| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises. |
| 2 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified. |
| 3 | M&L for Glazed ceramic tiles in vertical surface 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing coat of cement mortar in 1:4 complete all as specified. |
| 4 | Taking down cement or cement limeplaster on brick or stone walls, etc. including raking out joints,hacking for key,scrubbing down with water, etc. |
| 5 | M&L for rendering 15 mm thick on other than fair faces of brick wall or concrete surface in cement mortar 1:4 finished even & fair all as specified and directed mixed with water proofing compound.Note:-WPC will be measured and paid separately under relevant item of this BOQ. |
| 6 | Supply only liquid water Proofing Compound. |
| 7 | M&L for Rendering 15 mm thick on other than fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth in CM 1:6 complete. |
| 8 | M&L for preparationof new plastered surface of wall and applying two coats of Oil Bound Distemper over a coat of primer complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for preparation of new plastered surface of walls and applying two coats of cement base paint over a coat of primer complete all as specified. |
| 10 | M&L for 10mm thick rendering on fair faces of brick/concrte surface as in ceiling in cement mortar 1:3 finished the surface even and smooth without using extra cement and applying threecoats of white washon ceiling surface complete all as specified and directedcomplete all as specified and as directed. |
| 11 | M&L for 50 mm thick PCC 1:3:6 type C1 (using 40 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and fair without using extra cement including demolition of cement concrete of existing plinth complete. |
| 12 | M&L non skid colouredcermic ENDURA tiles exc 0.06 Sqm but n. exc. 0.11 Sqm10 mm thickset and jointed in neat cement slurry & pointed with coloured cement to match in floor over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 13 | Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles |
| 14 | M&L for Brick work with sub class\"B\" bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed. |
| 15 | M&L for Brick work with sub class \"B\" brick straight or curved on planto any radius in half brick thick walls in CM 1:4 complete. |
| 16 | S&F in repair 75 mm dia PVC floor trap plain with grating including jointing with solvent cement complete all as specified. |
| 17 | S&F in repair 75 mm dia PVC (SWR) bends any radius complete all as specified. |
| 18 | S&F in repair 110 mm dia PVC(SWR) plain bends any radius complete all as specifiedand directed. |
| 19 | S&F in repair 75 mm dia PVC (SWR)pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 20 | S&F in erpair PVC (SWR) 110 mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 21 | S&F in repair PVC (SWR) 110 mm dia pipes single socketed, in any length with rubber ring joints, fixed on wallscomplete all as specified. |
| 22 | Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed |
| 23 | Taking up or down 20 mm bore steel tubing and connections, complete all as specified and as directed |
| 24 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth of brick walls complete all as specified. |
| 25 | S&F 15 mm bore galvanised steel water tubing, medium grade including necessary fittingssuch as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line all asspecified and as directed by Engineer-in-Charge. |
| 26 | S&F 20 mm bore galvanised steel water tubing, medium grade including necessary fittingssuch as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line all asspecified and as directed by Engineer-in-Charge. |
| 27 | S&F long body bib taps cast copper alloy, chromium plated, fancy type with half turm handle having weight of bib tap should not be less than 450 gms or as per SSR Part-I specification for iron pipes15 mm bore dia complete all as specified and as directed. |
| 28 | S&F in repair fancy type 15 mm size long body angular cock, cast copper alloy, chromium plated, fancy type with capstan head having weight of angular cock should not be less than 450 gms or s per SSR Part-I specification, screwed down, screwed both end for iron pipes complete. |
| 29 | S&F in repairs stop valve, 15 mm chromium plated with long shank and cup (Concealed type) both ends for iron pipe |
| 30 | S&F in repair vitreous china wash hand basin white flat back size 550 x 400 mm including bracket and pair of rack bolts waste coupling pillar tap cast copper alloy chromium plated fancy type complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in repairs 15 mm dia brass chromium plated pillar taplong shank with fly nuts capastan head screwed down high pressure with or without lettered hot or cold with long screwed shank having weight of pillar tap should not be less than 450 gms or as per SSR Part-I specification complete. |
| 32 | S&F in repairs 750 mm long PVC flexible waste pipe 32 mm dia for fixing in urinals and wash basin complete. |
| 33 | S&F in repairdesigner looking mirror of size not less than 1.0 Sqm,selected quality5 mm thick, fixed with chromium plated screws complete all as specified and as directed. |
| 34 | S&F Swivel CP shower of size 200 mm for fixing with 15mm pipe (minimum weight 40gms) complete all as specified and as directed. |
| 35 | S&FShower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum weight 40gms) complete all as specified and as directed. |
| 36 | S & F in repairs Viterous china squatting pan, Órissa\" pattern, size 580 x 440mm white, with integral foot rests including connection and fitting to trap, and to flushing pipe complete and making good to wall or floor tilling to match the existing complete all as specified. |
| 37 | S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat, white, closed pattern with flat bottom, and cover with aluminised hinging device, complete all specified and as directed. |
| 38 | S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, aluminium brackets for bottom support fixing with gitties embeded in wall with drilling machine etc complete. |
| 39 | S&F in repairtwo way angle cock cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes 15 mm bore dia weight of two way angle cock should not be less than 450 gms or as per SSR Part-I specificationcomplete all as specified and as directed. |
| 40 | S&F in repair Health faucet of superior quality ABS body with 8 mm dia 1.2 m long flexible tube and wall hook complete all as specified and as directed. |
| 41 | S&F in repair 600 mm long PVC connections 15 mm size with PTMT nuts at both end complete. |
| 42 | S&F in repairs stainless steel towel ring 600 mm long 20 mm diafixed with steel screw etc complete all as specified. |
| 43 | S&F in repair stainless soap dish fixed to wall complete all as specified and directed. |
| 44 | S&F in repair 20 mm dia Gun metal, globe or gate valves,with iron wheel head,including making thread to both ends of pipes for fixing,screwed both ends for iron pipes and fixed. |
| 45 | Taking down chowkhats or frame with shutter (without taking off shutters from the frame) area n.exc. 1.50 Sqm each and making good the disturbed surface complete all as specified. |
| 46 | S&F Solid WPC Door Frame of size 50mm x 47mm complete all as specified and as directed. |
| 47 | S&F30 mm thick factory made WPC door with both side lamination complete all as specified and as directed. |
| 48 | Supply and fix 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 49 | Supply & fix 100mm long hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 |
| 50 | S&F 200 mm size aluminium anodized barrel tower bolts of extruded section and fixed. |
| 51 | S&F 150 mm long aluminium anodised handle fabricatedtype all as specified and as directed by Engineer-In-Charge. |
| 52 | S&F powder coated Aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 53 | M&L for powder coated aluminium window shutters (Thickness or powder coating not less than 50 micron)., side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1 no.) complete all as specified. |
| 54 | S&F 5.5 mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane. |
| 55 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165. |
| 56 | Supply & Fix stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples. |
| 57 | Supply and fix in repair 1000 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and includingBall valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm bore dia complete all as specified and as directed.Make:-Sintex Pure,Vactus Smart,Supreme White. |
| 58 | Supply and fix in repair 500 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and includingBall valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm bore dia complete all as specified and as directed.Make:-Sintex Pure,Vactus Smart,Supreme White. |
| 59 | Demolition of Stone slabs and tiles of any description or thickness (except ceramic tiles) in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed. |
| 60 | M&L for 16-18 mm thick Graniteslab work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like laid over and including 15mm thick screed bed in cement mortar 1:4 and pointing in white cement (1:2 )using marble dust with admixture of pigment to match with shade of granite, including rounded/half rounded edge and providing hole for gas pipe in pre-cast slab as well as in granite slab of cooking platformcomplete all as specified and as directed. |
| 61 | Demolition of old roof treatment of any type and thickness and pattern and dismantling of old brick tiles preparation of RCC roof surfaces with wire brushes to remove the old treatment, foreing material loose particlesincluding padding etc complete all as specified and as directed. |
| 62 | M&L for 40 mm thick (avg) thickness cement concrete 1:2:4 type B0 (using 12.5 mm graded aggregate) as in padding finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 63 | M&L for bitumen felt water proofing treatment using APP based polymeric membrane minimum weighting 3kg/sqm and minimum thickness 3mm reinforced with polyster non wove fabric (but not less than 150gms/sqm) laid over bitumen primer applied @ 0.30 Kg/sqm by forced application complete all as specified and as directed. |
| 64 | M&L for cement concrete tiles 25cm x 25cm x 22mm thick, with grey cement and no pigments, machine pressed, set in neat cement slurry in floor over and including 15 mm thick screed bed in cement mortar 1:4 and filling the joints with roof joint filler as per manufacturer specification complete all as specified and as directed.Note:Rate of joint filler is included in this item and no extra rate will be paid. |
| 65 | M&L for cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in surface drain, benchings etc complete all as specified and as directed. |
| 66 | Demolition of reinforced cement concrete as in cover slabs/roof slabs of any description not otherwise specially provided for (reinforcement cut as required to faciliate demolition) complete allas specified and as directed. |
| 67 | M&L for Precast factory made perforated heavy duty (HD-20) cover for drain weight of cover should not be less than 120 kg/Each ,flat iron should be embedded on girth of cover Manhole cover of size .60x1.20m heavy duty HD-20 Cement Concrete 1:2:4 type B1 (using 20mm graded stone aggregate) all as specified and directed. |
| 68 | M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement morter 1:4 and finishing the surfaces even & smooth without using extra cement complete all as specified and as directed. |
| 69 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 70 | Construction of Soakage well of 1.80 mtr dia and 3.0 mtr deep complete all as specified and as shown in drawing No CEJZ/2004/S-35 sheet 1/1 dated 11 May 2004 (Revised 06-08-2005) which includes the following:-(i)Excavation and earth work, including R/F and removal of surplus soil.(ii)Cement concrete in foundation, brick work honey comb brick work.(iii)Reinforced cement concrete, form work, reinforcement(iv)Precast cover slab, plastering, filling brick agreggate and all Pipes and fitting complete all as shown in drawingas specified and as directed. |
| 71 | Obliterating old writing of any description with synthetic enamel paint n.exc 0.10 sqm each to match the existing work complete. |
| 72 | M&L for Writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 Cm high. |
| 73 | Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc. ) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fittings etc) and removing the materialfrom site and making good the disturbed surfaces of walls ceiling etc complete all as directed.( Note: Credit for above items should be made as per credit Schedule separately) |
| 74 | Taking down carefully by submain wiring of any type complete and making good disturbed sufaces to match with the existing surfaces all as directed by Engineer-in-Charge. |
| 75 | Taking down old unserviceable existing SPN/TPN DBs / enclousers any size and type / any descriptions as iron sheet scrapincluding MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed |
| 76 | M & L for Point wiring with 1.5 sqmm (nominal area) single core PVC insulated sheathed (FRLSH) cable, 1100 volts grade, multi-stranded copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20 mm dia med gd) and its all accessories complete concealed in wall and modular flush metal boxes with modular cover plates & frames for mounting modular switches, sockets, regulators etc. including earth wire ofPVC insulated (FRLSH) copper conductor multistranded of 1.5 sqmm size in green colour complete all asspecified in current SSR Part-I & II & directed by the Engineer-in-Charge, as described below for item no 77-80:- |
| 77 | (a) One light point controlled by one switch 5 amp. |
| 78 | (b) One exhaust fan point controlled by one switch 5 amp. |
| 79 | (c) One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified. |
| 80 | (d) One 5 Amp 5 pin socket outlet point on independent board with other switches including earth wire as specified. |
| 81 | All as per item No.76 here-in-above but for 3 pin/ 5 pin, sockets outlet,15 amps with 4.0 sqmm PVC insulated & unsheathed (FRLSH), multi-stranded copper condutor cable, independent, Point wiring complete all as specified and as directed . |
| 82 | M&L ceiling rose, PVC / polycarbonate, isolated body 65mm x 50mm three terminals complete all as specified. |
| 83 | S&F switch piano, flush type single pole, one way 5 amps |
| 84 | S&F switch piano, flush type single pole, one way 15 amps |
| 85 | S/F socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified. |
| 86 | S/F socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified. |
| 87 | S&F Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten |
| 88 | Supply and fixing LED lamp, 9 watt, B-22 base complete. |
| 89 | S&F indoor decorative ultra slim surface/ wall mounted LED batten tube light fitting complete, 1x 20 watt with polycarbonate channel housing & integrated electronic driver, energy efficient, 140V-270 volts, co- related colour temperature (CCT) of 6500K,>100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with pvc insulated pvc sheathed twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. |
| 90 | S&F indoor decorative ultra slim surface/ wall mounted LED batten tube light fitting complete, 1x 10 watt with polycarbonate channel housing & integrated electronic driver, energy efficient, 140V-270 volts, co- related colour temperature (CCT) of 6500K,>100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with pvc insulated pvc sheathed twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. |
| 91 | Supply and install of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainablewith heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- relatedcolour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280Vincluding all connections complete all as specified. |
| 92 | M&L for building securitylight bracket made out of 40mm dia light grade GI pipe |
| 93 | M & L for Sub Main Wiring for DB to DB with two runs single core 10 Sqmm PVC insulated unsheathed(FRLSH) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roofwith and including 10 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge.(02 run 10 Sq mm single core cable,one run of 10 Sq mmearth wire & One run ofPVC conduitwill measured as one RM). |
| 94 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers |
| 95 | Cutting holes for air ducting of exhaust fan in Circle / square shape or as per site |
| 96 | S&FAC Box With 20A SP MCB, Metal Enclosure |
| 97 | S&F MCB distribution board, SPN 8 way, double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified. |
| 98 | S&F MCB SPN, 32 Amps, \"C\" series, breaking cap 10 kA, 240V in MCB DB complete with electrical connection all as specified and directed. |
| 99 | S&F MCB SP, 6-32 Amps, \"C\" series, breaking cap 10 kA, 240V in MCB DB complete with electrical connection all as specified and directed. |
| 100 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, laid in trenches / duct / fixing on walls / poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panelfrom pole / Main Panel Box and testing complete all as specified and directed. Note:- HDPE pipe rate shall be deemed in quoted rate above. |
| 101 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for laying of cable and getting out in soft / loose soil complete all as specified and directed by Engr-in-Charge |
| 102 | Returning, filling in including spreading, levelling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested , all as specified. |
| 103 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. |
| 104 | M&L for earthlingcomplete with galvanizedsteel earth plate eletrode 60x60 cm x6.3 mm thick burred directly in ground(earth pit not less than 2.25 meters deep below ground levelwith topedge of the plate not less than 1.5 Metrsbelow normal ground level connected to galvanizedearthlead wire 4.00mm diaby meansof bolts, nutscheck nutsand washersof galvanizedironor steel all as shown in electrical plateNo.5 connected to earthlingtest pointall as specifiedand indicatedincluding testing on completionincludingexcavation and arth workPCC pit &RCC pit over funnel with wateringpipe wire mesh GI protection pipe etc complete. |