as in roofs, floors (other than ground floors) and similarworks, complete all as specified and directed by Engr-in-Charge. |
| 5 | M & LPCC 1:2:4 type B-0(using 12.50mm graded stone aggregate) as in roofkerbs/roof padding /benching or mud stops, and platform for mounting service tanks, rounded, chamfered on edges including necessary use and waste of fromwork etc, complete all as specified and directed by Engr-in-Charge. |
| 6 | M & L for cleaning of all loose dirt and dust fromroof surfaces and applyingroof treatment as under :- (a) Applying a coat of fibre reinforced PU primer confirming to ASTM D412 @ 30% water dilution on prepared surfaces & laying of glass fibermesh 45 gsm over tacky surface and allow it to dry.(b) Supply and Applying 2 coats of Hybrid PU based elastomeric single component coating over primer surface @ 10kg /10.76 Sqm total consumption having below properties:-1. Elongation - 500%-600%2. Solid contents - 80%, 3.Tensile Strength - 1.6N/mm2 4. Adhesion to concrete - 2.2N/mm2 5. Initial hardness shore strength - 60Min. 6. Tear Strength - 14Mpa. 7. Total thickness of layer shall be 1.2 - 1.5mm.Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.The work for roof treatment shall include the following and the rates quoted by the bidder shall include the same-(aa) The work pertaining to roof treatment shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like PU primer etc after approval by the GE.(ab) The contractor shall upload with the documents under cover-I \"Memorandum of Understanding\"(MoU)with at least one of the manufacturers mentionedin the contract, failing which the bid shall be liable to be rejected. |
| 7 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge. |
| 8 | M & L for brick work using old size fly ash brick, straight or curved on plan exc 6m mean radius, built in CM (1:6), , complete all as specified and directed by Engr-in-Charge. |
| 9 | Removal of old expansion joint system : Removing of filler board or foam or old system from expansion joint, griding the to of joint for removal or laitance and cleaning of the expansion joint by air blower to remove any dust, dirt loose particles, complete all as specified and directed by Engr-in-Charge. |
| 10 | Treatment of roof expansion joint : All the surface shall be clean with diamont griding machine to remove all the loose and oily material for the concrete surface. Apply epoxy ahesive Sikadur combiflex adhasive /Rearbond 4031 on the both side of the joint with coverage of 7 kg/RM. Apply EPO Tape 2mm x 200mm Sikadur combiflex SG/sealarm Tape TPE on the adhesive to seal the expansion joint . Apply seal layer of Epoxy adhesive on the corners of the tape to seal properly with a consumption of 0.7 kg/RM. Adhisive must be 2-part thixotropic epoxy adhesive for sikadur combiflex SG tape system. The epoxy adhesive must be capable of bondingof bonding with concrete and metal. The compressive strenth must be > 45 N/mm2 in 1 day according to ASTM C 579 and bond strenth of > 1.5 n/MM2 according to ISO 4624 for both concrete and metal substrates.The tape system must be capable of resisting hydrostatic pressure upto 6 bar according to EN 1928-B, tensile strenth . 1.2 N.mm2 according to EN 12311-2, tear strength . 40 N/mm according to EN 12310-2 elongation > 650% according to EN 12311-2 seam strength > 40 N/5cm according to EN 12317-2 chemically resistance to seveal chemicals passes low temperature foldability at -40 C according to EN 495-5, passes artificial weathering 7500 hrs according to EN ISO 4892-2. The tape must be capable of servicing a wide range of temperature of -40 C to + 60 C. |
| 11 | Striping out old roof treatment (tarfelt) from roof top and removing from site, complete all as specified and directed by Engr-in-Charge. |
| 12 | M & L for cleaning of all loose dirt and dust fromroof surfaces and applyingroof treatment as under :- (a) 10 mm thick plastering in CM (1:4) using 100 % coarse sand on roof / parapet walls with WPC @ 2 % by weight of cement.(b) Applying a coat of bitumenous primer @ 0.50 Kgs/Sqm on prepared surfaces and allow to dry.(c ) Applying a coat of hot blown bitumen 85/25 grade @ 1.20 Kgs/Sqm over primer.(d) Suply and laying of3mm thick (Minimum) polymeric water proofing membrane weighing not less than 3 Kgs/Sqm.(e) Applying a tack coat ofhot blown bitumen grade 85/25 @ 1.20 Kgs/Sqm .(f) Blinding with dry coarse sand @ 0.50 to 1.0 Kg /Sqm dusted over bitumen.(g) Suply and laying factory made PCC tiles 40 mm thick over and including 15 mm thick screed bed in CM(1:4) and jointing and pointing in CM (1:4) by mixing linsead oil @ 5 % weight of cement.Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.Note : Pond test will be carried out after roof treatment |
| 13 | Description all as per ser item No 12.00 here-in-befoe but except (g) on vertical surfaces. |
| 14 | Mild steel round bar10 mm diaand over, cut to length, bent to shape required, including cranking, bending spirally for hooping for slabs,beam, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, Fe-410-W(Gde E-250 quality A ) all as specified and directed by Engr-in-charge. |
| 15 | Taking down rain water pipes ( any size or pattern) incl all fittings , shoes, bends, swan neck etc and removal to store, complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F 150mm bore dia PVC (SWR) pipes single socketed in any length with rubber ring joints including clamps providing at every 90cm min interval, fixed to walls, complete all as specified and directed by Engr-in-Charge. |
| 17 | S&F in repairs PVC (SWR) bends any radius with access door 150 mm dia, complete all as specified and directed by Engr-in-Charge. |
| 18 | S&F in repairs PVC (SWR) bends150 mm dia , complete all as specified and directed by Engr-in-Charge. |
| 19 | S&F, in repair 32 mm bore Low density PVC flexible pipe for Wash hand basin/sink etc, complete all as specified and directed by Engr-in-Charge. |
| 20 | Removal of tree/plant/shrubs of any size from walls, ceiling, roofs and joints of pipes etc of the bldg from ground floor to roof level hight upto 20.00 Mtrs including uprooting roots from walls and applying chemical of approved make to arrest the growth andmaking good damaged surfaces in PCC 1:2:4 type B1 or cement mortar (1:3) including necessary scaffolding and other safety arrangements, complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F in repairs CP jetmild steel chromium plated suitable for 15 mm dia pipe with 1.25 to 1.50metre long Spirochrome flexible tube andincluding making connections and fixed in position, complete all as specified and directed by Engr-in-Charge.Make:- Cera, Parryware, Kohler or Jaquar |
| 22 | Supply only integral water proofing compound of approved quality,complete all as specified and directed by Engr-in-charge. |
| 23 | S&F in repairs florentine bib cock, 15mm dia, complete all as specified and directed by Engr-in-Charge.Make:- Cera, Parryware, Kohler or Jaquar |
| 24 | S&F in repairs florentine pillar cock, 15mm dia, complete all as specified and directed by Engr-in-Charge.Make:- Cera, Parryware, Kohler or Jaquar |
| 25 | S&F in repairs push bib cock, 15mm dia, complete all as specified and directed by Engr-in-Charge.Make:- Cera, Parryware, Kohler or Jaquar |
| 26 | M&L rendering 15mm thick in cement plaster 1:4 on surfaces fair faces of brick work and surface finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge. |
| 27 | M&L two coat of acrylic paint exterior grade (100% Acrylic) over a one coat of primer including prepartion of newly plasterd surfaces of walls etc all specified on external surfaces and also include necessary scaffolding and safety arrangement upto 20mtrs height, complete all as specified and directed by Engr-in-Charge. |