| Sl. No. | Item Description |
| 1 | Taking down chowkats or frame with shutter, without taking off shutter from the frames not exc 1.5 Sqm each complete all as specified and directed. |
| 2 | Taking down chowkats or frame with shutter, without taking off shutter from the frames area exc 1.5 sqm but not exc 4sqm each complete all as specified and directed. |
| 3 | S&F pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C1 (20mm graded stone aggregates) for filling of pressed steel frame and hold fast block cutting etc complete all as specified and directed. |
| 4 | S&F pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C1 (20mm graded stone aggregates) for filling of pressed steel frame and hold fast block cutting etc complete all as specified and directed. |
| 5 | S&F flush shutter 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 6 | S&F 35mm thick glazed and skelton shutters open rebated and prepared to receive gauze etc (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred breds for securing glass etc sizes of members of shutters as specified in SSR Pt-I Sec 8 Clause 8.20(a) in 2nd class hard wood complete all as specified and directed. |
| 7 | M&L preparation of new wooden surface of any description and applying two coats of synthetic enamel paint over one coat of pink primer, over 10cm width or girth complete all as specified and directed. |
| 8 | Taking down window chowkats or framewithout taking off shutters(with or without glazingand ventilator) not exc 1.5 Sqm each complete all as specified and directed. |
| 9 | Providing and fixing factory made UPVC white colour Three track sliding 88x52mm, (2/4 shutter ) glass and wire mesh shutter windows, made ofreinforcement frame 60mm x 22 mm, sliding glass window sash 78mmx60mm, reinforcement sash 30mmx18 mm, sliding mesh sash 78mmx50mm, reinforcement mesh sash 26mmx10mm, sliding interlock for window and sliding glazing bead 24.5 mm x 16mm, one panel (position as directed by Engr in cahrge) will be fixed and divided in two portion fixed with 4mm thick plain clear glaas , mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware EPDM gasket 1.2 ± 0.2 mm thick, galvanised steel frame(28mm x 21.5mm), T profile (27mm x 17mm) to be inserted in required profile. Frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware Handle to slide shutter , sliding locking system and 4 mm thick glazing with selected quality glass and stain less steel wire mesh of gauge 0.56 nominal dia of wire and average width of aperture 1.18mm, complete to fix in all respect. Make: NCL VEKA ,H2O Solution, Madhu Industries or FENESTANote:- The unit rate quoted by contractor includes both glass and wire gauge shutter, cost of4 mm thick plain clear glass, stainless steel wire gauge of 0.56 nominal dia of wire and average width of aperture 1.18mm and all other connected accessories. Net Opening will be measured for payment purpose. |
| 10 | Factory made Steel windows/ventilators (Box type),with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded including one shop coat of Zinc chrome primerincluding making good disturbed surfaces of walls, complete all as specified and directed.Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Detail of box window shall be given on drawing no TD/2013/01 Sheet 1/3,2/3,3/3(iii) Wire gauze shall be measured and paid separately. |
| 11 | Factory made Steel windows/ventilators (Box type),with side hung shutters including projecting type hinges with steel handle and steel peg stay complete without glazing bars dovetailed or welded including one shop coat of Zinc chrome primerincluding making good disturbed surfaces of walls, complete all as specified and directed.Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Detail of box window shall be given on drawing no TD/2013/01 Sheet 1/3,2/3,3/3(iii) Wire gauze shall be measured and paid separately. |
| 12 | M&L Mild steel bars as in window guard bars incl necessary welding and a shop coat of zinc primer , confirming to Fe-310-O or Fe-410-O complete all as specified and directed. |
| 13 | M&L for preparation of new untreated steel or iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 14 | S&F forStainlesssteel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wirestaples complete all as specified and directed. |
| 15 | Supply and fixingacrylic transparent sheets3mm thick in square / rectangular area of each pane not exc 0.5 sqmand fixed /lock with window frame by using PVC snap beeding with necessary self tapping reviting / screwing and suitable method with and complete all as specified and directed. |
| 16 | S&F 30mm thick factory made 100% solid WPC (wood polymer composite) solid plain/prelam/enrouted plain/enrouted painted flush door shutter of required size comprising of virgin PVC resin of K value 57-60(suspension grade) calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives made from Extrusion process WPC foam sheet single extruded (inner) with density not less than 650 kg/cbm manufacture by an ISO 9001-2015 certificate company, having good screw holding capacity (screw withdrawal strength of 2000 n (face) and 1100 N (edge) minimum compressive strength of 50 n/mm2, Modulus of elasticity 850/N/mm2 and resistance of spread flame of class A category with propertyof being termite/borer free, water/moisture proof, fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headedcounter sunk SS screws for WC/bathroom/toilet/Kitchen/Balcony doors complete all as specified and directed. |
| 17 | S&F factory made 100% solid WPC (woodpolymer composite)- door frame of size45mmx85mm made from wood polymer composite (single extruded process) material comprising of virgin PVC polymer of K value 57-60(suspensive Grade), calcium carbonate and natural fibers (wood powder/rice Husk/wheat husk) and non toxic additivies fabricated with meter joints after applying PVC solvent cement & screwed with full body threaded star headed screws having minium frame density of 780Kg/cbm manufacture by and ISO 9001-2015 certified company, having good screw holding capacity (Screw withdrawal strength of (Min 990N/mm, minimum compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardent & fixed in position with SS draft fasteners/hold fast of required dia and length for external uses complete all as specified and directed. |
| 18 | S&F for 1.00mm thick factory made pressed steel shutter fixed with 1.25mm thick pressed steel frame of 105 x 60mm outer frame and as reqd for cupboards (consisting two shutters) and including 06 Nos hinges of size 100mm long and Godrej pattern three way locking system with suitable shape & size 12mm dia MS rod & 01 Nos chromium plated handle of size 150mm long with & including two coats of shop spray synthetic enamel painting over a coat of red oxide primer as colour approved by GE complete all as specified and directed. Note :1 Cupboards frame to be fixed with 06 Nos nuts & bolts of dia 12mm & 150mm long at vertical outer edge of cupboards brick wall / concrete surfaceincluding making good the disturbed surfaces complete all as specified and directed. 2 Outer to outer frontface area shall only be measured for payment purpose 3 the contractor shall provided the separate locking system for cupboard of each individuals in Barrack ,the above quoted rates shall be inclusive of this.4.For measurement purpose only opening out to out (not to girth) will be measured. |
| 19 | S&F 100 mm extruded aluminium alloy handles ,fabricated type complete all as specified and directed. |
| 20 | S&F 150 mm extruded aluminium alloy handles ,fabricated type complete all as specified and directed. |
| 21 | S & F Aluminium anodised barrel tower bolt of extruded section 200mm long complete all as specified and directed. |
| 22 | S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 23 | S&F Butt hinges 125mm, medium weight complete all as specified and directed. |
| 24 | S & F mild steel 25 mm dia drapery rod, decorative type, with PVC coating and fixed in repairs complete all as specified and directed. |
| 25 | S & F MS bracket, decorative, superior quality, suitable for 25 mm dia drapery rods, complete all as specified and directed. |
| 26 | S&F for 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 27 | S&F 300mm long mild steel ordinary rat tail rod pattern springs, including roller and roller plate in repair complete all as specified and directed. |
| 28 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingincluding 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 29 | M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including 10mm thick rendering in cement mortar 1:4backing coat for fixing complete all as specified and directed. |
| 30 | M&L, 20mm thick granite stone slabs table rubbed and polished as in cooking plate forms/ cill over and including 15 mm thick screed layer in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of stone including demolition of existing stone slabs complete all as specified and directed. |
| 31 | M&L non-skid Ceramic coloured tiles 7 to 8mm thick (square/ rectangular), area of each tiles exc 0.18 Sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes, including dismatling of existing tiles complete all as specified and directed. |
| 32 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes, including dismatling of existing tiles complete all as specified and directed. |
| 33 | M&L Glazed ceramic coloured tiles (Designer) in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4backing coat for fixing wall tiles complete all as specified and directed. |
| 34 | Demolition ofcement concrete infloors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed. |
| 35 | M&L 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) in floor complete all as specified and directed. |
| 36 | Supply only liquid type water proofing compound complete all as specified and directed. |
| 37 | Treatment of sunken floor slab comprises of the following specifications and complete all as specified and directed. :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely.40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout.(ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with liquid water proofing compound @ 200ml per 50 Kg beg of cement consumed.Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out (fixing of nozzle and grouting & WPC will be measured and paid separately).(iii)All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty (iv)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.(v) M&L for applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level+100mm height.The thickness of two layer shall be 1mm.When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (vi)GI pipe 50mm dia medium grade 50cm long laid on each sunken floor as spout complete all as specified and directed by EIC.(vii)Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with liquid water proofing compound @ 200ml per 50 Kg beg of cement consumed as per manufacturer\"s specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured and paid separately)(viii)Allpipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 type C-1 all round after painting with anticorrosive paint.Note :-(i) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above. (ii) All debries obtained from site will be thrown away out side MD land by contractor at his own expense.(iii) For payment purpose the plan area of sunken floor shall be taken into accounts. |
| 38 | M&L cement concrete 1:3:6 type C2 using 20 mm graded stone aggregate as in plinth protection, 75 mm thick, finished even and smooth without using extra cement, incl making joints 12 mm wide to the full depth of PCC at every 3 mtrs and at every change of direction and filling the same with and including bitumen and sand 1:3 by weightcomplete all as specified and directed. |
| 39 | Demolition of Brickwork built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 40 | M&L Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 41 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 in half brick complete all as specified and directed. |
| 42 | Providing and applying of 10mm thick hand applied Sika Monotop 122F single component, dual srinkage compensated thixotropic high strength formulation trawlable mortar on the brick wall including pointing of brick joint over a bond coat of sika latex (1:4:6) water cement and sika latex consumption @ 100 gm/sqm on the wall surfaces. the PMM should have compressive strength > 45 MPa in 28 days as per ASTM C 109 (7 cm cube) complete all as specified anddirected. |
| 43 | Preparing the plaster of thickness up to 15mm over the brick masonry surface by providing and applying a bond coat of Sika Latex: Water: Cement - 1:4:6 with Sika Raintite-i consumption @100gm/sqm on the wall surface followed by hand mix of cementitious mortar 1:4 to be mixed with permeability reducing polymer Sika Raintite-i @ 400gm/sqm (6%) by weight of cementitious content at time of mixing with water as per manufacturer\"s recommendations including all lead life, levelling the surface, curing etc complete all as specified and directed . |
| 44 | M&L for providing and fixing 12-16 mm dia injection ports non returnable nozzle by drilling, cleaning and sealing holes 50-75mm deep with fast setting high epoxy putty , solvent free , three component compound based on epoxy resins, graded fillers, and thixotropic agents as approved by GE as in beams, columns, slab and parapets as per the technical specifications and manufacturer\"s instructions complete all as specified and directed. |
| 45 | Supply and apply of 3 parts, very low viscous elastic polyacrylic injection resin Sika @ Injection 306 with a versatile and adjustable reaction time having mixed viscosity: 3-11 M pa s at + 20 degree C, reaction time: adjustable according to ambient temperature and execution requirement between 8-50 Mins PH - 9-10. Tested as per wissbau No 2002- 094- (1A) function test with re- injectable hose system. The holes should be drilled until a depth of approx. 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump Sika @ injection- 306@ at > 20 bar into a behind fissures or into masonry joint which are allowing water to infiltrate into unwanted area if voids is masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout when movement stop or Sika @ injection - 306 appears at the next packer move to the next packer and inject. If the dampness is heavy inject similarly at next joint line. Note: contractor will submit the warranty certificate of efflorescence for 10 years from date of completion of work complete all as specified and directed. |
| 46 | Making the grooves 10mmx10mm above coating area and fill with SIKAFLEX 127, single component, elastic, moisture curing, hybrid polyurethane based construction sealent and adhesive complete all as specified and as directed. Note: contractor will submit the warranty certificate of efflorescence for 10 years from date of completion of work complete all as specified and directed |
| 47 | M&L for 15mm thick rendering in cement mortar (1:4) on fair face of brick walls / concrete surfaces external surfaces of any description mixed with WPC @ 200ml per 50 Kg bag of cement used and finished even and smooth w/o using extra cement complete all as specified and directed. Note : WPC will be measured and paid separately. |
| 48 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 is to be fair finished (without using extra lime or cement) complete all as specified and directed. |
| 49 | M&L for 10mm thick rendering in cement 1:3on fair faces of concrete surface with fair finished in ceiling/ RCC water tank & sunshade, chajjas etc complete all as specified and directed. |
| 50 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, of any description etc complete all as specified and directed. |
| 51 | M & L for preparation of newly plastered surface of wall and applying two coats of OBD over one coat of 1mm thick wall care putty on wallcomplete all as specified and directed. |
| 52 | M & L for complete removal of existing treatment of old surface of wall and applying two coats of OBD over onecoat of 1mm thick wall care putty on wallcomplete all as specified and directed. |
| 53 | M&L for preparation newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. |
| 54 | M&L for preparation of old surfaces of wall and applying two coats of white wash complete all as specified and directed. |
| 55 | M&L for preparation newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 56 | M&L for preparation old surfaces of ceiling and applying two coats of white wash complete all as specified and directed. |
| 57 | M&L for Complete removal of existing treatment, washing down and stopping of distempered and painted surfaces by using electrical operated grinder and M&L applying two coats of exterior emulsion paint of make : weather coat of Berger / apex ultima of Asian paints / Xtrapremium of Shalimar , over and incl of a coat of exterior wall primer over two mm thick acryllic wall care puttyas approved by Manufacture complete all as specified and directed.NOTE: The work under this item shall be carried out by contractor from authorised applicator of manufacturer. The contractor shall also stand for gaurantee of the quality and finish of work under this item for period for a period of five years from certified date of completion of complete work for which an amount Rs 20/Sqm of quantity of work done under this item shall be retained in final bill .This amount shall be returned only after completion of gaurantee. |
| 58 | M&L for preparing newly plastered surface and applying two coats of exterior emulsion paint of make : weather coat of Berger / apex ultima of Asian paints / Xtrapremium of Shalimar, over and incl of a coat of exterior wall primer over two mm thick acryllic wall care putty as approved by Manufacture complete all as specified and directed.NOTE: The work under this item shall be carried out by contractor from authorised applicator of manufacturer. The contractor shall also stand for gaurantee of the quality and finish of work under this item for period for a period of five years from certified date of completion of complete work for which an amount Rs 20/Sqm of quantity of work done under this item shall be retained in final bill.T his amount shall be returned only after completion of gaurantee. |
| 59 | S&F in repair, PVC Low Level flushing cistern 10 litre capacity , valveless, syphonic action type with float ,handle ,incl 32mm dia pipe of polyethylene of low or high density or PVC & bracket complete all as specified and directed. |
| 60 | S&F in repair vitreous china squatting pan \"ORISSA\" pattern size 580mmx440kmm, white with integral foot rest including PVC\"P\" or \"S\" trap andconnection to trap including cement concrete, with PVC valveless, syphonic action type flushing cistern, low level, white with inlet, ball valve, float and handle including brackets and including flush pipe of polyethylene or low or high density or PVC 32mm dia, for low level cisternetc. including making good to floor, complete all as specified and directed. |
| 61 | S&F, 110mm dia PVC rain water pipe single socketed with rubber joint, jointed with solvent joint fixed to wall with necessary clamp incl taking down complete all as specified and directed. |
| 62 | S&F, 110mm dia PVC bend of any radius including benching in Cement concrete 1:3:6 where required and finishing , complete all as specified and directed. |
| 63 | S&F110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to ceiling & floors with necessary MS clamps incl taking down complete all as specified and directed. |
| 64 | S&F75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps incl taking down complete all as specified and directed. |
| 65 | S&F 110 mm PVC (SWR) access door bends any radiuscomplete all as specified and directed. |
| 66 | S&F 75 mm PVC (SWR) access door bends any radiuscomplete all as specified and directed. |
| 67 | S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed. |
| 68 | S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed. |
| 69 | S&F 110mm PVC (SWR) vent cowl complete all as specified and directed. |
| 70 | S&F PVC Nahani trap 75mm bore with grating incl jointing with solvent cementfixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 71 | S & F CP Peg Set of 6 , Solid Body, 200 mm to 300mm lengthand complete all as specified and directed. |
| 72 | S&F Vitreous china flat back type Wash HandBasin, white of size 550 x 400 mm including brackets & necessary fittingscomplete all as specified and directed. |
| 73 | S & F wall mounted kitchen plate rack of size 900 x 600 x 250mm made cut of 1.00mm thick stainless steel sheet of 304 AISI grade design as per directed by E in charge fixed to walls with required size of raw plug and steel screws as per manufacturer instructions of first quality in repair complete all as specified and directed. |
| 74 | S&F in repair stainless steelsink without drainage board made of stainless steel of 1 mm thick for kitchen with plugs, washer and waste pipe and waste couplingincluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 495mm x420mmandbowl size 410mm x 330mm x 160 mm, complete all as specified and directed. |
| 75 | S & F in repair CP Pillar taps 15 mm dia long size, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore all ascomplete all as specified and directed. |
| 76 | S&F in brass chromium plated waste coupling 32mm dia complete all as specified and directed. |
| 77 | S&F in repair PVC connection 15mm dia, 600mm long complete all as specified and directed. |
| 78 | S&F in repair PVC waste pipe for 32 mm dia of standard length complete all as specified and directed. |
| 79 | S&F in repair 15 mm dia CPAngle Cock, cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe or for unions 15mm bore all ascomplete all as specified and directed. |
| 80 | Supply and fixing 600mm X 450mm bevelled edge mirror of selected quality mounted on plastic frame covered back with commercial and fixed on wooden plug with chromium plated brass screws and cup washer complete all as specified and directed. |
| 81 | Taking up or down steel tubing 15mm bore from wall or ceiling of existing pipe line and removal to store complete all as specified and directed. |
| 82 | M&L for GI tubing 15mm bore fixed to walls, ceilings or laid in floors medium grade with concealedcompleteall as specified and directed. |
| 83 | Taking up or down steel tubing 20mm bore from wall or ceiling of existing pipe line and removal to store complete all as specified and directed. |
| 84 | M&L for GI tubing 20mm bore fixed to walls, ceilings or laid in floors medium grade withconcealed including taking down of existing pipe line completeall as specified and directed. |
| 85 | S&Fin repairs 15mm bore CP Bib taps Long Body Half turn/Quarter turn , cast copper alloy fancy type chromium plated and fixed complete all as specified and directed. |
| 86 | S&F 15mm dia 3 in 1 CP Brass wall mixture chromium plated fancy type for mixing hot and cold water screwed down for iron pipe and fixed in position all as specified and directed. Make: Cera Cat No. F1018401GG or ESSCO Cat No. STE-107273 or Somany Cat No 272201140011 |
| 87 | S&F brass chromium plated shower rose 125mm size fitted to steel pipe or union complete all as specified and directed. |
| 88 | S&F Rotational Moulded polyethylene Water Storage Tanks Three layers in white colour(cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position all as specifiedincluding dismantling of existing tank complete all as specified and directed. |
| 89 | S&F 20mm bore ball brass valve, high pressure with polythene float and fly nut completescrewed for iron pipe or brass ferrule complete all as specified and directed. |
| 90 | Demolition of Brick tiles or terracing tiles, single layer on roofs complete all as specified and directed. |
| 91 | Demolition Mud in roofs, any thickness, including plastering and leeping (completely removed including rubbing, washing, brooming and clean) and removing debris to MD land upto total distance 1.5 Km complete all as specified and directed. |
| 92 | M&L Providing, cement concrete Type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs/Padding in slope 1:40, rounded or chamfered on edges with mixing of water proofing compound complete all as specified and directed.Note : Water proofing compound will be paid separately. |
| 93 | M&L for applying roof treatment on top of roof with APP based polymericmembrane (not less than 3mm thick , weight not less than 3.5Kg per Sqm, reinforced with polyster non-woven fabric (weighting not less than 150 gm/ Sqm )laid by torch application method with side overlap 75mm and on end 100mmas per manufacture\"s instructions over a coat of hot paving bitumen of grade 30/40 conforming to IS 73 @ 1.2 Kg/ Sqmover a coat of bituminous primer conforming to IS -1984 @ 0.40 Kg /Sqm and and applying two coats of aluminium paint over APP membrane over and incl 15mm thick screed bed or bedding layer in cm 1:3 using liquid WPC as per manufacture instruction over RCC roof/PCC complete all as specified and directed. |
| 94 | M&L Cement concrete tiles 25cmx25cmx22mm thick machine pressed with grey cement and no pigment, set jointed and pointed in neat slurry on roof, cut and polished with grey cement and no pigment over 20mm thick bedding of cement mortar 1:4complete all as specified and as directed. |
| 95 | M&L for 100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing complete all as specified and directed. |
| 96 | M&L for Chequered cement concrete tiles 20 cm x 20 cm x 25mm thick, set jointed andin grey cement no pigment over 15mm thick screed bed in CM 1:6complete all as specified and directed. |
| 97 | M&L for colouredChequered cement concrete tiles 20 cm x 20 cm x 25mm thick, set jointed andin grey cement and pointed with pigment over 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 98 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed. |
| 99 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 100 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 101 | Demolition and breaking up drain pipes (salt glazed ware AC or RCC) set in cement mortar 150 mm dia complete all as specified and directed. |
| 102 | M&L for Concrete bed to drain pipes 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for NP2/PVC pipes complete all as specified and directed. |
| 103 | Supply and fixing Reinforced concrete pipes, 150mm dia class NP2, laid and jointed complete with collars laid in trenches or in floors complete at site all as specified and directed. |
| 104 | Cutting into existing manholes for connecting new drains, 150mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and directed. |
| 105 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation/ filling/ mass concrete complete all as specified and directed. |
| 106 | M&L for precast cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed. |
| 107 | S&F TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all as specified and directed. |
| 108 | Description all as per item No 107.00 above but6-8mm dia in stirrrups, spacers and binders etc complete all as specified and directed. |
| 109 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 110 | Demolition of RCC Roofs, floors (other than ground floors), beams, staircases, landing, chajjas upto three storey , Balcony RCC Wall, RCC water Tanks, parapet RCC Wall and similar suspended work and making good the disturbed area in CM 1:3 complete all as specified and directed. |
| 111 | M&L for cutting holes in brick walls built in cement mortar /concrete for inserting support for chajjahs/ cooler plateforms / cooler standetc and making good dismantled portion in cement mortar 1:3 or PCC 1:2:4 type B1 as required super ficial area of cutting nexc 100sqcm complete all as specified and directed.Note:-cutting of holes shall be carried out by core cutting machine |
| 112 | S&F mild steel joist ,channel ,angle ,tee fixed independently without connection plates etc (cut to ordinary length i.e. within 20mm of the length indicated ) as in frame for sheeting in chajjah complete all as specified and directed. |
| 113 | S&F prepainted galvalume alumimium zinc coating GI based plain steel sheet 0.50 mm thick of any color having tensile strength of 550 MPA as a roof covering /Cladding to wall and in Chajjah , Fixed with self tapping screw complete all as specified and directed. |
| 114 | Demolition RCC and removing all disintegrated and loose concrete of any thickness including plaster if any in roof slab, removing all loose rust / scale from exposed reinforcement bars by using wire brushes and sand paper including cleaning of exposed surfaces of reinforcement and tied reinforcement bars/IRC fabric 50mm x 50mm x 12gauge if required to reinforcement concrete bonding to exposed surfaces after treatment of rust remover and rebar corrosion protection system to existing reinforcement complete all as specified and directed.Note : The Cost for treatment incl supply and applying of rust remover and rebar corrosion protection systemto be measured and paid separately.The cost of IRC 50mm x 50mm x 12gauge or reinforcement bars also shall be measured and paid separately) |
| 115 | Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat complete all as specified and directed.Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.) |
| 116 | Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats andProduct requirements: carbonation resistance: 2 mm of chemical compoundas approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78 complete all as specified and directed.Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar) |
| 117 | Providing and applying Sika Monotop 122F single component, dual srinkage compensated thixotropic high strength formulation trawlable mortar an average thickness not less than 20mm thick on ceiling, beam and, column, joint over a bond coat of sika latex (1:4:6) water cement and sika latex consumption @ 200 gm/sqm on the RCC roof, beam, column or ceiling. The PMM should have compressive strength > 45 MPa in 28 days as per ASTM C 109 (7 cm cube) complete all as specified and as directed |
| 118 | Supply only IRC 50mm x 50mm x 12 gauge weld mesh cut to length bend to shap required and tying with and including annealed mild steel wire not less than 0.9mm or fixing with galvanised steel staples fixed to steel members with nut and bolt or fixed to RCC work or ceiling surfaces complete all as specified and directed. |
| 119 | M&L Cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and mass concrete etc complete all as specified and directed. |
| 120 | M & L for concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping, bed plates and the like including necessary formwork and finishing the surface fair and even without using extra cement complete all as specified and directed. |
| 121 | M&L for rendering 15mm thick in CM 1:4 on concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed. |
| 122 | M&L Cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate in surface channels and drain complete all as specified and directed. |
| 123 | M&L Surface dressing n exc15 cm deep in soft/loose soil complete all as specified and directed. |
| 124 | Excavation in post holes each n. exc .50 cum, getting out in soft/loose soil and removing surplus material n. exc 50 mtr and making good disturb surfaces complete all as specified and directed. |
| 125 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or otherconnecting plates complete all as specified and directed. |
| 126 | M&LPre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 127 | M&LHardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfacecomplete all as specified and directed. |
| 128 | M&L 75 mm thick Cement concrete Type D- 2, 1:4:8 (40mm graded aggregate) as in sub base of floor complete all as specified and directed. |
| 129 | M&LMachine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment over and incl 25 mm thick sand cushioning complete all as specified and directed. |
| 130 | Taking down carefully copper/ Aluminium point wiring ( light, fans, socket, power socket) complete including taking out existing unserviceable terminal boxes and conduit with switches/sockets/fan regulators and fittings such as ceiling roses, pendants, tube lights fittings lamp holders, brackets light fittings, rectangular blocks DB MCCB etc and making good disturbed surface of wall/ floor etcto matchwith the existing the surface etc complete all as specified and directed. |
| 131 | Material and labour for point wiring with 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic existing concealed conduit 19/20 mm dia medium duty, ISI marked to beterminated & including pressed modular steel boxes & cover plate of module as required on site. Including 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistrandedcopper earthcontinuity conductor controlled by one switchand/or one regulator complete including repairing the surfaces in CM 1:3 and finishingthe surface as per existing treatment complete all as specified and directed. |
| 132 | Description all as per item No 131.00 (here-in-before) but One three pin 5 Amp socket outlet point on indep board controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 133 | Description all as per item No 131.00 (here-in-before) butOne three pin 5 Amp socket outlet point on same board controlled by one nos, one way switch on same board complete all as specified and directed. |
| 134 | Description all as per item No 131.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 135 | Description all as per item No 131.00 above but point wiring with 1.5 sq mm single core FRLS cables and earth continuity wire with 1.5 Sq mm single core cable for one light point controlled by two way switches complete all as specified and directed. |
| 136 | S&F Modular switch 1 way 6A 1 module Single pole, one way, 230 volts all as specified and directed |
| 137 | S&F Modular switch 2 way 6A 1 module Single pole, two way, 230 volts all as specified and directed |
| 138 | S&F Modular switch 1 way 16A 1 module all as specified and directed |
| 139 | S&F Modular socket 6A -2/3 pin combined 2 module type 230 volts AC complete all as specified and directed. |
| 140 | S&F Modular socket 6A/16A -2/3 pin combined 2 module type AC complete all as specified and directed. |
| 141 | S&F Buzzer, Ding Dong AC 230 volts, single pole ISI marked complete all as specified and directed. |
| 142 | Supply and fixing modular bell push 6A 1 module complete all as specified and directed. |
| 143 | S&F in repair Modular lamp holder, insulated body with back plate suitable for batten fittings and complete all as specified and directed. |
| 144 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 145 | S&F in repair Modular ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed. |
| 146 | S&F in repair Modular fan step regulator 120W-2 module suitable for 1200mm/1400mm sweep ceiling fan etc complete all as specified and directed. |
| 147 | S & F in repair for wall mounted LED tube light fitting 20 watts batten not less than 120 lumen/watt for surface mounted, high transmissitivity diffuser, high lumen outputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 148 | S&F in repair Sheet metal enclosure distribution board SPN,8 way, single door powder coated, protection class IP-42 suitable for mounting MCB DBs confirming to IS-13032, IS-8632, BS5484 with min 200 Amp rating copper bus bar complete all as specified and directed . |
| 149 | S&F in repair MCBs SP 6 to 32Amps,240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note:Make of the MCB should be the same as that of DB |
| 150 | S&F in repair MCBs SPN 40Amps,240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note:Make of the MCB should be the same as that of DB |
| 151 | S&F S&F in repair Sheet metal enclosure distribution board TPN, 4 way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirming to IS-13032, IS-8632,BS5484 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers properwithPCC works complete all as specified and directed. |
| 152 | Supply and fixing in repair TPN 63 Amps, 215 volts, 16 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note:Make of the TPN should be the same as that of DB |
| 153 | S & F in repair for Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source not less than 120 lumen/watt and electronic driver of capacity 25/35 watts with pre wired andnecessary mounting arrangements and provision of 1.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including 40 mm dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed. |
| 154 | Taking down old unserviceable submain wiring including fitting & fixtures and making good of the surface to match with the existing complete all as specified and directed. |
| 155 | M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable for phase, one run of 6 sqmm cable for earthing and one run of PVC conduit will be measured as one unit. |
| 156 | Supply, laying,jointing, testing and commissioningof size 35 sqmm 3.5 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed. Note : Excavation, earth work, sand cushion & brick protection shall be paid separately. |
| 157 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion complete all as specified and directed.Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 158 | M&L for bricks covering to under gound electric cable using sub class \"B\" bricks laid dry, flat perpendicular to the direction of the cable complete all as specified and directed. |
| 159 | Supplying, filling in trenches, spreading, leveling sand cushioning 8cm below cable and 15 cm above the cable for under ground cable complete all as specified and directed. |
| 160 | Material & labour for replacement of 50mm bore GI pipe light grade lain in trenches or fixed to wll/pole for protection of cable/earthing strip etc complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail