| 1 | Schedule \"A\" Part-I (Building Work) Note : This schedule for Schedule \"A\" PART-I is not Pre-Priced by MES and the Pre-Priced rate indicated as \"Rs. 0.00\" under Col. 5 signifies this fact only. |
| 2 | Construction of DSC Guard post with integrated rest room (Single Storey) one block, RCC framed structure all as specified and shown on drawings. |
| 3 | Schedule \"A\" Part-II (Site Clearance Work) carried forward from pre-priced Schedule. |
| 4 | Schedule \"A\" Part-III (Plumbing Work) carried forward from pre-priced Schedule. |
| 5 | Schedule \"A\" Part-IV (Internal Water Supply work) carried forward from pre-priced Schedule. |
| 6 | Schedule \"A\" Part-V (Internal Electrification Work) carried forward from pre-priced Schedule. |
| 7 | Schedule \"A\" Part-VI (External Water Supply work) carried forward from pre-priced Schedule. |
| 8 | Schedule \"A\" Part-VII (External Electrification Work) carried forward from pre-priced Schedule. |
| 9 | Schedule \"A\" Part-VIII (Sewage Disposal Work) carried forward from pre-priced Schedule. |
| 10 | Schedule \"A\" Part-IX (Miscellaneous Items for E/M and B/R Rate Schedule) This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \"Rs. 0.00\" under Col. 5 signifies this fact only. |
| 11 | M&L for VTPN vertical three phase distribution board VTPN, 4 way 440 volts having IP-54 isolated busbar assembly IK 09 mechanical impact strength door earthing protection, double door with provision for fixing of MCCBs as income upto 63 Amps and MCBs as outgoing complete all as specified and as directed by Engr -in- Charge. |
| 12 | Supply and fixing for 1.5 HP Water pump motor set with 25 mm delivery and 25 m head with 20-60 LPM complete set including all necessary pipe fittings and PCC foundation as required complete all as specified and as directed by Engr-in-Charge |
| 13 | Supply, installation, commissioning & testing Diesel Engine driven Generating Set with accoustics cover to control noise level as per the limit of central pollution control board Level IV, 15 KVA(minimum) at height of 9500 feet, 3 phase 415 Volt 1500 RPM 50 c/s 4 wire and power factor 0.8 complete all as specified and comparing of the following :-(a)Prime mover suitable for driving 15 KVA(minimum) alternator with electronic control governor system, radiators coolant, battery (self) and manually starting arrangement diesel engine ofradiators coolant type adequate BHP (not less than 26) conforming to latest ISS/BSS, silencer exhaust pipe extended upto outside of the DG set room and fuel tank suitable for 12 Hours consumption capacity with guage and level indicator mounted on MS frame pedestal support with anti vibration pad rated for continuous running capable of taking 10% overload forone hour in any 12 Hours operation complete taking into consideration of local environmental condition i.e. altitude/temperature etc and complete with standard accessories like starting switch, oil pressure guage, oil temp guage and hours meter etc. (b)Alternator : 15 KVA(minimum) at 0.8 PF brushless self exited, self regulated, 3 phase 50 HZ,415 V, 1500 RPM, 4 wire screen protected drip proof complete with automatic voltage regulator, output voltage regulated between + 5% or set voltage from no load to full load.© Control panelsuitable for minimum 15 KVA, 3 phase, 415 Volt DG Set consisting of the following accessories with necessary wiring :- |
| 14 | (i) MCCB 40 amps 4 pole 16 KA -01 No. (ii) Digital multifunction meter etc- 01 set. (iii) Engine fault meter to detect lub oil temperature and water temperature - 01 No. (iv)Auto/manual selector switch - 01 No. (v) LED type indicator lamp - 03 No. (vi)Push botton - 03 No. (vii) Aluminium bus bar with porcelain base, insulated with colour PVC tape of 200 amps capacity-04 (viii) Industrial type batterycharger suitable for 88 AH 24 volts DC bty - 01 No. (ix)DC Battery 12 V, 88 AH - 1 No.NOTES :-(a)Necessary foundation of installation of DG set shall be provided as per manufacturer recommondation and cost deemed to be included in the item rate quoted above.(b)Acoustic enclosure should be approved by ARAI, the nodal agency of CPCB.It should be compact, modular construction and sleek design with low noise level 75d B(A) at a distance of 1 mtr from canopy in free field conditions.It should be sound proof and environment friendly Acoustic cover should with stand extreme water conditions should be manufactured and powder coated and lined with fire proof acoustic material.It should be ready to use silent DG set which eliminates need of foundation or grouting. |
| 15 | Supply and fixed with testing and commissioning outdoor type LT cubical panel Factory fabricated CRCA Sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amp duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and property bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs. The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below the GL in PCC including a detachabale pre-drilled gland plate of thickness 3.15 mm The auxilary support of suitable SPD (surge protation Device ) protected shall be provided. |
| 16 | Note:-Design /Drawing of L.T. Panel shall be approved by Garrison Engineer.INCOMING (a) МССВ Cap 63 Amp. 4 pole, 415V, 50 c/s 36 KA-01 No (b) Copper Busbar 4 pole (three phase and one for neutral) suitable for 100 AmpOUTGOING. (a) МССВ Cap 63 Amp, 4 pole, 415V, 50 c/s 36 KA-01 No. (c)MCB TPN capacity 63 Amps, 415V, 50 c/s 16 KA-01 No. (d)MCB TPN capacity 32 Amps, 415V, 50 c/s 16 KA-01 No. (e) MCB SPN capacity 32 amp. \"C\" series-02 Nos METERING & MISC(a) Multifunction meter digital type with selector switch-01 No. Make : Secure or equivalent approved make. (b) Set of indicating lamp LED type-01 Set. (c) The panel installed such that base of panel is at least 45cm above instalation all welding,MS iron Civil work PCC1:2:4 for grouting of panel complete including excavation, earth work shall deemed in the qupted rate. |
| 17 | M& L for test Point terminal block made of gun metal or Phosphorus bronze size 75x75x25mm, drilled and screwed including 3 No 8mm dia, 25mm long hexagonal head screw, complete all as per specified and as directed by Engr-in-Charge. |
| 18 | S & F LED bldg security light fitting 35 Watt high power LED lamp, pressure di-cast 3000 Khosting with UV stabilized polycarbonate cover including driver, suitable type gasket and IP 65 portion and and fixed on pole with 25 mm dia light grade GI pipe (bend to shape) bracket 1.0 mtr longcomplete with MS flat iron clamp (clamps shall be 50 x 6 mm MS flat) nuts, bolts & washers incl painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connectioncomplete all as specified and directed by Engr-in-Charge. |
| 19 | Supply and fix 1.5 Sqmm 3 core cable, PVC insulated and PVC round sheathed, copper conductor(flexible) industrial cable, 1100 volt, confirming to IS :694 including pvc concealed conduit all as specified and directed by Engr-in-chargeNote- (i) Cable is required to be connected from junction box to LED lights with proper lugs etc. |
| 20 | Construction of conventional type LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 20 users complete all as specified and directed by Engr-in-Charge. |
| 21 | Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20 mtr dia and 3.00 mtr effective depth complete all as specified and directed by Engr-in-Charge. |
| 22 | M & L for 15mm dia 2 way bib tap with wall flange and aerator chromium plated fency type with crrutch or butter fly handle, screwed down screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engr-in-Charge. |
| 23 | S & Fbrass chromium plated Wall mixer (3 in 1) with provision of shower for mixing hot& cold Water screwed down for iron pipe 15mm bore complete all as specified and directed by Engr-in-Charge. |
| 24 | Sub Total i.e. Total of Schedule \"A\" Part-IX i.e. Serial Item No 10.00 to 21.00 |