| 1 | M&L in repairs for non-skid ceramic jointless coloured tiles,7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm in floor etcset & jointed in neat cement slurry & pointed in white or coloured cement mixed with pigment to match, laid over and including 15mm thick screed layer in cement mortar 1:6,including dismantling of existing tiles, complete all as specified and directed. |
| 2 | M&L in repairs for non-skid ceramic jointless coloured tiles,7 to 8 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm in floor etcset & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match, laid over and including 15mm thick cement screed in cement mortar 1:6,including dismantling of existing tiles, complete all as specified and directed . |
| 3 | M&L in repairs for glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, etc., set and jointed in neat cement slurry and pointed with coloured cement to match, laid over and including 10mm thick rendering in cement mortar 1:4, including dismantling of existing tiles, complete all as specified & directed. |
| 4 | M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, bed plates, benching, levelling course in floor by maintaining required gradient / undulation etc slightly rounded or chamferred angles and throating, complte all as specified and directed. |
| 5 | S & F in repair Flush pipe (PVC) for squatt pattern closet including all joints and making good to the floor complete all as specified and directed. |
| 6 | S&F in repairs Vitreous china squatting pan of \"Orissa pattern\" of size 580mm x 440mm, white with CI ‘P’ or ‘S’ trap, front or back inlet and foot rests of any pattern (including fixing of flush pipe) and connecting etc. including provision of cement concrete bedding, complete all as specified and directed. |
| 7 | S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), white complete including fixing to trap including PVC seat and cover with hinging device for pedestal pan and connecting etc, complete all as specified and directed. |
| 8 | S&F in repairs PVC low level flushing cistern, valveless, syphonic action type, 10 litres capacity with inlet ball valve and handle with and including brackets and PVC bend pipe 60/90cm long etc, complete all as specified and directed. |
| 9 | S&F in reapirs Cast iron floor trap 75 mm bore dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4). Complete all as specified and directed. |
| 10 | S&F in reapirs Cast iron floor trap 100 mm bore dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone agregatecomplete all as specified and directed. |
| 11 | S&F in reapirs Cast iron gully/nahani trap 100 mm with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone agregatecomplete all as specified and directed. |
| 12 | Taking down old/broken cast iron pipes of any dia from existing lines fixed to walls with clamps or laid in trenches (Including necessary excavation). |
| 13 | S&F100mm dia sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints,fixed on walls with clamps. Complete all as specified and directed. NOTE: Clamps shall be measured and paid for separately. |
| 14 | S&F100 mm bore dia sand cast CI Bends with oval access door and jointed with neat cement paste. Complete all as specified and directed. |
| 15 | S&F75 mm bore dia sand cast CI Bends with oval access door and jointed with neat cement paste. Complete all as specified and directed. |
| 16 | M&L75 mm bore dia sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints,fixed on walls with clamps. Complete all as specified and directed. NOTE: Clamps shall be measured and paid for separately. |
| 17 | S&F 75 mm bore dia cast iron cowls complete all as specified and directed. |
| 18 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 100 mm dia CI pipe complete all as specified and directed. |
| 19 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 75 mm dia CI pipe complete all as specified and directed. |
| 20 | S&F GI pipe 25mm dia light grade (in short length) as spout pipe in sunken floor slab laid in slope & fixedto brick wall with PCC (1:2:4) type B-1, complete all as specified & directed. |
| 21 | Material and labour for rendering 15mm thick cement plaster on brick work or concrete surfaces in cement mortar (1:4)including WPC liquid mixed @ 200ml /50 kg of cement in sunken portion with proper slope towards outside and finishing surface even and smooth using extra cement including application of APP based polymeric membrane minimum weight 3Kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid over primed surface by forced application complete all as specified and as directed.Note : Water proofing compound shall be measured and paid for separately under respctive item. |
| 22 | M&L for 20mm thick cement plaster on concrete/brick tile surfaces of roof top in cement mortar 1:4 finished even and smooth using WPC liquid as per manufacturer instruction @ 200ml /50 kg of cement after sweeping/brushing clean & washing down with water incl taking down existing plaster complete all as specified & directed.Note : Water proofing compound shall be measured and paid for separately under respctive item. |
| 23 | M&L for 40mm thick brick tileslaid on roof top and joints grouted in flushin cement mortar 1:3 mixed with 5% of crude oil by weight of cement on roof, incl dismantling of existing all as specified. |
| 24 | Supply only integral water proofing compound. Complete all as specified and directed. |
| 25 | M&L for cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, sunken floor, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs incl demolition of existing concrete etc complete all as specified and directed |
| 26 | S&F in repairs 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid or fixed in trenches / floors/ walls, complete all as specified and directed. |
| 27 | S&F in repairs 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid or fixed in trenches / floors/ walls, complete all as specified and directed. |
| 28 | S&F in repairs 110mm bore PVC (SWR) bend, plain including jointing with solvent cement, complete all as specified and directed. |
| 29 | S&F in repairs 75mm bore PVC (SWR) bend, plain including jointing with solvent cement, complete all as specified and directed. |
| 30 | S&F in repairs PVC connection 15 mm bore with PTMT nuts of length 450 mm long complete all as specified and directed. |
| 31 | S&F in repairs syphonic action kit for 10 litres capacity PVC flushing cistern, complete all as specified and directed. |
| 32 | S&F in repairs Jet Spray (with 1.50 Mtr tube), fixed to EWC and angular stop cock/valve, complete all as specified and directed. |
| 33 | S&F in repairs 32/40mm CP waste coupling for sink complete all as per specified and directed. |
| 34 | S&F in repairs 32/40 mm dia, corrugated waste pipe suitable for WHBs/sinks including threaded PVC socket suitable for shank of waste coupling complete all as specified and directed. |
| 35 | S&F in repairs 32/40mm PTMT waste coupling for basin/sink (half or full threaded) complete all as per specified and directed. |
| 36 | Taking down cement plaster / wall tiles including backing etc from brick/stone walls / concrete surfaces including raking out joints,hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 37 | M&L for 15mm thick renderingin CM 1:6 overon brick work and concrete surfaces of wall, finished the surface even and smooth without using extra cement, including necessary scaffolding complete all as specified and directed. |
| 38 | M/L 15 mm thick rendering in two layers (5 mm thick in CM 1:4 over 10 mm thick in cement mortar 1:6) mixing with liquid WPC@ 200 ml/ 50Kg of cement on brick or concrete surfaces and finished even and smooth without using extra cement including necessary scaffolding all as specified and directedNote : Water proofing compound shall be measured and paid for separately under respctive item. |
| 39 | M&L for rendering 10 mm thick plaster on fair faces of brick work or concrete surface as in ceiling in cement mortar 1:3, finished even and smooth without using extra cement, including necessary scaffolding complete all as specified and directed. |
| 40 | M&L for preparation of newly plastered surfaces of walls by applying 1mm thick wall care putty making the surface even & smooth and applying two coats of oil bound distemper, complete all as specified and directed. |
| 41 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resisant priming paint, white or tinted, including curing before and after paint complete all as specified and directed. |
| 42 | M&L for preparation of newly plastered surfaces of walls, roof projection, ceiling, chajjas and applying three coats of white wash, complete all as specified and directed. |
| 43 | M&L in repair for brickwork using Fly Ash Bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6,including dismantling of existing brick work, complete all as specifiedand directed. |