| 1 | SCH \"A\" PART-I: BUILDING/STRUCTURESNote: This schedule is pre-priced by MES and the rate indicated as under Col 6 signifies this fact only |
| 2 | Total amount of Sch \"A\" Part-I (Buildings and Structures) |
| 3 | Total amount of Sch \"A\" Part-II (Site Clearance, Excavation and Earthwork) |
| 4 | Total amount of Sch \"A\" Part-III (Internal Water Supply) |
| 5 | Total amount of Sch \"A\" Part-IV (Internal Electric Supply) |
| 6 | Total amount of Sch \"A\" Part-V (Road, Paths & Culverts ) |
| 7 | Total amount of Sch \"A\" Part-VI (Sewage Disposal) |
| 8 | Total amount of Sch \"A\" Part-VII (Area Drainage) |
| 9 | Total amount of Sch \"A\" Part VIII (External Water Supply) |
| 10 | Total amount of Sch \"A\" Part-IX (External Electric Supply) |
| 11 | Total amount of Sch \"A\" Part-X (Hot Water Supply) |
| 12 | SCHEDULE \"A\" PART-XI (MISCELLANEOUS B/R AND E/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as \"Rs 0.00\" under Col 6 signifies this fact only. |
| 13 | S&F Modular switch, single pole, two-way 6 Amp, 230V AC, 50 Hz complete all as specified and directed. |
| 14 | S&F LED tube light fittings including LED tube decorative ultra slim linear fixture with extruded aluminium heat sink environmental friendly Energy efficient ready to use pack, 20 Watt, surface mounting type extruded PVC, snap on installers and domestic electronic Driver, connector block etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable complete with all as specified and directed. Make: HAVELLS LED PRIDE ESSENTIAL Cat No LHEXAWP7UN1W020 or equivalent makes CG/Philips/Wipro. |
| 15 | S&F LED 9W B22 CDL INVERTER BULB having colour temp 6500 K and lumen output 900 suitable for B-22 type to fix on batten holder and wall light etc complete all as specified and directed. Make: Havells cat No LED 9 W B22 CDL INVERTER BULB V2 LHLDDDHAIC4N009 Equivalent make: CG/Philips/Wipro. |
| 16 | S&F Factory made powder coated sheet metal enclosure, TPN Vertical Distribution Boards with MCCB four pole 25 KA, 100 Amp with fixed thermal and magnetic settings as incomer IP43 protection Double Door Plain 4 way with suitable rated busbar, neutral link, and MCB SP/TP as outgoings complete all as specified and directed.Note: MCCB and MCBs shall be measured and paid separately. |
| 17 | S&F MCCB 4 Pole, 415 V, adjustable type, 100 Amps with breaking capacity 25 KA and making connection with suitable size of copper lugs etc complete all as specified and as directed. |
| 18 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of crusher sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 19 | M&L Construction of valve pit/chamber of Internal dimensions 900 mm x 900 mm x 900 mm, using PCC 1:4:8, type D-2, using 40mm graded stone aggregates for foundation, 23 cm thick, brick wall built in cement mortar (1:4), 15 mm thick rendering all around the brick work in cement mortar (1:6), 75 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregates in coping including necessary form work, 3 coats of white wash on rendered surfaces and on coping, 5 mm thick mild steel top sheet cover with frame made out of 40x40x6 mm angle iron, locking arrangement, including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed. |
| 20 | M&L Cutting existing 150 mm dia pipe for inserting Tee of size 150x150x100mm Including lead joint and excavation etc complete all as specified and directed. |
| 21 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 50 mm including 90 degree bends with coupler and rubber ring, conforming to IS: 16205 Part 24, 450 N laid in trenches for cable protection complete, all as specified and as directed. |
| 22 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 63 mm including 90 degree bends with coupler and rubber ring, conforming to IS: 16205 Part 24, 450 N laid in trenches for cable protection complete, all as specified and as directed. |
| 23 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 110 mm including 90 degree bends with coupler and rubber ring, conforming to IS:16205 Part 24, 450 N laid in trenches for cable protection complete, all as specified and as directed. |
| 24 | M&L Sword type single arm 1 meter long brackets made out of hot dip galvanised and painting the bracket and clamps with 2 coats of synthetic enamel paint over a coat of red oxide Zinc chromate primer all as specified and directed. |
| 25 | S&F PVC weather proof, hinged door, junction box of size 250 x 200 x 100 mm with Aluminium bus bar, 240V, Neutral link and 1 No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc all as specified and directed. |
| 26 | S&F PVC insulated and over all PVC sheathed, stranded copper conductor wire 1.5 sqmm x 3 core ISI marked. Complete from light fitting to pole junction box complete all as specified. |
| 27 | Supply installing commissioning & testing LT feeder piller panel board factory made, out door, cubical type, vermin proof, dust proof, water proof made out of 3.15 mm thick CRCA sheet and angle iron frame of size 50x50x6 mm inside depth not less than 50 cm and size suitable to accommodate the following accessories with insulated TPN Aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. both side openable (front & back) with locking arrangement duly painted with coat of synthetic enamel paint over a coat of red oxide primer both internally and externally and connecting with cable with lugs including internal wiring with copper cable of suitable size using lugs compressing the following accessories all as directed. (Notes: The rate quoted shall include for earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board ) and Aluminium bus bar 300 Amps-04 Nos phases and duly colour sleeved mounted on epoxy insulators-01 set. Note: Panel board shall be approved by CPRI and certificate to be produced and to be |
| 28 | Incoming:-(a) MCCB 4 P, 415 Volt 200 Amps, 36KA, 50 Hz with fixed thermal and magnetic setting-01 NoOutgoing:-(a) MCCB 4 P, 415 Volt 100 Amps, 25 KA, 50 Hz with fixed thermal and magnetic setting-03 Nos.(b) MCB 2P, 415 Volt 32 Amp, 10 KA, 50 Hz for Street Light fixed thermal and magnetic setting-01 No(c) MCB 3P, 415 Volt 32 Amp, 10 KA, 50 Hz -01 No(d) MCB 2P, 415 Volt 16 Amp, 10 KA, 50 Hz -01 No(e) Automatic street light ON/OFF timer of capacity not less than 16 A, 3 phase, 3 Pole with suitable capacity of contactor, relays, control wiring and all accessories all as specified.(f) Multifunction Digital square type intelligent panel meter to measure voltage, current, frequency, & Power factor - 01 No. |
| 29 | Supply, installing, connecting, testing and commissioning of storage type water cooler with inbuilt UV purifier of storage capacity 120 Lts and cooling capacity 60 Lts with storage tank, all body material made out of stainless steel SS-304 of size and 2 Nos of faucets one for cold water and one for normal water including 3 stages of purification (Sedimentation/Carbon/ UV filtration) with operating temperature 15°C to 45°C and working with AC, 180-250 Volts supply complete to existing power sockets with 3 Core 1.5sqmm PVC multi standard copper wire complete all as specified and directed. |
| 30 | S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as specified and as directed by Engr-in-Charge. Makes :- Automatic electrical (AE)/ Vinitec/APLAB/V Guard |
| 31 | Supply, laying, jointing and testing of 100 mm Ductile iron pipes with spigot and socket ends, centrifugally cast, class K-7 confirming to IS-8329, in any length, laid in trenches/pipe supports etc, pressure testing after laying complete as per IS-12288 including styrene butadiene rubber gasket joints, complete all as specified and as directed by Engr-in-Charge. Note: Tyton Joints required are deemed to be included in the unit rate. |
| 32 | Supply and install of 8 m Octagonal Hot dipped Galvanized Street light poles of top dia 70 mm bottom dia 130 mm Sheet thickness 3 mm, Base Plate 200 x 200 x 16 mm along with foundation of min size 450 x 450 mm and depth 1600 mm with RCC foundation and foundation bolts as per OEM recommendation/site requirements all as specified and directed. |
| 33 | Removal of existing reinforced concrete piles, pile caps, or any other buried concrete obstructions of the old demolished structure encountered during excavation, including careful exposure, cutting or breaking by mechanical means (such as pneumatic breaker or coring machine), removal of reinforcement, disposal of debris to approved location, backfilling and compaction of resulting void with approved soil in layers, and sealing of cut surface where required-all complete as directed by the Engineer-in-Charge\". Note: (i) The volume of such concrete obstruction (pile/pile cap) removed shall be excluded from the measurement of earthwork excavation to avoid double payment. (ii) Excavation required to expose the obstruction is deemed included in the main excavation item. (iii) The rate shall include all labour, materials, tools, plants, cutting/breaking equipment, dewatering (if required), safety measures, transport, and disposal. |