| 1 | Carrying out preventive maintenance of heavy duty electrically operated Hangar gate of size 10.00 m X 5.00 m to make it in serviceable conditions alongwith complete servicing of the mechanism of doorfor Remote / Manual operated Gate comprising of motor, gear box, chain, contactor, relay, hooter, timer and control panel etc., installed at main panel & wiring, limit switch / MCBof the gate with and including dismantling and replacement of all unserviceable parts of Gear box, motor and panel with new parts at its installed locations complete all as specified and directed. Note: - Cost of Oiling, Greasing and labour charge of the replacement of various spare parts shall be deemed included in the unit rate of this item. Spare parts shall be measured and paid separately under respective items of this schedule. |
| 2 | Supply and fix following spare parts and accessories of Hangar Gate having same specifications of existing spares complete all as specified and directed: - |
| 3 | Supply only4 core, 2.50 Sqmm size flexible copper conductor cable, PVC insulated and sheathed, 1100 volts grade multi stranded suitable for box girder between control panel to all motors medium grade PVC conduit ISI Marked not less than 25 mm dia for Hangar door complete all as specified and directed |
| 4 | Supply only4 core, 4.00 Sqmm size flexible copper conductor cable, PVC insulated and sheathed, 1100 volts grade multi stranded suitable for box girder between control panel to all motors in medium grade PVC conduit ISI Marked not less than 25 mm dia for Hangar door complete all as specified and directed |
| 5 | Material and Labour for sub main wiring complete with 2 single core multi stranded copper conductor 6 sqmm (Nominal area) PVC insulated unsheathed cabledrawn in and including medium grade PVC conduit ISI Marked not less than 25 mm dia concealed, including making good disturbedsurface, of wall, including single core multi stranded copper conductor 6 sqmm sizeas earth wire drawn in same conduit complete all as specified and directed .Note: One run of 02 single core copper wire and 01 run of 6 Sqmm copper wire and 01 run of conduit 01 run of earth conductor6 Sqmm wire shall be measured as one unit. |
| 6 | Supply only 3 HP motor starter capacity forsuitable complete all as specified and directed. |
| 7 | Supply only geared rotary limit switch 3 phase, 415 volts, 50 Hz, 10 Ampere, No. 22-1210-2 KV suitable for hangar doors any capacity and any motion complete all as specified and directed |
| 8 | Supply onlyTriple Pole contactor, 3 phase, 20 Amperes with coilcomplete all as specified and directed |
| 9 | Supply only Teeth gear of chain required for operating of Hanger Gate complete all as specified and directed |
| 10 | Supply only Chain of teeth gear required for operating of Hanger Gate complete all as specified and directed |
| 11 | Supply only Drive End Ball bearing and Non Drive End Ball bearing having No. 6205 suitable for 3 phase induction motor, 1.5 KW, AC complete all as specified and directed |
| 12 | Supply only MCB TP 20 Ampere, \"C\" curve complete all as specified and directed |
| 13 | Supply only Motor protection circuit Breaker switch, 415 volts suitable for 3 phase 1.5 KW Induction motor with thermal protection adjusting range 2.5-4.0 complete all as specified and directed |
| 14 | Supply only MCB single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series complete all as specified and directed. |
| 15 | Supply onlyMCB TPN 415 Volts, 40 Amps, 50 Hz, 10 KA \"C\" series complete all as specified and directed. |
| 16 | Supply only Mini contactor AC, 3 pole upto 6 Ampere, 415 volts, 50 Hz. complete all as specified and directed. Make : ABB/Siemens/Indo asian |
| 17 | S&F flexible cable carrier complete all as specifiedand directed |
| 18 | Supply only push button switch for hangar doors with elements 6 Amp, 415 volts, 50 Hz complete all as specified and directed |
| 19 | Cutting and removing of old unserviceable / burnt winding wire and M & L for rewinding of stator of 3 phase, 1.5 KW , AC motor, by using super enamelled copper wire as per existing size with and including varnishing thereof and insulation of class \"F\" complete all as specified and directed. |
| 20 | Cutting and removing of old unserviceable / burnt winding wire and M & L for rewinding of stator of 3 phase, 2.5 KW , AC motor, by using super enamelled copper wire as per existing size with and including varnishing thereof and insulation of class \"F\" complete all as specified and directed. |
| 21 | Cutting and removing of old unserviceable / burnt winding wire and M & L for rewinding of stator of 3 phase, 4 KW , AC motor, by using super enamelled copper wire as per existing size with and including varnishing thereof and insulation of class \"F\" complete all as specified and directed. |
| 22 | Cutting and removing of old unserviceable / burnt winding wire and M & L for rewinding of F100 rotor of 3 phase, 1.5 KW , AC motor, by using super enamelled copper wire as per existing size with and including varnishing thereof and insulation of class \"F\" complete all as specified and directed. |
| 23 | Cutting and removing of old unserviceable / burnt winding wire and M & L for rewinding of F100 rotor of 3 phase, 2.5 KW, AC motor, by using super enamelled copper wire as per existing size with and including varnishing thereof and insulation of class \"F\" complete all as specified and directed. |
| 24 | Cutting and removing of old unserviceable / burnt winding wire and M & L for rewinding of F100 rotor of 3 phase, 4 KW , AC motor, by using super enamelled copper wire as per existing size with and including varnishing thereof and insulation of class \"F\" complete all as specified and directed. |
| 25 | FIRE ALARM |
| 26 | Carrying out preventive maintenance of fire alarm control panel (2 loop DC) complete with mounting battery of as per existingmake and capacity including dismantling and replacement of minor spare partscomplete all as specified and directed. Note: - Cost ofspare parts shall be deemed included in the unit rate of this item. |
| 27 | Supply and fixing following spare parts and accessories of Fire alarm systemhaving same specifications of existing spare complete all as specified and directed: - |
| 28 | Supply, commissioning and testing of analogue addressable Multi-Detector as per existing make having removable high performance chamber with Twin fire LEDs allow 360° viewing, lock mechanism (sensor to base), Variable sensitivity, Electronically addressed along with mounting base duly approved by LPCB including taking out old unserviceable necessary connections complete all as specified and directed. |
| 29 | Supply, commissioning and testing of analogue addressable Manual Call pointas per existing make ESP Analogue Addressable Protocol having status LED for Alarming and standby mode, Electronically addressed, resettable type duly approved by LPCBincluding taking out old unserviceable necessary connections complete all as specified and directed. |
| 30 | Supply, commissioning and testing of analogue Addressable loop powered wall sounderas per existing make with flasher providing multi Volume levels and multi Tones with a maximum output of up to 102 dB(A) with low current consumption,fitted on Isolator Type Base which is fully compatible with ESP Analogue Addressable Protocol, User selectable modes, Electronically addressed duly approved by LPCB including taking out old unserviceable necessary connections complete all as specified and directed. |
| 31 | Supply and fixing of replacement of maintenance free12 volt 7 AHbattery complete all as specified and directed. |
| 32 | Supply, commissioning and testing of response Indicator complete all as specified and directedincluding taking out old unserviceable necessary connections complete all as specified and directed. |
| 33 | Supply and laying submain FRLS electric cable 02 run of two Core 1.50 Sqmm multi-stranded armoured copper conductor for wiring of fire detectors with all accessories and cable pointers or shall be painted with FIRE RED tags at an interval of every 1.00 Metre in PVC conduit complete all as specified and directed. |
| 34 | Supply and laying of rigid non - metallicPVC conduit including of all tees, bends, elbow, reducer, bellmouth tube ends and fixing accessories such as couplers, locks nuts, saddles, pipe hooks etc of size 25 mm complete all as specified and directed. |
| 35 | Supply, commissioning and testing of addressable control module completeas per existing make mounting wall/roof/ceilingincluding taking out old unserviceable necessary connections complete all as specified and directed. |
| 36 | Supply, commissioning and testing of addressable fault detector completeas per existing make mounting wall/roof/ceilingincluding taking out old unserviceable necessary connections complete all as specified and directed. |
| 37 | Supply, commissioning and testing of addressable fire alarm control panel (2 loop DC) complete with mounting battery of suitable capacity in hydraulic lab & RT Cabin including taking out old unserviceable necessary connections complete all as specified and directed. |
| 38 | Supply, commissioning and testing of addressable fire alarm control panel (4 loop DC) complete with mounting battery of suitable capacity in signal section including taking out old unserviceable necessary connections complete all as specified and directed. |