| Sl. No. | Item Description |
| 1 | STABILITY CERTIFICATION OF BALANCE OFFICES AT EAST WING ON FIRST FLOOR OF TECHNICAL BUILDING AS PER RCF\"SPROFORMA DUE TO CHANGE IN LOADING CONDITIONS & SUBMISSION OF AS BUILD DRAWINGS AFTER COMPLETION OF CONSTRUCTION, INCLLUDING NECESSARY FORTNIGHT SITE VISITS DURING EXECUTION. |
| 2 | DESIGN AND PREPARATION OF PLAN/LAYOUT OFINTERIOR RENOVATION OF EAST WINGFOR CIVIL INTERIOR WORKS INCLUDING CABIN SIZES, PARTITIONS, ELECTRICAL,NETWORKING LAYOUT IN CONSULTATION WITH RCF ENGINEER-IN-CHARGE WITH MAXIMUM THREE REVISIONS (DUE TO INCORPORATION OF RCF INPUTS/COMMENTS AFTER SUBMISSION OF PRELIMINARY DRAWINGS). |
| 3 | DISMANTLING EXISTING FLOORING, SKIRTING, TILES, WALL CLADDED MARBLE,MEMBRANE ETC., INCLUDING DISPOSAL OF MATERIALS DEBRIS WITHIN RCF FACTORY PREMISES WITHIN A LEAD OF3 KM, COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE. |
| 4 | REMOVING EXISTING LOOSE CEMENT/PLASTER OF ANY FINISH FROM THE WALL, COMPLETE INCLUDING PREPARING SURFACE, NECESSARY SCAFFOLDING, CLEANING ETC. COMPLETEINCLUDING DISPOSAL OF MATERIALS DEBRIS WITHIN RCF FACTORY PREMISES WITHIN A LEAD OF3 KM.,FOR ALL LOADS INCLUDING ALL LIFTS INVOLVED COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE. |
| 5 | DEMOLISHING EXISTING BRICK / STONE MASONRY WORK INCEMENT MORTAR (ANY PROPORTION AT ANYHEIGHTS / DEPTHS INCLUDING STACKING OFSERVICEABLE MATERIALS AND DISPOSAL OFUNSERVICEABLE WITHIN A LEAD OF 3 KM.,,FOR ALL LOADS INCLUDING ALL LIFTS INVOLVED COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE. |
| 6 | PROVIDING & CHIPPING GROOVES IN WALLS,CEILING OF REQUIRED SIZE & SHAPE FOR CONCEALING OF ELECTRICAL WIRING & MAKING GOOD THE DAMAGED PORTION WITH PMM/PUTTY AS PER EICWITH NECESSARY SCAFFOLDING ETC. COMPLETE INCLUDING DISPOSAL OF DEBRIS ,FOR ALL LOADS INCLUDING ALL LIFTS INVOLVED AS DIRECTED BY EIC. |
| 7 | REMOVING EXISTING DOORS, WINDOWS WITH FRAMES AND SHUTTERS ETC. COMPLETE. (DISMANTLING, DEMOLISHING, CUTTING, BREAKING, REMOVING & CLEANING EXISTING ITEM CAREFULLY AND STACKING THE MATERIAL AT SITE OR AS INSTRUCTED INCLUDING CARTING AWAY DEBRIS FROM TECHNICAL BLDG. PREMISES WITH PRIOR APPROVAL & PERMISSIONS OF RCF. THE DEMOLISHED / STACKED MATERIAL SHALL BE PROPERTY OF THE CONTRACTOR & SHALL BE RESPONSIBILITY TO TAKE IT OUTSIDE RCF PREMISES). |
| 8 | REMOVING EXISTING FALSE CEILING WITH FRAMING ETC. COMPLETE. (DISMANTLING, DEMOLISHING, CUTTING, BREAKING, REMOVING & CLEANING EXISTING ITEM CAREFULLY AND STACKING THE MATERIAL AT SITE OR AS INSTRUCTED INCLUDING CARTING AWAY DEBRIS FROM TECHNICAL BLDG. PREMISES WITH PRIOR APPROVAL & PERMISSIONS OF RCF. THE DEMOLISHED / STACKED MATERIAL SHALL BE PROPERTY OF THE CONTRACTOR & SHALL BE RESPOSIBILITY TO TAKE IT OUTSIDE RCF PREMISES). |
| 9 | REMOVING EXISTING ALUMINUM/WOODEN PARTITIONS WITH FRAMING ETC. COMPLETE. (DISMANTLING, DEMOLISHING, CUTTING, BREAKING, REMOVING & CLEANING EXISTING ITEM CAREFULLY AND STACKING THE MATERIAL AT SITE OR AS INSTRUCTED INCLUDING CARTING AWAY DEBRIS FROM TECHNICAL. BLDG. PREMISES WITH PRIOR APPROVAL & PERMISSIONS OF RCF.) |
| 10 | PROVIDING LIGHT WEIGHT AUTOCLAVED CONCRETE BLOCK MASONRY OF APPROVED BLOCK SIZE USING PREMIXED AND READY TO USE COMPATIBLE MORTAR AS APPROVED BY EIC. |
| 11 | PROVIDING AND APPLYING POLYMER MODIFIED READY MIX CEMENT MORTAR (PMM) FOR PLASTERING/ MICRO CONCRETE (PMC) OF ANY THICKNESS AS PER SITE REQUIREMENT OF APPROVED BRAND INCLUDING CURING ETC. AS PER MANUFACTURER\"S SPECIFICATIONS OR AS PER INSTRUCTIONS OF ENGINEER IN-CHARGE (THE ITEMS SHALL BE PAID ON ACTUAL CONSUMPTION OF READY MIX QUANTITY ONLY).THE RATE SHALL BE INCLUSIVE OF SURFACE PREPARATION BEFORE APPLICATION AS PER THE MANUFACTURER\"S SPECIFICATIONS INCLUDING NECESSARY FORMWORK, APPLYING RUST CONVERTER, RUST INHIBITOR COAT, BOND COAT ETC. AS DIRECTED BY EIC AT ALL HEIGHTS INCLUDING M.S. PIPE SCAFFOLDING ETC. COMPLETE. THE ITEM SHALL BE PAID FOR PLASTER THICKNESS OF 10MM TO 15MM. |
| 12 | PROVIDING AT ALL HEIGHTS 12 MM THICK INTERNAL CEMENT PLASTERON BRICKWORK,EXPOSED SURFACES OFRCCLINTELS,BEAMS,ETC., COMPLETE IN ALL RESPECTS ANDAS DIRECTED WITH CEMENT PLASTER MIX : 1:4 (1CEMENT : 4 KHARSALIA SAND) INCLUDING NECESSARY SCAFFOLDING, CURING ETC. COMPLETE. |
| 13 | PROVIDING AND APPLYING 8 TO 10 MM THICK POP WALL PUNNING AS REQUIRED TO INTERNAL WALLS INCLUDING SCRAPPING OF EXISTING PAINT OR ON NEW SURFACES WITH LINE & LEVEL TO MAKE SURFACE SMOOTH. |
| 14 | PROVIDING AND FIXING 40MM DIAMETER AND 1.5MM THICK STAINLESS STEEL RAILING IN S.S.304 GRADE INCLUDING FABRICATING, FIXTURES, ERECTING, NECESSARY WELDING, GRIDING, FINISHING, BUFFING TO STAINLESS STEEL PIPE ETC. COMPLETEWITH NECESSARY STAINLESS STEEL NUTS AND BOLTS COMPLETE, I/C FIXING THE RAILING WITH NECESSARY ACCESSORIES AND STAINLESS STEEL DASH FASTENERS, STAINLESS STEEL BOLTS, ETC(SAMPLE DESIGN SHALL BE APPROVED) |
| 15 | PROVIDING AND PAINTING SURFACES WITH TWO COATS OF COLD BITUMEN PAINT OF APPROVED QUALITY ON AND AROUND TOILET AREAS, COMPLETEIN ALL RESPECTS AS PER DIRECTION OF ENGINEER-IN-CHARGE |
| 16 | PROVIDING & APPLYING ASIAN PAINTS / NEROLAC / BERGER LUSTRE PAINT AS REQUIRED TO INTERNAL WALLS & CEILING AS PER MANUFACTURER\"S SPECIFICATIONS WHICH INCLUDE SCRAPPING THE WALL, APPLYING 1 COAT OF PRIMER & 2/3 COATS OF PUTTI, SCRAPPING THE WALL WITH WATER PAPER AND APPLYING 2 COATS OF LUSTRE PAINT. |
| 17 | PROVIDING AND LAYING VITRIFIED TILES OF SOMANY/RAK/KAJARIA/NITCO/ASIAN OR EQUIVALENT MAKE HAVING SIZE BETWEEN 800 TO 1200 MM X 800 MM TO 1200 MM (THICKNESS TO BE SPECIFIED BY MANUFACTURER) AND CONFIRMING TO IS 15622-2006 OF APPROVED MAKE, SHADE AND PATTERN FOR FLOORING/SKIRTING IN REQUIRED POSITION LAID ON A BED OF 1:4 CEMENT MORTAR INCLUDING NEAT CEMENT FLOAT, FILLING JOINTS, CURING AND CLEANING ETC. COMPLETE.APPROVAL FOR SIZE OF TILE TO BE PRIOR APPROVED BY RCF. |
| 18 | PROVIDING & FIXING BLACK GRANITE STONE APPROX. 18 TO 20 MM THICK FOR DOOR & WINDOW SILLS/JAMBS/FRAME/RISER/TREAD ETC. IN SINGLE/DOUBLE STEM IN 1:6 INCLUDING NOSING SHARP EDGES WHEREVER NECESSARY AS DIRECTED BY EIC. |
| 19 | PROVIDING, SUPPLING & FIXING 12MM THICK SINGLE LEAF TOUGHNED GLASS DOOR OF SAINT GOBAIN/MODI/ASAI MAKE WITH 6/8\" AS DIRECTED POLISHED WOODEN PATTI AT TOP & BOTTOM. THE GLASS DOOR SHALL BE MADE OPERATABLE ON FLOOR SPING OF ENOX/OMEGA MAKE & CAPABLE TO TAKING ITS LOAD WITH OTHER PATCH FITTINGS SUCH AS LOCK, BOTTON & TOP PATCH, PIVOT, 2\" HIGH SS FINISH HANDLEON BOTH SIDES, PUSH/PULL INDICATOR, ETC. THE DOOR MAY ALSO HAVE SS FINISH BRASS MAKE STOPPER FIXED ON TOP IF REQUIRED. |
| 20 | PROVIDING & FIXING 30 MM THICK SINGLE LEAF SOLID CORE FLUSH DOOR WITH APPROVED SHADE LAMINATE (1 MM) FINISH INCLUDING NECESSARY HARDWARE, FITTINGS & FIXTURES LIKE CYLINDRICAL DOOR LOCK, CHROMIUM PLATED HANDLES ON BOTH SIDES, PVC DOOR STOPPER, BRASS MAKE ISI MARKED HYDRAULIC DOOR CLOSER, POLISH TO ALL EXPOSED SURFACES, EDGES, ETC. COMPLETE AS PER DETAIL DRAWING. IF REQUIRED, THE DOOR SHALL HAVE 2\" X 3\" (OR AS DIRECTED) 5 MM THK. PLAIN GLASS AT TOP FIXED WITH BEADING PATTI ALL AS SPECIFIED AND AS DIRECTED. |
| 21 | PROVIDING & FIXING 30 MM THICK SINGLE LEAF SOLID CORE FLUSH DOOR WITH APPROVED SHADE LAMINATE (1 MM) FINISH INCLUDING NECESSARY HARDWARE, FITTINGS & FIXTURES LIKE CYLINDRICAL DOOR LOCK, CHROMIUM PLATED HANDLES ON BOTH SIDES, PVC DOOR STOPPER, BRASS MAKE ISI MARKED HYDRAULIC DOOR CLOSER, POLISH TO ALL EXPOSED SURFACES, EDGES, ETC. COMPLETE AS PER DETAIL DRAWING. IF REQUIRED, THE DOOR SHALL HAVE 2\" X 3\" (OR AS DIRECTED) 5 MM THK. PLAIN GLASS AT TOP FIXED WITH BEADING PATTI ALL AS SPECIFIED AND AS DIRECTED. |
| 22 | SUPPLYING AND PASTING GARWARE OR EQUIVALENT POLYESTER FILM, OF APPROVED COLOUR & REFLECTIVE RANGE OVER GLASS PANES AT ALL ELEVATION INCLUDING PREPARATION OF GLASS, SPRAYING OF CHEMICAL OVER GLASS, PRESSING OF FILM BY WIPER WITHOUT ANY BUBBLES DONE BY A PROFESSIONAL AGENCY COMPLETE TO THE SATISFACTION OF ENGINEER-IN-CHARGE. |
| 23 | FULL HEIGHT PARTITION: PROVIDING & FIXING A NON-LOAD BEARING, 74MM THICK METAL FRAMED PARTITION WITH PARTLY GLAZED 8MM THICK CLEAR GLASS WITH BTC BEADING PATTIES FINISHED WITH POLISH/PAINT AS PER MATCHING SHADE LAMINATE AS PER DESIGN/INSTRUCTIONS. RATE IS INCLUDING EXTRA FRAMEWORK FOR FIXING OF GLASS AS DIRECTED BY EIC OR WITH 1HOUR FIRE RATING AND SOUND INSULATION OF 41 DECIBEL.MAIN SYSTEM:74MM THICK METAL STUD PARTITION COMPRISING OF A 100MM WIDE X 12MMTHICK HILUX BOARD OR EQUIVALENT FILLETS (STRIPS) SCREW FIXED WITH 25MM SELF TAPPING SCREWS AT 200MM CENTRES TO BOTH SIDES OF A COMPOSITE FRAMEWORK WHICH INCLUDES A48MM STUD OF 0.55MM THICK AND HAVING TWO UNEQUAL FLANGES OF 48AND 50MM EACHPLACED AT 610MM CENTER TO CENTER IN 50MM FLOOR AND CEILING CHANNELWITH TWO EQUAL FLANGES OF 32MM EACH FIXED TO FLOOR AND CEILING AT 600MM CENTER, WITH THE HELP OF NYLON SLEEVES AND WOOD SCREWS. 12MM THICK HILUX BOARDS OR EQUIVALENT ARE THEN SCREW FIXED BY 35MM LONG SELF DRILLING AND TAPPING SCREWS HAVING PHILLIPS HEAD WITH UNDER HEAD CUTTER, TO THE STUDS AND CHANNELS ON BOTH SIDES OF THE FRAME WORK. THE BOARD’S JOINTS ARE TO BE STAGGERED TO AVOID THROUGH PASSAGE.INSULATION: 50MM THICK (DENSITY-48KG/M3) MINERAL WOOLOR ROCKWOOL AS DIRECTED IS TO BE PLACED IN THE CAVITY OF THE PARTITION.JOINTING AND FINISHING:FINALLY EDGES OF THE FACING BOARDS ARE TO BE JOINTED AND FINISHED SO AS TO HAVE A SEAMLESS FINISH WHICH INCLUDES FILLING AND FINISHING WITH SPECIALLY FORMULATED JOINTING COMPOUND AND SELF-ADHESIVE FIBRE TAPE. CEMENT PRIMER (OIL BASED) TO BE PROVIDED ON ENTIRE SURFACE BEFORE PUTTY/ PAINTING. NOTE: A HORIZONTAL BRACING CHANNEL IS TO BE PROVIDED IF THE PARTITION HEIGHT EXCEEDS THE BOARD LENGTH TO PROVIDE EDGE SUPPORT TO THE BOARD. THE NECESSARY OPENING SHALL BE PROVIDED IN THE PARTITION FOR ELECTRICAL/TELEPHONE CONDUITS & OUTLETS AS PER DESIGN/INSTRUCTIONS. |
| 24 | LOW HEIGHT PARTITION FOR CUBICALS :PROVIDING & FIXINGSAME AS FULL HEIGHT PARTITION ITEM WITH PARTITION PROVIDED WITH 3-1/2\" WIDE X1\" THK MOULDING PATTI IN B.T.C ON EDGES AND THE SAME SHALL BE FINISHED WITH MATCHINGPOLISH WITH 10MM THK EDGE POLISHED CLEAR GLASS FIXED OVER WITHIN BEADING PATTI 1\" DEEP AS DIRECTED. (RATE IS EXCLUDING GLASS) |
| 25 | PROVIDING AND FIXING 1.5 MM THICK LAMINATES (OF MAKE GREENLAM, CENTURY, MERINO OR EQUIVALENT) TO FULL HEIGHT/LOW HEIGHT PARTITIONS AND ANY OTHER LOCATIONS WITH FINISH AS DIRECTED BY EIC. |
| 26 | FULL HEIGHT CLADDING: PROVIDING & FIXING A NON-LOAD BEARING, 37MM THICK METAL FRAMED CLADDING ON WALL COMPRISING OF 12MM THICK HILUX BOARD OR EQUIVALENT FILLETS (STRIPS) SCREW FIXED WITH 25MM SELF TAPPING SCREWS AT 200MM CENTRES OF A FRAMEWORK WHICH INCLUDES CHANNEL WITH TWO EQUAL FLANGES OF 32MM EACH FIXED VERTICALLY ON WALL AT 600MM CENTER, WITH THE HELP OF NYLON SLEEVES AND WOOD SCREWS. 12MM THICK HILUX BOARDS OR EQUIVALENT ARE THEN SCREW FIXED BY 35MM LONG SELF DRILLING AND TAPPING SCREWS HAVING PHILLIPS HEAD WITH UNDER HEAD CUTTER, TO THE STUDS AND CHANNELS ON SINGLE SIDE OF THE FRAME WORK. THE BOARD’S JOINTS ARE TO BE STAGGERED TO AVOID THROUGH PASSAGE. JOINTING AND FINISHING: FINALLY EDGES OF THE FACING BOARDS ARE TO BE JOINTED AND FINISHED SO AS TO HAVE A SEAMLESS FINISH WHICH INCLUDES FILLING AND FINISHING WITH SPECIALLY FORMULATED JOINTING COMPOUND AND SELF-ADHESIVE FIBRE TAPE. CEMENT PRIMER (OIL BASED) TO BE PROVIDED ON ENTIRE SURFACE BEFORE PUTTY/ PAINTING.NOTE: THE NECESSARY OPENING SHALL BE PROVIDED IN THE PARTITION FOR ELECTRICAL/TELEPHONE CONDUITS & OUTLETS AS PER DESIGN/INSTRUCTIONS. |
| 27 | FULL HEIGHT CLADDING: PROVIDING & FIXING A NON-LOAD BEARING, 12MM THICK HILUX BOARD OR EQUIVALENT CLADDING DIRECTLY ON PLASTERED WALL SCREW FIXED WITH 25/35MM SELF DRILLING AND TAPPING SCREWS HAVING PHILLIPS HEAD WITH UNDER HEAD CUTTER. THE BOARD’S JOINTS ARE TO BE STAGGERED TO AVOID THROUGH PASSAGE.JOINTING AND FINISHING: FINALLY EDGES OF THE FACING BOARDS ARE TO BE JOINTED AND FINISHED SO AS TO HAVE A SEAMLESS FINISH WHICH INCLUDES FILLING AND FINISHING WITH SPECIALLY FORMULATED JOINTING COMPOUND AND SELF-ADHESIVE FIBRE TAPE. CEMENT PRIMER (OIL BASED) TO BE PROVIDED ON ENTIRE SURFACE BEFORE PUTTY/ PAINTING.NOTE: THE NECESSARY OPENING SHALL BE PROVIDED IN THE WALL FOR ELECTRICAL/TELEPHONE CONDUITS & OUTLETS AS PER DESIGN/INSTRUCTIONS. |
| 28 | REMOVINGWASH BASIN / WC URINAL FITTINGS INCLUDING STACKING THE MATERIALS AS DIRECTED WITH ALL LEADS, LIFT, COMPLETE. |
| 29 | DISMANTLING / REMOVING OF CONCRETE BY CHISELLING, WEDGING, ETC.INCLUDING CUTTING REINFORCEMENT, STACKING THE SERVICEABLE MATERIALS AND DEBRIS SEPARATELY OR SPREADING THE DEBRIS AND DEPOSITING METAL SCRAP IN SCRAP YARD WITHIN FACTORY AREA AS DIRECTED ETC. COMPLETE. (447+184.08 (1.5 KM))*1.25 |
| 30 | PROVIDING & FIXING OF ALUMINUM LAY IN MICRO PERFORATED OF ARMSTRONG OR EQUIVALENT MAKE (1.8MM DIAMETER-20% OPEN AREA) METAL CEILING CONSISTING OF 600X600MM LAY IN TILES IN 0.7 MM THICK ALUMINUM PRE COATED TO GLOBAL WHITE COLOR WITH ACOUSTICAL FLEECE HOT PRESSED ON THE BACK OF THE PERFORATED TILE & 50 MM THK. RESIN BONDED GLASS WOOL BACKING TO BE LAID ON ARMSTRONG GRID SYSTEMS WITH 24MM WIDE T - SECTION FLANGES COLOR WHITE HAVING ROTARY STITCHING ON THE MAIN RUNNER, 1200 MM & 600 MM CROSS TEES. THE TILES WOULD HAVE NRC OF 0.50, FIRE PERFORMANCE OF CLASS A2-S1.D0 AS PER EN13501 STANDARD IN MODULE SIZE OF 600 X 600MM, SUITABLE FOR GREEN BUILDING APPLICATION, WITH RECYCLED CONTENT OF 50%. THE TILE SHALL BE LAID ON 24 MM WIDE T - SECTION FLANGES COLOUR WHITE HAVING ROTARY STITCHING ON ALL T SECTIONS I.E. THE MAIN RUNNER, 1200 MM & 600 MM CROSS TEES WITH A WEB HEIGHT OF 38MM AND A LOAD CARRYING CAPACITY OF 15.34KGS/M2& PULL OUT STRENGTH OF 100KGS. THE T SECTIONS HAVE A GALVANIZING OF 90 GRAMS PER M2AND NEED TO BE INSTALLED WITH SUSPENSION SYSTEM. |
| 31 | PROVIDING AND FIXING PREMIUM QUALITY VITRIFIEDTILES OF SOMANY / RAK / KAJARIA / NITCO / JHONSON MAKE OF APPROVED SHADE & DESIGN IN DIGITAL SERIES OF JHONSON MAKE OF SIZE 1\"X2\" (300 MM X 600 MM) / 18\"X12\" FOR DADO IN REQUIRED POSITION IN PERFECT LINE & LEVEL OVER CEMENT MORTAR 1:4 INCLDUING CEMENT FLOAT, FILLING JOINT WITH WHITE/COLOUR CEMENT SLURRY, CLEANING, CURING, ETC. COMPLETE. |
| 32 | PROVIDING AND FIXING WALL HUNG / FLOOR MOUNTED EUROPEAN TYPE WHITE GLAZED EARTHENWARE WATER CLOSET PAN OF PARRYWARE/HINDWARE WITH ITS FITTINGS, 4\" DIA. PVC BEND PIPE, M.S.BRACKETS, SOFT CLOSER SEAT, GROHE MAKE PNEUMATIC FLUSH TANK, 2 WAY BIB COCK WITH HEALTH FAUSCET, ETC.WITH CHROMIUM PLATED BRASS HINGES AND RUBBER BUFFERS INCLUDING UPVC AND VENT PIPE UP TO THE OUTSIDE FACE OF WALL WITH FITTINGS PIPE, BRACKETS FOR FIXING CISTERN 32 MM DIA. UPVC FLUSH PIPE WITH FITTINGS AND CLAMPS, 20 MM DIA. UPVC OVERFLOW PIPE, MOSQUITO PROOF COUPLINGS, WITH WATER JET AND FITTING INCLUDING CUTTING AND MAKING GROOVE TO THE WALLS AND FLOORS TESTING ETC. COMPLETE SO AS TO MAKE IT FIT TO USE. |
| 33 | PROVIDING & FIXING COUNTER TOP WASH BASIN OF PARRYWARE/HINDWARE/ JAQUARMAKE & OF APPROVED COLOR AND SIZE WITH ITS FITTINGS INCLUDING BRASS WASTE COUPLING, SS BOTTLE TRAP, CP PILLAR TAP (JAQUAR/PLUMBER MAKE), CONNECTOR FOR ANGEL COCK, CP HEAVY QUALITY ANGLE STOP COCK, ETC. COMPLETE SO AS TO MAKE IT FIT TO USE. |
| 34 | PROVIDING AND FIXING 10 CM C.I. NAHANI TRAP INCLUDING C.I. GRATING BEND AND PIECE OF C.I. PIPE UP TO OUTSIDE FACE OF THE WALL COMPLETE. |
| 35 | PROVIDING AND FIXING 110 MM DIA STABILISER PIPE/PVC SOIL VENT/WASTE PIPE AND WITH NECESSARY FIXTURES AND FITTINGS SUCH AS BENDS, TEES, SINGLE JUNCTIONS, SLOTTED VENT, CLAMPS, ETC. COMPLETE. |
| 36 | PROVIDING AND FIXING SUPERIOR TYPE BELGIUM MIRROR ETC. COMPLETE AS DIRECTED APPROVED BY EIC. |
| 37 | PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE CPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOFINCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 15 MM DIA. |
| 38 | PROVIDING & FIXING CONCEALED / CLAMPED ON WALLASTRAL/FINOLEX OR EQUIVALENT MAKE CPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOFINCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 20 MM DIA. |
| 39 | PROVIDING AND LAYING 1:2:4 (1 CEMENT: 2 FINE AGGREGATE :4 GRADED STONE AGGREGATE20 MM NOMINAL SIZE).PLAIN CEMENTCONCRETE,MANUAL / MACHINE MIXEDANDMANUAL / MECHANICALLY VIBRATED IN FOUNDATIONS,PLINTH,UNDER FLOORS,SCREEDINGAS PER EICETC.,INCLUDINGALL NECESSARYCOSTOFCENTRINGAND SHUTTERING & CURING ETC. COMPLETE : |
| 40 | PROVIDING SUPPLYING, DE-RUSTING BY SHOT BLASTINGFABRICATING, ERECTING, HOISTING ANDFIXING IN POSITION STRUCTURAL STEEL WORKIN ROLLED STEEL JOINTS, CHANNELS, ANGLESTEES, FLATS, PLATES, LATTICE MEMBERSBUILT UP / COMPOUND SECTIONS INCOLUMNS, PORTALS, GIRDERS, BEAMS,BRACINGS, TRUSSES, PURLINS, RAFTERS,STAIRCASE, STEPS, HAND-RAILINGS,WALKWAY, CAT LADDER WITH CAGES, TOEPLATES, SIDE WALLING, TRESTLES,CONVEYOR GANTRIES ETC. INCLUDINGGUSSET PLATES, ETC.,INCLUDING SITE AND SHOP FASTENERS,RIVETING, BOLTING, WELDING AT SHOP ORWORK SITE AT ALL HEIGHTS INCLUDING SCAFFOLDING WITH MS PIPE ETC.SURFACE PREPARATION SURFACE PREPARATION FOR ALL THE ITEMS TO BE PAINTED AFTER SLAG BLASTING.AIR USED FOR SLAG BLASTING MUST BE DRY AND OIL FREE.SLAG USED FOR BLASTING MUST BE OF GOOD QUALITY FOR ACHIEVING SURFACE FINISH AS DIRECTED BY EIC.SLAG BLASTED SURFACE MUST BE COATED WITH PRIMER WITHIN 2 HOURS.PAINTING SYSTEM TO BE USED AS INDICATED BELOW. I. P1-ONE COAT OF ETHYL SILICATE INORGANIC ZINC PRIMER HAVING DFT OF 70 MICRONS PER COAT.II .IP1ONE COAT OF EPOXY MIO HAVING DFT OF 70 MICRONS PER COAT.III.FP1 ONE COAT OF FINISH EPOXY PAINT USING TWO PACK POLYAMIDE CURED EPOXY HAVING DFT OF 40 MICRONS PER COAT.IV.FP2 - ONE COAT OF ALIPHATIC ACRYLIC POLYURETHANE PAINT HAVING DFT OF 40 MICRONS PER COAT. ETC COMPLETE AS DIRECTED BY EIC. (ALL MATERIALSUPPLY IS IN CONTRACTOR’S SCOPEINCLUDING PAINTS (AS PER TS). (ONLY TATA/SAIL/JINDAL/RINL MAKE STEEL TO BE USED) . |
| 41 | FABRICATING STRUCTURAL STEEL WORK IN ROLLED SECTIONS, FIXED WITH CONNECTING PLATES OR ANGLE CLEATS IN MAIN AND CROSS BEAMS, HIP AND JACK RAFTERS, PURLINS CONNECTING TO TRUSS MEMBERS, JOISTS, CHANNELS, ANGLES, TEES GRATINGS, RAILING, GI PIPE, GRATTING ETC. AS PER DETAILED DESIGNS AND DRAWING OR AS DIRECTED INCLUDING CUTTING, FABRICATING, HOISTING, ERECTING, FIXING IN POSITION, MAKING RIVETED / BOLTED / WELDED CONNECTIONS AND ONE COAT OF ANTICORROSIVE PAINT AND OVER IT TWO COATS OF EPOXY PAINTING COMPLETE (RCF WILL SUPPLY ONLY STRUCTURAL STEEL AND CONSUMABLE GASES IF AVAILABLE FREE OF COST AT RCF STORES CONTRACTOR HAS TO SHIFT THE MATERIAL FROM STORES TO SITE AT OWN COST.) |
| 42 | PROVIDING AND FIXING IN POSITION STEEL BARS REINFORCEMENT OFVARIOUS DIAMETERS FOR R.C.C. PILE, PILE CAPS,FOOTINGS,RAFT,RETAINING WALL,SHEAR WALL, LIFT WALL,FOUNDATIONS, SLABS, BEAMS, COLUMNS, CANOPIES,STAIRCASES, NEWELS, CHAJJAS, LINTELS, PARDIES,COPING, FINS, ARCHES, ETC. AS PER DETAILED DESIGNS,DRAWINGS AND BAR BENDING SCHEDULES,INCLUDING STRAIGHTENING,CUTTING, BENDING, HOOKING THE BARS, BINDING WITH WIRES OR TACK WELDING, SUPPORTING AS REQUIRED ETC. INCLUDINGBINDINGWITH 18 SWGANNEALEDWIRE, THERMO-MECHANICALLY TREATED STEEL BARS HYSD/TMT/STEEL REINFORCEMENTS AS PER IS: 1786 INCLUDINGALLNECESSARY HANDLING AT ALL HEIGHTS AND DEPTHS COMPLETE INALL RESPECTSANDAS PER DIRECTION OF THE ENGINEER-IN CHARGE (FE 500D OF ONLY TATA/SAIL/JINDAL/RINLMAKE STEEL TO BE USED) |
| 43 | PROVIDING AND LAYING REINFORCEDCEMENT CONCRETE OF GRADE M - 25(USING 20 MM, NOMINAL GAUGE GRADEDSTONE AGGREGATE) MACHINE MIXED ANDMECHANICALLY VIBRATED AND FINISHED TOA FAIR FACEINCLUDING THE COST OFCENTERING, SHUTTERING ANDREINFORCEMENT IN FOUNDATION,SUPERSTRUCTURE ANDPLINTH FOR: RAFTS, FOOTINGS, BASES OFCOLUMNS, PEDESTALS, BEAMS, WALLS,COLUMNS, MACHINE AND EQUIPMENTFOUNDATIONS, PILE CAPS, BOX SECTIONS,PIPE SUPPORTS, CABLE TRENCH, DRAINSETC., COMPLETE IN ALL RESPECTS AS PERDIRECTION OF ENGINEER -IN- CHARGE .THE MINIMUM CEMENT CONTENT IRRESPECTIVE OF DESIGN MIX SHOULD BE 350 KG/CUM. |
| 44 | PROVIDING & APPLYING TWO OR MORE COATS OF 100% EXTERIOR GRADE ACRYLIC EMULSION PAINT(WEATHERSHIELD OR APEX) COLOUR /SHADE AS PER APPROVED BRAND AND MAKE TO EXTERIOR OLD/ NEW RCC/MASONRY SURFACESAFTER ONE COAT OF COMPATIBLE WATERPROOF PRIMER, NECESSARY CLEANING ETC. COMPLETE AS DIRECTED BY EIC. |
| 45 | PROVIDING AT ALL HEIGHTS 20 MM THICK CEMENT PLASTERON SINGLE OR HALF BRICK WALLS IN ALL POSITION INCLUDING BASE COAT OF 12 MM THICK IN CEMENT MORTAR 1:4(1CEMENT:4 READY MIXED GRADED PLASTER SAND)USING WATERPROOFING COMPOUND AT 1 KG PER CMENT BAG CURING THE SAME FOR NOT LESS THAN 2 DAYS AND KEEPING THE SURFAE OF THE BASE COAT ROUGH TO RECEIVE THE SAND FACED TREATMENT 8 MM THICK IN CEMENT MORTAR 1:4 FINISHING BY TAKING OUT GRAINS AND CURING FOR 14 DAYS , ETC., COMPLETE INALL RESPECTS AND AS DIRECTED INCLUDING NECESSARY SCAFFOLDING, CURING ETC. COMPLETE. |
| 46 | PROVIDING & FIXING EXTERIOR GRADE ALUMINUM COMPOSITE PANELS 3 MM THICK WITH SHEET OF APPROVED QUALITY AND MAKE(VIVA,EURO OR EQUIVALENT APPROVED MAKE) TO RCC STRUCTURES/BRICKWORKIN PLAIN CLEAR OR ANY APPROVED COLOUR WITH HEAVY SECTIONAL ALUMINUM FRAME WORK AND CLADDING COMPOSITES WITH SILICON SEALANTS INCLUDING PROVIDING SCAFFOLDING AND INSTALLATION IN PROPER LINE AND LEVEL AS DIRECTED BY EIC COMPLETE. |
| 47 | PROVIDING AND APPLYING (BY BRUSH/SPRAY) WATERPROOF ANTICARBONATION COATING ON EXTERIOR WALLS (SHALICRYL 215P OF M/S STP LTD OR KRISHNA CONCHEM OR EQUIVALENT AS APPROVED BY EIC) AS PER APPROVED SHADE IN TWO COATS INCLUDING M.S. PIPE SINGLE SCAFFOLDING(PUTLOG SCAFFOLD)/SUSPENDED ROPE PLATFORM, PREPARING THE SURFACES BY BRUSHING,WATERJET CLEANING AND BROOMING DOWN ETC. COMPLETE WITH ONE COAT OF PRIMER AS PER MANUFACUTRES SPECIFICATION ETC. COMPLETE AS DIRECTED BY EIC. |
| 48 | PROVIDING & FIXING IN POSITION MISC. MATERIALS NOT COVERED IN THE SCHEDULE OF RATES MENTIONED ABOVE INCLUDING TRANSPORTING, LOADING, UNLOADING AT SITE ETC. (CASH RECEIPT TO BE SUBMITTED). |
| 49 | PROVIDING & FIXING OF PROCELAIN CHINA WARE URINAL 635 X 395X 420 INCLUDING BRACKET AND ALL REQUIRED MATERIAL ETC. PVC OUTLET FOR URINAL OF SIZE 32MM DIA. CP DOOM TYPE WASTE COUPLING FOR URINAL ETC. COMPLETE. URINAL BRACKET, CP AUTO CLOSING ANGLE COCK, CP SPREADER CONNECTION FOR URINAL ETC. CP CONNECTOR FOR URINAL ETC. COMPLETE. ( CERA/HINDWARE/PARYWARE/JAGUAR ETC AS APPROVED BY EIC) |
| 50 | PROVIDING AND FIXING SINGLE LEAF FRP DOOR SHUTTER 30 MM THICK OF APPROVED SHADE AND PATTERN INCLUDING NECESSARY HARDWARE, LOCK, DOOR STOPPER, HANDLES AND OTHER FITTINGS ETC. AS DIRECTED BY EIC. |
| 51 | PROVIDING, DRILLING AND FIXING NIPPLES FOR PRESSURE INJECTION GROUTING OF POLYMER CEMENT GROUT ETC. COMPLETE |
| 52 | FILLING VOIDS / HONEYCOMB WITH HIGH PRESSURE INJECTION GROUTING OF POLYMER CEMENT GROUT (10% OF POLYMER BY WEIGHT OF CEMENT) |
| 53 | PROVIDING AND FIXING FRP MESH AS APPROVED BY EIC FOR WALLS, COLUMNS, BEAM JUNCTION |
| 54 | PROVIDING& FIXING IN POSITION ANODIZED ALUMINUM LOUVERED WINDOWS/VENTILATORS HAVINGFRAME MADE OUT OF SIZE 80 X 38 MM X 1.22 MM THICKNESS BOX TYPE WITH SHEET GLASS LOUVERS 5 MM THICK AND WOODEN ENCASEMENT WHEREVER NECESSARY ETC. AS DIRECTED BY EIC. |
| 55 | PROVIDING AND FIXING ISI MARKED HYDRAULIC DOOR CLOSER (80 TO 90 KG CAPACITY) FOR ALUMINIUM DOORS/WOODEN DOORS AS DIRECTED BY EIC. |
| 56 | PROVIDING AND FIXING TILED FALSE CEILING OF SPECIFIED MATERIALS OF SIZE 595X595 MM IN TRUE HORIZONTAL LEVEL, SUSPENDED ON INTERLOCKING METAL GRID OF HOT DIPPED GALVANIZED STEEL SECTIONS ( GALVANIZED @ 120 GRAMS/ SQM, BOTH SIDE INCLUSIVE) CONSISTING OF MAIN \"T\" RUNNER WITH SUITABLY SPACED JOINTS TO GET REQUIRED LENGTH AND OF SIZE 24X38 MM MADE FROM 0.30 MM THICK (MINIMUM) SHEET, SPACED AT 1200 MM CENTER TO CENTER AND CROSS \"T\" OF SIZE 24X25 MM MADE OF 0.30 MM THICK (MINIMUM) SHEET, 1200 MM LONG SPACED BETWEEN MAIN \"T\" AT 600 MM CENTER TO CENTER TO FORM A GRID OF 1200X600 MM AND SECONDARY CROSS \"T\" OF LENGTH 600 MM AND SIZE 24X25 MM MADE OF 0.30 MM THICK (MINIMUM) SHEET TO BE INTERLOCKED AT MIDDLE OF THE 1200X600 MM PANEL TO FORM GRIDS OF 600X600 MM AND WALL ANGLE OF SIZE 24X24X0.3 MM AND LAYING FALSE CEILING TILES OF APPROVED TEXTURE IN THE GRID INCLUDING, REQUIRED CUTTING/MAKING, OPENING FOR SERVICES LIKE DIFFUSERS, GRILLS, LIGHT FITTINGS, FIXTURES, SMOKE DETECTORS ETC. MAIN \"T\" RUNNERS TO BE SUSPENDED FROM CEILING USING GI SLOTTED CLEATS OF SIZE 27 X 37 X 25 X1.6 MM FIXED TO CEILING WITH 12.5 MM DIA AND 50 MM LONG DASH FASTENERS, 4 MM GI ADJUSTABLE RODS WITH GALVANIZED BUTTERFLY LEVEL CLIPS OF SIZE 85 X 30 X 0.8 MM SPACED AT 1200 MM CENTER TO CENTER ALONG MAIN T, BOTTOM EXPOSED WIDTH OF 24 MM OF ALL T-SECTIONS SHALL BE PRE-PAINTED WITH POLYESTER PAINT, ALL COMPLETE FOR ALL HEIGHTS AS PER SPECIFICATIONS, DRAWINGS AND AS DIRECTED BY ENGINEER-IN-CHARGE. PROVIDING AND FIXING 8 MM THICKPERFORATED CALCIUM SILICATE BOARD MADE WITH CALCAREOUS & SILICEOUS MATERIALS REINFORCED WITH CELLULOSE FIBER MANUFACTURED THROUGH AUTOCLAVING PROCESS TO GIVE STABLE CRYSTALLINE STRUCTURE WITH MINIMUM COMPRESSIVE STRENGTH 225 KG/ SQ. CM, BENDING STRENGTH 100 KG/SQ. CM , OF SIZE 595X595 MM, HAVING PERFORATION OF DIA. 10 MM WITH MINIMUM PERFORATED AREA 18 % WITH NON WOVEN TISSUE ON THE BACK SIDE, HAVING AN NRC ( NOISE REDUCTION COEFFICIENT) OF 0.85. |
| 57 | POINT WIRING THROUGH 20/25 MM HMS PVC CONDUIT WITH ALL REQUIRED ACCESSORIES WITH 2 NOS OF 1.5 SQMM & 1 NO OF 1.5 SQMM ( FOR EARTH) PVC INSULATED COPPER FRLS WIRES WITH MODULAR TYPE SWITCHES COMPLETE WITH ALL ACCESSORIES AS DETAILED IN THE SPECIFICATIONS. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FROM DB TO SWITCHBOARD & FROM SWITCHBOARD TO SWITCHBOARD. 2 NOS OF 2.5 SQMM & 1 NO OF 2.5 SQMM (FOR EARTH) PVC INSULATED COPPER FRLS CONDUIT SHALL BE FIXED ON WALL / TRAYS OR CEILING WITH SPACERS & SADDLES. THE WIRES WILL BE TERMINATED IN A SEPARATE CONNECTOR BEFORE FIXTURES. APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND,FINOLEX,KALINGAWIRES-FINOLEX/POLYCAB, SWITCHES-CLIPSAL-OPALE/NORTHWEST/SALZER/ANCHOR/CRABTREE/SSK |
| 58 | PRIMARY POINTS (3C*2.5 SQ.MM)(SWITCH BOX TO FIRST LIGHT POINT INCL. SUPPLY OF SWITCH & WIRING ACCESS.) |
| 59 | POINT WIRING WITH 3C*1.5 SQ.MM CU.FR LS WIRES IN PVC CONDUITS FROMPRIMARY POINTS TO SECONDARY POINTS |
| 60 | SECONDARY POINTS (LOOPING FROM PRIMARY POINT ONWARDS) |
| 61 | SECONDARY POINTS (1/2 POINT) ON SAME SWITCH BOARD 6 AMP WITH ACCESS. |
| 62 | SECONDARY POINTS (1/2 POINT) ON SAME SWITCH BOARD 6/16 AMP 5 PIN WITH ACCESS |
| 63 | POINT WIRING/POWER WIRING FOR WORKSTATIONS |
| 64 | SUPPLY & INSTALLATION OF THE FOLLOWING SOCKETS, SWITCHES |
| 65 | POINT WIRING THROUGH ALREADY LAID FLOOR RACEWAYS & CONDUITS WITH ALL REQUIRED ACCESSORIES WITH 2 NOS OF 2.5 SQMM & 1 NO. OF 2.5 SQMM (FOR EARTH) PVC INSULATED COPPER FRLS WIRES WITH MODULAR TYPE SWITCHES & SOCKETS COMPLETE WITH ALL ACCESSORIES AS DETAILED IN THE SPECIFICATIONS. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FRLS FROM DB TO SWITCHBOARD AND SOCKET TO SOCKET. APPROVED MAKES : WIRES-FINOLEX/ POLYCAB/HAVELLS/KEI/KEC/APAR, SWITCHES- CLIPSAL-OPALE/ NORTHWEST/ SALZER/ANCHOR/CRABTREE/SSK |
| 66 | 2 NOS. OF 6 A SOCKETS & 1 NO. 16 A SWITCH ON EACH TABLE (COMPUTER POWER) |
| 67 | 1 NO. OF 6 A SOCKETS & 1 NO. 6A SWITCH (RAW POWER) |
| 68 | Supply and laying of 2 Nos of 2.5 sqmm & 1 no. of 2.5 sqmm (for earth) PVC insulated Copper FRLS sheathed cable as spare cables through floor raceways and conduitcs |
| 69 | POWER WIRING FOR AC SOCKET/BAIN MARIE/OVEN/DEEPFRIZER/WALL-IN-COOLER/ELECTRIC CHIMNEY: POINT WIRING THROUGH 20/25MM DIA MG PVC CONDUITSWITH ALL REQUIRED ACCESSORIES WITH 2 NOS OF 4.0 SQMM & 1 NO OF 4.0 SQMM ( FOR EARTH) PVC INSULATED COPPER FRLS WIRES WITH MODULAR TYPE SWITCHES & SOCKETS COMPLETE WITH ALL ACCESSORIES AS DETAILED IN THE SPECIFICATIONS. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FRLS FROM ACDB/RPDB TO SOCKET TO SOCKET.APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND, WIRES-FINOLEX /POLYCAB/ BONTON, SWITCHES-CLIPSAL-OPALE/ NORTHWEST/ SALZER |
| 70 | 1 No. of 20A sockets & 1 No. 20A,100mA RCBO directly taken from ACDB/RPDB along with Metal clad switch socket.Rates shall include wiring (FRLS 3C*4sqmm CU Sheathed cable) of point from DB to Socket in PVC Conuict/casing-caping |
| 71 | SUPPLY AND LAYING RACEWAYS / CONDUITS (FOR UNDER FLOOR TRENCHES/ON TRAYS) ON EXISTING FLOORING. RACEWAYS/CONDUITS SHALL BE FIXED TO THE FLOORING WITH GI CLAMPS FOR FINISHED LEVELS AS PER THE SITE CONDITIONS OR THROUGH PARTITIONS WITH ALL ACCESSORIES. THE RATE SHALL PREPARATION OF TRENCHES UPTO 22” WIDE BY CAREFULLY REMOVING THE FLOOR TILES & MALWA BELOW THE TILES FOR LAYING RACEWAYS/CONDUITS FOR POWER, TELEPHONES ETC. THE DEPTH OF THE TRENCHES SHALL BE AT LEAST 2 INCHES FROM THE FINISHED FLOOR LEVEL OR UPTO RCC OF THE SLAB. THE RATE SHALL INCLUDE THE COST OF THE RACEWAYS/CONDUITS. THE RATE SHALL INCLUDE THE ACTIVITY OF CLEARING THE DEBRIS GENERATED FROM THE PREPARATION OF TRENCHES & FILLING THE SAME WITH PCC 1:2:3 9FOR THE PORTION WITHOUT FALSE FLOORING), APPROVED MAKES : GEETA/JINDAL |
| 72 | 80MM X 38MM X 2MM THICK RECTANGULAR ALUMINUM SECTION FOR ROUTING OF ELECTRICAL, DATA & VOICE CABLES AS SPECIFIED |
| 73 | 25 MM RIGID HG PVC CONDUITS |
| 74 | 20 MM RIGID HG PVC CONDUITS |
| 75 | SUPPLY AND LAYING OF SHEET STEEL FABRICATED METAL JUNCTION BOXES WITH KNOCKOUT HOLES ON THE SIDE WALLS OF THE BOX AND STAINLESS STEEL COVER OF 2.5/3 MM THICKNESS WITH A GASKET TO MAKE THE INSTALLATION WATER PROOF. JUNCTION BOXES SHALL BE FABRICATED FROM 16 GAUGE CRCA SHEETS DULY PAINTED WITH TWO COATS OF RED OXIDE PRIMER AND TWO COATS OF SYNTHETIC ENAMEL PAINT AND SHALL BE PROVIDED AT SUITABLE LOCATIONS SO THAT THE CABLES MAY BE PULLED OR REPLACED OF ADDITIONAL CABLES MAY BE PULLED WHENEVER REQUIRED IN FUTURE. COVER FOR THE TRUNKING SHALL ALSO BE FABRICATED AS ABOVE AND SHALL BE FIXED WITH RUST PROOF BRASS COUNTER SUNK LEVELER TYPE SCREWS. |
| 76 | S & I OF FLOOR JUNCTION BOXES OF SIZE 300MM X 300MM X 50MM |
| 77 | S & I OF FLOOR JUNCTION BOXES OF SIZE 200MM X 200MM X 50MM |
| 78 | LIGHTING FIXTURES - SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF FOLLOWING ITEMS, APPROVED MAKES: WIPRO/ PHILIPS/ HAVELLS |
| 79 | INDOOR COMMERCIAL RECESS MOUNTED LED LUMINAIRE. LIGHT FIXTURE COMPLETE WITH 1 X 36W LED LAMP.(600 X 600) APPROVED MAKE:BAJAJ,C&G,HAVELLS. |
| 80 | INDOOR COMMERCIAL ROUND RECESSED MOUNTED DOWN LIGHTER WITH LED FOR 3 X 6W.APPROVED MAKE:BAJAJ,C&G,HAVELLS. |
| 81 | SUPPLY & INSTALLATION OF EXHAUST FAN 120 MM SWEEP APPROVEDMAKE BAJAJ/ HAVELLS/ C&G/HAVELLS. |
| 82 | SUPPLY & INSTALLATION OF LED T/L FITTING 20W 4 FT. APPROVEDMAKE BAJAJ/ HAVELLS/ C&G/HAVELLS/PHILLIPS/WIPRO. |
| 83 | Supply and installation of five star rated, energy efficient Pedestal fans with BLDC motor. Approved Makes:Bajaj,C&G,USHA,Atomberg, Orient |
| 84 | IV) PUBLIC ADDRESS SYSTEM-APPROVED MAKES: PHILIPS/ BOSCH SUPPLY & INSTALLATION OF POINT WIRING FOR MUSIC CUM PA SYSTEM COMPRISING OF 14/36 SWG OR 0.2MM STRAND TIN CU FLEXIBLE POLYTHENE INSULATED SHIELD CABLE PULLED THROUGH 20 MM DIA. PVC MEDIUMGAUGE CONDUITS . 1.12 CORE FROM LOOPED FROM ONE SPEAKER TO OTHER |
| 85 | 1.2 SUPPLY, INSTALLATION, TESTING AND COMMSSIOINING OF 6 W CEILLING MOUNTEDSPEAKERS WITH LINE MATCHING TRANSFORMERS. |
| 86 | V) TELEPHONE & DATA SYSTEM.1.1 TELEPHONE POINT WIRING TELEPHONE OUTLETS POINTS: SUPPLY, LAYING & INSTALLATION OF FOLLOWING TELEPHONE POINT WIRING ON WORKSTATIONS/ TABLES/PARTITIONS BY USING 2-PAIR CABLE PULLED THROUGH ALREADY LAID FLOOR RACEWAYS/ CONDUITS AND TAKEN UP TO THE TABLE TOP USING PVC RIGID/ FLEXIBLE UP TO THE TABLE TOP CONDUITS RUN CONCEALED WITHIN WALLS/ PARTITIONS/ WORK STATIONS ETC. EACH POINT CONSISTING OF 1 NO.OF RJ- 11 JACK TYPE TELEPHONE SOCKET, CONCEALED MS BOX FLUSH TO THE SURFACE, FRONT PLATE ETC & MS BOX FLUSH TO THE SURFACE, FRONT PLATE ETC & HARDWARE AS REQUIRED TOGETHER FORMING ONE POINT.APPROVED MAKES:-WIRES – POLYCAB/FINOLEX/BONTON |
| 87 | SMOKE DETECTOR PANEL AND SENSORS |
| 88 | Programable and Addressable SMOKE DETECTOR FIXING AND COMMISSIONING |
| 89 | Signal Cable for Smoke Detector 2C*1.5sqmm armoured,FRLS |
| 90 | Supply, Installation and Commissining of Smoke detector panel (8 Zone Fire Alarm Control Panel having addressable feature, 30 smoke detectors per zone, zone display unit, Electronic Hooter 12-24VDc, Auto Dailer Unit, Installation and Commissioning |
| 91 | PANELS, DISTRIBUTION BOARDS - Supply Installation Testing & Commissioning of followingPanel System: 415V AC, 3PH, 50Hz, Fault Level 50KA for 1-sec.Wiring: The wiring will be carried out with 650/1100V grade PVC insulated stranded copper conductor.Control Circuit: 1.5SmmC.T. Circuit: 2.5SmmSwitch Fuse Unit/ MCB/MCCB: 32A = 6Smm, 63A = 16Smm, 125A = 35Smm,250A = 40 X 5 CuConstruction: Free Standing Floor/ Wall Mounting, Non-drawout & Compartmentalized.Fabrication: Base: 5 X 75mm Fabricated ChannelFrame: 14 SWG Thick CRCA Sheet Steel.Covers/ Doors: 16 swg thick CRCA Sheet Steel.Degree Of Protection: IP-42.Painting: Two coats of Primer & finish with Epoxy paint.Based Paint Shade: External/ Internal: Siemens Gray 7032, Semi Glossy.Base Channel: Black.Cable Entry: Bottom/ Top 3mm Thick CRCA Sheet Steel Detachable Gland plate.Busbars: Electrolytic grade Cu Busbares supported on SMC supports.The Busbar system is suitable for 415V, 3PH, 50Hz with fault withstanding capacity of 50KA for 1s.Heat shrinkable PVC sleeves & color code for phase identification provided.Earth Busbar: 1 X 25 X 6mm Cu.Minimum Busbar Clearances: Phase to Phase: 25.4mmPhase to Neutral: 25.4mmPhase to Ground: 25.4mmNeutral to Ground: 19.4mmLive Part to Ground: 19.4mSpecifications are generalized for both types mentioned below. |
| 92 | Supply Installation Testing & Commissioning of Main Panel (For ES Dept.) comprises,Incoming feeder,200A, FP,MCCB,50kA- 2 nos., with adjustable thermal magnetic trip unit. IndicatingLED lamps R,Y,B with fuses – 6 nos. 200A Change over switch onload type, Two (2) - Multi data meter with the facility to record kilowatthours(LOAD MANAGER). Make: Rishabh/ Meger / Elmeasure/ MECO. Six (6) -160/5A, 10VA, cl 1.0, CTs. Copper Busbar Outgoing Feeders : 100A, 4P, RCCBs – 2no., 63A 4P RCCBs- 2 Nos. 125A MCCB- 2 Nos.; 10A, SP, MCB – 48 nos.; 15A , SP, MCB – 18 nos., 20A, SP, MCB- 30 nos.; 25A, DP, ELCB / 100 Ma – 15nos. Elmex Terminals, size 6. Elmex Terminals, size 4. |
| 93 | Supply Installation Testing & Commissioning of following Panel System:In coming 125 A, 440V, 50 HZ, MADE UPOF SHEET STEEL MATERIAL, IP42 PROTECTION, WITH INCOMING 3PH + N 125 A,4P ISOLATOR & OUTGOING 18 NOS (6 PER PHASE) WITH 32 A RCBO,COMPLETELYPRE WIRRED, MAKE LEGRAND, HAVELLES, SIEMENS OR EQUIVALENT AS PERLATEST BIS STANDARD. |
| 94 | 16/25A/32 DP MCB IN ENCLOSURE |
| 95 | Supply of Neywork Spares |
| 96 | 12 Core Single ModeOutdoor armoured Fiber Optic Cable Of 9/125 Micron Specification, Brand Name - Systimax, AMP, Molex |
| 97 | 1U RACK MOUNT 24 PORT SC LOADED FIBER DISTRIBUTION UNIT(LIU) WITH ADAPTER STRIP AND COUPLERS, SPLICE TRAY, Brand Name - AMP |
| 98 | SC Pigtail Single Mode 9/125,Brand Name - AMP |
| 99 | LC-SC Single Mode Duplex Fiber Patch Cord Of 3 Meter Length,Brand Name - AMP/Digilink |
| 100 | LC-LC Single Mode Duplex Fiber Patch Cord Of 5 Meter Length, Brand Name - AMP/Digilink |
| 101 | UTP CAT 6e CABLE (300 M BOX)/STP CAT 6 CABLE(300 Meter Box), Brand Name - Digilink |
| 102 | UTP CAT 6E PATCH CORD OF 30 FEET LENGTH, Brand Name - Digilink |
| 103 | UTP CAT 6E PATCH CORD OF 7 FEET LENGTH, Brand Name - Digilink |
| 104 | UTP CAT 6E PATCH CORD OF 15 FEET LENGTH, Brand Name - Digilink |
| 105 | CAT 6E WALL MOUNT INFORMATION OUTLET WITH LOADED ONE RJ 45 PORT, Brand Name - Digilink |
| 106 | CAT 6e RJ 45 JACKS (1 BOX 100 NO. CONNECTORS), Brand Name - Digilink |
| 107 | CAT 6E 48 PORT RJ 45 PATCH PANEL WITH LOADED UTP MODULES, Brand Name - Digilink |
| 108 | CAT 6E 24 PORT RJ 45 PATCH PANEL WITH LOADED UTP MODULES, Brand Name - Digilink |
| 109 | 12U/15U Netwok Racks with Wall Mount Accessories, Brand Name - WQ/HCL/D-LINK/WALLRACK |
| 110 | 21 U FLOOR STANDING NETWORK RACK WITH FANS, WHEEL,TRAY & POWER ADAPTER STRIP FRONT AND BOTH SIDE DOOR OPENINGS, WQ/HCL/D-LINK/WALLRACK, Brand Name - WQ / APC / Valrack |
| 111 | 1 INCH PVC CONDUIT, T- JOINTS ACCESSORIES, COUPLERS ETC FOR FIXING, Brand Name - ISI Mark Precision Make |
| 112 | 1 INCH PVC CASING CAPING, T- JOINTS ACCESSORIES, COUPLERS ETC FOR FIXING, Brand Name - ISI Mark Precision Make |
| 113 | 1 INCH PVC FLEXIBALE PIPE, Brand Name - ISI Mark |
| 114 | 50 MM DWC Pipe (PLHDPE) ORANGE, Brand Name - ISI Mark |
| 115 | 5*5*2 Weatherproof PVC Junction Box, Brand Name - ISI Mark |
| 116 | PTZ Camera5MPX IP67, Brand Name - Axis/Vivotek/Matrix |
| 117 | Bullet Camera 5MPX IP67, Brand Name - Axis/Vivotek/Matrix |
| 118 | Dome Camera 5MPX IP67, Brand Name - Axis/Vivotek/Matrix |
| 119 | 8 port 10/100/1000 mbps Switch, Brand Name - TP-Link |
| 120 | Miniature Circuit Breakers (MCBs) 6 AMP, Brand Name - Anchor/ABB/Havells |
| 121 | Miniature Circuit Breakers (MCBs) 10 AMP, Brand Name - Anchor/ABB/Havells |
| 122 | Miniature Circuit Breakers (MCBs) 16 AMP, Brand Name - Anchor/ABB/Havells |
| 123 | Miniature Circuit Breakers (MCBs) 32 AMP, Brand Name - Anchor/ABB/Havells |
| 124 | Supply of Neywork Spares |
| 125 | Optical Fibre cable Pulling laying |
| 126 | OTDR TESTING OF FIBRE CABLE |
| 127 | SPLICING OF SMOPTICAL CABLE |
| 128 | UTP CABLE PULLING LAYING |
| 129 | FIXING OF 1 INCH PVC CONDUIT |
| 130 | FIXING OF WALL MOUNT INFORMATION OUTLET AND PUNCHING BOTH END |
| 131 | FIXING OF FIBRE DISTRIBUTION UNIT |
| 132 | FIXING OF UTP PATCH PANEL |
| 133 | Raceway Junction Box : Raceway for cable work as per drawing 4 heavy duty sectionaluminium Size : 38 mm x80 mm x2mm thick Heavy duty SS (Stainless steel) Face Plate size 300mm X 300 MMor 500mm x500 mm as per requirement |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail