| 1 | M& L for demolition of cement concrete of any description in any position not otherwise specifically provided including existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime coba 80 to 100mm thick mud phuska/cement concrete/lime coba etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush and removing debries/rubbish off materials out side of Ministry of defence (MOD) land complete all as specified and directed. |
| 2 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. |
| 3 | Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 4 | M & LPlain cement concrete (1:2:4) type B0 using 12.5 mm graded stone agg as in coping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and directed. |
| 5 | M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stilgreen finished even and fair including mixing ofwater proofing compound as per manufacturer instructionetc complete all as specified and as directed.Note :- Water proofing compound shall be measured separately |
| 6 | Supply only integral water proofing compound complete all as specified and as directed. |
| 7 | M&L applying water proofing treatment with the following(a) First coat of bitumen primer conforming to IS-3384 @ 0.3Kg / sqm to be applied on prepared surface till the surface is properly impregnated.(b) after the application of approved bituminous primer the water proofing memberne minimum weight 3kg/sqm and minimum 3mm thick reinforced with polyesterd non woven fabric (weight not less then 160gms/sqm) shall be laid on the primed surface by torch application method as per manufactured instruction.(c) All joints and change in direction should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag on cement and cured well before laying of membrane including Aluminium paint on top surface |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding, (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 9 | M&L for High glossy dark shed Valenza Glazed Vitrified Tiles 8-9 mm thick (square/ rectangular),area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm,polished, in floors etc.jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 10 | M&L for High glossy dark shed Valenza Glazed Vitrified Tiles 8-9 mm thick (square/ rectangular), area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm,as in skirtingfixed over and including 10 mm thick cement screed in (1:4 ) CM set and jointed in neat cement slurryand pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed. |
| 11 | M&L for non skid colouredceramic tiles 7 to 8 mm thick (400mm x 400mm) in floors etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match to floor etc completeall as specified and as directed. |
| 12 | M&L for glazed white tiles 450x300x7mm thick for work on vertical surface, set & jointed in cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed |
| 13 | M&L 25mm thk PCC 1:2:4 type B-0 using 12.5 mm graded agg as in flooring finished fair and even without using extra cement complete all as specified and as directed. |
| 14 | M&L, screed bed or bedding layer of mortar 15 mm thick in cement mortar 1: 6 to receive tiles etc finished rough complete all as specified and directed. |
| 15 | Taking down plaster on brick or stone wall, ceiling etc incl racking out joints hacking for keys scrubbing down with water etc complete all as specified and directed. |
| 16 | M & L 15 mm thick rendering on other than fair faces of brick work or concrete surface in cm 1:6 to be finished fair and even with out suing extra cement complete all as specified and directed. |
| 17 | M&L for external rendering 15 mm thick in CM 1:4 mixed with [email protected]/ bag by weight of cement on brick work or concrete surfaces of wall finished even and fair complete all as specified .Note-WPC shall be measured and paid seperately. |
| 18 | M & L for complete removal of existing treatment from surface ofwall all as specified and as directed by the Engineer-in-Charge |
| 19 | M & L for applying water proof 3 mm putty on wall in 3 layer (each layer should be 1 mm) all as specified and as directed by the Engineer-in-Charge |
| 20 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces.complete all as specified and directed. |
| 21 | M & L for applying two coat of oil bound distemper all as specified and as directed by the Engineer-in-Charge |
| 22 | M & L for preparation of oldceiling surfaces and applyingtwo coats of white wash complete all as specified and directed. |
| 23 | M&L one coat synthetic enamel paint on old wooden surface incl prepartion of old surfaceof any description not otherwise described over 10 cm width or girth etc complete all as specified and as directed |
| 24 | Demolition of cement concrete(un Reinforced) of any description in any position not otherwise specifically provided for etc. complete all as specified and directed. |
| 25 | M&L, Hardcore of guage n exc 63mm deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled/rammed to a true surface Broken stone or boulders complete all as specified and directed. |
| 26 | Material and labour 75 mm thick PCC 1:3:6 type C2 using 40 mm graded aggregate as in plinth protection finished fair and even w/o using extra cement and making groove of 10mm width at every 3m intervals and at diagonals and filling the joints with bitumen mastic( a mix of bitumen and sand in 1:1 by weight) complete all as specified |
| 27 | M&L for Glossy finish rubber molded 60mm thick factory made concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.complete all as specified and as directed. |
| 28 | M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 29 | Taking down PVC soil pipe with fittings from wall, treches of any description including fittings complete all as specified and as directed. |
| 30 | S &F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wallcomplete all as specified and directed. |
| 31 | S &F of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wall complete all as specified and directed. |
| 32 | S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 33 | S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed. |
| 34 | S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed. |
| 35 | Dismantling water tanks and removing to store of capacity exc 500 & n.exc 1000ltrs etc complete all as specified and directed. |
| 36 | S & F 1000ltr rotational moulded polyethylene water storage tanks,(cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-1991 including 20 mm dia GI pipe light grade washout pipe 450 mm long with plug and 20 mm dia GI pipe light grade over flow pipe 600 mm long with fitting and dismantling of existing unserviceable tank and removing from site, complete all as specified and directed. |
| 37 | S&F ball valves of 20 mm bore high pressure of PTMT with empxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed complete all as specified and as directed(Minimum weight 20 gms-210 gms) complete all as specified and as directed |
| 38 | S & F in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs including taking down the existing fitting complete all as specified and as directed. |
| 39 | Taking up or down existing 15mm bore steel tubing and connections including cleaning for refixing or removal complete all as specified and as directed. |
| 40 | Taking up or down existing 20mm bore steel tubing and connections including cleaning for refixing or removal complete all as specified and as directed. |
| 41 | Supplying, fixing, jointing and testing 15mm dia bore galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed. |
| 42 | Supplying, fixing, jointing and testing 20mm dia bore galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed. |
| 43 | Fixing only including jointing and testing 15mm dia bore galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed. |
| 44 | Fixing only including jointing and testing 20mm dia bore galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed. |
| 45 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cuttingexceeding 10 cm but not exceeding 20 cm girth in brick walls complete all as specified and as directed. |
| 46 | Material & Labour for writing letters or figures (block, Roman, Italic or Indian) n.exc.30 cm high complete all as specified and directed. |
| 47 | Demolition ofBrickwork of stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articlesl etc complete all as specified and as directed. |
| 48 | M&L Brick work with sub class B bricks straight or curved on plan exe 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed |
| 49 | S&F in repair 3 mm thick sheet glass, Ordinary quality and glazing with wooden beads in square n. exc 0.5 Sqm in each pane or glazing with oil glass putty including hacking out old broken glass from wooden or steel frame surround complete all as specified and as directed etc complete all as specified and as directed. |
| 50 | S&F, in repair galvanized mild steel wire cloth 0.63 mm nominal dia of wire and avg width of a-pertare 1.40 mm fixed with tinned tacks or galvanized wire staples etc complete all as specified and as directed. |
| 51 | Taking down shutters of any description exc 1 sqm and n.exc 2 Sqm each complete all as specified and as directed. |
| 52 | Refixing of same opening shutters including cleaning and cuttingany description exc 1 sqm and n exc 2 sqm each complete all as specified and directed. |
| 53 | S&F in repairMS butt hinges, cold rolled medium weight 100mm in size complete all as specified and directed. |