| 1 | Lump sum price worked out by the contractor as per showm on drawing for BUILDING WORKS as listed in Sch ‘A’ PartI. |
| 2 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch \"A\" Part II. |
| 3 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Sch \"A\" Part III. |
| 4 | Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch \"A\" Part IV. |
| 5 | Lump sum price worked out by the contractor for PCC PATH as listed in Sch \"A\" Part V. |
| 6 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY as listed in Sch \"A\" Part VI. |
| 7 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch \"A\" Part VII. |
| 8 | Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTHWORK as listed in Sch \"A\" Part VIII. |
| 9 | Price item wise worked out by the Contractor forSchedule `A\" Part-IX (rate against Srl No. 10.00 shall be quoted by the Contractor) |
| 10 | Bringing earth from out side MoD land n exc. 30 KM, spreading in layers n. Exc. 25 cm thick including watering, spreading, leveling, well ramming and rolling with 8 to 10 tonne power roller complete all as specified and directed. |
| 11 | M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level (with top edge of the plate not less than 1.5 meters below normal ground level) connected to galvanized iron strip 25x4mm as earth lead by means of bolts, nuts, and washers all as shown in Plate No. 5 of SSR Part I of 2009 and connected to earthing test point& to main switch board with and including adequate qauntiy of charcoal dust & common salt in alternate layer around earth plate, 40mm dia pipe light grade for earth lead protection pipe, GI funnel with 20 mm dia medium grade GI pipe for watering and wire mesh including excavation and earth work, PCC pit with 1:3:6 Type C1 (Using 20 mm graded stone aggregate) RCC cover 300 x 300 x 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia plastering 15 mm thick in CM 1:6 externally upto 150 mm below ground level, and disposal of surplus soil complete including testing and writing test results on a 3.0 mm thick painted MS earth pit marking plate (200 mm x 100 mm) duly welded with a 450 mm long 10mm dia round MS rod fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing with old earth pit chambers and removing of debris from the site complete all as specified and directed.Note: - Earth lead wire and its protection pipe upto and including 15 meter only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid separately. |
| 12 | -do- all as above item No 11.00 but galvanised earth lead wire 4mm and 20 mm dia light grade GI earht lead protection pipe complet -ditto- |
| 13 | Supply, installation and commissioning CPRI approved factory fabricated, outdoor type, LT distribution panel box made out of 3.15 mm thick CRCA sheet with projected globe roof for rain water protection, dust and vermin proof, fouble door, both side opening, including neoprene rubber gasket, suitable for 440 Volt, 3 Phae, 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side. Bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeded with 50x50x6mm mild steel angle iron frame and 600mm above the normal ground level complete with internal connection with suitable size of cables glands PCC foundation in cement conrete 1:3:6 (20mm graded stoen aggregate) and testing after installation complete all as specified and directed and comprising of the following: - |
| 14 | (a) Aluminium bus bar 100 Amp-04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB 40 Amp, 415 volt, 16 KA breaking capacity, 4 pole electromagnetic release duly connected to bus bar as incoming-01 No.(c) MCCB TP 32 Amp, 2 Pole, 415 volt, 10 KA breaking capacity, \"B\" curve duly connected to bus bar as outgoing-03 No.(d) MCB SPN 32 Amp, 415 volt, 10 KA breaking capacity, \"B\" curve duly connected to bus bar as outgoing-01 No.(e) Digital Voltmeter 0-500 Volt with selector switch-01 No.(f) Digital Ammeter 0-100 Amp with selector switch-01 No.(g) LED indicating lamps with holder for main supply indicating RYB-01 Set (3 Nos).(h) Instrument fuse holder, fused 4 Amp-06 Nos |
| 15 | S&F flood light bracket made out of GI tubing, light grade, 40mm bore 1200 mm long bent to shape at 120 degree, fixed on pole/building by providing MS clamp made out of flat iron 50x6 mm including bolts, nuts and washer of suitable size complete all as specified and directed. |