| 1 | Cleaning drains of width 30cm to 45cm including removal of silt and rubbish within a distance of 150 m and removing grass &vegetations from the sides of drainsas directed. (ref per Observed data) |
| 2 | Cleaning storm water drains of width upto 1.50metre and depth up to 2.00 metres including removal of silt and vegetationrubbish cutting and removing grass vegetations from the sides of drains and disposal of rubbish within a distance of 150 metresetc., complete. Ref observed data |
| 3 | Taking out RCC cover slabs (150 mm thick) of drain care fully without any damage and keeping the same in position after cleaning the drain etc complete.(Ref per Observed data) |
| 4 | Cleaning verandah eve gutters and disposal of rubbish to the dumping ground including tightening clamps etc complete.(Ref per Observed data) |
| 5 | Supplying roofing compound and bitumen washer/sylicon for closing leakages from bolt holes of AC / pre-coated profile sheets, replacing damaged bitumen washers, pasting and covering with roofing compound tightening of J bolts and nuts etc. complete. (Rate shall inclussive of cost of biumen washers,roofing compound, labour charges for scaffolding etc.) Ref observed data |
| 6 | Supplying and pasting tarfelt sheet one layer of approved brand (STP or equivalant ) over broken AC sheet roofs/GI sheets, ridges,gable wall joints,valley gutters,sides of parapet etc after cleaning the surface to which tarfelt is to be pasted and applying bitumastic roofing compound (Shalibond CS or equivalant.the rate shall includelabour charges,scaffolding complete as directed by engineer in charge.The work is to be carried out at roof of godown at a height upto 12 metres from ground level after observing all safety norms.)(Ref per Observed data) |
| 7 | Reparing/Servicing rolling shutters such as removal of top covers tightening/ loosening the springs adjusting the dislocation of parts if any and applying greese to the springs side guides ( 0.40 kg greese/ shutter) after cleaning and refixing the cover in position etc as directed by engineer in charge.(Ref per Observed data) |
| 8 | Providing and fixing 27.5cm long wire spring grade no:2 for rolling shutters of approved brand and specification. (Ref per Observed data) |
| 9 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) (Item no 15.2.1 of DSR 2023) |
| 10 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge-Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) item no 15.2.2 |
| 11 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete DSR 2023 Item No 10.1 |
| 12 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) Item No.4.1.8 ofDSR 2023 |
| 13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 2023 item no 5.1.2 |
| 14 | Centering and shuttering including strutting, propping etc. and removalof form work for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.(Item No 5.9.2 of DSR 2023) |
| 15 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) DSR 2023 Item 13.16.1 |
| 16 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR 2023 Item No. 5.12 |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.(Item No 5.22.6 of DSR 2023) |
| 18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. Ref DSR 2023 Item No.11.41.2 |
| 19 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment( Item No. 11.20.4 of DSR 2023) |
| 20 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make, in all colours , shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, rsiers of steps and dados, over 12 mm thick bed of cement mortar (1 cement, 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing the joints with white cement and matching pigment etc. complete Item No 8.31 of DSR 2023 |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge External work:20 mm nominal dia Pipes (Ref DSR 2023 item No.18.9.2) |
| 22 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid(DSR 2023 Item No : 17.2.1) |
| 23 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In- Charge Ref DSR 2023 Item No.14.75 |
| 24 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) (Item No 4.2.3 of DSR 2023) |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron)(Item No.21.1.1.2 of DSR 2023) |
| 26 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)(Item No.21.3.1 of DSR 2023) |
| 27 | Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames DSR 2023 item No 9.122.1 |
| 28 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.(Item No.9.121 of DSR 2023) |
| 29 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Ref DSR 2023Item No.15.60 |
| 30 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. Code Description Unit Rate No. SUB HEAD : 8.0 CLADDING WORK 163 (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till thehanding over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.(item No.8.32 of DSR2023) |
| 31 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats (Item No.13.51.2 of DSR 2023) |