|
| 1 | Surface Dressing n.exc15 cm deep and getting out in Soft/loose soil complete all as directed. |
| 2 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 3 | Excavation in post hole (or similar holes) in hard/dense soil, each n.exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50m and making good complete all as specified and directed. |
| 4 | M & L for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation, filling and mass concrete complete all as specified and directed |
| 5 | M & Lmild steel angle iron as in fencing post, incl cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mess) incl all necessary drilling , bolting or reveting etc. conforming to Fe-290 Gde E-165complete all as specified and directed. |
| 6 | Supply only chain link MS galvanised fencing, any size or type as approved by GE complete all as specified and directed. |
| 7 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 8 | M & L for mild steel round bars 10mm dia and over cut to length bent to shape required and fixing as in stiffner for fencing complete all as specified and directed. |
| 9 | M & L for mild steel flat iron as inties , incl cutting tops to shape as directed, drilling holes, notching for wire etc. complete all as specified and directed. |
| 10 | M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of neck 11 to 15mm complete all as specified and directed. |
| 11 | M&L for preparation of new steel surfacesn exc 10 cm width or girth and applying two coats of synthetic enamel paint to steel surface over a coat of red oxide primer complete all as specified and directed. |
| 12 | M&L for preparation of new steel surfacesover 10 cm width or girth and applying two coats of synthetic enamel paint to steel surface over a coat of red oxide primer complete all as specified and directed. |
| 13 | M&L for preparation of old steel surfacesover 10 cm width or girth and applying two coats of synthetic enamel paint to steel surface over a coat of red oxide primer complete all as specified and directed. |
| 14 | M & L Hardcore of broken stone or boulders, gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 15 | M & L 100 mm thick PCC 1:3:6 type B2 (40 mm graded crushed stoneaggregate) as in subfloors finished even and faircomplete all as specified and as directed. |
| 16 | M & L PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concretecomplete all as specified and as directed.. |
| 17 | M&L for MS framed work such as grills, gratings etc with ends of bars shouldered or riveteted or foged into spikes, framed guard bars conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 18 | S&F Mild Steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade ST-240complete all as specified and as directed. |
| 19 | S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as in roof covering including fixing with self driving machine made screws with washers andfitting of same manufacture of approved profile, shape and colour complete all as specified and directed |
| 20 | S&F MS plate square cut or notched with riveted, welded or bolted joints conforming to Fe 410-W (Gde- E- 250) quality- A Fe- complete all as specified and directed. |
| 21 | S&F 1mm thickmild steel sheet as in eaves gutter, 125 mm dia, galvanised class 3, half round with rounded edges complete all as specified and directed |
| 22 | S&F wicket gate made of MS Frame using 40x40x6mm MS angle or 50x25 mm MS rectangular tube including vertical and horizontal bracing fitted with 2 Nos. MS hinges , MS Tower bolt , handle and locking arrangement. Gate shall be fabricated, welded, and finished withtwo coats of synthetic enamel paint over a coat of red oxide primerof approved colour. Gate Size (2.1m x 1.2 m) complete in all respect including materials , labour , fabrication , installation and finishing complete all as specified and directed. |
| 23 | S&F movable type badminton post made of heavy-duty MS steel pipe, duly powder-coated fitted with wheel for mobility and locking arrangement for stability during play, complete in all aspect incl fabrication , finishing complete all as specified abd directed. |
| 24 | S&F Synthetic turf infill system comprising the following :(i) Supply and application of natural quartz silica sand (grade 16/30 or 10/24 -sugar Size) at a rate of 2.5kg/sq.ft.(ii) Supply and application of rubber granules (crumb rubber) of 1-4 mm size at 500g/sq.ft. (iii) Adhesive bonding using Envirostik PU, Mapei Ultra Bond Turf-PU 2K, KDF, Fevicol SR998 or equivalent approved adhesive for seems and joints. (iv) Installation by expert labour and machinery using white grass of Bellin Turf or CC Grass, 14/10cm stitch rate, density of 8820 stitches/sqm and 50mm pile height for white line markings. (v) Application of white non-woven seaming tape at joints complete as per manufacturing specification and as directed. (Make: AV Sports and infrastructure/Altius Sports/Bellin turf/ Rayzon/Italgreen/Matrix turf/BWF approved) |
| 25 | Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified. |
| 26 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked,including 20 mm dia on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally includingaccessories includingmaking goodthe disturbed surfaces as per existingfor one light point controlled by one switch complete all asspecified anddirected by Engr-in-charge. |
| 27 | Description all as per Srl item No.27 here in before but for socket outlet point 5 Amp on same board. |
| 28 | Description all as per Srl item No.27 here in before but with 2.5 Sqmm cable for socket outletpoint 5 Amp on Independent board. |
| 29 | Description all as per serial item No 27 above but with 4 sqmm cablefor 3 pin 15 Amps switch socket outlet (Power point) complete all as specified. |
| 30 | Supply and fixing modular switch 1 way 6A module 230/250 volt , AC supply,ISI Marked, with cover plate complete all as specified and directed. |
| 31 | Supply and fixing modular sockets 6A 2/3 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with cover platecomplete all as specified and directed. |
| 32 | Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 33 | Supply and fixing modular switch 16A1 module 230/250 Volts,50 Hz , AC supply, ISI Marked with cover plate omplete all as specified and directed. |
| 34 | S & F Modular cover plate with frame & flush box of8 modules, complete all as specified and as directed. |
| 35 | S & F Modular cover plate with frame& flush box of 3 modules,complete all as specified and as directed. |
| 36 | S & F Modular cover plate with frame & flush box of 1 module,complete all as specified and as directed. |
| 37 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. |
| 38 | Supply and fixing Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC ,white/warm recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 39 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down unsv all as specified and as directed. |
| 40 | Supply and fixexhaust fan, steel body AC single Phase. 230V of size 300mmsweep with, blades, and frame and louvers complete all as specified and as directed. |
| 41 | Taking down fan exhaust fan of any description and size and deposit in MES store for safe custody all as specified and directed by Engr-in-Charge. |
| 42 | Refixingserviceable exhaust fanand connecting up including provision of cable from ceiling roseall as specified and directed. |
| 43 | Supply and fixin repair MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking downcomplete all as specified and directed. |
| 44 | Supply and fix RCBO with earth leakage, over load and short circuit proptection, DP, 240 Volts, 32 Amps, 30 mA senstivitycomplete all as specified and directed including taking down old one complete all as specified and as directedby Engr-in-charge. |
| 45 | Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed complete all as specified and as directed by Engr-in-Charge. |
| 46 | M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling inISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.NOTE: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit and cutting chases & making good shall be measured as one RM |
| 47 | M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia concealed on wall/ceiling inISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.NOTE: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit and cutting chases & making good shall be measured as one RM. |
| 48 | Material and labour for earthing in replacement complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.all as specified and directed by Engr-in-Charge. |