| 1 | Taking down cement or cement lime plaster of any description and any thickness on brick, concrete or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer in Charge. |
| 2 | M&L for rendering 15 mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge. |
| 3 | M&L for rendering 15 mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge. |
| 4 | M&L for rendering 5 mm thick cement plaster in CM(1:3) on fair faces ofconcrete surfaces in ceiling, complete all as specified and directed by Engineer in Charge. |
| 5 | M&L for rough cast plaster on brick wall consisting under coat of cement and sand mortar (1:4) not less than 10mm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even, complete all as specified and directed by Engineer in Charge. |
| 6 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed by Engineer in Charge. |
| 7 | M&L for preparation of old decorated surfaces of ceiling and applying one coats of white wash, complete all as specified and directed by Engineer in Charge. |
| 8 | M&L for preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed by Engineer in Charge. |
| 9 | M&L for preparation of old decorated surfaces of walls and applying one coats of white wash, complete all as specified and directed by Engineer in Charge. |
| 10 | M&L for Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper acrylic/distemper oil emulsion acrylic, white or tinted over a coat ofprimer of same make, complete all as specified and directed by Engineer in Charge. |
| 11 | M&L for preparation of old decorated surfaces of walls and applying one coats of oil bound distemper acrylic/ distemper oil emulsion acrylic, white or tinted, complete all as specified and directed by Engineer in Charge. |
| 12 | M&L for complete removal of existing treatment andpreparation of old plastered surfaces of walls and applying two coats of Oil bound distemper acrylic /distemper oil emulsion acrylic, white or tinted over a priming coat of same make on wall surfaces, complete all as specified and directed by Engineer in Charge. |
| 13 | M&L for applying 1.5 mm thick wall care putty (JK/Birla/Berger) on walls, including making surface even and smooth using sand paper before applying Priming coat, complete all as specified and directed by Engineer in Charge. |
| 14 | M&L for preparation of new plastered surfaces of walls, pillars, cornices and applying Two coats of premium quality exterior emulsion paint over priming coat of exterior primer, complete all as specified and directed by Engineer in Charge. |
| 15 | M&L for preparation of old decorated surfaces of walls, pillars, cornices by brooming down etc and applying one coat of premium quality exterior emulsion paint including Scaffolding up to G+2 floors, complete all as specified and directed by Engineer in Charge. |
| 16 | Complete removal of existing treatment on wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust,loose paint up to 15 m Height etc by skilled labour complete all as specified and directed. |
| 17 | M&L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:-Step 1:- Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2:- Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3:- Allow 6-8 hrs time to dry the putty surface.Note:-(a) The work pertaining to periodical services & WaterProofing shall be executed from authorized applicatorthrough manufacturer of which the materials .i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Garrison Engineer.(b) Cost of scaffolding upto 15m height ofbuilding is included in this item. (c) The contractor shall upload along with the documents under cover-l, \"Memorandum of Understanding\" (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected. (d) Masking of window/doors during spray painting usingpolythenefilm will be included. (e) Cleaning and clearing site of paint, mats etc included. (f) 5 years guarantee of painting work will be admissible after date of completion and 15% amount will be reserve against painting work after date of completion for the 05 years. |
| 18 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of cement base primer onnew plastered surfaces, complete all as specified and directed by Engineer in Charge. |
| 19 | M&L for preparation of old decorated surfaces of walls andapplying one coats of cement base paint, complete all as specified and directed by Engineer in Charge. |
| 20 | M&L for complete removal of existing treatmentand preparation of old plastered /unplastered surfaces of walls andapplying two coats of cement base paint, complete all as specified and directed by Engineer in Charge. |
| 21 | M&L for repair to RCC ceiling, sunshades, Chajjas, Balconies, Columns, bands, beams, roof slab and similar RCC work at any position/ height by dismantling loose/ disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcherwith cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes, complete all as specified and directed by Engineer in Charge.Note : The extra area of 300mm around the actual affected area will be checked and repaired and only repaired portion will be taken for measurement. |
| 22 | M&L for Preparation of old wooden surface and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer in Charge. |
| 23 | M&L for preparation of old steel surfaces of any description not otherwise described over 10cm width or grith and applying one coats of synthetic enamel paint over, complete all as specified and directed by Engineer in Charge. |
| 24 | M&L for preparation of previously treated/untreated surface of chequered or interlocking tiles and applying two coats of indigo washable floor paint over a coat of priming paint with 30-40% water, complete all as specified and directed by Engineer in Charge. |
| 25 | M&L for preparation of old painted surfaces of concrete/kerb stone and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer in Charge. |
| 26 | M&L for preparation of old painted surfaces of wall and applying one coat of plastic emulsion paint, complete all as specified and directed by Engineer in Charge. |
| 27 | M&L for Finishing walls with texture paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm, complete all as specified and directed by Engineer in Charge. |
| 28 | M&L for Non woven matt wall paper in approved designs as directed by Enge-in-Charge (Eco friendly/latex saturated 30% recycled 70% renewable cellulose fibres) suitable for residential and interiors having width of rol 76.20 mm and fixed on wall with approved adhesive with an overlapping of 5 cm, complete all as specified and directed by Engineer in Charge. |
| 29 | M&L for complete removal of existing paint on unevenness waterfall fountain surfaces/small boulder surfaces & applying two coat of Latex/Acrylic Paintin different colours shades over primer of same make as per direction of GE including minor repair work/sealing of joints works etc, complete all as specified and directed by Engineer in Charge.(Note : Unevenness fountain surface measured flat for payment, bidders are requested to visit the site before coating the rates) |
| 30 | S&F of 110 mm bore PVC (SWR) pipes (Medium duty) single socketed in any length with rubber ring joints fixed to walls/floor including dismantling of old outlet pipe etc, complete all as specified and directed by Engineer in Charge. |
| 31 | S&F in repair 110 mm bore PVC (SWR) bends any radius, complete all as specified and directed by Engineer in Charge. |
| 32 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washersincl glass self assembly, complete all as specified and directed by Engineer in Charge. |
| 33 | S&F in repairs Drizzle colour fully transparent high grade ABS corner shelve of size of 27x27x36 cm fixing with free screw and wall plug, complete all as specified and directed by Engineer in Charge. |
| 34 | Hacking out old broken glass any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/ spring clips and providing and fixing new ones, complete all as specified and directed by Engineer in Charge. |
| 35 | S&F of sheet glass 4mm thick ordinary quality and glazing with oil putty or fixed withwoodenbeadsin squarenot exc. 0.5 Sqm in each pane, complete all as specified and directed by Engineer in Charge. |
| 36 | S&F of figured glass 4mm thick, pin head type and glazing with oil putty in squarenot exc. 0.5 Sqm in each pane, complete all as specified and directed by Engineer in Charge. |
| 37 | S&F in repair curtain rails, mild steel, chromium plated including fixing brackets, both ends decorative nobs, complete all as specified and directed by Engineer in Charge. |
| 38 | S&F in repairs rubber door seal on both sides of bottom rail with bottom of shutter fix with screw complete all as specified and directed |
| 39 | S&F in repair 20 mm dia D type CP towel rail 600 mm long between flanges, complete all as specified and directed by Engineer in Charge. |
| 40 | S&F in repair CP soap dish fixed to wall with brass chromium plated screws, complete all as specified and directed by Engineer in Charge. |
| 41 | Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc of capacity up to 1000 ltr and writing the date of cleaning on water tank with white paint, complete all as specified and directed by Engineer in Charge. |
| 42 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar, complete all as specified and directed by Engineer in Charge. |
| 43 | M&L for brick work with subclass B bricks, straight or curved on plan exc 6 m mean radius , buit in cement mortar (1:6), complete all as specified and directed by Engineer in Charge. |
| 44 | M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive Colorstay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications,Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. (Make: ASIAN, BERGER and DULEX)Note:-(a) The workpertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b) Cost of scaffolding upto 15 hight of building included in this item. (c) The contractor shall upload along with the documents under cover-I, \"Memorandum of Understanding\" (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected. (d) 05 years guarantee of painting work will be admissible after date of completion and 15% amount will be reserve against painting work after date of completion for the 05 years. |