|
| 1 | Supplying and pasting tarfelt APPsheets having thickness greater than 1 mm of reputed manufacture one layer over A.C sheet expansion joints, ridges etc after cleaning the surface and applying roofing compound etc complete. (The rate shall include cost of tarfelt ,roofing compound labour charges scaffolding etc complete. The work is to be carried out at roof of godown at a height up to 12Mtrs from ground level after observing all safety norms) |
| 2 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 3 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 4 | Cleaning masonry drains of width 25 cms to 60 cms and depth up to 60 cms, including removal of silt and rubbish, cutting and removing grass and other vegetation from the sides of drains and disposal of rubbish within a distance of 150 mts.etc.complete. |
| 5 | Cleaning masonry drains of width 60cm to80cm including removal of silt and rubbish with in a distance of 150 mrts and removing the grass and vegetation from the side of drain for a width of 1mtr as directed by the Engineer-in-charge |
| 6 | Taking out RCC cover slabs (50 mm thick) of drain care fully without any damage and keeping the same in position after cleaning the drain etc complete |
| 7 | Reparing/Servicing rolling shutters such as removal of top covers tightening/ loosening the springs adjusting the dislocation of parts if any and applying greese to the springs side guides ( 0.40 kg greese/ shutter) after cleaning and refixing the cover in position etc as directed by engineer in charge. |
| 8 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on speciallydesigned pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top coverItem No.10.6.1 of DSR 2023 |
| 9 | Cleaning of well/sump including removing the cover and refixing, dewatering, removing silt , clay etc from the bottom of the well, cleaning the walls of the well, removal of vegetation along sides, disposal of all debris etc. complete as directed by the Engineer-in-charge (The work is carried out after following all the safety norms) (the rate shall include all labour, hire charges of the pump equipment, scaffolding etc). |
| 10 | Cleaning of main over head tank and other P.V.C.tanks installed over the roofof depot/ staff quarters and other buildings etc. including removal of silt/rubbish from tank, disinfecting with bleaching powder @ 0.5 gm per litre capacity of tank, disposal of silt/debris outside the FCI boundary etc.. all complete as per direction of Engineer-in-charge. (The work has to be carried out at roof top level after following all the safety norms)(Analysed rate) |
| 11 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead : With cement mortar 1:4 (1 cement : 4 fine sand) ( Item No 14.1.1of DSR 2023) |
| 12 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar(15.9.2) |
| 13 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) with available stone at site.(item similar to item no:7.1 of 2023) |
| 14 | Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) Flush/ Ruled pointing (13.33.1) |
| 15 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.(in cement mortar) (item no: 15.7.4of DSR 2023) |
| 16 | Providing and laying factory made pre cast solid blocks of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth level with thickness 15cm in CM 1:6 ( 1 cement : 6 coarse sand) etc complete. |
| 17 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (15.56) |
| 18 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)Item no.13.16 of DSR 2023 |
| 19 | 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand) |
| 20 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium(minimum thickness of powder coating 50 micron)(Item no: 21.1.1.2 of DSR 2023) |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately. Powder coated aluminium (minimum thickness of powder coating 50 micron (Item No.21.1.2.2 of DSR 2023) |
| 22 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (Item no:21.3.1 of DSR 2023) |
| 23 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) Item 14.5.1 of DSR 2023 |
| 24 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture withmatching wood beading.Item No.9.7.8 of DSR 2023 |
| 25 | Providing and laying waterproofing treatment to concrete roof surfaces using acrylic based waterproofing compounds such as tapecrete or any approved make including preparation of surface by cleaning all dust/ deposits, crack filling, providing fiber glass cloth and applying the mixture in the ratio of 100 kg. cement : 50 kg of TAPECRETE. (The mix has to be prepared without any air bubbles.), two or more coats, curing the coating, complete as directed by the Engineer-in-charge. (Analysed item) |
| 26 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (item 13.88 of DSR 2023) |
| 27 | Applying priming coats with primer of approved brand and manufacture, having low VOC(Volatile Organic Compound) content.:With water thinnable cement primer on wall surface having VOC content less than 50grams/litre (Item no.13.85.3 DSR 2023) |
| 28 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats(13.82.2 of DSR 2023) |
| 29 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.(item 15.19 of DSR 2023) |
| 30 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksItem no.10.25.2 of DSR 2023 |
| 31 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes |
| 32 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge.The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Hqrs Approved Rate) |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.Item no.13.62.1 of DSR 2023 |
| 34 | Deduct cost of salvagable materials received from the work of dismantling work on as is where is condition includingremoving from the site - GI gate (market rate) |
| 35 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI metal ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.50 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm ( both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (item 12.52.1 of DSR 2023) |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm(item 11.41.2 of DSR 2023) |
| 37 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)(item no: 4.1.3 of DSR 2023) |
| 38 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth.(Item No.4.17 of DSR 2023) |
| 39 | Providing and laying 60 mm thick factory made Cement Concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with sand etc.. all complete as per direction of Engineer-in-Charge. (Item 16.68 of DSR 2023) |
| 40 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm (item 15.23.1 of DSR 2023) |
| 41 | Cleaning the chocked upSW/PVC sanitary line with drain cleaning rods and cleaningappliances and make the line through for free flow of sanitary discharge. |
| 42 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms(item 18.64 of DSR 2023) |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm nominal dia Pipes( Item no. 18.9.6 of DSR 2023) |
| 44 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge.(Item No.14.82 of DSR 2023) |
| 45 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \"S\" or \"P\" trap including dismantling of old WC seat and \"S\" or \"P\" trap at site complete with all operationsincluding all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm(14.80.2) |
| 46 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap(Item No.17.7.2,DSR 2023) |
| 47 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.DSR 2023 Item No.16.19 |
| 48 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, and provided with horizontal lines and two diagonals interwoven with horizontal wires of barbed wire weighing 9.38 kg per 100 m(minimum), between the two posts fitted and fixed with G.I. Staples etc.. complete (Cost of posts, struts, concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire(Analysed as per item no.16.18.1 of DSR 2023) |
| 49 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (15.60) |
| 50 | Engaging hydraulic excavator and labour for collection of debris/waste, loading the waste in vehicle for disposal, clean and level the site including fuel and driver charge,etc complete as per direction of engineer in charge (excluding the rate for disposal).(Observed data) |
| 51 | Providing 250mm PVC rain water eave gutter withworking pressure 4 kg/sq cm as per standard design and manufacture with bolts, nut washers etc. including providing necessary spouts/ shoes etc. (Cost of iron clamps, bracketsand other fittings will be paid separately) |
| 52 | Providing flatiron brackets 50x6mm size with necessary bolts, nuts ,washers and welding etc.for fixing PVC eave gutter with purlins (Observed data) |
| 53 | Providing 250x160 mm PVC running outlet of working pressure 4 kgf/sqm as per standard design and manufacturers specification(observed data) |
| 54 | Providing160 mm PVC Elbowas per manufacturers specification to suit the drop over theeave gutter etc.complete,[Rate as per observed data] |
| 55 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, |
| 56 | Providing and fixing soil, waste and vent pipes :50 mm PVC pipe(item similar to17.35.1.1 of DSR 2023) |