| 1 | Dismantling of wall andceiling boards(fibre, pulp, insulationetc.) or insulation boards/ slabs/ blankets, any thickness including cover filletscomplete all as specified and directed by Engr in Charge. |
| 2 | Dismantling timber scantlings 40 sq.cm and over in section, in any positions as in framed workcomplete all as specified and directed by Engr in Charge. |
| 3 | M&L for clean sawn second class hard complete all as specified and directed by Engr in Charge. |
| 4 | M&L for 2nd class hard wood plain fillets,square,rectangular,or triangular in section clean sawn exc 13 sqcm and n exc 25 sqcm secured with nails or brads complete all as specified and directed by Engr in Charge. |
| 5 | S&F Anodised aluminium snap grid framed work for false ceiling and incl hangers 6mm dia G.I (upto 1200mm long) adjusting level fixed to roof slabs/purlin/rafter with the help of cleats made out of G.I flat 40x3mm size 60mm long and expansion holdfastener 12.5mm dia 40mm long complete all as specified and directed by Engr in Charge. |
| 6 | M&L for false ceiling with gypsum board, perforated type, ,factory madematt finish surface/pre painted surface,600 x 600 mm in size and 12 to 15 mm thick on exisitingaluminium snap grids 605 X 605 mm as in ceiling complete all as specified and directed by Engr in Charge. |
| 7 | M&L 6mm thick ply wood, grade BWR, type BB fixed with screws to timber frame work in partitions/shutters, ceiling etc complete all as specified and directed by Engr in Charge. |
| 8 | M&L vennered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces, fixed with screws to timber frame work etc complete all as specified and directed by Engr in Charge. |
| 9 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr in Charge.. |
| 10 | M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm gradedstone aggregate) in plinth protections, finished even and smooth w/o using extra cement complete all as specified and directed by Engr in Charge. |
| 11 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed by Engr in Charge. |
| 12 | Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed by Engr in Charge. |
| 13 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr in Charge. |
| 14 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (hereever required) and fitting the same with necessary stainless steel nuts and bolts necessary accessories & stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size on the top of floor r the side of waist slab with suitable arrangement complete all as specified and directed by Engr in Charge. |
| 15 | Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 16 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr in Charge. |
| 17 | M & L for Reinforced Cement Concrete M-25 (using 20 mm graded granite stone aggregate) in Beams, cantilevers, lintels over 1.5 M span complete all as specified and directed by Engr in Charge. |
| 18 | M & Lfor 10mm dia and over TMT bars cut to length bentto shape as required including binding withmild steel annelid wire not less than 0.90mm dia complete all as specified and directed by Engr in Charge. |
| 19 | M & Lfor 5mm dia and over up to 10 mm dia TMT bars cut to length bentto shape as required including binding withmild steel annelid wire not less than 0.90mm dia complete all as specified and directed by Engr in Charge. |
| 20 | Use & waste Form work to sides and soffits of floor or roof beams, lintiles cantilever etc for rough finished surface complete all as specified and directed by Engr in Charge. |
| 21 | M&L for taking down plastering in cement mortar complete all as specified and directed by Engr in Charge. |
| 22 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cementall as specified and as directed by Engineer-In-Charge. |
| 23 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even andsmooth without using extra cement complete all as specified and directed by Engr in Charge. |
| 24 | M & L for complete removal ofexisting treatment of old plastered surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and directed by Engr in Charge. |
| 25 | M & L for preparation of newplastered surface of wall and applying two coat of oil emulsion distemper over a coat of putty of 1mm thickness complete all as specified and directed complete all as specified and directed by Engr in Charge. |
| 26 | M & L for complete removal of existing treatment on old plastered surface of wall and applying two coat of oil emulsion distemper over a coat of putty of 1mm thickness complete all as specified and directed complete all as specified and directed by Engr in Charge. |
| 27 | M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed by Engr in Charge. |
| 28 | M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed by Engr in Charge. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr in Charge. |
| 30 | M&Lscreed bed or bedding layer of morter 15 mm thick cement plaster 1:6 for laying floor finished to receive floor tiles/granite complete all as specified and directed by Engr in Charge. |
| 31 | M&Lscreed bed or bedding layer of morter 10 mm thick cement plaster 1:4 for laying floor finished to receive wall tiles/granite in dado/skirting complete all as specified and directed by Engr in Charge. |
| 32 | M & L for Virified Ceramic tilesLight shed 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr in Charge. |
| 33 | M & L for Virified Ceramic tilesLight shed 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, on walls in dado/skirtting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr in Charge. |
| 34 | M&L joint free Non-Skid ceramic coloured tiles 7 to 8mm thick grade BII matt superior finish first quality area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bedin cement mortar 1:4 complete all as specified and directed by Engr in Charge.Make-Somany/Orient |
| 35 | M&L vitrified tiles coloured tiles 8 to 10 mm thick grade BII matt superior finish first quality area of each tile exceeding 0.36 sqm but not exceeding 0.72 sqm in dado/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick screed bedin cement mortar 1:4 complete all as specified and directed by Engr in Charge.Make-Somany/Orient |
| 36 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed by Engr in Charge. |
| 37 | Prepainted galvanume aluminium zine coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws complete all as specified and directed by Engr in Charge. |
| 38 | Prepainted galvanume aluminium zine coating GI based plain steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws |
| 39 | S&Fplates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentincluding welding etc all as spfd and directed by EIC.Fe-410-W(gde-E-250) quality B. |
| 40 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engr-in-charge. |
| 41 | S&F pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by Engr in Charge. |
| 42 | M&L Plain Cement Concrete1:3:6 type C1 filling of pressed steel frame and hold fast block etc. complete all as specified and directed by Engr in Charge. |
| 43 | S & F 35 mm thick factory made second class hard wood, kiln seasoned and chemically pressure treated plain framed, panelled shutter (Two panel) with lock rail and panel of 9 mm BWP Commercial ply or 12 mm veneered particle board with commercial face veneers on both faces or 10 mm bison panel complete all as specified and directed by Engr in Charge. |
| 44 | Supply and fixing(factory Made)2nd class hard wood35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge.(Without sash bars) edges of framing plain chamfered or rounded fittedwith cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) supplied and fitted to chowkatscomplete all as specified and directed by Engr in Charge. |
| 45 | Supply & fixing steel windows/ventilator with side hung shutters including projection type hinges with steel handle, tower bolt and steel peg stay, complete with glazing bars dovetailed or welded complete all as specified and directed by Engr in Charge. |
| 46 | S&F in repair19 mm dia curtain rods fancy type, mild steel chromium plated with fixing brackets, stops, rollers all as specified and as directed by Engr-in-charge. |
| 47 | S&F floordoor stopper 140 mm of aluminium alloy body and tongue anodised with hard drawn steel springcomplete all as directed by Engineer-in-charge. |
| 48 | Supply& fixing MS barrel tower bolt of 100mm long stove enamelled black with bright bolt complete all as specified and directed by Engr-in-charge. |
| 49 | Supply & fixing 300 mm longmild steel sliding door bolts plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolts plate and two on couple plate and fixed complete all as specified and directed by Engr-in-charge. |
| 50 | Supply& fixing MS pressed handle oval type stove enamelled black of 125mm long fixed with screw to shutter complete all as specified and directed by Engr-in-charge. |
| 51 | Supply & fixing in repairs 300 mm,Mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed by Engr in Charge. |
| 52 | Supply & fixing for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm & fixed with tinned tacks, or galvanised wire staples. & directed by Engr-in-charge. |
| 53 | S&F plain sheet glass of 3 mm thick in Squares not exceeding 0.50 Sqm in each pane with oil putty and clips complete all as directed by Engineer-in-Charge. |
| 54 | S&Fin repair Vitreous China, pedestal patternwhiteincluding trap set with concrete includingSeat and cover,10ltrs low level fluslhing cistern with flush pipe complete all as specified and directed by engr-in-charge. |
| 55 | M & L Granite (of any type) 18 to 20 mm thik work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr in Charge. |
| 56 | S & F in repair for Wash Hand basins, Vitreous China, white, flat back, size 550x440mm, including cutting for and pinning in ends of brackets or erecting stand, angle bracket (but exclusive of fixing of supply, waste pipe, taps) complete all as specified and directed by Engr in Charge. |
| 57 | S&Fin repair bib taps 15mm diafancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed by Engr In Charge. |
| 58 | S&F in repair Angle stop valve of PTMT any colour pressure screwed for iron pipe and fixed (15mm minimum weight 90 Gms) 15mm dia fixed to iron pipe complete all as specified and directed by Engr in Charge. |
| 59 | Supply & fixing in repair 15mm pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down , high pressure, with or without lettered \"Hot\" or Cold\" with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm complete all as specified and directed by Engr In Charge. |
| 60 | S&F in repair for waste coupling of PTMT for 32 mm bore dia of discharge pipe (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and directed by Engr in Charge. |
| 61 | S&Fin repairPVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engr in Charge. |
| 62 | S&F in repair cast iron floor trap 75mm out let dia with grating including jointing to waste pipefixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engr in Charge. |
| 63 | M & L for Gully traps salt glazed stoneware (SGSW)square or round mouthed type \"P\" of size 180x100mmfor drain pipes complete all as specified and directed by Engr in Charge. |
| 64 | S & F 75 mm dia bore PVC (SWR) pipes single socketed , in any length with rubber ring joints , laid in tenches or in floors complete all as specified and directed by Engr in Charge. |
| 65 | S & F 110 mm dia bore PVC (SWR) pipes single socketed , in any length with rubber ring joints , laid in tenches or in floors complete all as specified and directed by Engr in Charge. |
| 66 | S & F75 mm diabore PVC (SWR) bends any radius complete all as specified and directed by Engr in Charge. |
| 67 | S & F110 mm diabore PVC (SWR) bends any radius complete all as specified and directed by Engr in Charge. |
| 68 | S & F110 mm diabore PVC (SWR) junction single \"T\" equal or unequalcomplete all as specified and directed by Engr in Charge. |
| 69 | S & F PVC (SWR) 110 mm borevent cowl complete all as specified and directed by Engr in Charge. |
| 70 | S&F soap dish vitreous china white, approximate size 160x160x90mm embedded in the wall complete all as specified and directed by Engr in Charge. |
| 71 | S& F 4.5 mm thick bevelled edge mirror or selected quality glass (Make saint Gobin/Modi) and fixed with studs to wall complete all as specified and directed by Engr in Charge. |
| 72 | S&F in repair towel rail 600mm having cat part No ACN-CHR-11115M of Jaguar/equivelent complete all as specified and directed by Engr in Charge. |
| 73 | S&F in repair wall mixture 3 in 1 system having cat part No FLR-5281 (Floretine) of Jaguar/equivelent complete all as specified and directed by Engr in Charge. |
| 74 | S&F in repair overhead shower single flow, 100mm dia (ABS CP) with shower arm of length 100mm having cat part No OHS-CHR-1989 of Jaguar /equivelent complete all as specified and directed by Engr in Charge. |
| 75 | Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or offering credit as per schedule of credit complete all as specified and directed by Engr in Charge. |
| 76 | All as per item above 75 herein before but20mm bore complete all as specified and directed by Engr in Charge. |
| 77 | S&F 3-layer PP-R Polypropylene random copolymer) of outer dia 20 mm ourter diaconcealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engr in Charge. |
| 78 | S&F 3-layer PP-R Polypropylene random copolymer) of outer dia 25 mm outer dia concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engr in Charge. |
| 79 | M & L in repair 12mm thick particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work in flat or sloping complete all as specified and directed by Engr in Charge. |
| 80 | M&Lin repairs 18/19mm thick particle board, medium density, flat pressed single line layer type or three layer type with BWR type adhesive fixed with screws to timber frame including dismantling existing board complete all as specified and directed by Engr in Charge.Make-Century |
| 81 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent holder, sketch fitting & regulator etc. includingmaking good to the disturbed surfaces of wall, roofand floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 82 | Taking down unserviceable submain wiring and service cablealongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site complete all as specified and directed by Engr in Charge. |
| 83 | Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge |
| 84 | M&L for point wiring using approved colour coding as per IS with using approved colour coding as per IS 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulatedstranded copper conductor cable for continuous earthing in & incl PVC Casing and capingwith accessories having ISI mark fixed on wall surfaces / ceilingincludingfixing switches sockets etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 85 | All as per Srl item No 84 here-in-before but controlled with one 3 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 86 | All as per Srl item No 84 here-in-before but controlled with one 3 pin socket outlet 5 Amp onthe independent board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 87 | All as per Srl item No 84 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board withcable 2.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge.Note: Modular Boxes, Modular plate with covered modular Switches ,Socket etc will be measured & paid seperately. for item ser no 1 to 7 |
| 88 | Supply and fixModular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete all as specified and directed by Engr in Charge. |
| 89 | Supply and fixSocket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI markedcomplete all as specified and directed by Engr in Charge. |
| 90 | Supply and fixSocket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI markedcomplete all as specified and directed by Engr in Charge. |
| 91 | Supply and fixModular switch 1 way 16A, 1 module, multipurpose flush type, ISI markedcomplete all as specified and directed by Engr in Charge. |
| 92 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 2 module ISI markedcomplete all as specified and directed by Engr in Charge. |
| 93 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 3 module ISI marked complete all as specified and directed by Engr in Charge. |
| 94 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 4 module ISI markedcomplete all as specified and directed by Engr in Charge. |
| 95 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 6 module ISI markedcomplete all as specified and directed by Engr in Charge. |
| 96 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 8 module ISI markedcomplete all as specified and directed by Engr in Charge. |
| 97 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 1/2 moduleISI markedcomplete all as specified and directed by Engr in Charge. |
| 98 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 3 moduleISI markedcomplete all as specified and directed by Engr in Charge. |
| 99 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 4 moduleISI markedcomplete all as specified and directed by Engr in Charge. |
| 100 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 6 moduleISI markedcomplete all as specified and directed by Engr in Charge. |
| 101 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 8 moduleISI marked complete all as specified and directed by Engr in Charge. |
| 102 | Material and labour for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. complete all as specified and directed by Engr in Charge. Make : Anchor/leader/havells |
| 103 | Supply andfixing in replacment surface & wall mounted LED 20W (Warm white) tube light fitting batten 4 feet, mirrorlite slim type with extruded aluminium housing alongwith 20W LED lamp PC body with all accessories all as specified and directed by Engr-in-Charge. Make: Crompton Havells/Wipro/ Bajaj(Warm White) |
| 104 | Supply andfixing in replacment surface & wall mounted LED 10W tube light fitting batten 2 feet, mirrorlite slim type with extruded aluminium housing alongwith 10W LED lamp PC body with all accessories all as specified and directed by Engg-in-Charge. Make: Crompton Havells/Wipro/ Bajaj(Warm White) |
| 105 | Supply and fixing round ,Recessed mount LED 15 watts downlight with in built LED driver, injection moulded housing and made of high translucent frosted optically efficent for anti-glare and smooth light distribution, complete all as specified and directed by Engr in Charge. Make-Crompton Cat No. LDRDLJ7-WW or equivalent in havells Cat No. LHEEBPP5IL1W008 or wipro Cat No.D520727 |
| 106 | M&L Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge. |
| 107 | S & F LED light fitting 1X10W bulkhead fitting luminaires including LED light driverholder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge. |
| 108 | S&Fexhaust Fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V,50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as per specified and directed by Engineer-in-Charge. |
| 109 | Supply and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cable flat or circular of size 16 Samm complete all as per specified and directed by Engineer-in-Charge. |
| 110 | Supply and fixing ofsheet metal enclosure double door DBs Singlepole and neutral for 8 way 240 volt complete all as specified and direct by Engineer-in-Charge . |
| 111 | Supply and fixing in MCB SPN 63 amps 240 V complete all as specified and direct by Engineer-in-Charge . |
| 112 | Supply and fixingMCB SPN 16-25 amps 230V complete all as specified and direct by Engineer-in-Charge . |
| 113 | S&F MCB SP 6 Amp to 32 Amp, 10 KA. all as specified and directed by Engineer-in-Charge. Make Havells or equivalent |
| 114 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3connected to earthing testing pointall as specified or indicated including testing on completions complete all as specified and directed by Engr in Charge. |
| 115 | M & L for PCC 1:4:8 type D-2, 100mm thick, using 40mm graded stone aggregate as in sub base complete all as specified and directed by Engr in Charge. |
| 116 | M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed by Engr in Charge. |
| 117 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick with greypigment cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cementcomplete all as specified and directed by Engr in Charge. |
| 118 | M&L for hardcore of gurage n exc. 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engr in Charge. |
| 119 | M&L Machine pressed precast concrete interlocking paver block With Grey Cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed by Engr in Charge. |
| 120 | Supply only fine aggregate for sand cushining complete all as specified and directed by Engr in Charge. |
| 121 | M&L For PCC type B1(1:2:4) using 20 mm graded cushed stone agg as in coping ,benching and the like incl form work complete all as specified and directed by Engr in Charge. |
| 122 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed by Engr in Charge. |
| 123 | M&l for PCC 1:3:6 type C2 (40mm graded aggregate) for post holes complete all as specified and directed by Engr in Charge. |
| 124 | M&L mild steel work as in posts and struts in fencing including cutting tops to shape as diercted, drilling holes, notching for wire, ect F.I fillets (for securing wire mesh etc) incl all necessary drilling, bolting or riveting etc and similar work confirming to Fe -209 Gde E-165 complete all as specified and directed by Engr in Charge. |
| 125 | S&F mild steel screw bolts diameter of neck 11 to 15mm(Machine made ) with hexagonal or square heads at on end and screwed the other, or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 10 cm andn.exc 15cm long complete all as specified and directed by Engr in Charge. |
| 126 | Supply only chain link M S galvanised fencing any size or type complete all as specified and directed by Engr in Charge. |
| 127 | Fixing only chain link fencing including line wires to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed by Engr in Charge. |
| 128 | M & Lfor 10mm round bars Fe 410W (Gde -250)dia and over cut to length bentto shape as required including binding withmild steel annelid wire not less than 0.90mm dia complete all as specified and directed by Engr in Charge. |
| 129 | M&L for Galvanised , 2 strand , steel barbed wire 2.4 mm dia barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild wire staples or steel pins etc s directed (each line wire to be measured) complete all as specified and directed by Engr in Charge. |
| 130 | M&L removing excavated material n. exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point.type of soil complete all as specified and directed by Engr in Charge. |
| 131 | M&L for preparation of new steel surfaces of any description exc over 10cm with or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr in Charge. |
| 132 | Schedule of Credit |