| Sl. No. | Item Description |
| 1 | Items: |
| 2 | Sec.2.0 ELECTRICAL WORKS SITC of mains with 2nos. of1.5sqmm Cu.PVC insulated FRLS flexible wire with ISIapproval for 650 V/1100 Vand 1 no 1.5 sqmmCu. PVCinsulated flexible wires with ISI approval for 650 V/1100 Vas earthwires tobe drawnin 25 mm diameter rigidPVC conduit ofmedium guagehaving ISI amd FIA approval with all necessary accessories. |
| 3 | SITC ofmains with 2nos. of2.5 sqmm Cu.PVC insulated FRLS flexible wire with ISIapproval for 650 V/1100 Vand 1 no 2.5 sqmmCu. PVCinsulated flexible wires with ISI approval for 650 V/1100 Vas earthwires tobe drawnin 25 mm diameter rigidPVC conduit ofmedium guagehaving ISI amd FIA approval with all necessary accessories. |
| 4 | HVAC- VRV SYSTEM Lifting & Shifting, Supply, Installation, Testing, Commissioning of floor mounted top / side discharge type AC Outdoor unit with Variable refrigerant flow system with required indoor units, refrigerant piping, refnet connection, individual controller, Necessary integrator for BMS with open protocol. The quote for the work should include necessary, lifting charges for mounting the Condensing units with rubber pads, first charge of 410A refrigerant and mounting of indoor units and other accessories. The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired, tested with all necessary controls. The outdoor unit shall be modular in design and should be allowed for side by side installation. Each modular inverter outdoor shall be having minimum 1 digltal scroll / inverter & 1 fixed scroll compressors , Heat exchanger, condenser fan etc., capable to operate at 3 Phase, 415 +/- 10 % Volts, 50hz power supply.The unit shall be provided with its own microprocessor control panel & electrical compartment with all necessary electrical and control components.Supply of Variable Refrigerant System with all accessories( Make : DAIKIN ) VRF Out-door Units( 60 H.P. ) |
| 5 | 36H.P. |
| 6 | 28H.P. |
| 7 | 16H.P. |
| 8 | 12H.P. |
| 9 | 08H.P. |
| 10 | Indoor Units Wall Mounted type VRF IDU 1.5 TR |
| 11 | Indoor Units Wall Mounted type VRF IDU 2.0 TR |
| 12 | Ceiling mounted 4way-Cassette Type VRF IDU 0.6 TR |
| 13 | Ceiling mounted 4way-Cassette Type VRF IDU 1.5 TR |
| 14 | Ceiling mounted 4way-Cassette Type VRF IDU 2.0 TR |
| 15 | Ceiling mounted 4way-Cassette Type VRF IDU 2.5 TR |
| 16 | Ceiling mounted 4way-Cassette Type VRF IDU 3.3 TR |
| 17 | Ceiling Suspended Ductable type high staic unit 4.0 TR |
| 18 | Ceiling Suspended Ductable type high staic unit 6.0 TR |
| 19 | Ceiling Suspended Ductable type high staic unit 8.0 TR |
| 20 | Remote Controllers Corded Remote Controllers for VRV System to modulationg Temprature and adjust fan speed of indoor unit.( Cooling Mode ) |
| 21 | Cordless Remote Controllers for VRV System to modulationg Temprature and adjust fan speed of indoor unit.( Cooling Mode ) |
| 22 | Central Remote Controller for above system comprising of all required Software. PC will be supplied by client. System should control & monitor all installed IDU / ODU. Following should be minimum controlling & monitoring features that system should cover; Start / Stop, Temperature settings, Mode control, Group formation, view alarms, Fault Diagnosis. |
| 23 | All refrigerant joints with insulation |
| 24 | Supply & laying of copper sheilded communication cable as per OEM size. |
| 25 | Supply, installation, Testing& Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 60 H.P. SYSTEM |
| 26 | Supply, installation, Testing& Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 36 H.P. SYSTEM |
| 27 | Supply, installation, Testing& Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 28 H.P. SYSTEM |
| 28 | Supply, installation, Testing& Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 16 H.P. SYSTEM |
| 29 | Supply, installation, Testing& Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 12 H.P. SYSTEM |
| 30 | Supply, installation, Testing& Commissioning of the following components for VRF system All refrigerant copper piping for Variable Refrigerant system having along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room, inside the vertical shaft & over the terrace shall be properly supported with hanger & exposed piping shall be properly covered with UV treated cloth & should be in closed tray if required with properly supported. The rates shall be included with all control & communication cables for communicating indoor unit to outdoor unit & Central Control Monitors laid in Clamped PVC pipe. The rate shall includes topping up refrigerant for complete system having total refrigerant piping length is for 08 H.P. SYSTEM |
| 31 | Mechanical Ventilation for ToiletSupply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specificationswith site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres.400 CFM Inline Axial Exhuast Fan for Toilet ( Floor Mounted ) |
| 32 | Mechanical Ventilation for ToiletSupply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specificationswith site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres.1000 CFM Inline Axial Exhuast Fan for Toilet ( Floor Mounted ) |
| 33 | Mechanical Ventilation for ToiletSupply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specificationswith site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres.1100 CFM Inline Axial Exhuast Fan for Dirty Room & Store Area (Floor Mounted ) |
| 34 | Mechanical Ventilation for ToiletSupply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specificationswith site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres.1100 CFM Inline Axial Fresh Air Fan for Dirty Room & Store Area ( Floor Mounted ) |
| 35 | Mechanical Ventilation for ToiletSupply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specificationswith site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres.1200 CFM Inline Axial Fresh Air Fan for Room & Passage Area (Floor Mounted ) |
| 36 | Mechanical Ventilation for ToiletSupply, Installation, Testing & Commissioning of ceiling suspended type Inline Exhaust Air Fan, as per specificationswith site fabricated GI required Gauge thick ducting and alluminium outlet grills & louveres.1800 CFM Inline Axial Fresh Air Fan for Room & Passage Area (Floor Mounted ) |
| 37 | M. S. structure for installing VRF / DX outdoor units duly epoxy coated / galvanized. |
| 38 | Fire Retardant Canvass connections |
| 39 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 32mm dia. |
| 40 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 25 mm dia. |
| 41 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 19 mm dia. |
| 42 | insulation work Supplying, fixing Duct Acoustic Insulation of open cell nitrile rubber sheet having density of 180-220 kg/m3 and recommanded thickness of 15 mm. It shall be fixed inside of the duct with the help of adhesive complete as per specifications and as required. 15mm |
| 43 | insulation work Supply & Installation of Under Deck Insulation with Class ‘O’ Nitrile Rubber with tough Aluminum foil facing & as per detail specifications - 25mm |
| 44 | Refrigerent charge of VRV system with Nitrogen pressure testing, vaccume test & all neccesary activity with eco-friendly refrigerent gas as per site conditions. |
| 45 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coatedinner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD)by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection tosuit the below capacity for each AHU rating by AC Vendor including transmission losses. ;Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration)4220 CFM 10.64 TR for PICU Ward |
| 46 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coatedinner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD)by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection tosuit the below capacity for each AHU rating by AC Vendor including transmission losses. ;Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat with water proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration)6245 CFM & 14.77 TR for NICU ward/Nurse station |
| 47 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ;Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Pricesto include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.4865 CFM & 17.8 TR |
| 48 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ;Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Pricesto include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.11935 CFM & 26.43 TR |
| 49 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coated inner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 50 mm static best efficiency Plug type Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with Air filtering media with 10 micron pre filter, Cooling coil section with Chilled water Coil complete with Copper tube 13 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ;Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan (only for VFD AHU Panels), inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Pricesto include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.2000 CFM & 4.0 TRfor Septic Dialysis at Second Floor |
| 50 | Treaed Fresh Air UnitDesign, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Mounted / Loft Mounted Treated Fresh Air Unit as specified below; Double Skinned with inner & powder coated outer skin of 0.8 mm, Density 40 Kg / m³ & 40 mm thick PUF Sandwitched insulated sectionalized construction Comprising of Fan section with best efficiency Plug Fan driven by suitable pole Eff - 1 Motor with VFD, IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with 20+10 micron pre filter, Cooling coil section complete with Copper tube 13 FPI AL finned 6 / 8 R deep DX cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, necessary vibration isolation arrangement by providing spring isolators;Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Panel supplied with matching rating for Fan motor, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, 5 RMT. Cables from AHU Panel to AHU, UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible Temp control thermostat with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) ;Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: Fan Exit velocity<=1800 FPM; Coil Face Velocity=500 FPM max; Filter Face=400 FPM max; dB<=60 at 1 M distance.Price shall be complete with alluminium anodized duct dampers along with fire retardant canvass connections for supply & Fresh air; AHU dimensions, configuration (single-tier / double-tier, top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Price shall includes AHU kit With electronic expansion valve, microprosser & necessary things to connect outdoor units of Variable Refrigerant System as specified below -6.0 TR / 1600 CFM @ 50 mm Static Capacity for 8 HP VRV ODU |
| 51 | 9.0 TR / 2500 CFM @ 50 mm Static Capacity for 12 HP VRV ODU |
| 52 | 12.0 TR / 3200 CFM @ 50 mm Static Capacity for 16 HP VRV ODU |
| 53 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor),Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / HotWater multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer\"s factory.400 CFM (HI WALL) |
| 54 | Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.3900 CFM / 40mm Static Pressure for Toilet |
| 55 | Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.500 CFM / 25 mm SP for Dirty Utility Exhaust |
| 56 | Sec Air Moving Equipment Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coatedinner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD)by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration)11350 CFM / 27.70 TR For PICU, NICU, Nurse Station & Passage at Ground Floor |
| 57 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coatedinner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD)by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration)4300 CFM / 6.12 TR With 1.50 kW Strip Heaters & Humidistate For CT Scan Room at Ground Floor |
| 58 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing & Commissioning of Floor Mounted Air Handling Units as specified below; Double Skinned powder coatedinner & outer skin of 0.6 mm & 43 mm thick, 40 kg / m3 PUF Sandwitched insulated aluminium sectionalized construction Comprising of Fan section with 65 mm static best efficiency Plug type Fan with variable frequency driven (VFD)by IP55 / 4P TEFC Fan Motor / fire resistant flexible fan outlet connection, The AHU shall comprise filter section with MERV 6 pre filter for return & fresh air, Fine filter section with MERV 12 filter, Cooling coil section with Chilled water Coil complete with Copper tube 12 FPI AL finned 4R deep chilled water cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, with Mixing box with Aluminium Aerofoil damper for supply, return & Fresh air, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter suitable for Respective AHUs, Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection,Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, Unit shall be supplied with Digital Thermostat withwater proof casing BMS compatible with interface modbus / bacnet protocol to connect the BMS panel ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: dB<=60 at 3 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above ; AHU dimensions, configuration (top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.(With 5 Micron Filteration)6850 CFM / 14.10 TR For Pre Op Room and Corridor at Second Floor |
| 59 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended ChilledWater Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with \"Y\" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer\"s factory.500 CFM |
| 60 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended ChilledWater Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with \"Y\" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer\"s factory.600 CFM |
| 61 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor),Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / HotWater multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with \"Y\" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer\"s factory.500 CFM |
| 62 | Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor),Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / HotWater multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with \"Y\" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer\"s factory.600 CFM |
| 63 | Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.3900 CFM / 40mm Static Pressure for Toilet |
| 64 | Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.3450 CFM / 40mm Static Pressure for Toilet |
| 65 | Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.2600 CFM / 40mm Static Pressure for Toilet |
| 66 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.200 mm dia.(32 mm thick insulation) |
| 67 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.150 mm dia.(32 mm thick insulation) |
| 68 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.125 mm dia.(32 mm thick insulation) |
| 69 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.80 mm dia.(32 mm thick insulation) |
| 70 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.65 mm dia.(32 mm thick insulation) |
| 71 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.50 mm dia.(32 mm thick insulation) |
| 72 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.40 mm dia.(32 mm thick insulation) |
| 73 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.32 mm dia.(19 mm thick insulation) |
| 74 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.25 mm dia.(19 mm thick insulation) |
| 75 | INSULATED CHILLED WATER PIPING Insulation (Closed Cell Nitrile Rubber GC bonded 2 layers of paint).Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation Closed Cell Nitrile Rubber GC bonded applied by suitable adhesive and, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.19 mm dia.(19 mm thick insulation) |
| 76 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified125mm dia. |
| 77 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified80mm dia. |
| 78 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified65mm dia. |
| 79 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified50mm dia. |
| 80 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.AUTO BALANCING VALVE complete with Flanges Nutbolts and Working parts80mm dia. |
| 81 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.65mm dia. |
| 82 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.50mm dia. |
| 83 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 84 | Providing & fixing in position the mercury in glass industrial type thermometres. |
| 85 | Supplying, fixing, testing and commissioning of wafer type Butterfly Valve as per IS 13095 with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of same size piping as per specification for:80mm dia. |
| 86 | Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matchingflanges(asperASME16.5),neoprenegasket,nutboltsandduly insulatedwithsamespecificationofsamesizepipingasperspecificationfor40 mm dia. |
| 87 | Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matchingflanges(asperASME16.5),neoprenegasket,nutboltsandduly insulatedwithsamespecificationofsamesizepipingasperspecificationfor32 mm dia. |
| 88 | Supplying, fixing, testing and commissioning of Manual balancing valve with pair of matchingflanges(asperASME16.5),neoprenegasket,nutboltsandduly insulatedwithsamespecificationofsamesizepipingasperspecificationfor25 mm dia. |
| 89 | INSULATED VALVESSupplying, fixing, testing and commissioning of CI Y Strainer with pair of matching flanges (as per ASME 16.5), neoprene gasket, nut bolts and duly insulated with same specification of samesize piping as per specification for:32mm dia. |
| 90 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts.25mm dia. |
| 91 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Supplying, fixing, testing and commissioning of Automatic Air Purge Valve at AHU chilled water outlet pipe duly insulated to the same specifications as the connected piping and adequately supported as per specifications.20mm dia. |
| 92 | SITC 100MM DIAL PG 0-10 KG/CM2Supply & Installation of dial type Pressure Gauge 100 mm size with SS needle valve and fittings 0-10 kg / cm2 range installed as per P & I Diagram. |
| 93 | SITC 100MM DIAL TG 0-50 DEG CSupply&InstallationofdialtypeTemperatureGauge100mmsizewithSSthermowell / coupling / glycerine or eq. conductive fulid and fittings 0 - 50 °C range installed as per P&I diagram. |
| 94 | Supplying,fixing, testing and commissioning of Brass ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping asper specification40mm dia. |
| 95 | Supplying,fixing, testing and commissioning of Brass ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping asper specification32mm dia. |
| 96 | Supplying,fixing, testing and commissioning of Brass ball valve with SS body and working parts, flanges, duly insulated with same specification of same size piping asper specification25 mm dia. |
| 97 | INSULATED VALVESSupplying, fixing, testing and commissioning of Automatic Air Purge Valve at AHU chilled water outlet pipe duly insulated to the same specifications as the connected piping and adequately supported as per specifications.20mm dia. |
| 98 | INSULATED VALVESSupply, Installation, Testing and Commissioning of following sizes 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shallprovide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.65mm dia. |
| 99 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Supply, Installation, Testing and Commissioning of following sizes 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shallprovide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.50mm dia. |
| 100 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Supply, Installation, Testing and Commissioning of following sizes 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shallprovide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.40mm dia. |
| 101 | INSULATED VALVESSupplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Supply, Installation, Testing and Commissioning of following sizes 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shallprovide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.25 mm dia. |
| 102 | BALL VALVE WITH STRAINER 25 mm Dia |
| 103 | Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet |
| 104 | Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.80 mm sheet |
| 105 | Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 1.00 mm sheet |
| 106 | Sec.5.0 Ducting, Grills, Diffuser and Insulation DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet |
| 107 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.80 mm sheet |
| 108 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. |
| 109 | Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU roomDamper |
| 110 | Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU roomActuator |
| 111 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
| 112 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. |
| 113 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 114 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. |
| 115 | Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications.200mm dia. |
| 116 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire Damper |
| 117 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator |
| 118 | Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. |
| 119 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. and above Bonded Treated Woven Glass Fibre for Outer covering of Insulation Material GC bonded applied by suitable adhesive. Density: 200 +/- 20 gsm Thickness: 0.18 mm / 7 mill, The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.19mm |
| 120 | 25 mm Dia. |
| 121 | 40 mm Dia. |
| 122 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. and above Bonded Treated Woven Glass Fibre for Outer covering of Insulation Material GC bonded applied by suitable adhesive. Density: 200 +/- 20 gsm Thickness: 0.18 mm / 7 mill, The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.25mm |
| 123 | CABLE TRAYSSupplying and fixing following sizes of GI Ladder type cable traysincluding couplers,fittings and other accessories as required, and duly suspended from the ceiling with suspenders/fixed on ceiling / walls on fastners etc as per specifications complete as required. 300 x 50 mm |
| 124 | 150 x 50 mm |
| 125 | Operation & Maintenance WorksSYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following :Comprehensivepreventivemaintenancecontract for theentirechilled watersystem& VRF System supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period.1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over.For Chiller Plant of 650 Tr & VRV Plant of 264 HpOnly Opearation Cost During DLP |
| 126 | 4.00 ELV SYSTEMSSec.1.0 Telephone and Data NetworkingProviding and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed.25 mm |
| 127 | Tag Blocks - Multipair Telephone Cable TerminationSupply & fixing of 100 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing. |
| 128 | Cabling - Multipair CablesSupplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections.AConductor Size 0.5 mm.(b)Armoured. (Jelly Filled)(3)Fifty Pairs. |
| 129 | Telephone / Data Networking CablingSupplying & erecting approved make LAN cable of following size in existing pipe as per direction.[C] CAT - 6 |
| 130 | Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge.(8) Modem Jack for Computer Open RJ-45.Cat. III. |
| 131 | Supplying, installation, testing and commissioning of UTP CAT6 24 ports capacity gigaspeed patch panel, all ports loaded with individual RJ-45 IOs. as per technical specification etc. as required. |
| 132 | Supplying, installation, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 7 feet as per technical specification etc. as required. |
| 133 | Supplying, installation, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 3 feet as per technical specification etc. as required. |
| 134 | Data Networking - Fiber Optic Cable and ComponentsSupplying, installation, testing and commissioning of outdoor 12 core armoured single mode fiber optic cable for outdoor connectivity where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available etc. as per technical specification etc. as required. |
| 135 | Supplying, installation, testing and commissioning of 19\" rack mounting type fiber shelf for assembly/termination of minimum 24 cores of singlemode ofc cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable etc. as required. Any blank adaptor positions must be suitably masked for restricting dust entry etc. as per technical specification etc. as required. |
| 136 | Supplying, installation, testing and commissioning of 19\" rack mounting type fiber shelf for assembly/termination of minimum 12 cores of singlemode ofc cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable etc. as required. Any blank adaptor positions must be suitably masked for restricting dust entry etc. as per technical specification etc. as required. |
| 137 | Supplying, Splicing , testing and commissioning of LC type single mode pre-terminated pigtail 1mtr as per tender specification etc. as per technical specification etc. as required. |
| 138 | Supplying, Installation, testing and commissioning of LC-LC single mode duplex fiber optic patch cord 1mtr. as per technical specification etc. as required. |
| 139 | Supplying, installation, testing and commissioning of Networking enclosure - Floor mounted, 19\" mounting frame, usable height 24U, 600mmW x 600mmD etc. as per technical specification etc. as required. |
| 140 | Supplying, installation, testing and commissioning of 42U Floor standing 19\" networking enclosure as per specification and complete with all accessories. (upto size - 800mmW x 1000mmD)as required. (along with horizontal cable manager & vertical cable manager, PDU with minimum 12 Nos. 16 Amp socket, as per technical specification etc. as required. |
| 141 | Active Components- Data & Voice NetworkingTYPE-1Supplying, installtion, testing and commissioning of Layer 3 features switch: 16 # port 10G SFP+ With redudant power supply & standard mouting hardware & accessories. Core Switch for Server room, as per technical specification etc. as required. |
| 142 | TYPE-2Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE+ as per 802.3at, minimum 2 SFP+ ports. as per technical specification etc. as required. |
| 143 | TYPE-3Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 24 # 10/100/1000Tx ports, minimum 2 SFP+ ports as per technical specification etc. as required. |
| 144 | TYPE-4Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 48 # 10/100/1000Tx ports, all 48 ports shall be capable of providing PoE+ as per 802.3at, minimum 2 SFP+ ports. as per technical specification etc. as required. |
| 145 | TYPE-5Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 48 # 10/100/1000Tx ports, minimum 2 SFP+ ports as per technical specification etc. as required. |
| 146 | Supplying, installation, testing and commissioning of10G SFP+Single mode transceiver, 1310nm, 2Km, LC connector, inclusive of any hardware such as modules for populating SM-LC transceivers as per technical specification etc. as required. |
| 147 | Supply, Installation, Testing and Commissioning of Wireless indoor Access Point supporting Dual band with 802.11a/n/ac (5 GHz) and 802.11g/n (2.4GHz) concurrent operation with MIMO support 3x3, 3 spatial streams, One 10/100/1000 BASE-TX auto-sensing (RJ45) PoE port, as per technical specification etc. as required. |
| 148 | Supply, Installation, Testing and Commissioning of Hardware based Wireless Access Controller, License with Minimum 50 Access point and support up to 128 access point, as per tender specification etc. as required. |
| 149 | Supply, Installation, Testing and Commissioning of industry-standard intel based server, The minimum specifications required are as follows : - Processor : Quad Core Intel Xeon, Dual Core, i7 or above- Memory : Minimum 16 GB- Hard Disk : SATA SSD with 4 TB- Oerating System : Linux SUSE- Vendors to provide Duplicate Servers in HOT STANDBY MODEas per tender specification. |
| 150 | Supply, Installation, Testing and Commissioning of User Call Control Application for all users/extensions, Voice Messaging Application inclusive of voice mail licences for users and inclusive of computer application and operating system, Emergency response services with voice messaging, inclusive of licences as per technical Specification. |
| 151 | Supply, Installation, Testing and Commissioning of IP Phone with display as per tender specification etc. as required. |
| 152 | “Supplying & erecting push button type telephone instrument having speaker phone Caller ID & hands free dialing system“(a) Single line BPL/SONY/BEETEL or equivalent make” |
| 153 | Sec.2.0 Video Survelance/CCTV SystemSupply, Installation, Testing & Commissioning of Vandal reistant True Day Night Veri-Focal Dome Camera 2MP,Full HD, 1/2.8 type CMOS image sensor, 2.8 -12mm motorized focus lens, Aperture Ratio F1.8, Wide Dynamic Range - 120dB, H.265 / H.264 & MJPEG dual-stream encoding,25/30fps@1080P (1920 ×1080),IR LEDs length minimum 20 m, Motion Detection , Tampering ,Defocus detection ,Hallway view ,Micro SD Card - 128GB capacity, IP66 rated, IK 10 and as per technical Specification ,The Camera must be UL Listed. as per technical specification etc. as required. |
| 154 | Supply, Installation, Testing & Commissioning of True Day Night BulletCamera 2MP,Full HD, 1/2.8 type CMOS image sensor, Autoiris Varifocal lens 2.8 - 12mm motorized focus lens , Aperture Ratio F1.4, Wide Dynamic Range - 120dB, H.265 / H.264 & MJPEG dual-stream encoding,25/30fps@1080P (1920 ×1080),IR LEDs length minimum 30 m, Motion Detection , Tampering ,Defocus detection ,Hallway View, Micro SD Card - 128GB capacity, IP66 rated, IK 10 as per technical specification The Camera must be UL Listed, as per technical specification etc. as required. |
| 155 | Supply, Installation, Testing & Commissioning ofVandal Resistant PTZ Network Cameras,IR with 350 Mtrs Viewing Distance 30 X Optical Zoom,camera with 1/1.9\" sensor, 2MP, Full HD(1080p) @60fps WDR off or @15fps WDR on, H.265/H.264/MJPEG, 120dB WDR, Auto Tracking, true D/N,,Edge Analytics - Auto Tracking, Virtual Perimeter, Entry/Exit Detection, Tampering,SD/SDHC/SDXC memory slot, 24VAC, IP66, IK10 .including all mounting accessories.The Camera must be UL Listed, as per technical specification etc. as required. |
| 156 | Supplying, installtion, testing and commissioning of Server(s) required for NSM & NVMMS - Industry standard Intel based platform, rack mounted, redundancy architecture for critical hardware components, licensed Microsoft Server operating system and requisite user licenses, licensed application suites, 2 x Quad Core Intel® Xeon latest processors or better, 8 GB of RAM, 2 x 1.2 TB of SAS HDDs, minimum 2 additional hard disk drive bays for expansion, 1,280 x 1,024Display/ video resolution, 2 X 10/100/1000 ethernet network interface card, Video memory 2GB above, RAID support built-in, DirectX 8.1 above and pre-installed DVD-R/W Drive and Appropriate Licensed Operating Systems as per NSM & NVMMS Requirement. as per technical specification etc. as required. |
| 157 | Supplying, installation, testing and commissioning ofNetwork storage required with a capacity to store the content for 165 cameras for 24Hrs x 30 days at 25fps and 1080p (Minimum 110TB from day 1). It should be scalable (should have sufficient expansion bays for HDDs) for at least additional 50 cameras. Vendor shall submit bandwidth and storage calculator for the proposed camera models as per technical specification etc. as required. |
| 158 | Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
| 159 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. as per technical specification etc. as required. |
| 160 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. as per technical specification etc. as required. |
| 161 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. as per technical specification etc. as required. |
| 162 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. as per technical specification etc. as required. |
| 163 | Supplying, installation, testing & commissioning of addressable fire control / Monitor module complete as required. as per technical specification etc. as required. |
| 164 | Supplying, installation, testing & commissioning of addressable phone control module complete as required. as per technical specification etc. as required. |
| 165 | Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. as per technical specification etc. as required. |
| 166 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. as per technical specification etc. as required. |
| 167 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. as per technical specification etc. as required. |
| 168 | Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. as per technical specification etc. as required. |
| 169 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 170 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 171 | Supply, Installation, Testing and Commissioning of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection as per technical specification etc. as required. |
| 172 | Supply, Installation, Testing and Commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5Was per technical specification etc. as required. |
| 173 | Supply, Installation, Testing and Commissioning of Volume Controller, Built-in 24V DC forced relay, Selectable power : 120W,Frequency response of 100Hz- 20 KHz, 100V input voltage with required back box, as per technical specification etc. as required. |
| 174 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Single pair, 2-core, 1.5 sqmm, For PA System |
| 175 | Sec.4.0 Access Control System“Providing & erecting approved make Fingerprint and card based premium Door controller with LCD and Keypad having following features.”(A) Optical Fingerprint and card based Reader (Card personality Modulenot included) “(B) Dot – Matrix LCD and Touch sense Keypad “(C) Built-in interfaces like door lock, door sense exit Reader, Exit switch, Ethernet RS485, Aux Input & aux output port “(D) 5000 Events, access Control, Time Attendance, Tamper Detection “(E) 4 LEDS and Buzzer” |
| 176 | “Providing & erecting approved make Card Reader having following features. “[A] Wiegand/ RS232 Interface “(B) Power supply from COSEC Door controller or through Separate Adaptor “(C) Compatible with any COSEC Door controllers “(D) 4 LEDs (Status, Alarm, Allowed and Denied) and Buzzer “(E) Tamper Detection” |
| 177 | “Providing & erecting approved make Card Personality Module (CPM) having following features “(A) EM proximity Card Reader Module [Low Frequency] “(B) Compatible with any COSEC Door Controllers and COSEC Reader CA “(C) Supports EM Proximity Card” |
| 178 | “Providing & erecting approved make Panel Controller for Multiple Door Controller having following feature “(A) Controls up to 16 Door Contioiiers “(B) Ethernet RS485, USB, Aux Input and Aux output port “(C) 10000 Users Capacity and 100000 Events Storage “(D) 32-bit processor, 32 MB RAM and 32 MB Flash “(E) Compact and Elegant Design” |
| 179 | Sec.5.0 Cable TV Distribution SystemProviding following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge.(4)TV Co-axial Socket outlet.Cat. III. |
| 180 | Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (b) RG – 6. |
| 181 | Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (e) RG – 11. |
| 182 | Sec.2.0 ELECTRICAL WORKS SITC of mains with 2nos. of1.5sqmm Cu.PVC insulated FRLS flexible wire with ISIapproval for 650 V/1100 Vand 1 no 1.5 sqmmCu. PVCinsulated flexible wires with ISI approval for 650 V/1100 Vas earthwires tobe drawnin 25 mm diameter rigidPVC conduit ofmedium guagehaving ISI amd FIA approval with all necessary accessories. |
| 183 | SITC ofmains with 2nos. of2.5 sqmm Cu.PVC insulated FRLS flexible wire with ISIapproval for 650 V/1100 Vand 1 no 2.5 sqmmCu. PVCinsulated flexible wires with ISI approval for 650 V/1100 Vas earthwires tobe drawnin 25 mm diameter rigidPVC conduit ofmedium guagehaving ISI amd FIA approval with all necessary accessories. |
| 184 | SITC ofmains with2nos.of4sqmm Cu.PVC insulated FRLS flexible wire with ISIapproval for 650 V/1100 Vand 1 no 4.0 sqmmCu. PVCinsulated flexible wires with ISI approval for 650 V/1100 Vas earthwires tobe drawnin 25 mm diameter rigidPVC conduit ofmedium guagehaving ISI amd FIA approval with all necessary accessories. |
| 185 | XLPE armoured cable of 1100 V grade of copper conductor of following size 3C X 6 SQMM CU ARMEREDCABLE |
| 186 | XLPE armoured cable of 1100 V grade of copper conductor of following size 4C X 16 SQMM CU ARMERED CABLE |
| 187 | Copper cable of 1100V grade of copper conductor of following size 4C x 70 SQM CU flexibal Cable. |
| 188 | Supply, of750mm*16mm j bolt cable entry pipe 8 swg ciol erathing rcc foundation 1000*600*600mmConcrete foundationwith base plate.Excavation for erection of poles as per drawing complete in all respect Pole |
| 189 | Supplying,unloadingatsite,shiftingtosite,assembling,leveling,grouting,erecting,Testing,& Commissioningcompartmentalizedtype Panelswithpowdercoated fabricatedfromCRCAsheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detailtednerspecifications.The successfultendererwillhave toprepare generalarrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. MGPS PANEL-13 ( SLD ). As per Single line diagram. |
| 190 | SITC of 100 A FP MCCB with sheet steel metal enclouser with ELR |
| 191 | SITC of 80 A FP MCCB with sheet steel metal enclouser with ELR |
| 192 | Providing of 32 A x 250 V Plug & socket with interlocked switched socket, DP MCB and surface mounting box FOR laundry. |
| 193 | Providing of 32 A x 440 V Plug & socket with interlocked switched socket, FP MCB and surface mounting box FOR laundry. |
| 194 | Providing of 63 A x 440 V Plug & socket with interlocked switched socket, FP MCB and surface mounting box FOR laundry. |
| 195 | Supply, installation, testing and commissioningof hand held portable operator terminals (POT) minimum 7 inch. TFT display with capacitive touch screen type, shall be able to view graphs , alarms , parameters etc. POT shall have integrated web server and a BACnet/ IP web interface to connect a HTML5 browser to a device on the network. POT With all required connectors etcas per technical specification etc. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail