| Sl. No. | Item Description |
| 1 | Attending complaints of leaking / unserviceable pillar cock, Wall mixer, WHB Mixer, bib taps,two way bib taps, stop valves, 15mm - 20mm dia for making it fully functional and leak proof by carefully including taking down, replacing minor unserviceable parts such as rubber washer, leather washers, jumpers brass 15mm - 20mm size complete all as directed and specified. Note: Major parts such as Spindles / phases of CP pillar cocks, wall mixer, WHB mixer,Two way bib taps,CP bib cocks , Angle cocksreplaced if any shall be measured and paid for separately under respective item. |
| 2 | Attending complaints of leaking / unserviceable , low level flushing cisterns, PVC or chinaware for making it fully functional and leak proof by replacing the defective parts such as rubber washers,PVC levers, PVC/ CP knobs if required complete all as directed and specified. |
| 3 | Attending complaints of internal water supply pipes,fittings and bottle traps for removing of blockages etc of any description inclremoving & clearing of air locks etc., bypressure pump or any other meansincluding taking down and refixing of pipes & fittings and replacing old unserviceable pipes and fitting with new ones complete all as specified and as directed. Note: New GI pipes replaced if any shall be measured and paid under respective item of this schedule as S&F. This item includes for labour part only for removal of blockages of air lock etc. |
| 4 | Hacking out old broken glass (any thickness, size, quality or scription) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as directed by Engineer in charge. |
| 5 | S&F sheet glass ordinary quality 4.0mm thick and glazing with oil putty or wooden beadsin square not exceeding 0.5 sqm in each pane complete all as specified. |
| 6 | S&F sheet glass ordinary quality 4.8mm thick and glazing with alluminium beadsin square but exceeding 0.5 sqm in each pane complete all as specified. |
| 7 | S&F sheet glass 4mm thick frosted glass, pin headed type, in square n exc 0.5sqm each pane glazing with oil putty complete all as specified. |
| 8 | Securing glass of any description in existing wooden frames glazedwith putty/ beads including removing loose or decayed putty/ beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work (New lengthof frame reputtied shall be measured) complete all as specified and as directed. |
| 9 | S&Fin repairs galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs i.e.Incl removal of old unserviceable wire cloth complete all as specified and as directed. |
| 10 | Repair to steel Vents/ Doors/ mild steel chowkats or frames/ grills / window & door shuttersby replacing unserviceable hinges ,handles , peg stay etc by way of welding etc as required , oiling to hinges,setting right and easing of shutters to functionproperly and painting at welded portion to match the existing surfaces all as specified and directed. |
| 11 | Welding in repairs exc 2.5cm but n.exc 5cm in length and metal thickness n.exc 6mm of any description and in any position complete all as specified and directed. Note: Supply only hinges etc., shall be measured and paid for separately under respective item. |
| 12 | Resecuring/ re-fixing of wooden / PVC shutters of any description and sizenot exceeding 2.00 Sqm each including taking down (if reqd), easing and adjusting and refixing where ever required and fixing new steel screws complete all as directed and as specified. |
| 13 | S&F prelaminated particle board interior grade 18/19 mm thick prelaminated one sides with decorative choice lamination as in kitchen cup boards, CB Shutters,, Shelves, partitions, any type of built-in-furniture etc. fixed with screws to timber frame work or with wooden gutties or with PVC Rawl plugs, fixed in repairscomplete all as specified and as directed. |
| 14 | S&F prelaminated particle board interior grade 18/19 mm thick prelaminated both sides with decorative choice lamination as in kitchen cup boards, CB Shutters,, Shelves, partitions, any type of built-in-furniture etc. fixed with screws to timber frame work or with wooden gutties or with PVC Rawl plugs, fixed in repairscomplete all as specified and as directed. |
| 15 | S&F block board 18/19mm thick grade 2 quality, interier grade, commercial type, fixed with screws to timber frame work fixed in repairs complete all as specified and as directed. |
| 16 | M&L second class hard wood timber framed work ie; plain fillets square, rectangular or triangular in section, wrought, bullnosed, rounded or chamferred on one edge or face complete fixed in repairs complete all as specified and as directed. |
| 17 | S&F 40 mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished fixed in repair complete all as specified and directed. |
| 18 | S&F Harrison rails of 20mm dia pipe, mild steel, chromium plated with fixing brackets, stops, rollers etc. Incl one pair of Finale/ End Cups(All as per Sample) as in curtain rods fixed in repairs complete all as specified and directed. |
| 19 | S&F mild steel 150 mm ordinary rat tail/ Helicle door springs including roller and roller plate complete fixed in repair steel chowkhats a with necessary flat iron cleat by welding or drilling with necessary nut, bolts etc complete all as specified and directed. |
| 20 | S&F in repair 150-200mm long Double action spring hinges, mild steel with steel wire spring, stove enamelled, black mild steel single action helical hinges , complete all as specified. |
| 21 | S&F mild steel sliding door bolts length 250mm, clip type/ bolt type, stove enameled black with bright bolt not less than 12 mm diawith and including a minimum of 6 bolts and nuts, four on clips and two on staple plate and fixed in repairs complete all as specified. |
| 22 | S&F aluminium anodized barrel tower bolts 200 mm long of extruded section fixed in repairs complete all as directed. |
| 23 | S&F aluminium anodized barrel tower bolts 150 mm long of extruded section fixed in repairs complete all as directed. |
| 24 | S&F aluminium anodized barrel tower bolts 100 mm long of extruded section fixed in repairs complete all as directed. |
| 25 | S&F aluminium alloy anodized, sliding door bolts 250mm long with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed in repairs complete all as specified and as directed. |
| 26 | S&F in repair extruded aluminium alloy handles, 150mm long fabricated type, anodized fixed in repairs complete all as specified and as directed. |
| 27 | S&F in repair 150mm hasp and staple, safety type, of aluminium anodisedhinge fixed with screws complete all as specified and as directed. |
| 28 | S&F in repair mild steel cold rolled, medium weight but hinges100mm size complete all as specified directed. |
| 29 | S&F mortice Locks, cupboard,grade I, size 50mmbrass with fourlevers fixed in repair complete all as specified. |
| 30 | S&F lookingMirror 600x450 mm size selected quality 5mm thick with 20mm wide aluminium angle frame all around , and6 mm thick AC building board or commercial plywood backingand fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repair complete all as specified and directed. |
| 31 | S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 23cmwide with chromium plated bracket guard and railing complete all as specified and as directed. |
| 32 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150.00mm complete all as specified. |
| 33 | Cleaning and removing all scale and dirt, etc, from tanksand from mouths of circulating pipes, etc. capacity exc 250 litres and not exc 500 litres complete all as specified. |
| 34 | Cleaning and removing all scale and dirt, etc, from tanksand from mouths of circulating pipes, etc. capacity exc 500 litres and not exc 1000 litres complete all as specified. |
| 35 | S&F in repair PVCcovers for water tanks incl hingeing device & hasp and staple for locking of capacity 500 liters to 1000 liters tanks complete all as specified. |
| 36 | S&F PVC waste pipe 32 mm to 40 mm dia size with PVC adopter oflength between 60 cm to 120 cm as per site requirementsuitable for WHBs / Sinks / urinalsetcfixed in repairs complete all as specified and as directed. |
| 37 | M&L forCP Waste fittings for 32 mm diabrass, chromium plated for glazed ware sinks, basins, etcwith long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed,fixed in repairs all as specified and directed. |
| 38 | M&L forCP Waste fittings for 40 mm diabrass, chromium plated for glazed ware sinks, basins, etcwith long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed,fixed in repairs all as specified and directed. |
| 39 | S&F in repair shower rose of 125mm with arm (195mm long with bend of 45 degree with flange) of Brass chromium plated shower rose with any colour for fixingwith 15mm pipe all as specified and as directed. |
| 40 | Supply and fixing grating of size 125 mm CP for out let of water etc complete all as specified and directed by Engr-in-Charge |
| 41 | S&F Bib taps, long body,chromium plated brass/ cast copper alloy fancy type with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrulefixed in repairs complete all as specified and directed. |
| 42 | S&F two way bib taps Chromium plated brass/ cast copper alloy fancy type with capstain head, screwed down, screwed for 15mm bore iron pipe or for brass ferrule complete fixed in repairs all as specified and directed. |
| 43 | S&F in repair Gun metal, globe or gate valve with iron wheel head/handle screwed both ends for 20mm bore irone pipe and fixed all as specified and directed. |
| 44 | S&F in repair Gun metal, globe or gate valve with iron wheel head/handle screwed both ends for 25mm bore irone pipe and fixed all as specified and directed. |
| 45 | S&F angle cock with flange, cast copper alloy chromium plated with capstain head, fancy type screwed down high pressure, screwedfor 15 mm bore iron pipe or for unions, fixed in repairs complete all as specified and directed. |
| 46 | S&F in repair nipple suitable for HDPE Water tanks minimum weight 15mm -38grms all as specified and directed. |
| 47 | S&F basin mixer (center hole) cast copper alloy chromium plated with capstain heads, fancy type screwed down high pressure, with or without letters \"Hot or Cold\" with long screwed shanks and flynut screwedfor 15 mm bore iron pipe or for unions, fixed in repairs, complete all as specified and directed. |
| 48 | S&F vitreous china wash hand basin white flat back size 550 x 400 mm including PVC waste pipe 32 mm boreand CP Waste coupling with and incl a pair of suitable mild steel brackets, fixed all in repairs, including cutting for or pinning in and making good disturbed portion as reqd complete all as specified . |
| 49 | S&F vitreous china squatting pan of Orissa patten size 580 x 440 white,front or back inlet with integral footrest including cast iron \"P\" or \"S\" trap and connection to trap and to flushing pipe,anti-syphonage pipe, etc, fixed in repair & making good to floor in CM 1:3 or Cement concrete 1:2:4 all as directed and specified. |
| 50 | S&F vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet with 1.00 to 1.50m long tube incl making connection to inlet flush pipe, & to \"P\" or \"S\" draintrap, incl supply of long special \"P\" or \"S\" trapfixed in repair complete and making good the disturbed portion etc. all as specified and directed. |
| 51 | S&F PVC valveless, syphonic action type flushing cistern, low level10 ltr capicity Dual Flush Mechanic incl, PVC flush pipe 32 mm boreand mild steel brackets of angle iron 25 x 25 x 3 mm, oval all length20 cm with red-oxide primer complete all as specifiedincl taking down any type offlushing cistern and making good the disturbed surfaces in CM 1:3 complete all as specified and directed complete all as specified, fixed in repairs |
| 52 | S&F 600 mm long PVC connection with PTMT nuts on both ends for 15mm bore pipes of approved quality complete and fixed in repair all as specified and directed, |
| 53 | S&F 450 mm long PVC connection with PTMT nuts on both ends for 15mm bore pipes of approved quality complete and fixed in repair all as specified and directed, |
| 54 | S&F plastic water closer seat, white colour, closed pattern with flat or recessed bottom, and cover and mild steel chromium plated or aluminised hinging device completefixed in repairs. |
| 55 | S&F hinging device chromium plated for plastic water closet seat suitablefor existing size and design fixed in repair complete all as specified and directed. |
| 56 | Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 57 | Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 58 | Supply, fixing, Jointing and testing 15 mm bore galvanised mild steel water tubing \"medium grade\" with and including all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 59 | Supply, fixing, Jointing and testing 20 mm bore galvanised mild steel water tubing \"medium grade\" with and including all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 60 | Fixing only 15mm bore steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 61 | Fixing only 20mm bore steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 62 | S&F rotational molded polythene water storage tanks (cylinder vertical with closed top) of capacity 500 ltrs, double walled hoisted and fixed in positionall as specified in SSR, fixed in repairs complete all as specified and directed. |
| 63 | S&F in repair 1000 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) in white colour hoisted and fixed in position including 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified. |
| 64 | S&F in repair Ball valves of 20 mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms)all as specified and as directed. |
| 65 | S&F in repair PVC bath mirror cabinate box type with shutter of overall size 450mmx350mm complete all as specified and as directed by Engineer in charge. |
| 66 | S&F in repair deco door seal bottom brush dust stopper strip aluminium plate with nylon brush for cover the bottom door gaps between 20-25mm including fixing with steel screws etc; complete all as specified and as directed. |
| 67 | S&F in repair CP health faucet with 15mm bore flexible pipe of 1.50mtr long complete all as specified and as directed by Engineer in charge. |
| 68 | Resecuring/ re-fixing of Aluminium door/ window/ vents of any description and sizeby taking down shutter from frame, opening out joints after taking down glass or particle board, replacing the corner piece & defective section members jointing again refixing the glass pane/ particle board etc and complete all as specified and directed by engineer in charge. Note: (i) Floor spring , door closer , lock , glazing , rubber gasket , aluminum glazing , defective aluminium part, and aluminium beading measured & paid seprately. |
| 69 | S&F for Door closerAluminium (Die cast) body, hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 1000mm to 1200mm in width and of weight between 61 to 80 kg and fixed complete. |
| 70 | S&F for Mortice lock, vertical type, size 100 mm 4 levers brass with two No\"s key etc; complete all as specified and as directed |
| 71 | S&F in repair top pivot in aluminium door and fixed complete all as specified and as directed |
| 72 | Dismantling glazed tiles/ kota stone/ terrazzo tiles any type as in dado/ skirting etc; including cement mortar bedding ( but not backing ) complete all as specified. |
| 73 | M&L for Vitrified ceramic tiles 10mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed. |
| 74 | M&L for Vitrified ceramic tiles 10mm thick (square/ rectangular) as in skirting / dado, cut out of ceramic tiles of size not exceeding 0.36 sqm, (Matching with floor tile of the same room) set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed. |
| 75 | M&L for non skid ceramic coloured tiles of approved shade and pattern, 7 to 8 mm thick , area of each tile exceeding 0.06 sqm but not exceeding 0.18 sqm laid in floor, set and jointed (square/ rectangular) in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 76 | M&L for glazed ceramic coloured tiles of approved shade and pattern of size 350x 250x7mm/ 450X350X7mm/ 300X450X7 to 8mm thick or any other nearer size as approved by Engineer in charge in vertical surface set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles complete all as specified and as directed. |
| 77 | M&L in repairs for 16 -18mm thick granite (colour as approved) work (table rubbed and polished) in steps, shelves, jambs, pillars, window-cills, cooking platforms (vertical/ horizontal) and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 10mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed. |
| 78 | Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and as directed |
| 79 | M&L for rendering 15 mm thick in CM 1:6 over stone masonary, concrete surfaces, finished even and smooth (without using extra cement), all as specified and as directed. |
| 80 | M&L for 15 mm thick rendering on stone masonary wall surfaces in CM 1:4finished fair and even all as specified and as directed. |
| 81 | M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 82 | Preparing new plastered surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsioncomplete all as specified andas directed. |
| 83 | Preparing new plastered surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of cement base paint complete all as specified andas directed. |
| 84 | Preparing of old painted wooden surfaces or wood based material of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 85 | Preparing old painted steel surfaces or iron work of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified andas directed by Engineer incharge. |
| 86 | Complete removal of existing treatment by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of distempered or painted surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on old treated surfaces of walls complete all as specified and directed by Engr in charge. |
| 87 | Preparing old plastered surfaces brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of distempered or painted surfaces and M&L for applying onecoat of distemper oil emulsion on old plastered surfaces all as directed by Engr in charge. |
| 88 | Preparing old plastered surfaces brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil or greasy spots incl washing rubbing down and stopping of distempered and painted surfaces and M&L forapplying one coat of cement base paint on walls etc.,complete all as specified and as directed. |
| 89 | Preparation of old decorated plastered surfacesincl brooming surfaces, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil or greasy spots incl washing rubbing down and stopping of distempered/ lime wash and painted surfaces and M&L forapplying one coat of white wash on walls etc.,complete all as specified and as directed. |
| 90 | Preparation of old decorated plastered surfaces brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil or greasy spots incl washing rubbing down and stopping of distempered/ lime wash and painted surfaces and M&L forapplying one coat of white wash on ceiling etc.,complete all as specified and as directed. |
| 91 | M&L for washing, rubbing down and stopping of old decorated plastered or unplatered surfaces of walls, facia, chajja extra and applying one coat of exterior emulsion paint (weather proof) incl necessary repair work with putty or plaster with preparation of new surface complete all as specified and directed by Engr-in-charge |
| 92 | Preparation of newplastered surfaces of ceiling etc. & applying three coats of limewhite wash on ceilingcomplete all as specified and directed by Engineer-in-Charge. |
| 93 | Preparation of old decorated surfaces incl brooming surfaces, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil or greasy spots incl washing rubbing down and stopping of distempered/ lime wash and painted surfaces and M&L forapplying one coat of white wash on walls/celing etc.,complete all as specified and as directed by Engineer-in-Charge. |
| 94 | Preparation of old decorated surfaces with brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil or greasy spots incl washing rubbing down and stopping of distempered/ lime wash and painted surfaces and M&L for two coats of 100% remium acrylic emulsion paint having VOC less than 500 gm/litre and UV resistance as per IS 15489:2004 Alkali & fungal resistance dirt exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat exterior primer primer primer applied@ 0.90 litre/10 sqm.Note - primer and emulsion to be carried out through air less spray machine ( Mechanical means)Smart perodical, complete all as specified and directed by Engineer-in-Charge. Note: The work for periodical services shall includes the following and the rates quoted by the bidders shall includes the same :-(a) Use of scafolding, trestles, ladders, cradles etc necessary for execution of work and protective measures.(b) Removal of nails, making good holes, cracks etc.(c) Work in patches and in nerrow/width, bands, cornices, pilasters etc and cutting in edge of line where necessary.(d) Spreading and removing covering to doors, windows, floors fittings, wiring etc to protect from splashes.(e) Washing floors, cleaning glass, joinery, electric fittings, wirings etc. Drops and splashes of paint to be cleaned to the entire satisfication of Engineer-in-Charge.(f) Sample patche of 10 sqm be prepared considering the sample of periodical and shall be got approved from GE prior to carrieng out further work.(Periodical servises shall be executed through authorised applicators of approved make.) |
| 95 | M&L French polishing on surfaces of any description, width or girth including cleaning & preparing the surface including a coat of wood filler on old works with one or more coats |
| 96 | M&L for writing letters or figures etc. (block, Roman, Italic or Indian) n. exc 30 CM high with paint to match existing work complete all as specified and directed by Engineer-in-Charge. |
| 97 | Taking down carefully aluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. |
| 98 | Taking down carefully UNSV main switch and DB\"s including MCBs of any size make, type and capacity omplete all as specified and directed. |
| 99 | M&L for point wiring (Concealed modular) complete for one light point / fan point / exhaust fan point / bell point controlled by one 1-way switch / bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. Make of Wire : KEI / Havells //Polycab. Note : 1. The cost of modular type Metal flush boxes and modular accessories like inner/outer cover plates etc is deemed to be included in quoted rate. 2.The cost of cutting chases on wall and making good surface on wall are deemed to be included in the quoted rate |
| 100 | All as per srl item no. 03 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board. |
| 101 | All as per srl item no. 03 here-in-before but for one socket outlet 3 pin, 5 Amps on same board. |
| 102 | All as per srl item no. 03 here-in-before but with single core multistranded cable of size 4.0 sqmm for one 15 Amp sockets outlet on independent borad and multistranded insulated copper earth continuity conductor of size 4.0 sqmm all as specified and directed by Engr-in-Charge |
| 103 | S & F in replacementModularswitch1way 6A , 1module size complete all as directed.Note:Make ofModular switches / sockets and other accessories : MK(by Honeywell) / Legrand (Myrius) / Havells (Crabrtee) |
| 104 | S & F in replacementModularswitch1way 16A , 2module size complete all as directed. |
| 105 | S & Fin replacement Modular Bell push way 6A with 2 module size with indicator complete all as directed. |
| 106 | S & Fin replacement ModularSocket , 6 A , 3 Pin , 2module size complete all as directed. |
| 107 | S & F in replacementModularSocket , 6 A / 16 A , 3 Pin , 2module size complete all as directed. |
| 108 | S & F in replacement of modular type fan regulator 2 module A/C 240 Volts. |
| 109 | S & F in replacement electronic dimmers, 450W, 240V flush type on the exiting phenolic laminated sheet etc. as reqd. |
| 110 | M&L point wiring (Concealed Normal) complete for One light / fan / bell / exhaust fan point controlled by one no, 1-way, 5 Amps switch. with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casingand cappingof 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl concealed MS sunken box of suitable size flush with wall surface, covered with & incl 3 mm thick bakelite, laminated hylem sheet / Gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed for the following :-(Note :The cost of MS sunken box with 3 mm thickbakelite, laminated hylem sheet top cover is deemed to be included in quoted rate.)Make: KEI / Havells /Polycab |
| 111 | All as per srl item no. 110 here-in-before but for One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch. |
| 112 | All as per srl item no. 110 here-in-before but for One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch. |
| 113 | All as per srl item no. 110 here-in-before but with 2.5 sq mmFRLS copper wire with 2.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point. |
| 114 | M&L point wiring from UPS to switch board or any device/equipment complete with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 2.5 Sqmm 1100 volts grade for phase and neutral with incl 2.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies/equipment etc at one end and to UPS earth point at other end, complete wiring drawn through & PVC casingand cappingof min 20 mm (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc complete all as per site requirement.Make: KEI / Havells /Polycab |
| 115 | S&F in replacement of Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal |
| 116 | S&Fin repairs Socket, two-in-one, 5 pin, 5 Amp, universal type, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal |
| 117 | S&Finrepairs Switch piano type, single pole, one way, 15 amps, 230 volts, complete all s specified and directed. Make : SSK / Havells (Reo)/ Gold Medal |
| 118 | S&Fin repairsSocket, 6 pin, 5/15Amp, multipurpose shutter type, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal |
| 119 | S&F in repairs resistance type Fan regulator A/C 240 Volts. Make : Gold Medal / Havells (Reo) / SSK |
| 120 | S&Fin replacement of Bell push, flush type 5 amps, 230 volts. Make : SSK / Havells (Reo) / Gold Medal |
| 121 | S&Fin replacement of electric call bell ding dong AC 230 volts Single Pole.Make : Gold Medal / Havells / Crompton |
| 122 | S&F of modular Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.Make : Havells / SSK / Gold Medal |
| 123 | S&Fin replacement of Lamp holder, metal cased, bakelite body, 230 volts, with 9W LED lamp complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal |
| 124 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 125 | S&F of LED light fitting 1 X 20/22 watt (4 feet), decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. |
| 126 | Supply and fixing LED emergency batten lights fitting 10 watt,220v AC with high quality polycarbonate and translucent serrated milky white diffuser to get glare free, smooth light distribution , thermoplastic/aluminium housing enhances safety and luminaire is pre-wired with high efficiency electronic driver and LED lamp, power backup of 3 to 4 hr including up with three core flexible copper conductor cable suitable size complete all as specified and directed. |
| 127 | Supply and fixing LED emergency batten lights fitting 20 watt,220v AC with high quality polycarbonate and translucent serrated milky white diffuser to get glare free, smooth light distribution , thermoplastic/aluminium housing enhances safety and luminaire is pre-wired with high efficiency electronic driver and LED lamp, power backup of 3 to 4 hr including up with three core flexible copper conductor cable suitable size complete all as specified and directed. |
| 128 | Supply and fixing in replacement round/square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete electrical connection all as directed. |
| 129 | S & F in replacementLED light fitting 1X10 Watt bulk head luminaires including LED light driver holder and wire mesh guard connecting up with three core flexible copper conductor cable of suitable size incl all electrical connection complete all as directed. |
| 130 | S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 131 | Taking down old existing unsv ceiling fan and Supply and Fix BEE 5 Star rating(BLDC) Brushless direct current motorCeiling Fan 1200mm sweep,Min air delivery 210 CFM with service value 6.00 BEE , complete with down rod and 3 core 1.5 sq. mm copper conductor cable incl electronic fan regulatorfrom ceilingrose to fan complete with all accessories an suitable size fordown Rod230V,Make- Bajaj/ Crompton / Havells / Orient |
| 132 | Taking down old existing unsvfan and S&Fplastic ventilating fan 200 mm sweep plastic body including louvers with cutting chases on brick wall and grounting with nut bolts on aluminium frame complete all as specified and directed. Make : Bajaj/ Crompton / Havells / Orient Note : Rates are deemed to be included for cutting chasing on wall or window, grouting with nut bolts etc |
| 133 | Taking down old existing unsv fan and S&F exhaust fan 300 mm sweep steel body including louvers with cutting chases on brick wall and grounting with nut bolts on aluminium frame complete all as specified and directed. Make :Bajaj/ Crompton / Havells / Orient Note : Rates are deemed to be included for cutting chasing on wall or window, grouting with nut bolts etc |
| 134 | Taking down old existing unsv fan and Supply & Fixing in replacementwall mountingfans 230 volts single phase oscillating 400 mm sweep complete all as specified and directed by Engineer-in-Charge. |
| 135 | S&F of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 08 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.Make : Havells / Schneider Elect / Legrand / ABB / Hager |
| 136 | Supply and fixing double doormanufacturer MCB DB TPN 04 way flush in wall comprising of sheet metal enclosure powder coated fitted with bus bar 250 Amps 415 volts. |
| 137 | S&Fof MCB, C Curve type, 25 kA, 63 Amp to 100 Amp, TPN with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / ABB / Havells |
| 138 | Supply and fixing MCCB FP 125 Amp, 25 KA C Curve 415 volts. |
| 139 | S&Fof MCB, C Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / ABB / Havells |
| 140 | Supply and fixing in repair 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection. Make : Schneider Elect / Legrand / ABB / Havells |
| 141 | Taking down old sub main wiring and M&L for concealed sub main wiring with 2 run of 16 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 16 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : Tworun of 16 Sq.mm. and one run of 10 Sq.mm (earth wire) cableincuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces. Make of wire : Finolex/Havells/KEI, Make of PVC conduit : Finolex/Modi/Polycab. |
| 142 | All as per srl item no. 142 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with one run 6 Sqmm FRLS copper cable as earth wire. |
| 143 | All as per srl item no. 142 here-in-before but with 2 run of 4.0 sq mm FRLS copper wire with one run 4 Sqmm FRLS copper cable as earth wire. |
| 144 | M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed. |
| 145 | Taking down ceiling fan, exhaust fan, wall mounting fan etc of any make, type & sweep including checking the serviceabilty of ceiling fan, exhaust fan, wall mounting fan, Padestal fan etc in the presence of MES representative, transporting the same to work shop and refixing the same after replacing of unserviceable parts all as directed by Engr-In-Charge.Note : Any unsv parts reqd for replacement shall be measured and paid separately under respective item of Schedule as supply only. |
| 146 | M& L Dismantling and removing old burnt copper wire winding of ceiling fans upto 1400 mmsweep of any make and rewinding with new enameled super copper wire of existing gauge as per old copper winding incl providing insulation by varnishing (golden), cleaning, oiling, greasing etc all as specified and directed by Engr-in-Charge. |
| 147 | All as per Item No 146as above but for Exhaust fan of 300 mmsweep of any make. |
| 148 | Supply only PVC exhaust fan motor in replacement of old unserviceable burnt motor for any type size and make complete all as specified and directed |
| 149 | Supply only capacitor for ceiling fans / exhaust fan / Cabin fan / Table fan ofcapacity upto 4.0 mfdISI marked complete all as directed |
| 150 | Supply only Ball bearing for any type of ceiling fan. Make:- SKF/NBC/TATA |
| 151 | Supply only Ball bearing for any type of exhaust fan, Make:- SKF/NBC/TATA |
| 152 | Supply only MS clamps (Standard size) with rubber real with MS nut, bolts, check nut & split pin complete. |
| 153 | Supply only canopy for ceiling fans. Make:- Usha/Khaitan/Crompton |
| 154 | Supply only fan blade for ceiling fan of any type & size.(set of three ) Make:- Usha/Khaitan/Crompton |
| 155 | Supply only fan blade for Exhaust fan of any type & size. |
| 156 | Supply and fixing in repair single pole and neutral enclosure with a three pin and earth plug and socket complete with one single MCB SP 20 Amps. Make Legrand / C&S / Havells |
| 157 | Supply and fix in replacementheating element including rubber ring, washer, holding clamps and nuts ofcapacity upto 2 KW complete all as specified & directed. Make : Bajaj/Recold |
| 158 | Supply and fix in replacement thermostat of temperature variating ranging from 25° centigrade, suitable for upto 25 litre capacity geyser complete all as specified & directed.Make : Bajaj/Recold |
| 159 | Supply fix inreplacement PVC connection (heavy duty) of 15 mm dia with required length with 2 Nos of brass, chromium plated nuts of approved make & quality complete all as specified & directed. |
| 160 | Supply and fix in replacement safety valve ISI marked complete all as specified & directed. |
| 161 | Supply and fix in replacementpressure realizing valve fo size 15 mm dia.complete all as specified & directed. |
| 162 | Supply and fix in replacement geyser bottom and top plate suitable for geyser of any make, size & type duly painted 25 ltrs capacity complete all as specified and directed by Engr-in-charge. |
| 163 | Supply and fix in replacement of indicator lamp assembly for geyser complete all as specifed and directed by Engr-in-charge. |
| 164 | Servicing/maintenance/Repair of DG SET of 200KVA installed at DAD Complex forrepair/replacment of the following components all as specified and directed by Engr-in -charge.(a) Checking water temperature safety control (b) Checking and correcting impeller of water pump for excess play.(c) Checking and correcting turbocharger, any oil leakage,tightening of mounting screws and nutsetc.(d) Cleaning,tightening all electrical connection of engine (e) Checking and cleaning of generator bushes(Alternator) andcommutator(f) Cleaning of entire engine.(g) Checking exhaust and inlet manifold bolts and capscrew (h) Checking engine blow by(j) Cleaning of radiator inside and outside by removing and refixing after cleaning. (k) Checking and adjusting injector and valves.(l) Cleaning fuel inlet connections and screw, (m) Checking of oil. (n) Replacing of radiator hoses of different sizes with clamps(o) Checking of vibration damper Note : Any following item required for servicing / preventive maintenance will be measured and paid separately under respective items |
| 165 | -Ditto- as above item No 164 but for 50 KVA DG Set |
| 166 | Supply only(a)Oil filter suitable for 200 KVA DG set |
| 167 | (b) Oil filter suitable for 50 KVA DG set |
| 168 | (c)K-Oil Super suitable for 200 / 50 KVA DG set |
| 169 | (d)Fuel Filter suitable for 200 / 50 KVA DG set |
| 170 | (e)Set of hose suitable for 200 KVA DG set |
| 171 | (f) Element suitable for 200 / 50 KVA DG set |
| 172 | (g) Element air cleaner suitable for 200 / 50 KVA DG set |
| 173 | (h)Supply only V fan belt suitable for Gen Set 200 / 50 KVA |
| 174 | (j) Coolant |
| 175 | Dismantling the PT/FI pump assembly, repair / overhauling / calibrating in authorised lab including replacing tornoutrings,plunger,damper plate gasket etc. including, refixing, reconnecting, testing & commissioning complete as specified and directed. |
| 176 | Supply and fixingup to 150 AH,12V maintanances free battery for DG set Make: Exide/Amaron or equivalent |
| 177 | Maintenance, servicing and testing of split type/window type AC, capacity upto 2 Tons, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters cleaning with VINICLEAN solution using pressure jet system with water , checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensuretaking down and refixing in position complete all as directed by Engineer-in-Charge.Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor. |
| 178 | Taking down Split/Window AC including refrigent gas recharge/suction in outdoor unit dismantling inner and outer unit and piping with electric wiring carefully and shifting of existing split/window AC from one place to other place and refixing same in different place and position complete including recharge of refrigerant gas and connecting proper electricty supply connection and testing after installation for smooth working all as per direction of Engr-in-Charge. |
| 179 | S&F, in replacement compressor for split type AC 1.5/2 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed.Make: Shriram/ Kirloskar/Voltas/Carrier/Whirlpool |
| 180 | M&L for finding out leakage with the pressure testing of the condensor/cooling unit/ compressor of window type/Split type AC of 1.5/2 Toncap including dismantling the same for recharging with R-22 gas or as per manufacturer\"s instruction and stop leakage by brizing/soldering including charging the gas to required level and testing the AC for the entire satisfaction of EIC. |
| 181 | S&FNylon type filter pad20 micron for window type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed. |
| 182 | S&F in replacement running capacitor 5 MFD 230 volts for blower motor complete all as specified and directed. Make : Keil / Asian /Tesla. |
| 183 | Supply and fixing in replacementstarting capacitor clip type of cap. 80-100 MFD,440 suitable for 1.5/2 Ton capacity window/Split type AC complete all as directed by Engineer-in-Charge make- Kell/Tesla/Sharda/Escop |
| 184 | S&F in replacement ofrunning capacitor, 36/45/50 MFD suitable for 1.5 / 2.0 Ton capacity window/split type AC of approved make. |
| 185 | S&F in replacement ofindoor unit complete set suitable for cap upto 1.5 Ton capacity Make : Voltas / Whirlpool / Blue Star |
| 186 | Supply and fixing in replacement, external/outdoor unit complete including compressor for split type AC 1.5 Ton capacity, complete all as specified and directed |
| 187 | S&F, in replacement, starting relay suitable for split type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol |
| 188 | S&F, in replacement, condensing fan motor 1/8 HP, single phase suitable for split type AC up to 2 ton capacity including testing complete all as specified and directed. Make: Khaitan or Universal. |
| 189 | S&F, in replacement, power circuit breaker (PCB) kit for split/window type AC complete all as specified and directed. |
| 190 | S&F in replacement drain out pipe of split type AC complete all as directed by Engineer-in-Charge. |
| 191 | S & F single phase preventor with accessories suitable for electric motor 5-15 HP capacity with necessary electrical connection by using proper size of single core copper wire complete incl taking down/ removing old U/Swith necessary electrical connection complete as directed. make :Minilec Cat No-VSP1 AST/ L &T/Simens |
| 192 | Supply and fixing Analog voltmeter 0-500volt rage of size 2.5x2.5\",3 phase, 415 voltsuitable forthe LT Panel board where directed including taking out old burnt out Voltmeter including electrical connection withsuitable size of copper wire complete all as directed & specified , Make:L&T/ AE/MECO or Equiv |
| 193 | Supply and fixing digital Ammeter 0-150 Amps of size 4x4\", capacity ,3 phase, 415 volt with operating voltage 210 Vnos suitable forthe LT Panel board where directed including taking out old burnt out Ammeter including electrical connection withEsuitable size of copper wire complete all as directed & specified ,Make:L&T/ Schenider / HPL ,cat no-PAMEBRITA 32 or Equiv |
| 194 | Supply and fixing Indicator assy 3 pcs per set suitable for 230 volt matching with exisisting one forthe LT Panel board where directed including taking out old U/S indicator assy including electrical connection withEsuitable size of copper wire complete all as directed & specified , Make:AE/ HPL or Equiv |
| 195 | Material & Labour for taking down unserviceable mono block pump-motor of upto 10 HP capacity from foundation, dismantle the pump- motor for servicing / replacement of unserviceable bearing, gland bush, and rewinding of motor, reassemble after repair / servicing reinstall on existing location & testing on full load complete after completion. |
| 196 | Taking up / down old GI tubing connection including clearing (from trenches/wall/roof) 25/50 mm bore complete as directed by Engr-in-Charge. |
| 197 | Supply & laying steel Tubing galvanized medium grade (ISI Marked) 25 mmbore and tube fittings ISI marked laid in trenches allas specified and directed by Engineer-in-Charge. |
| 198 | Supply & laying steel Tubing galvanized medium grade (ISI Marked) 32 mmbore and tube fittings ISI marked laid in trenches allas specified and directed by Engineer-in-Charge. |
| 199 | Supply & laying steel Tubing galvanized medium grade (ISI Marked) 50 mm bore with all fittings ISI marked laid in trenches allas specified and directed by Engineer-in-Charge. |
| 200 | Supply & Fixing in replacement Glob or Gate valve, 25 mm bore, gun metal, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 201 | Supply & Fixing in replacement Glob or Gate valve, 32 mm bore, gun metal, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 202 | Supply & Fixing in replacement Glob or Gate valve, 50 mm bore, gun metal, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 203 | Material and labour for rectification of leakage of UG water pipe lines of size upto 50 mm Bore of any description such as CI/DI/GIpipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable Clips,flanges, Joints or any other material complete all as specified and as directed by Engineer-in-Charge |
| 204 | M&L fornew valve chamberof size 900x900x900mm internal dimensionincluding necessary earth work excavation with earth work on any type of soil, PCC M-10 type C-2 as in foundation, brick work in CM 1:4, 15 mm thick plaster in CM 1:4internally and externally, flush pointed in same mortar as work proceeds, 75 mm thick PCC coping all round (M-15 with 20 mm aggregate), flooring shall be 40 mm thick PCC M-15 (Nominal mix) laid over 75 mm thick hard core.Top cover shall be made out of MS sheet 3.00 mm thick fixed in angle iron frame made out of angle iron size 40x40x6 mm with two number of hinges on one side and locking arrangement at other side complete including painting withtwo coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified. |
| 205 | M& L for cutting existing GI pipe line dia 50/80 mm and inserting valve of 50 mm including other accessories as per requirement andjointing matterials all as directed |
| 206 | Excavationin trenches nexc1.5 m wideand nexc1.5m in depth and getting out in soft /disintegrated rock laying of pipes/cables etcas directed by by Engr-in-Charge. |
| 207 | Returning, filling in Soft/ loose soils including spreading, levelling, watering and well rammingin layers not exceeding25 cm thick each all asdirected by Engineer-in Charge. |
| 208 | Removing surplusexcavated rock to a distancenot exc 50 manddepositing where directedat a level n.exc. 1.5 m above the starting point complete all as specified and directed. |
| 209 | Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge. |
| 210 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core Complete all as sepcified and directed by Engineer-in-Charge. |
| 211 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 CoreComplete all as sepcified and directed by Engineer-in-Charge. |
| 212 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5CoreComplete all as sepcified and directed by Engineer-in-Charge. |
| 213 | Supply and laying un-reinforced precast concrete cable cover , class LV type flat size 250 mmx150mmx40 mm for protection of underground cable in trenches complete all as specified. |
| 214 | M &L for dry clean fine river sand as in sand cushioning to undeground cableincluding punning down of sand with layer of sand 8 cm thick before laying of cable and 15 cm after laying cable in trenches all as specified and directed Note:- Punned thickness shall only be measured and paid. |
| 215 | S&F in replacement of DOL starter in sheet steel enclosure type MK-1 suitable for motor 3 phase, 415 Volts 5/7.5 HP complete all as specified and directed by Engr-in-Charge. |
| 216 | S&F in replacement Bldg security LED light luminaire of 35 watt having IP 65/66 protection fitting of pressure die cast aluminium housing, operating voltage 140 V to 240 V with in built surge protection, touughned glass with fixing on GI bracket/pipe with 40 mm bore including drilling, holding nuts & bolt 2 coat of red oxide paint on GI pipe and fixing with wall security light on building wall complete all as specified and directed by Engr-in-charge. |
| 217 | S&F in replacement StreetLED light luminaire of 60 watt having IP 65/66 protection fitting of pressure die cast aluminium housing, operating voltage 140 V to 240 V with in built surge protection, touughned glass with fixing on GI bracket/pipe 40 mm bore including drilling, holding nuts & bolt 2 coat of red oxide paint on GI pipe and fixing with wall security light on building wall complete all as specified and directed by Engr-in-charge. |
| 218 | Supply and fixingin replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp incl electrical connection all as directed |
| 219 | Supply and fixing in replacement post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete with all electrical connection all as directed. |
| 220 | S&F of GI pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wallincluding painting with two coats of aluminium paint over a coat of red oxide paint complete all as directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate. |
| 221 | S & F Street light poles painting with two coats of aluminium paint over a coat of red oxide paint and writing pole Nocomplete all as directed by Engineer-in-Charge. |
| 222 | Supply and fixing security light termination box, weather proof, along with connector for 3 phases and MCB SP 6 Amps incl 4 aluminium strip bus bar mounted on insulator of size 200x250x150mm complete all as specified and directed by Engineer-in-Charge .Make : Sintex / Hensel |
| 223 | Taking out existing Cable and S&F 3 core, 2.5 sqmm PVC insulated sheathed multistranded flexible copper conductor cable drawn through pvc conduit pipe from junction box to fitting complete all as directed. Make: Havells / Finolex / Polycab |
| 224 | M&L for RCC 1:2:4 type B1 (using 20mm graded aggregate) as in foundations,including rafts,footings,foundation beams,plinth beams, bases for columns, etc; basement slabs, under-reamed piles and mass concrete for steel pole including necessary formwork complete all as specified. |
| 225 | M&L for maintaining entire power house/ sub station area at DAD area and proper cleaning of surrounding and inside area of shrubs grases, bushes and other greenery which affect the installation and operation in every three monthNote:- (i) It is the responsibility of Contractor totake Power house shutdown with prior premission from dept.(ii) Contractor should arrange all required T&P for cleaning of sub station. |
| 226 | Supply, laying, testing and commissioning of semi conducting compound conductor screened PVC bedded galvanized steel strip or wire armoured XLPE insulated heavy duty 11000 Volts grade with stranded aluminium conductor of size 95 Sqmm x 3 core confirming to IS 7098 Part-II, suitable for earthed system complete all as direcrted. Make : Havells/Polycab/KEINote : 1. The end termination joint shall be measured and paid separately under respective items.2. Excavation, earth work, sand cushioning and protection cover will be measured and paid for separately. |
| 227 | Supplying and laying unreinforced precast cement concrete cable covers,ISI MarkedClass HV, Flat, Type - 1, of size 300 mm X 180 mm X 40mm in trenches for cable protection, embossed with \"ELECTRIC\" on the top surface complete all as specified and as directed by the Engineer - in - Charge. |
| 228 | Supply jointing and testing outdoor type cable end termination joint (Heat shrinkable) suitable for aluminium conductor cable of size 95 Sqmm x 3 Core, 11000 Volts grade, complete all as directed.Make : Raychem/Densons/M seal |
| 229 | Material and Labour for heatshrinkable HT, 11 KV , outdoor type, cable straight through joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core,50 to 95 Sq.mm, XLPE Cable including jointing materials etc complete all as specified and as directed byEIC Make : Raychem/Densons/M seal |
| 230 | Dehydration/filtration of transformer oil of Transformersof various capacities installed at DAD Sub Station by disconnecting plants electrically for recirculation existing transformer oil and dielectric strength is should be above 50 KVNote- :- (I) Test result will be recorded before & after filtration of oil.(ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.(iii)Transformer oil for topping up will be measured and paid in relavant item as required. |
| 231 | Supply andFilling Transformer Oil of good quality for Topping Up transformers 400 KVA having dielectric strength not less than 50 KV , flash point not less than 135 degree C , having low viscosity for filling or replacing the old oil complete all as specified and directed by Engr in Charge. Make - Servo / Power Oil / HP |
| 232 | M&L for dry, blue colour silica gel crystal impregnated with cobalt suitable for transformer breather complete, all as specified and directed by Engr-in-Charge. |
| 233 | M&L for attending No supply complaint for LT supply in residential accn and Office area at DAD with proper checking of all circuit and rectified complaint and checking of proper voltage inculding all required equipment/devices, minor repair/replacement etc.Note:- (i) Any major repair /replacement of parts are measured and paid in separate relevant item of this schedule.(ii) Contractor have to arrange all required T&P for attending complaint. |
| 234 | M&L for attendingHT supply breakdown related complaint of HT no supply, HT tripping and any other problem to HT supply at DAD area with taking prior premission from the department for shutdown of HT supply and discharge the HT line proper with safety equipment/devices by skilled insured electrician and rectified complaint within 2 hrs.Note:- (i) Taking proper shutdown with premission of dept is the responsibility of contractor.(ii) Above quoted rate are inclusive of all required tool and plant and minor repair parts etc. |
| 235 | M&L for arrangement ofcomputrised PULSE GENRATOR fault detecting machine for HT cable of any size for tracing HT cable fault and making proper joint with incl earth work complete all as directed.Note:- (i) HT joint are paid and measured separataly in relevant item of this schedule.(ii) Contractor take shutdown with prior premission from dept(iii) Cost of excavation, returning filling are inclusive in above quoted rates. |
| 236 | M&L for disconnection of transformer from HT power supply, check all leakage portion at Transformer and clear all leakage to repair / replacement of gasket sheet or necessary welding if required includingelectric load balancing for 500 kVAtransformer complete all as specified and directed by Engineer-in-Charge.Note :Necessary required gasket sheet or gas welding are included in quoted rate |
| 237 | Dismantling & taking down of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. |
| 238 | Supply & install 11 KV 3 Phase Gang operated air break switch with drop out fuses set (consisting 12 Nos Post Insulator ) 400 amp capacity, vertical mounting with fixed and moving contacts complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, all as specifed and directed.Make - Jaipuria / Rashtriya / Petco |
| 239 | M&L for preparing old painted steel or iron surfaces of LT Panel of any size and description by cleaning dirt, oil, grease etc, removing the old paint, rust by scratching with wire brush / emery paper etc, with and incl repairing/refixing of existing panel doors with hinges, by using of gas welding or fixing new panel door of same size and shape made of 2.0 mm thick steel sheel, as per site requirement, with and incl all kind of machine work i.e. cutting, bending, pressing, threading, welding, jointing etc, after disconnecting LT electric connection and apply two coat of synthetic enamel paint over one coat of red oxide primer etc and making all electric connections and testing the same, complete all as specified and directed by Engr-in-Charge. |
| 240 | M&L for disconnecting and taking out existing HT 11 KV VCBfrom housing and cleaning, rubbing and servicing the mechanical parts inclTrip coil, Breaker charging motor ,Gear Panion, roller Switch, Big gear etcand re-assembling the sameas required and ,make the VCB serviceable including making all electricalConnection and Testing ( IR Test, Continuity Test, Tripping test of earth fault and Over current of panel ) complete all as specified and directed by Engineer-in-Charge. |
| 241 | S&F in repairs 3 pole power contactor 1No+2NC as per sample of makeL & T, M/s Havells/Siemens/Standara / legrandall as specified and directed. |
| 242 | S&F, in replacement, MCCB, 415 volts, 04 pole, 400 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells |
| 243 | S&F, in replacement, MCCB, 415 volts, 04 pole, 250 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells |
| 244 | Taking down old unsv energy meter and Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including wiring and testing complete all as directed. |
| 245 | M&L for replacement of UNSV Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGI earth strip 32x6 mm by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe40 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 3 of SSR 2009 Part-I and connecting to LT Panel / DG Sets / Voltage Stabilizer /Building all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail